Page 101
nugget cCODE39Configuring the Terminal
3
Saving Configuration Changes in Flash Memory The TRAKKER Antares 2455 terminal uses two copies of the configuration: Runtime or RAM configuration This configuration is the current or active set of parameters and options enabled on the terminal. The configuration is stored in RAM and will be lost if you boot or reset the terminal. Boot or flash configuration This configuration is the set of parameters and options last saved in flash memory. The configuration is stored in flash memory and will be saved and used if you boot or reset the terminal. Here are the four ways you can configure the terminal and how the configuration is updated: Runtime or RAM Configuration Updated?
Boot or Flash Configuration Updated?
Using the TRAKKER Antares 2400 Menu System
Yes (see Note)
Yes (see Note)
Scanning bar code labels
Yes
No
From a host application through the serial port
Yes
No
From the network (DCS 300 or host)
Yes
No
Configure the Terminal
Note: You are prompted to save your changes in RAM and flash as you exit the Configuration Menu and the TRAKKER Antares 2400 Menu System. Your changes are saved if you choose Yes at each screen. If you configure the terminal by scanning bar code labels, through the serial port or from the network, you may want to save the changes in flash memory using one of these methods: •
Scan or send the Save Configuration in Flash Memory reader command.
•
Use the TRAKKER Antares 2400 Menu System.
To save configuration changes using the reader command •
Scan this bar code label: Save Configuration in Flash Memory
*.+1* *.+1*
Or, send the command .+1 as the last command from the controller or host application. For help, see Chapter 4, “Operating the Terminal in a Network.”
3-19
Page 102
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget cCODE39
To save configuration changes using the menu system 1. Press or scan this bar code.
Enter Test and Service Mode
*..-.* *..-.*
The Main Menu appears. 2. Choose System Menu and press
The System Menu appears.
SYSTEM MENU File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware ⁄
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 2455U.046
3. Choose the Store Configuration command and press screen appears.
The Store Configuration
4. Choose OK to save the configuration in flash memory. To exit without saving the configuration, choose Cancel. The System Menu appears.
? to exit the System Menu. The Main Menu appears. 6. Choose another menu from the Main Menu or press ? to exit the TRAKKER 5. Press
Antares 2400 Menu System.
Restoring the Terminal’s Default Configuration When you configure the terminal according to the instructions presented in this chapter, the parameters remain in effect until you reconfigure them. If you configure the terminal but do not save your changes in flash memory, the parameters will remain in effect until you boot or reset the terminal. The default configuration for the terminal is listed in Appendix A. You can use the TRAKKER Antares 2400 Menu System or scan the Default Configuration bar code label to return the terminal to its default configuration.
3-20
Page 103
3 nugget cCODE39Configuring the Terminal
Note: If you restore the default configuration, you need to set the primary network communications parameters on the terminal to reestablish communications with other devices in the 2.4 GHz RF network. You may also need to reset the serial port parameters to communicate with other serial devices. To restore the default configuration using the reader command •
Scan this bar code label: Default Configuration
*.+0* *.+0*
To restore the default configuration using the menu system or scan this bar code:
1. Press
Enter Test and Service Mode
*..-.* *..-.*
The Main Menu appears. 2. Choose System Menu and press
The System Menu appears.
3. Choose the Load Default Values command and press . The Load Default Values screen appears.
LOAD
4. Choose OK and press to load the default configuration values. The default values will override the current runtime configuration on the terminal.
To exit without loading the default values, choose Cancel and press . The System Menu appears.
?
5. Press to exit the System Menu. The Main Menu appears.
DEFAULT
VALUES
Load default configuration values in RAM? (Overwrites current configuration)
OK
CANCEL 2455U.074
?
6. Choose another menu from the Main Menu or press to exit the TRAKKER Antares 2400 Menu System. For help exiting the menu system, see “Exiting the TRAKKER Antares 2400 Menu System” earlier in this chapter.
3-21
Page 104
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget cCODE39
Configuring Drives and Memory on the Terminal The TRAKKER Antares 2455 terminal comes with a 750K flash drive (C) and 512K RAM reserved for applications. You can also order the T2455 with the 4MB flash memory option, 2MB of which is configurable. You can customize the terminal to your needs by configuring • up to 256K of the 512K RAM as a RAM drive.
• the additional 2MB flash memory (of the total 4MB) to either store double-byte fonts or as a 2MB drive.
The next sections explain how to customize the terminal by configuring RAM and configuring flash memory.
Configuring the RAM Drive On the T2455, you have 512K total RAM for the application execution space. You can configure up to 256K of the total 512K application execution space as a RAM drive. If the RAM drive is configured, your application execution space is reduced by the amount of the RAM drive. For example, if your application size is 64K and drive E is configured as a 256K RAM drive, you are using 320K of the 512K application execution space. The application uses the remaining 192K of RAM as a Malloc/free dynamic memory pool. By default, the RAM drive is not configured and the memory is available for applications. You can configure the size of the RAM drive (E) and use drive E to temporarily store data and files (up to 32 files). To configure the RAM drive, you can use either the TRAKKER Antares 2400 Menu System or the RAM Drive Size configuration command. For help using the configuration command, see “RAM Drive Size” in Chapter 9. Important: After you disable or configure the RAM drive, you must save the configuration in flash memory and boot the terminal for the change to take effect. Note: When you boot or reset the terminal, all files on the RAM drive are destroyed. To configure the RAM drive or scan this bar code to access the TRAKKER Antares
1. Press 2400 Menu System:
Enter Test and Service Mode
*..-.* *..-.*
The Main Menu appears.
3-22
Page 105
nugget cCODE39Configuring the Terminal
V
2. Press to choose the Configuration Menu and then press Menu appears. CONFIGURATION
3
The Configuration
MENU
Symbologies Menu Communications Menu Terminal Menu
⁄
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 2455U.054
V
3. Press to choose the Terminal Menu and then press appears.
The Terminal Menu
TERMINAL MENU Append Time Beeper Display Keypad Power Management Preamble/Postamble RAM Drive Reader Command Menu Scanner _` Select item [Enter] Next screen [F1] Help [Esc] Exit 2455U.075
V
4. Press to choose the RAM Drive command and then press screen appears.
The RAM Drive
5. In the Size field, type the RAM drive size. Enter a value from 16 to 256 to configure RAM as drive E. If you do not want the terminal to create a RAM drive, enter a value of zero (0).
to save the changes and exit the RAM Drive screen. 7. Press ? to exit the Terminal Menu. The Configuration Menu appears. 8. Press ? to exit the Configuration Menu. 9. Press to choose Yes and save the new configuration in RAM. 10. Press ? to exit the TRAKKER Antares 2400 Menu System. 11. Press to choose Yes and store your changes permanently in flash memory. The 6. Press
RAM drive change must be saved in flash memory for the change to take effect.
3-23
Page 106
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget cCODE39
12. Press to choose OK and exit the TRAKKER Antares 2400 Menu System.
13. Scan this bar code to reset the terminal: Reset Firmware
*-.* *-.*
You can also send the Reset Firmware command over the network. For help, see Chapter 8, “Reader Command Reference.” Or, if the Resume Execution command is configured to resume “not allowed,” turn the terminal off and then back on to reset the terminal. Use the TRAKKER Antares 2400 Menu System to configure the Resume Execution command. Choose Terminal Menu from the Configuration Menu and then choose Power Management.
Configuring Flash Memory If you have a terminal with the 4MB flash memory option, you can configure the extra 2MB of the flash memory either to store double-byte fonts or as a 2MB drive. By default, the 2MB flash memory is configured to store a double-byte font set (up to 2MB maximum). If you are not using double-byte fonts, you can configure the 2MB flash memory as a storage drive (D). If you configure the flash memory as drive D, use this drive to store large lookup tables and data files (up to 32 files). To configure flash memory, you use the Flash Memory Configuration command. For help, see “Flash Memory Configuration” in Chapter 9. Note: You can only configure the 2MB (of the total 4MB) flash memory as a drive or to store fonts. You cannot use the space for both. If you configure drive D, you cannot store a font in flash memory. To configure flash memory to store double-byte fonts 1. Scan this bar code: Configure Flash Memory for Double-Byte Fonts
*$+FF0* *$+FF0*
2. Scan this bar code to save the configuration change in flash memory: Save Configuration in Flash Memory
*.+1* *.+1*
3-24
Page 107
nugget cCODE39Configuring the Terminal
3
3. Scan this bar code to boot the terminal and use the 2MB flash memory to store double-byte fonts: Reset Firmware
*-.* *-.*
Note: When you boot or reset the terminal, all files on drive D are destroyed. Flash memory is now configured to store double-byte fonts. 4. Use the TRAKKER Antares Font Editor to download the double-byte font set to the terminal. See your local Intermec sales representative for information about the TRAKKER Antares Font Editor. To configure flash memory as drive D 1. Scan this bar code: Configure Flash Memory as Drive D
*$+FF32* *$+FF32*
Note: A value of 32 configures drive D as a 2MB drive. 2. Scan this bar code to save the configuration change in flash memory: Save Configuration in Flash Memory
*.+1* *.+1*
3. Scan this bar code to boot the terminal and use flash memory as drive D: Reset Firmware
*-.* *-.*
Note: When you boot or reset the terminal, any fonts in flash memory are erased. Flash memory is now configured as drive D.
3-25
Page 108
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget cCODE39
Upgrading the Firmware The terminal firmware includes these items: •
TRAKKER Antares 2400 Menu System
•
Terminal emulation or sample application
•
TE Configuration Menu (3270, 5250, VT/ANSI terminals only)
•
Operating environment, firmware, and drivers
You can upgrade a terminal that has firmware version 2.x or higher to use the latest firmware version without making any hardware changes. There are two upgrade kits: Firmware Upgrade Kit
Part Number
Description
TRAKKER Antares TCP/IP
066814S
Order this kit for terminals that communicate in a TCP/IP direct connect network or a TCP/IP pass-through network.
TRAKKER Antares UDP Plus
067119S
Order this kit for terminals that communicate with a DCS 300 in a UDP Plus network.
To order a firmware upgrade kit, contact your local Intermec service representative. Each kit comes with a utility and instructions to upgrade the firmware on the terminal. Once you upgrade to the new firmware, you can use all the features described in this manual. Each kit comes with the new firmware version, the applications, the firmware upgrade utilities (DOS and Windows), and instructions about upgrading the terminal firmware. You can upgrade the firmware on the T2455 from a host computer or PC using serial communications. For help connecting the terminal, see “Connecting to Serial Devices” in Chapter 2 and “Using Serial Communications on the Terminal” in Chapter 4. Once the terminal is connected, you can upgrade the firmware. Note: You can also upgrade the firmware on one or more terminals using the Firmware Upgrade Utility on the DCS 300. For help, see the DCS 300 System Manual. To upgrade the firmware with the Windows utility 1. Connect the terminal to your PC. 2. From Program Manager, start the TRAKKER Antares Firmware Installation utility. The Firmware Installation utility screen appears. The Firmware Installation utility includes detailed online help. You click the Help button anytime to get more information.
3-26
Page 109
nugget cCODE39Configuring the Terminal
3
3. Choose the COM port, the Firmware Type (application), and the communications hardware type. 4. Choose OK. 5. On the TRAKKER Antares terminal, press label:
or scan this bar code
Enter Test and Service Mode
*..-.* *..-.*
The Main Menu appears. 6. Choose System Menu and press
The System Menu appears.
SYSTEM MENU File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware ⁄
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 2455U.046
7. Choose Upgrade Firmware and press
The Upgrade Firmware screen appears.
UPGRADE FIRMWARE Upgrade terminal firmware? Make sure the terminal is connected to a host.
OK
CANCEL 2455U.077
8. Choose OK to continue. 9. Choose Yes to continue and upgrade the firmware. The terminal reboots and then displays the Loader Waiting screen. To exit without upgrading the firmware, choose No.
3-27
Page 110
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget cCODE39
? f b
Note: If you reach the Loader Waiting screen and cannot upgrade or continue, press or to exit without upgrading the firmware. The Boot Menu appears. Press to boot the terminal and continue. 10. On your PC, make sure you selected the COM port and Firmware Type, and then choose OK. The PC downloads the firmware and application. Once the download is complete, the terminal boots and runs the application. Repeat these instructions to upgrade the firmware on another terminal. For help with the TRAKKER Antares firmware installation utilities, see the README.TXT instructions that ship with the utility or use the online help.
Recording Your Terminal’s Configuration The tables in this section list all the configuration parameters, their options, and where to find them in the Configuration Menu of the TRAKKER Antares 2400 Menu System. The default setting for each parameter is shown in bold italics. You should have an accurate record of the terminal’s configuration settings in case the terminal’s volatile memory and the configuration setup is lost. You can record the configuration on the following pages by circling the option you chose for each parameter or writing the value.
Bar Code Symbologies Table Parameter (Syntax)
Options
Location in Configuration Menu
Codabar (CD)
Disabled ABC Standard Concatenated
Symbologies Menu, Codabar option
• Start/Stop digit
Discard Retain ABCD Retain DC1-DC4
Code 11 (CG)
Disabled One check digit Two check digits
Symbologies Menu, Code 11 option
Code 16K (CP)
Disabled Standard Function code 1
Symbologies Menu, Code 16K option
Code 2 of 5 (CC)
Disabled 3 bar start/stop, label length 2 bar start/stop, label length
Symbologies Menu, 2 of 5, I2 of 5 option
3-28