The text of a manual · part 10 of 43
TRAKKER Antares 2455 Vehicle-Mount Terminal User's Manual, pages 91 to 100
Pages 91 to 100 of 422
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2455
Page 91
3 nugget cCODE39Configuring the Terminal
File Manager Lets you manage the files on each drive. You can run an application from drive C, delete a file from any drive, or rename a file on any drive. For help using the File Manager, see “Running the Application on the Terminal” in Chapter 5. Load Default Values Lets you load the default configuration values. For help, see “Restoring the Terminal’s Default Configuration” later in this chapter. Set Time and Date Lets you set the current time and date. For help, see “Setting the Time and Date” in Chapter 2. Store Configuration Stores the current configuration in flash memory, including any changes you have made in the menu system. When you exit the TRAKKER Antares 2400 Menu System, you will also be prompted to save your changes. For help, see “Exiting the TRAKKER Antares 2400 Menu System” later in this chapter. Upgrade Firmware Lets you upgrade the system firmware on the terminal. For help, see “Upgrading the Firmware” later in this chapter. You can use the keystrokes described next to move around in the TRAKKER Antares 2400 Menu System, or you can scan bar code labels. For a list of bar code labels, see the “Full ASCII Bar Code Chart” in Appendix B.
Selecting Menus and Commands
: V
Press or to choose a menu name from the Main Menu. Then press to display the commands in the selected menu. In this example, you press to display the System Menu: MAIN
MENU
SYSTEM
MENU
Configuration Menu Diagnostics Menu System Menu About TRAKKER 2400
File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware
_` Select item [Enter] Next screen [F1] Help [Esc] Exit
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 2455U.067
: V
Press or to choose a command or option from a menu, and then press execute the command or option. Note: You can press screen.
b at any time to display a help screen. Press ? to exit a help
3-9
Page 92
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget cCODE39
Filling In Fields and Marking Check Boxes Screens list the options for each configuration parameter, diagnostic, or system option. Below each option name is either a toggle field or an entry field:
; , W , or to view the options for that field. • In an entry field, you type a value into the field. To edit the data in an entry field, use the ; , W , d , or keys. You can also use the Delete ( ) and Insert ( ) keys to edit an entry field. •
In a toggle field, you press d
Note: If you have a T2455 with 5250 terminal emulation (TE), there is no Backspace key ( ). Use the other keys listed here to edit data in an entry field in the TRAKKER Antares 2400 Menu System or the TE Configuration menu.
For example, the Code 49/Code 16K screen has toggle and entry fields. The Code 49 field is a toggle field. Press to toggle between Enabled and Disabled. The Function Codes fields for F1, F2, and F3 are entry fields. Type a value into the field for each function code. CODE Code
49 49:
/
CODE
16K
Enabled
Code 49 Function Codes: F1: F2: \x0D\x0A F3: Code 16K: Standard OK
CANCEL 2455U.068
To move to the next field •
Press
V or
To move to the previous field •
Press
:.
Some screens contain check boxes. Check boxes are used when you can select more than one option at a time.
3-10
Page 93
nugget cCODE39Configuring the Terminal
3
To mark or clear check boxes •
Press . For example, to disable the Backspace reader command, choose the Backspace check box and press to clear the check box. READER COMMAND MENU [Space] to enable or disable a command [X] Abort Program [X] Backlight [X] Backspace [X] Change Config [X] Clear [X] Default Config [X] Delete File [X] Enter Accum [X] Exit Accum [X] List Files
[X] [X] [X] [X] [X] [X] [X] [X] [X]
Multi-Read Receive File Rename File Reset Run Program Scanner On Scanner Off Test & Service Transmit File
OK
CANCEL more
_
2455U.069
Entering ASCII Control Characters You can include ASCII control characters in a postamble or preamble by using the TRAKKER Antares 2400 Menu System. For a definition of the postamble or preamble, see Chapter 9, “Configuration Command Reference.” You can configure the postamble or preamble to be characters from the full or extended ASCII character sets. For example, the Field Exit code (Ü) for 5250 terminal emulation is an extended ASCII character that is often configured as the postamble. For a list of the full and extended ASCII characters, see Appendix B, “Full ASCII Charts,” or the TRAKKER Antares Terminal Emulation User’s Guide. Note: For more help on using the 5250 Field Exit code, see “Auto-Advancing Through Fields on 5250 TE Screens” in the TRAKKER Antares Terminal Emulation User’s Guide. To enter ASCII characters for a preamble or postamble 1. Decide which ASCII control character you want to set for the preamble or postamble. Look up the control character in the Full ASCII Table in Appendix B and find the two-digit hexadecimal number. For example, ETX in the Full ASCII Table is the hexadecimal value 03. To enter an extended ASCII character, look up the hexadecimal number for the character in the “TRAKKER Antares Terminal Font Set” in Appendix C. For example, 9A is the hexadecimal value for Ü, the 5250 Field Exit code. 2. Use the TRAKKER Antares 2400 Menu System to configure a preamble or postamble. From the Main Menu, choose Configuration Menu.
3-11
Page 94
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget cCODE39
3. From the Configuration Menu, choose Terminal Menu. 4. From the Terminal Menu, choose Preamble/Postamble. PREAMBLE
/
POSTAMBLE
Preamble: abc Postamble: \x0D\x0A
OK
CANCEL 2455U.070
5. Move the cursor to the field for the preamble or postamble. 6. Type the control character, extended ASCII character, or escape character sequence in the preamble or postamble field. •
To type a control character or extended ASCII character in the preamble or postamble field, use this syntax: \xhh where hh is the one or two-digit hexadecimal number for the control character or extended ASCII character. For example, to enter ETX as a preamble, type: \x03
To enter Ü (5250 Field Exit code) as the postamble, type: \x9A
•
To type an escape character (backslash) in the preamble or postamble field, use the next table. The application ignores the first backslash (\) character and saves the next character(s). For example: Enter These Characters
Preamble/Postamble Saved
\\
\
\h h
\x x
\\k
\k
\ no data
7. Press
3-12 or choose OK to save your changes and exit the screen.
Page 95
nugget cCODE39Configuring the Terminal
8. Choose another menu from the Terminal Menu or press Configuration Menu appears.
3
? to exit. The
For help exiting the menu system, see “Exiting the Configuration Menu” later in this chapter.
Exiting Screens and Saving Changes When you exit a screen, you can save or discard your changes: Task
Description
To exit a screen and save the changes
Choose OK and press . Or, press with the cursor in any field except the Cancel button.
To exit a screen and discard the changes
Choose Cancel and press Or, press ? with the cursor in any field.
Exiting the Configuration Menu
?
1. Press to exit the Configuration Menu. If you have made any changes to the current configuration, this screen prompts you to save the new configuration in RAM. The current configuration (also called the runtime configuration) is the set of parameters currently enabled on the terminal.
3. Choose another menu from the Main Menu or press ? to exit the TRAKKER
2. Choose Yes and press to save your changes in RAM and update the current configuration on the terminal. Choose No and press to exit without changing the configuration. The Main Menu appears. Antares 2400 Menu System.
For help exiting the menu system, see the next procedure for “Exiting the TRAKKER Antares 2400 Menu System.”
3-13
Page 96
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget cCODE39
Exiting the TRAKKER Antares 2400 Menu System
?
1. From the Main Menu, press . If you have made any changes, the next screen prompts you to store the changes in flash memory. You can also save the runtime configuration in flash memory by choosing the Store Configuration command from the System Menu. For help, see “Saving Configuration Changes in Flash Memory” later in this chapter. Note: When you boot or reset the terminal, it uses the configuration you last saved in flash memory.
Store configuration changes in flash memory? (used when rebooting the terminal)
Yes
No
CANCEL
2455U.072
2. Choose Yes and press to save your changes in flash memory. Choose No and press to exit without saving. The Exiting TRAKKER Antares 2400 Menu System screen appears. Note: If you changed the configuration, you were prompted to save your changes in RAM as you exited the Configuration Menu. If you want the configuration changes to be stored in flash memory, you need to choose Yes in this screen.
3. Choose OK and press to exit the TRAKKER Antares 2400 Menu System. Choose Cancel and press to return to the Main Menu. After you exit the menu system, the terminal will resume the application you were running when you started the menu system.
3-14
Page 97
nugget cCODE39Configuring the Terminal
3
Configuring the Terminal by Scanning Bar Codes You can configure the terminal by scanning bar code labels listed in this manual or by creating your own Code 39 or Code 93 bar code labels. For help, see Chapter 9, “Configuration Command Reference.” Note: If you are working in the TRAKKER Antares 2400 Menu System, you cannot scan configuration commands. Exit the menu system to scan configuration commands. For example, you can use the Beep Volume configuration command to adjust the volume of the terminal’s audio signals. You can scan this bar code label to set the beep volume to a quiet audio level: Set Beep Volume to Quiet
*$+BV1* *$+BV1*
You can create bar code labels that contain more than one configuration command. For example, you can create one bar code label to configure the terminal for: •
One-Shot Scanner mode (SB0)
•
Scanner Redundancy set to high (SR2)
•
Beep Volume set to very loud (BV4)
•
Disable Keypad Clicker (KC0)
One-Shot Scanner Mode, Set Scanner Redundancy to High, Set Beep Volume to Very Loud, Disable Keypad Clicker
*$+SB0SR2BV4KC0* *$+SB0SR2BV4KC0*
To configure these same four configuration commands, you can scan four separate bar code labels in Chapter 9, “Configuration Command Reference.” When you create a bar code label to set several configuration commands, follow these rules: •
The bar code label must be printed using Code 39 or Code 93 symbology.
•
The bar code label must include the start and stop character. Most bar code printing utilities automatically include the start and stop character.
•
The bar code label must start with $+ (Change Configuration command).
•
Each configuration command must include the command syntax and the value for the command. For example, BV is the command syntax for Beep Volume and the value 4 sets the beep volume to very loud.
3-15
Page 98
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget cCODE39 •
If you set one configuration command to a string of ASCII characters and another configuration command follows, you must enclose the value in quotes. If you do not include the quotation marks, the terminal will interpret everything after the first command as data and will not find the second configuration command. For example, to set the preamble to BV, use $+ADBV (no quotes are needed). To set the preamble to BV and turn off the beep volume, use $+AD"BV"BV0, or change the order and use $+BV0ADBV. To clear the preamble and postamble from a single label, use $+AD""AE. Note: To scan a Code 39 bar code label that includes quotes, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” in Chapter 9.
•
To include quotation marks when you set a value, the entire value must be enclosed in quotation marks. Type two sets of quotation marks ("") to include one quotation mark as the value for a command. For example, to set the preamble to ABC"D, use $+AD"ABC""D".
When you scan bar code labels, you change the terminal’s current runtime configuration. The changes are not saved in the terminal flash memory. To save the changes in flash memory, scan this bar code label: Save Configuration in Flash Memory
*.+1* *.+1*
You can also use the TRAKKER Antares 2400 Menu System. For help, see “Saving Configuration Changes in Flash Memory” later in this chapter.
3-16
Page 99
nugget cCODE39Configuring the Terminal
3
Scanning Bar Codes to Enable Symbologies The TRAKKER Antares 2455 terminal can decode several different types of bar code symbologies. Each symbology, such as Code 39, uses a different scheme for encoding data as bar code. You must configure the terminal to decode the bar code symbology used in your bar code labels. Only enable the bar code symbologies that you need to scan. For more information about each symbology and the configuration options, see Chapter 9, “Configuration Command Reference.” The terminal can decode the bar code symbologies shown in the next table. You can scan the bar code labels in the table to enable a symbology. Note: Only three symbologies, Code 39, Code 128, and UPC/EAN, are enabled when you unpack the terminal. Bar Code Symbology
Enabled?
To Enable the Symbology
Codabar
No
Enable Standard Codabar, ABCD Start/Stop Code
*$+CD21* *$+CD21* Code 11
No
Enable Code 11 With Two Check Digits
*$+CG2* *$+CG2* Code 16K
No
Enable Standard Code 16K
*$+CP1* *$+CP1* Code 2 of 5
No
Enable Code 2 of 5, 3 Bar Start/Stop, Label Length of 1
*$+CC001* *$+CC001* Interleaved 2 of 5 (I 2 of 5)
No
Enable I 2 of 5, Variable Length With a Check Digit
*$+CA99* *$+CA99*
Note: You can enable either Code 2 of 5 or Interleaved 2 of 5. If you enable I 2 of 5, Code 2 of 5 is automatically disabled and vice versa.
3-17
Page 100
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget cCODE39
Scanning Bar Codes to Enable Symbologies (continued) Bar Code Symbology
Enabled?
To Enable the Symbology
Code 39
YES
Enable Code 39 Full ASCII With No Check Digit
*$+CB111* *$+CB111* Code 49
No
Enable Code 49
*$+CJ1* *$+CJ1* Code 93
No
Enable Code 93
*$+CF1* *$+CF1* Code 128
YES
Enable Standard Code 128
*$+CH1* *$+CH1* MSI
No
Enable MSI Without Check Digits
*$+CN10* *$+CN10* Plessey
No
Enable Plessey With Reverse Start Code
*$+CI10* *$+CI10* UPC/EAN
YES
Enable UPC-A/EAN-13, UPC-E, EAN-8
*$+CE1111111* *$+CE1111111*
3-18