Page 77
4
Troubleshooting and Maintaining the Terminal
This chapter lists problems you may encounter while using the terminal and provides some possible solutions. It also describes how to boot or reset the terminal and clean the scanner window and terminal screen. This chapter covers these topics: • Problems while operating the terminal • Problems while configuring the terminal • Problems while configuring 802.1x security • Problems communicating with RF network devices • Problems while running applications • Problems transmitting data through the serial port • Problems transmitting data through the DCS 30X • Problems scanning bar code labels • Booting the terminal • Troubleshooting a locked up application • Resetting the terminal • Cleaning the scanner window and terminal screen
Trakker Antares 243X Handheld Terminal User’s Manual
63
Page 78
Chapter 4 - Troubleshooting and Maintaining the Terminal nugget
39
How to Use This Chapter If you have any problems using the 243X, use this chapter to find a possible solution. You can also use the error numbers and messages table and the terminal diagnostics to help analyze and solve problems. For help, see Chapter 4, “Running Diagnostics,” in the Trakker Antares 2400 Family System Manual (P/N 071389). If you have problems with the TE 2000 terminal emulation applications, see the appropriate TE 2000 guide. If you send the terminal in for service, it is your responsibility to save the terminal data and configuration. Intermec is only responsible for ensuring that the keypad and other hardware features match the original configuration when repairing or replacing your terminal.
Problems While Operating the Terminal If you are operating the terminal and have trouble, check these possible problems and solutions. Problems While Operating the Terminal Problem You cannot scan bar code labels.
Solution See “Problems Scanning Bar Code Labels” on page 77.
The terminal is booting and you see a message that POST failed.
The screen displays the system that failed POST. Report the error message to your supervisor. Press e to exit the error message. The Boot Menu appears. Press 1 to boot the terminal. Your application appears on the screen. If the terminal still will not boot, contact your local Intermec service representative for help.
You press f or ' to turn on the terminal and the screen is blank and nothing happens.
The battery pack may not be installed correctly. For help, see “Installing the Battery Pack” on page 9.
You are scanning bar code labels, and the terminal appears to be operating slowly.
The terminal may be configured for the 5x6, 5x8, 6x8, or 12x16 font type. These font type values may cause the 243X to scroll, and therefore operate, more slowly when it displays bar code values on the screen. Change the font type to a value other than 5x6, 5x8, 6x8, or 12x16. For help, see “Display Font Type” or “Display Spacing” in Chapter 6 of the 2400 Family system manual. If the terminal continues to operate slowly, contact your local Intermec service representative for help.
You are sending and receiving information through the network, and the terminal appears to be operating slowly.
The terminal may be configured for the 5x6, 6x8, or 12x16 font type. These font type values may cause the 243X to scroll, and therefore operate, more slowly when it displays information on the screen. Change the font type to a value other than 5x6, 6x8, or 12x16. For help, see “Display Font Type” or “Display Spacing” in Chapter 6 of the 2400 Family system manual. If the terminal continues to operate slowly, contact your local Intermec service representative for help.
64
The battery pack may be discharged. Replace the battery pack with a spare charged battery pack, or charge the battery pack and try again.
Trakker Antares 243X Handheld Terminal User’s Manual
Page 79
nugget
39 Chapter 4 - Troubleshooting and Maintaining the Terminal
Problems While Operating the Terminal (continued) Problem You scan a reader command, such as Change Configuration, and nothing happens.
Solution The reader commands are disabled. Scan the Enable Override command shown here to temporarily enable all of the reader commands. You can also enable or disable reader commands with the TRAKKER Antares 2400 Menu System. For help, see “Command Processing” in Chapter 6 of the 2400 Family system manual. When you are finished, remember to disable the override so that your data is not interpreted as a command. Enable Override
*$+DC3* *$+DC3* The terminal displays the Boot Menu.
The Boot Menu appears if you just upgraded the firmware on the terminal and POST failed. Press 1 to boot the terminal. Report the problem to your supervisor. If the main battery was removed from the terminal for an extended period of time, when you replace the main battery, the Boot Menu appears. Press 1 to boot the terminal and continue working. For help, see “Booting the Terminal” on page 78.
You scan a reader command, such as Change Configuration, and nothing happens.
The reader commands are disabled. Scan the Enable Override command shown here to temporarily enable all of the reader commands. You can also enable or disable reader commands with the TRAKKER Antares 2400 Menu System. For help, see “Command Processing” in Chapter 6 of the 2400 Family system manual. When you are finished, remember to disable the override so that your data is not interpreted as a command. Enable Override
*$+DC3* *$+DC3* You scan a valid bar code label to enter data for your application. The data decoded by the terminal does not match the data encoded in the bar code label.
The terminal may have decoded the bar code label in a symbology other than the label’s actual symbology. Try scanning the bar code label again. Make sure you scan the entire label.
You want to restore the terminal’s default configuration so that you can reconfigure the terminal.
Scan this bar code label: Default Configuration
To operate the 243X quickly and efficiently, you should enable only the bar code symbologies that you are going to scan. If you enable multiple symbologies, the 243X may, on rare occasions, decode a bar code according to the wrong symbology and produce erroneous results.
*.+* *.+*
You can also use the TRAKKER Antares 2400 Menu System. For help, see “Restoring the Terminal’s Default Configuration” in Chapter 2 of the 2400 Family system manual. After you load the default configuration, you may need to set the primary network communications parameters to communicate with other devices in the network.
Trakker Antares 243X Handheld Terminal User’s Manual
65
Page 80
Chapter 4 - Troubleshooting and Maintaining the Terminal nugget
39
Problems While Operating the Terminal (continued) Problem The terminal appears to be locked up and you cannot enter data.
Solution Try these possible solutions:
• (2435 only) Wait at least 10 seconds and try again. If the 2435 is still connecting to the DCS 30X or host, it will ignore any input from the keypad or scanner. Make sure the Network Connect status icon is on before continuing.
• Scan a bar code label to see if the terminal responds. • Follow the instructions in “Troubleshooting a Locked Up Application” on page 80.
• If the terminal will not boot or reset, contact your local Intermec service representative for help.
Problems While Configuring the Terminal If you have trouble configuring the terminal, check these possible problems and solutions. Problems While Configuring the Terminal Problem On the 2435, you configure the security ID and the changes do not appear to be saved.
Possible Solution You can only set the security ID with the RF network enabled. The Network Activate command must be set to the RF network before you can save any changes to the Security ID command.
You are configuring SOM or EOM in the Configuration Menu and cannot set two characters.
You may have a space in the SOM or EOM field. The space does not show, but it is a valid character. To delete a space from the field, put the cursor in the field and press l n, or press the orange > key and then the green > key, or press the green key and D. Now set the two-character value for SOM or EOM.
You are scanning a configuration command to set one of the serial port parameters and hear three low beeps. For example, you are trying to set EOM or SOM.
The order in which you scan serial port protocol configuration commands is important. Configurable Serial Port (CSP) protocol uses EOM to determine the serial communications mode. When EOM is disabled, the terminal communicates in Character mode. When EOM is enabled, the terminal communicates in Frame mode. To use Frame mode, you need to set EOM first. Next, configure Handshake, Configuration Commands Via Serial Port, LRC, SOM, and then Poll. To use Character mode, you need to disable these same parameters in reverse order. For help, see “Using Serial Communications on the Terminal” on page 51.
You scan or enter an option for the Scanner Selection configuration command and you hear three low beeps.
66
You may have scanned or entered a Scanner Selection command that does not apply to the type of scanner that you have installed. Try scanning or entering the Scanner Selection command again and select an option for the type of module you have installed.
Trakker Antares 243X Handheld Terminal User’s Manual
Page 81
nugget
39 Chapter 4 - Troubleshooting and Maintaining the Terminal
Problems While Configuring the Terminal (continued) Problem You scan a configuration command, such as Keypad Caps Lock, and nothing happens.
Possible Solution One or more reader commands, such as Change Configuration, may be disabled, so that you cannot change the configuration. Enable all of the reader commands and try again. The terminal may be waiting for another command to complete the configuration change. If you started by scanning the Enter Accumulate command, you must finish the command by scanning the Exit Accumulate command. For help, see Chapter 6, “Configuration Command Reference,” in the 2400 Family system manual. Scan Enable Override to temporarily enable all of the reader commands. When you are finished, remember to disable the override so that your data is not interpreted as a command. Enable Override
*$+DC3* *$+DC3* On the 2435, you scan a configuration command to set one of these parameters and hear three low beeps:
• Controller IP Address (UDP Plus) or Host IP Address (TCP/IP)
• Terminal IP Address • Default Router • Network Activate
If the Network Activate command is enabled (RF network enabled) and you are configuring the 2435, these IP addresses must define a valid network configuration. For example, an invalid network configuration would be a controller (or host) IP address set to 0.0.0.0 with the network enabled. To set these four parameters, follow these steps:
1 Disable the Network Activate (NA) configuration command. 2 Set the terminal IP address and the controller IP address or the host IP address.
3 Set the default router address (if necessary). 4 Enable the Network Activate command. You can change an IP address with the network enabled as long as it still defines a valid network configuration. You scan a configuration command, such as Keypad Caps Lock, and you hear three low beeps.
If you are working in the TRAKKER Antares 2400 Menu System, you cannot scan configuration commands. Use the Configuration Menu to change the terminal’s configuration, or exit the menu system to scan configuration commands. Check the command you are trying to scan. Make sure the command is set correctly for the options and network communications you are using with the terminal. For help, see Chapter 6, “Configuration Command Reference,” in the 2400 Family system manual.
You are configuring the serial port and see this error message when exiting the Configuration Menu: Serial port configuration error. SOM cannot equal EOM. Configuration was not updated.
SOM cannot equal the same value that is set for EOM. You cannot set SOM to any of these values: AFF (ACK), DLE, NEG (NAK), Poll, RES (EOT), REQ (ENQ), SEL, XOFF, or XON. You need to change the value of SOM. Choose Serial Port from the Communications Menu. For help, see “Start of Message (SOM)” in Chapter 6, “Configuration Command Reference,” in the 2400 Family system manual.
Trakker Antares 243X Handheld Terminal User’s Manual
67
Page 82
Chapter 4 - Troubleshooting and Maintaining the Terminal nugget
39
Problems While Configuring the Terminal (continued) Problem You are configuring the serial port and see this error message when exiting the Configuration Menu: Serial port configuration error. DLE, XON, XOFF are not valid values for either SOM or EOM. Configuration was not updated. You are configuring the serial port and see this error message when exiting the Configuration Menu: Serial port configuration error. EOM #1 cannot equal EOM #2. Configuration was not updated.
Possible Solution EOM or SOM cannot be set to any of these values: AFF (ACK), DLE, NEG (NAK), Poll, RES (EOT), REQ (ENQ), SEL, XOFF, or XON. You must change the value of EOM or SOM. Choose Serial Port from the Communications Menu. For help, see “End of Message (EOM)” or “Start of Message (SOM)” in Chapter 6, “Configuration Command Reference,” in the 2400 Family system manual. EOM can be one or two ASCII characters, but the value for the first character cannot be the same as the value for the second character. Also, EOM cannot be set to any of these values: AFF (ACK), DLE, NEG (NAK), Poll, RES (EOT), REQ (ENQ), SEL, XOFF, or XON. You must change the value of EOM #1 or #2. Choose Serial Port from the Communications Menu. For help, see “End of Message (EOM)” in Chapter 6, “Configuration Command Reference,” in the 2400 Family system manual.
You are configuring the serial port and see this error message when exiting the Configuration Menu:
You must configure a value for EOM before you can set SOM or disable SOM. You need to change the value of SOM. Choose Serial Port from the Communications Menu.
Serial port configuration error.
Configurable Serial Port (CSP) protocol uses EOM to determine the serial communications mode. When EOM is disabled, the terminal communicates in Character mode. When EOM is enabled, the terminal communicates in Frame mode.
SOM is set. You must also set EOM. Configuration was not updated.
To use Frame mode, you need to set EOM first. Next, configure Handshake, Configuration Commands Via Serial Port, LRC, SOM, and then Poll. To use Character mode, you need to disable these same parameters in reverse order. For help, see “Using Serial Communications on the Terminal” on page 51.
You see this error message when exiting the Configuration Menu:
The two-character name (syntax) of the configuration command that failed is listed on the first line of the error message.
Commandname command failed.
Check the command listed in the message. To find the command, use the “Configuration Commands by Syntax” table in Appendix A of the 2400 Family system manual. Make sure the command is set correctly for the options and network communications you are using with the terminal. For help, see Chapter 6, “Configuration Command Reference,” in the 2400 Family system manual. For example, you may see this message:
Remainder of configuration not updated.
SS command failed. There may be a problem with the configuration due to a change made with the Scanner Selection (SS) command. You are configuring a 243X with the clone application and see an error message.
68
The server terminal and the client terminal may not have the same hardware or software configuration. Make sure that both terminals have the same hardware configuration, firmware version, and clone application version. For help, see “Configuring the Terminal With the Clone Application” in Chapter 2 of the 2400 Family system manual.
Trakker Antares 243X Handheld Terminal User’s Manual
Page 83
nugget
39 Chapter 4 - Troubleshooting and Maintaining the Terminal
Problems While Configuring the Terminal (continued) Problem You are configuring the serial port and see this error message when exiting the Configuration Menu:
Possible Solution PG is the Handshake configuration command. You must change the value of Handshake or set other serial port parameters. Choose Serial Port from the Communications Menu.
PG command failed.
The order in which you set serial port protocol configuration commands is important. To use Frame mode, you need to set EOM first. Next, configure Handshake, LRC, SOM, and then Poll. To use Character mode, you must disable these parameters in reverse order. For help, see “Using Serial Communications on the Terminal” on page 51.
Configuration was not updated.
On the 2435, you see this error message when exiting the Configuration Menu: Network configuration error. Network is enabled. Terminal IP address or Controller (Host) IP address set to an invalid address of 0.x.x.x or 127.x.x.x. Configuration was not updated.
The RF network is enabled and there is a problem with the network configuration. You must change the terminal IP address, the controller IP address (host IP address for a TCP/IP network), or both. Choose Primary Network from the Communications Menu. The terminal IP address or the controller/host IP address is set to 0.x.x.x or 127.x.x.x. These are invalid addresses. Set a valid IP address for the terminal and DCS 30X or host. For help, see “Using RF Communications on the 2435” on page 54. If you cannot fix the addressing problem, check with your network administrator to get the IP address assigned to the terminal and the DCS 30X or host.
On the 2435, you see this error message when exiting the Configuration Menu: Network configuration error. Network is enabled. Terminal IP address and Default Router address set to the same address. Configuration was not updated.
The RF network is enabled and there is a problem with the network configuration. You must change the terminal IP address, the default router address, or both. Choose Primary Network or Advanced Network from the Communications Menu. The terminal IP address and the default router address are both set to the same address. Set a valid IP address for the terminal and the default router. For help, see “Using RF Communications on the 2435” on page 54. If you cannot fix the addressing problem, check with your network administrator to get the IP addresses for each RF network device.
On the 2435, you see this error message when exiting the Configuration Menu: Network configuration error. Network is enabled. Default Router address is not on the terminal’s network. Configuration was not updated.
The RF network is enabled and there is a problem with the network configuration. You must change the default router address. Choose Advanced Network from the Communications Menu. The terminal and DCS 30X (UDP Plus or WTP network) or host (TCP/IP network) are on different networks, and the terminal is not on the same network as the default router. When the terminal is on a different IP subnetwork from the DCS 30X or host, you must set the Default Router and Subnet Mask commands. Set a valid IP address for terminal, DCS 30X or host, and default router. For help, see “Using RF Communications on the 2435” on page 54. If you cannot fix the addressing problem, check with your network administrator to get the IP addresses for each network device.
Trakker Antares 243X Handheld Terminal User’s Manual
69
Page 84
Chapter 4 - Troubleshooting and Maintaining the Terminal nugget
39
Problems While Configuring the Terminal (continued) Problem On the 2435, you see this error message when exiting the Configuration Menu: Network configuration error. Network is enabled. Terminal IP address or Controller (Host) IP address set to the same address. Configuration was not updated.
Possible Solution The RF network is enabled and there is a problem with the network configuration. You must change the terminal IP address, the controller IP address (host IP address for a TCP/IP network), or both. Choose Primary Network from the Communications Menu. The terminal IP address and the controller/host IP address are both set to the same address. Set a valid IP address for the terminal and DCS 30X or host. For help, see “Using RF Communications on the 2435” on page 54. If you cannot fix the addressing problem, check with your network administrator to get the IP address assigned to the terminal and the DCS 30X or host.
Problems While Configuring 802.1x Security If you have trouble configuring the terminal for 802.1x TTLS or LEAP security, check these possible problems and solutions. For more error numbers and messages, see “802.1x Security Error Numbers and Messages” in Chapter 4 of the 2400 Family system manual. This section references error numbers that are displayed on the Error Logger screen in the TRAKKER Antares 2400 Menu System. To view the Error Logger screen, from the Main Menu, choose Diagnostics Menu, Software Diagnostics, and then Error Logger. Problems While Configuring 802.1x Security Problem You are configuring 802.1x TTLS security. The “AUTHENTICATING” message does not appear on the screen, and the Network Connect status icon is not on.
Possible Solution The terminal may not be communicating with your MobileLAN access point. Make sure that:
• the network name on the terminal is the same as the network name (SSID) of the access point that you are trying to communicate with. The default network name is “INTERMEC.”
• the Network Activate command is enabled on your terminal. The 802.1x security network may not be active. Make sure that the Odyssey server software is properly loaded and configured on the server PC. For help, see the documentation that shipped with your server software. You are configuring 802.1x TTLS security. The “AUTHENTICATING” message appears on the screen, but the terminal does not emit a low beep and a high beep to indicate that it is authenticated.
70
The terminal takes up to 60 seconds to authenticate; however, this process may take longer if there is interference in RF communications. You may need to wait for the authentication process to finish. You may be out of range of the MobileLAN access point that you are trying to communicate with. Try moving closer to the MobileLAN access point.
Trakker Antares 243X Handheld Terminal User’s Manual
Page 85
nugget
39 Chapter 4 - Troubleshooting and Maintaining the Terminal
Problems While Configuring 802.1x Security (continued) Problem You are configuring 802.1x TTLS or LEAP security. The terminal indicates that it is authenticated by emitting a low beep and a high beep, but it does not communicate with the host.
Possible Solution Make sure that the terminal IP address, host IP address, subnet mask, and default router are properly configured for your network. Note: Do not cold boot the terminal. Cold booting the terminal resets the time and date.
You are configuring 802.1x TTLS security. The “AUTHENTICATING” message does not appear on the screen. The Network Connect status icon turns on, but it does not stay on.
The terminal may not be communicating with the MobileLAN access point that you want it to communicate with. Make sure that the network name on the terminal is the same as the network name of the access point that you are trying to communicate with. The default network name is “INTERMEC.” The MobileLAN access point that you are trying to communicate with may not be communicating with the Odyssey server. Make sure your MobileLAN access point is turned on, properly configured, and has 802.1x security enabled.
You are configuring 802.1x TTLS or LEAP security. The terminal indicates that it is not authenticated by emitting a high beep and a low beep. This error code appears on the Error Logger screen: 0x377
Make sure that:
• the User Name and Password parameters on your terminal match the user name and password on your server. You may need to re-enter the password on both your terminal and server.
• on an Odyssey server, the user and group are allowed and the group policy is allowed to log in to the Odyssey server. For help, see the documentation that shipped with your Odyssey server software.
• the IP address and secret key for your access point must match the IP address and secret key on your server. You may need to re-enter the IP address and secret key on both your access point and server.
• your server is active and that it can communicate with your access point. You can use the PING command to determine communications.
• the server software is running on the server PC. • the UDP port (standard RADIUS port, 1812) on your server is active. For help, see the documentation that shipped with your server software. You are having trouble downloading the 802.1x TTLS security option. This error code appears on the Error Logger screen: 0x037E
802.1x TTLS security requires your terminal to have the 4MB flash memory option. To upgrade your terminal with the 4MB flash option, contact your local Intermec representative.
Trakker Antares 243X Handheld Terminal User’s Manual
71
Page 86
Chapter 4 - Troubleshooting and Maintaining the Terminal nugget
39
Problems While Configuring 802.1x Security (continued) Problem You are having trouble downloading the 802.1x TTLS security option. This error code appears on the Error Logger screen: 0x037E You are configuring 802.1x TTLS security. The “AUTHENTICATING” message appears on the screen, but the terminal does not emit a low beep and a high beep to indicate that it is authenticated.
Possible Solution 802.1x TTLS security requires your terminal to have the 4MB flash memory option. Make sure that your terminal has the 4MB flash memory option
The authentication process timed out. You may be out of range of the MobileLAN access point that you are trying to communicate with. Try moving closer to the MobileLAN access point.
This error code appears on the Error Logger screen: 0x37B The terminal indicates that it is not authenticated by emitting a high beep and a low beep. This error code appears on the Error Logger screen: 0x542
Neither of the server certificate common names configured on your terminal matches the server certificate common name in the active server certificate on your Odyssey server:
• Delete both server certificate common names on your terminal to see if you can authenticate without checking the server certificate common name.
• Change one or both server certificate common names on your terminal so that they match the server certificate common names in the active server certificate on your Odyssey server. For help, see “Server Certificate Common Name” in Chapter 6 of the 2400 Family system manual. The terminal indicates that it is not authenticated by emitting a high beep and a low beep.
The root Certificate Authority certificate on your terminal cannot validate the server certificate:
This error code appears on the Error Logger screen: 0x513
• Make sure your Odyssey server is using a server certificate that matches the root certificate loaded on your terminal.
• Verify the root certificate in the CACERT.PEM file on your terminal’s C drive. For help, see the documentation that shipped with your Odyssey server software.
72
Trakker Antares 243X Handheld Terminal User’s Manual