Page 171

Nugget

Troubleshooting Co de 39

6

This chapter lists the problems you may have while using the terminal and gives some possible solutions. You will also find instructions that explain how boot or reset the terminal, clean the terminal screen, and replace the backup battery.

How to Use This Chapter If you have any problems with the TRAKKER Antares 2455 terminal, use this table as a guide to find the problem and solution in this chapter: Problem

See This Section to Find a Solution

Page

Screen is blank, terminal is locked up, or message is displayed.

“Problems While Operating the Terminal”

6-5

Configuring the terminal

“Problems While Configuring the Terminal”

6-7

RF communications error

“Terminal Will not Communicate With RF Network Devices”

6-11

Application error

“Problems Transmitting Data Through the DCS 300”

6-13

Scanning labels

“Bar Code Labels Will Not Scan”

6-14

Boot Menu appears or terminal is locked up.

“Booting the Terminal”

6-18

The terminal screen is dirty, or the mounting bracket bolts are loose.

“Maintaining and Cleaning the Terminal”

6-17

Note: If you have problems with the 3270, 5250, or VT/ANSI terminal emulation application, see the TRAKKER Antares Terminal Emulation User’s Guide.

6-3

Page 172

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co de 39

Finding and Solving Problems If you have a problem while configuring or using the terminal, use the tables in this section to find a solution. For easy reference, problems are grouped into these topics: •

Problems While Operating the Terminal

•

Problems While Configuring the Terminal

•

Terminal Will Not Communicate With RF Network Devices

•

Problems Transmitting Data Through the DCS 300

•

Bar Code Labels Will Not Scan

•

Protecting Delicate Electronic Components

•

Maintaining and Cleaning the Terminal

•

Booting the Terminal

•

Troubleshooting a Locked Up Application

•

Resetting the Terminal

•

Replacing the Backup Battery

Note: You can also use the diagnostics to help analyze and solve problems. For help, see Chapter 7, “Running Diagnostics.” Caution There are no user-serviceable parts inside the terminal. Opening the unit will void the warranty and may cause damage to the internal components. Conseil La terminal ne contient pas de pièces révisibles par l’utilisateur. Le fait d’ouvrir l’unité annule la garantie et peut endommager les pièces internes. If you send the terminal in for service, it is your responsibility to save the terminal data and configuration. Intermec is responsible only for ensuring that the keypad and other hardware features match the original configuration when repairing or replacing your terminal.

6-4

Page 173

Nugget

Troubleshooting Co de 39

6

Problems While Operating the Terminal If you are operating the terminal and have trouble, check these possible problems and solutions. Problem

Solution

The screen is blank and the Power status light is blinking.

Make sure the external power supply is connected. The terminal cannot operate without an external power supply.

You scan a reader command, such as Backlight On, and nothing happens.

The reader commands are disabled. Scan the Enable Override command shown here to temporarily enable all of the reader commands. You can also enable or disable reader commands with the TRAKKER Antares 2400 Menu System. For help, see “Command Processing” in Chapter 9. When you are finished, remember to disable the override so that your data is not interpreted as a command. Enable Override

*$+DC3* *$+DC3* You scan a valid bar code label to enter data for your application. The data decoded by the scanner does not match the data encoded in the bar code label.

The terminal may have decoded the bar code label in a symbology other than the label’s actual symbology. Try scanning the bar code label again. Make sure you scan the entire label.

You want to set the terminal back to the default configuration to start over configuring the terminal.

Scan this bar code label:

To operate the terminal quickly and efficiently, you should enable only the bar code symbologies that you are going to scan. If you enable multiple symbologies, the terminal may on rare occasions decode a bar code according to the wrong symbology and produce erroneous results.

Default Configuration

*.+* *.+*

Or, use the TRAKKER Antares 2400 Menu System. For help, see “Restoring the Terminal’s Default Configuration” in Chapter 3. Note: After you load the default configuration on a T2455, you may need to set the primary network communications parameters to communicate with other devices in the network. You cannot scan bar code labels with the laser scanner attached to the Scanner port.

See “Bar Code Labels Will Not Scan” later in this chapter.

6-5

Page 174

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co de 39

Problems While Operating the Terminal (continued) Problem

Solution

The terminal appears to be locked up and you cannot enter data.

Try these possible solutions: • Wait at least 10 seconds and try again. If the terminal is in the process of connecting to the DCS 300 or host, the terminal will ignore any input from the keypad or scanner. If the Network Connect status light appears and remains on, you can continue working. • Scan any bar code label to see if the terminal responds. • Follow the instructions in “Troubleshooting a Locked Up Application” later in this chapter.

The terminal is booting and you see a message that POST failed.

The screen displays the system that failed POST. Report the error message to your supervisor.

] to exit the error message. The Boot Menu appears. Press Press boot the terminal. Your application appears on the screen. If the terminal still will not boot, contact your local Intermec service representative for help. The terminal displays the Boot Menu.

You will see the Boot Menu in these two situations:

b to b

• You replace the backup battery. Once you replace the battery and turn on the terminal, the Boot Menu appears. Press to boot the terminal and continue working.

b

• You just finished upgrading the firmware on the terminal and POST failed. Press to boot the terminal. Report the problem to your supervisor. For help on the Boot Menu, see “Booting the Terminal” later in this chapter. The Power status light blinks and an external power supply is connected.

The backup battery charge is low. Make sure an external power supply is connected and there is power to the terminal. The backup battery will be fully charged in approximately 14 hours. If you have been using the terminal in a cold temperature environment, move the terminal to a warmer environment to charge the backup battery. You can replace the backup battery if it will no longer hold a charge, if the battery status on the Battery/PIC diagnostic screen is bad, or if the battery is dead. For help, see “Replacing the Backup Battery” later in this chapter.

6-6

Page 175

Nugget

Troubleshooting Co de 39

6

Problems While Configuring the Terminal You can configure the terminal by using the TRAKKER Antares 2400 Menu System or by scanning configuration commands. If you have problems configuring the terminal, check these possible problems and solutions. Problem

Solution

On the T2455, you configure the RF security ID and the changes do not appear to be saved.

You can only set the RF security ID with the 2.4 GHz RF network enabled. The Network Activate configuration command must be configured to 2.4 GHz RF network before you can save any changes to the RF security ID command.

You see this error message when exiting the Configuration Menu:

The 2.4 GHz RF network is enabled and there is a problem with the network configuration. You need to change the terminal IP address and/or the controller IP address (host IP address for a TCP/IP network). Choose Primary Network from the Communications Menu.

Network configuration error. Network is enabled. Terminal IP address or Controller (Host) IP address set to an invalid address of 0.x.x.x or 127.x.x.x. Configuration was not updated.

You see this error message when exiting the Configuration Menu: Network configuration error. Network is enabled. Terminal IP address and Default Router address set to the same address. Configuration was not updated.

The terminal IP address or the controller/host IP address is set to 0.x.x.x or 127.x.x.x. These are invalid addresses. Set a valid IP address for the terminal and DCS 300 or host. For help, see “Using RF Communications on the Terminal” in Chapter 4. If you cannot fix the addressing problem, check with your network administrator to get the IP address assigned to the terminal and the controller or host. The 2.4 GHz RF network is enabled and there is a problem with the network configuration. You need to change the terminal IP address and/or the default router address. Choose Primary Network or Advanced Network from the Communications Menu. The terminal IP address and the default router address are both set to the same address. Set a valid IP address for the terminal and the default router. For help, see “Using RF Communications on the Terminal” in Chapter 4. If you cannot fix the addressing problem, check with your network administrator to get the IP addresses for each RF network device.

You see this error message when exiting the Configuration Menu: Network configuration error. Network is enabled. Terminal IP address or Controller (Host) IP address set to the same address. Configuration was not updated.

The 2.4 GHz RF network is enabled and there is a problem with the network configuration. You need to change the terminal IP address and/or the controller IP address (host IP address for a TCP/IP network). Choose Primary Network from the Communications Menu. The terminal IP address and the controller/host IP address are both set to the same address. Set a valid IP address for the terminal and DCS 300 or host. For help, see “Using RF Communications on the Terminal” in Chapter 4. If you cannot fix the addressing problem, check with your network administrator to get the IP address assigned to the terminal and the controller or host.

6-7

Page 176

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co de 39

Problems While Configuring the Terminal (continued) Problem

Solution

You see this error message when exiting the Configuration Menu:

The 2.4 GHz RF network is enabled and there is a problem with the network configuration. You need to change the default router address. Choose Advanced Network from the Communications Menu.

Network configuration error. Network is enabled. Default Router address is not on the terminal’s network. Configuration was not updated.

The terminal and DCS 300 (UDP Plus network) or host (TCP/IP network) are on different networks, and the terminal is not on the same network as the default router. When the terminal is on a different IP subnetwork from the DCS 300 or host, you must set the Default Router and Subnet Mask commands. Set a valid IP address for terminal, DCS 300 or host, and default router. For help, see “Using RF Communications on the Terminal” in Chapter 4. If you cannot fix the addressing problem, check with your network administrator to get the IP addresses for each RF network device.

You are configuring the serial port and see this error message when exiting the Configuration Menu:

You must configure a value for EOM before you can set SOM or disable SOM. You need to change the value of SOM. Choose Serial Port from the Communications Menu.

Serial port configuration error.

The Configurable protocol uses EOM to determine the serial communications mode. When EOM is disabled, the terminal communicates in Character mode. When EOM is enabled, the terminal communicates in Frame mode. To use Frame mode, you need to set EOM first. Next, configure Handshake, Configuration Commands Via Serial Port, LRC, SOM, and then Poll.

SOM is set. You must also set EOM. Configuration was not updated.

For help, see “Using Serial Communications on the Terminal” in Chapter 4. You are configuring the serial port and see this error message when exiting the Configuration Menu: Serial port configuration error.

SOM cannot equal the same value that is set for EOM. You cannot set SOM to any of these values: AFF (ACK), DLE, NEG (NAK), Poll, RES (EOT), REQ (ENQ), SEL, XOFF, or XON. You need to change the value of SOM. Choose Serial Port from the Communications Menu. For help, see “Start of Message (SOM)” in Chapter 9.

SOM cannot equal EOM. Configuration was not updated. You are configuring the serial port and see this error message when exiting the Configuration Menu: Serial port configuration error. EOM #1 cannot equal EOM #2. Configuration was not updated.

6-8

EOM can be one or two ASCII characters, but you cannot set the first and second character to the same character. Also, you cannot set EOM to any of these values: AFF (ACK), DLE, NEG (NAK), Poll, RES (EOT), REQ (ENQ), SEL, XOFF, or XON. You need to change the value of EOM #1 or #2. Choose Serial Port from the Communications Menu. For help, see “End of Message (EOM)” in Chapter 9.

Page 177

Nugget

Troubleshooting Co de 39

6

Problems While Configuring the Terminal (continued) Problem

Solution

You are configuring the serial port and see this error message when exiting the Configuration Menu:

You cannot set EOM or SOM to any of these values: AFF (ACK), DLE, NEG (NAK), Poll, RES (EOT), REQ (ENQ), SEL, XOFF, or XON. You need to change the value of EOM or SOM. Choose Serial Port from the Communications Menu.

Serial port configuration error. DLE, XON, XOFF are not valid values for either SOM or EOM.

For help, see “End of Message (EOM)” or “Start of Message (SOM)” in Chapter 9.

Configuration was not updated. You are configuring the serial port and see this error message when exiting the Configuration Menu:

PG is the Handshake configuration command. You need to change the value of Handshake or set other serial port parameters. Choose Serial Port from the Communications Menu.

PG command failed.

The order in which you set serial port protocol configuration commands is important. To use Frame mode, you need to set EOM first. Next, configure Configuration Commands Via Serial Port, Handshake, LRC, and then SOM. To use Character mode, you need to disable these same parameters in reverse order.

Configuration was not updated.

For help, see “Using Serial Communications on the Terminal” in Chapter 4. You are configuring SOM or EOM in the Configuration Menu and cannot set two characters.

You may have a space in the SOM or EOM field. The space does not show, but it is a valid character. To clear a space from the field, put the . Now set the two-character value for cursor in the field and press SOM or EOM.

You are scanning a configuration command to set one of the serial port parameters and hear three low beeps. For example, you are trying to set EOM or SOM.

The order in which you scan serial port protocol configuration commands is important. The Configurable protocol uses EOM to determine the serial communications mode. When EOM is disabled, the terminal communicates in Character mode. When EOM is enabled, the terminal communicates in Frame mode.

d

To use Frame mode, you need to set EOM first. Next, configure Configuration Commands Via Serial Port, Handshake, LRC, and then SOM. To use Character mode, you need to disable these same parameters in reverse order. For help, see “Using Serial Communications on the Terminal” in Chapter 4.

6-9

Page 178

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co de 39

Problems While Configuring the Terminal (continued) Problem

Solution

You see this error message when exiting the Configuration Menu:

The two-character name (syntax) of the configuration command that failed is listed on the first line of the error message. For example, you may see this message:

Commandname command failed. Remainder of configuration not updated.

SS command failed. There may be a problem with the configuration due to a change made with the Scanner Selection (SS) command. Check the command listed in the message. To find the command, use the “Configuration Commands by Syntax” table in Appendix A. Make sure the command is set correctly for the options and network communications you are using with the terminal. For help, see Chapter 9, “Configuration Command Reference.”

You scan a configuration command, such as Keypad Caps Lock, and you hear three low beeps.

If you are working in the TRAKKER Antares 2400 Menu System, you cannot scan configuration commands. Use the Configuration Menu to change the terminal’s configuration, or exit the menu system to scan configuration commands.

You scan a configuration command, such as Keypad Caps Lock, and nothing happens.

There are two possible solutions: • You may have one or more reader commands disabled, such as Change Configuration, so that you cannot change the configuration. Enable all of the reader commands and try again. • The terminal may be waiting for another command to complete the configuration change. If you started by scanning the Enter Accumulate command, you must finish the command by scanning the Exit Accumulate command. For help, see Chapter 9, “Configuration Command Reference.” Scan the Enable Override to temporarily enable all of the reader commands. When you are finished, remember to disable the override so that your data is not interpreted as a command. Enable Override

*$+DC3* *$+DC3*

6-10

Page 179

Nugget

Troubleshooting Co de 39

6

Problems While Configuring the Terminal (continued) Problem

Solution

You scan a configuration command to set one of these parameters and hear three low beeps:

If the Network Activate command is enabled (2.4 GHz RF network enabled) and you are configuring the terminal, these addresses must define a valid network configuration. For example, an invalid network configuration would be a controller (or host) IP address set to 0.0.0.0 with the network enabled.

• Controller IP Address (UDP Plus) or Host IP Address (TCP/IP) • Terminal IP Address • Default Router • Network Activate

To set these four parameters, follow these steps: 1. Disable the Network Activate (NA) configuration command. 2. Set the terminal IP address and the controller IP address or the host IP address. 3. Set the default router address (if necessary). 4. Enable the Network Activate command. You can change an IP address with the network enabled as long as it still defines a valid network configuration.

Terminal Will Not Communicate With RF Network Devices If you cannot get the terminal to communicate with other devices in the 2.4 GHz RF network, check these possible problems. Problem

Solution

When you turn on the terminal after it was suspended for awhile (10-15 minutes or longer), the terminal can no longer send or receive messages over the network.

The host may have deactivated or lost your current terminal emulation session. In a TCP/IP direct connect network, you need to turn off the “Keep Alive” message (if possible) from the host so that the TCP session is maintained while a terminal is suspended.

The Network Connect status light is turned off. The terminal is not communicating with the access point.

Make sure the Network Activate command is enabled. Also make sure the terminal is configured correctly for your network. To communicate with the access point, the RF domain and RF security ID on the terminal must match the values set for all access points the terminal may communicate with. For help, see “Using RF Communications on the Terminal” in Chapter 4. Make sure the access point is turned on and operating. You may be using the terminal out of the RF range of an access point. Try moving closer to an access point to re-establish communications. In a TCP/IP direct connect network, you cannot scan or enter data when the terminal is not communicating with an access point or you may lose your TCP session. Try moving closer to an access point to re-establish communications.

6-11

Page 180

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co de 39

Terminal Will Not Communicate With RF Network Devices (continued) Problem

Solution

The Network Connect status light blinks.

In a UDP Plus network, the terminal is not connected to the DCS 300. You may need to check the terminal’s configuration or make sure the DCS 300 is running and that data collection is started. The terminal may be out of range of an access point or the access point may have recently been turned off. Make sure the access point is still turned on. Each device in the 2.4 GHz RF network must have a valid IP address. The IP addresses set on the terminal must match the addresses configured on the DCS 300 or host. For help, see “Using RF Communications on the Terminal” in Chapter 4.

The terminal is connected to the host computer and you move to a new site to collect data. The Network Connect status light was on and now begins to blink or turns off.

You may have gone out of range of an access point. Try moving closer to an access point or to a different location to re-establish communications. Once you are in range again, the Network Connect status light will appear and remain on. Any data you collected while you were out of range will be transmitted over the network.

The Network Connect status light blinks and you see this message:

The terminal is connected to the access point, but is trying to establish communications with the DCS 300 and the host computer. Make sure the terminal is correctly configured for your network. Make sure the DCS 300 is configured and running. Make sure the host computer is configured and running.

Unable to connect to controller. Error 102. Unable to establish connection to host. Session ended.

If you have configured the network correctly, try restarting the DCS 300 to establish communications. You can also try resetting the terminal. For help, see “Resetting the Terminal” later in this chapter.

The Network Connect status light remains on, but the host computer is not receiving any data from the terminal.

There may be a problem with the connection between the DCS 300 and the host computer. Check with your network administrator or use the DCS 300 System Manual to troubleshoot any potential problems on the controller. In a TCP/IP network, there may be a problem with the connection between the access point and the host computer. Check with your network administrator or use your access point user’s manual.

The Network Connect status light remains on, but you cannot establish a terminal emulation session with the host computer.

There may be a problem with the host computer, a problem with the connection between the DCS 300 and the host computer, or a problem with the connection between the access point and the host (TCP/IP). Check with your network administrator to make sure the host is running and allowing users to login to the system.

6-12