Page 181
Nugget
6
Troubleshooting Co de 39
Problems Transmitting Data Through the DCS 300 If you have a problem while running the application on the terminal in a UDP Plus network, check these possible communications problems. Problem
Solution
Transaction Buffer Full.
The buffer holding transactions to be sent to the controller is full. Stop collecting data with this terminal. Make sure the terminal is communicating with the DCS 300 and let the terminal send all the transactions in the buffer before you continue collecting data.
Sending Buffer Transactions.
This is an information message to tell you that buffered transactions are now being sent to the DCS 300. You can begin collecting data again once the message clears.
Transaction Aborted.
The transaction just sent to the DCS 300 was not received. Try sending the transaction again.
Transmit Error XX, press Enter.
There is an error transmitting data to the DCS 300. XX represents the status code error. Note the error code listed in the message and contact your local Intermec service representative for help. Press to continue.
Receive Error XX, press Enter.
There is an error receiving data from the DCS 300. XX represents the status code error. Note the error code listed in the message and contact your local Intermec service representative for help. Press to continue.
Shutting down.
The DCS 300 is shutting down. You may continue collecting data and buffer the transactions in the terminal until the DCS 300 starts again, or stop collecting data with the terminal.
Controller Shutdown.
The DCS 300 has shut down. You may continue collecting data and buffer the transactions in the terminal until the DCS 300 starts again, or stop collecting data with the terminal.
6-13
Page 182
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co de 39
Bar Code Labels Will Not Scan If you cannot scan bar code labels or you are having problems with the laser scanner that is attached to the Scanner port, check these possible problems. Problem
Solution
A laser scanner is not attached to the Scanner port.
Make sure a laser scanner has been attached correctly to the Scanner port. For help, see “Attaching a Scanner” in Chapter 2.
The terminal is turned off.
Make sure the terminal is turned on. Press
You cannot see a red beam of light when you aim the scanner at a bar code label and pull the trigger.
There are two possible problems:
f to turn on the terminal.
• You may be too far away from the bar code label. Try moving closer to the bar code label and scan it again. • You may be scanning the bar code label “straight on.” Try changing the scanning angle until the laser beam is the brightest. This is the best scanning angle. You can test the effective range of the scanner. Move within 2 feet of a wall and test the scanner. You need to be within the scanning range to scan bar code labels. For help on scanning distances, see the guide that shipped with your laser scanner.
Warning Do not look directly into the window area or at a reflection of the laser beam while the laser is scanning. Long-term exposure to the laser beam can damage your vision. Avertissement Ne regardez pas directement la réflexion d’un rayon laser ou dans la fenêtre du laser lorsque celui-ci est en opération. Si vous regardez trop longtemps un rayon laser, cela peut endommager votre vue. You have a laser scanner attached to the Scanner port and cannot read any bar code labels.
You may not be using a laser scanner or cable that is supported for the T2455. For a list of supported scanners and cables, see “Input Devices for the Scanner Port” and “Cable Accessories” in Appendix A. Or, you may have the Scanner port configured for COM4. For help, see “Scanner Port (COM4)” in Chapter 9.
The laser scanner does not appear to work well or read bar code labels very quickly.
Try setting the Scanner Selection command to the specific input device you have attached. Check the bar code symbologies you have enabled on the terminal. Enable only the symbologies that you are using.
The laser scanner does not read the bar code labels quickly, or the scanning beam seems to be faint or obscured.
The scanner window may be dirty. Clean the scanning window with a solution of ammonia and water. Wipe dry. Do not allow abrasive material to touch the window.
6-14
Page 183
Nugget
Troubleshooting Co de 39
6
Bar Code Labels Will Not Scan (continued) Problem
Solution
The laser scanner will not read the bar code label.
Try these solutions: • Make sure you aim the scanner beam so it crosses the entire bar code label in one pass. • The angle you are scanning the bar code label may not be working well, or you may be scanning the label “straight on.” Try scanning the bar code label again, but vary the scanning angle. • The bar code label print quality may be poor or unreadable. To check the quality of the bar code label, try scanning a bar code label that you know scans. Compare the two bar code labels to see if the bar code quality is too low. You may need to replace the label that you cannot scan. • Make sure the bar code symbology you are scanning is enabled. Use the TRAKKER Antares 2400 Menu System to check the symbologies. On the Symbologies Menu, each symbology that is enabled has an asterisk (*) next to the name of the symbology. If your bar code symbology is disabled, enable it and then try scanning the bar code label again.
When you pull the trigger, the Good Read status light does not turn on.
Move within 2 feet of a wall and pull the trigger again. Make sure the scanner emits the red laser beam. If the status light does not turn on, there may be a problem with it. For help, contact your local Intermec service representative. If the laser beam does not turn on, check the other problems in this section for a possible solution.
When you release the trigger, the Good Read status light does not turn off.
The status light remains on if you configure the terminal to use edge triggering. If you configure the terminal for level triggering and the Good Read status light remains on, there may be a problem with the status light. Pull the trigger again without scanning a bar code label. If the status light is still on, contact your local Intermec service representative.
6-15
Page 184
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co de 39
Protecting Delicate Electronic Components As Intermec moves to surface mount technology and smaller components, our products become more vulnerable to damage from electrostatic discharge (ESD). Recently Intermec experienced spare board assembly failures in the field that were traced to improper ESD protection while handling or installing the boards. This is costly and can be easily avoided. Intermec’s Service department recommends that all field personnel follow three guidelines to prevent ESD damage: •
Use an ESD mat and wrist strap when repairing and replacing printed circuit boards.
•
Before you open any Intermec product, place that product on an ESD mat and ground the product.
•
Follow all standard ESD procedures for your workplace.
This icon appears at the beginning of any procedure in this manual that could cause you to touch components (such as printed circuit boards) that are susceptible to damage from electrostatic discharge (ESD). When you see this icon, you must follow standard ESD guidelines to avoid damaging the equipment you are servicing. Follow ESD Procedures
The Everett facility uses several vendors for ESD products. One USA vendor is DESCO Industries, Inc., which you can reach at telephone (909) 598-2753 or on the World Wide Web at http://www.desco.com/. This table lists part numbers from DESCO’s 1996 catalog. However, you may want to find your own sources for ESD products.
6-16
Part Number
Description
7755
Large Service Kit 22 x 24
7780
Standard Service Kit 18 x 22
7790
Pocket Kit 15 x 20
A77115
Work Table Mat 24 x 48
Page 185
Nugget
Troubleshooting Co de 39
6
Maintaining and Cleaning the Terminal The terminals are built for use in a rugged, industrial working environment. You may need to perform these minor maintenance tasks to keep the terminal in good working order: •
Clean the terminal screen.
•
Check the mounting bracket.
Each procedure is described in detail in this section. To order replacement parts, contact your local Intermec service representative or contact Intermec at: Intermec Corporation 6001 36th Ave. West P.O. Box 4280 Everett, Washington 98203-9280 Telephone: 1-425-348-2600
Cleaning the Terminal Screen To keep the terminal in good working order, you need to clean the terminal screen. Clean this surface as often as needed or when it is dirty. To clean the terminal screen 1. Press f to turn off the terminal.
2. Use a solution of ammonia and water. 3. Dip a clean towel or rag in the ammonia solution and wring out the excess solution. Wipe off the terminal screen. Do not allow any abrasive material to touch this surface. 4. Wipe dry.
Checking the Mounting Bracket Periodically inspect the knob on the mounting bracket to make sure they are still tight. Check the mounting bracket for any signs of fatigue, such as cracking, which might develop over extended use in extreme (vibration) environments. Replace any damaged hardware immediately to ensure continued, safe operation.
6-17
Page 186
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co de 39
Booting the Terminal You seldom need to boot or reset the terminal. When you boot the terminal, it runs through power-on self test (POST) to test each major subsystem. The terminal uses the configuration currently saved in flash memory. Once the terminal is finished booting, your application appears on the screen. You can boot the terminal using these two methods:
f key to boot the terminal when you turn on the terminal.
•
Configure the
•
Use the Boot Menu.
Booting the Terminal on Resume f f
When you press to turn off the terminal, it turns off and goes into Suspend mode. When you press to turn on the terminal, it resumes or boots depending on the terminal configuration. There are two ways to configure the command:
f key using the Resume Execution configuration
Resume Execution Not Allowed Configures the terminal to boot and restart your application each time you press to turn on the terminal. Use this option if you want to restart your application every time you turn on the terminal.
f
Resume Execution Allowed Configures the terminal to resume exactly where it was when you turned off the terminal. Use this option to resume working each time you turn on the terminal. You can configure the Resume Execution command by using the TRAKKER Antares 2400 Menu System or by scanning these bar code labels. For help, see Chapter 3, “Configuring the Terminal,” or “Resume Execution” in Chapter 9. Resume Execution Not Allowed
Resume Execution Allowed
*$+ER0*
*$+ER1*
*$+ER0*
*$+ER1*
Using the Boot Menu The Boot menu appears after you:
6-18
• replace the backup battery and turn on the terminal.
• upgrade the firmware.
• reset the terminal.
Page 187
Nugget
Troubleshooting Co de 39
6
Boot Menu
BOOT
MENU
F1
-
Boot
F2
-
Run
F3
-
Power
POWER
DOWN
System Loader
IN
Down
60
SEC 2455U.040
The Boot Menu contains these commands:
b Run Loader Press Z to load the terminal firmware. To upgrade or load the firmware,
Boot System Press to boot the terminal. Once the terminal is finished booting, your application appears on the screen. you should use the Firmware Upgrade option in the TRAKKER Antares 2400 Menu System. For help, see “Upgrading the Firmware” in Chapter 3.
[
Power Down Press to turn off the terminal. When you turn on the terminal, the Boot Menu screen appears again if POST passes.
Troubleshooting a Locked Up Application If the terminal or application appears to be locked up, try these steps in order. To troubleshoot a locked-up terminal or application f
1. Press to turn off the terminal. If it turns off, press continue working.
f to turn on the terminal and
2. Scan the Reset Firmware label to restart the firmware and application. Reset Firmware
*-.* *-.*
You can also send the Reset Firmware command over the network. For help, see Chapter 8, “Reader Command Reference.” If it works, you can continue working.
6-19
Page 188
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co de 39
3. Scan the Boot Terminal label to reboot the terminal. If it works, you can continue working. Boot Terminal
*-.1* *-.1* f
4. Configure the Resume Execution command to resume “not allowed.” For help, see “Resume Execution” in Chapter 9. Each time you press to turn on the terminal, the terminal boots and restarts your application.
a
5. If your terminal appears to boot but the application will not run or is locked up, press and hold the key immediately after you scan the Reset Firmware label or press to turn on the terminal in Step 3. Continue to hold the key for at least 30 seconds after the TRAKKER Antares welcome screen has cleared.
f a
The terminal has booted without loading an application. Use the TRAKKER Antares 2400 Menu System to load another application or download a new version of the application before you run it again. 6. If the terminal will not turn off or does not respond to the Reset Firmware command, reset the terminal as described in the next procedure. Make sure you have tried Steps 1 and 2 before you reset the terminal.
Resetting the Terminal If you performed the steps in “Troubleshooting a Locked Up Application” and the terminal will not turn off or respond to the Reset Firmware command, follow the steps in this section to reset the terminal. Perform this procedure only in a clean, dry area to avoid trapping any moisture or dirt inside the unit. Caution If the terminal is turned on and you push the Reset button, you may lose data and you may have to reload the firmware. Conseil Si le terminal est allumé et que vous appuyez sur le bouton de remise à zéro, vous risquez de perdre des données et d’avoir à recharger le microprogramme.
1. Use an ESD mat and wear a wrist strap to protect the components from ESD damage. For help, see “Protecting Delicate Electronic Components” earlier in this chapter. Follow ESD Procedures
6-20
2. Press f to turn off the terminal. If it will not turn off, continue with the next step.
3. Unplug the port plugs from any terminal ports that do not have a cable connected.
Page 189
Nugget
Troubleshooting Co de 39
6
4. Use a Torx screwdriver (size 20) to remove the four screws on the back panel. Screw (4 places)
2455U.098
5. Remove the back panel. 6. Press the Reset button. The T2455 will briefly turn on and then turn off. Reset button
2455U.099
7. Place the back panel on the back of the terminal. 8. Use a Torx screwdriver (size 20) to tighten the four screws to 24 in-lb torque. 9. Insert the rubber port plug into each terminal port that does not have a cable connected.
f
10. Press to turn on the terminal. It boots all the systems and clears RAM memory. The Boot Menu appears.
6-21
Page 190
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co 11. Press de 39 b to boot the terminal and start your application.
If you keep returning to the Boot Menu or the terminal will not boot, try loading the firmware. For help, see “Upgrading the Firmware” in Chapter 3. If the terminal will not boot or reset, contact your local Intermec service representative for help.
Replacing the Backup Battery The backup battery should provide years of backup battery power and you will seldom need to replace it. You can replace the backup battery if it will no longer hold a charge, if the battery status on the Battery/PIC diagnostic screen is bad, or if the battery is dead. Call your local Intermec service representative to order a new backup battery (Part No. 066900S-001). Caution When you replace the backup battery, all data stored in RAM is lost. Conseil Lors du remplacement de la batterie de secours, toutes les données stockées dans la mémoire vive (RAM) sont perdues.
Removing the Backup Battery Perform this procedure only in a clean, dry area to avoid trapping any moisture or dirt inside the unit. 1. Use an ESD mat and wear a wrist strap to protect the components from ESD damage. For help, see “Protecting Delicate Electronic Components” earlier in this chapter. Follow ESD Procedures
2. Save all data stored in RAM and exit the application. Any data stored in flash memory or on drive G will be saved automatically. 3. Press f to turn off the terminal.
4. Disconnect the power cable. 5. Unplug the port plugs from any terminal ports that do not have a cable connected. 6. Use a Torx screwdriver (size 20) to remove the four screws on the back panel. 7. Remove the back panel. Notice that the foam pad on the inside of the panel was positioned over the backup battery. Later, when you replace the back panel, you must make sure the foam pad returns to that position.
6-22