The text of a manual · part 10 of 12
Trakker Antares 243X Handheld Terminal User's Manual: Chapter 4 - Troubleshooting and Maintaining the Terminal, pages 87 to 96
Pages 87 to 96 of 114, from Trakker Antares 243X Handheld Terminal User's Manual
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2435
Page 87
nugget
39 Chapter 4 - Troubleshooting and Maintaining the Terminal
Problems Communicating With RF Network Devices If the 2435 is not communicating with other devices in the RF network, check these possible problems. Problems Communicating With RF Network Devices Problem The Network Connect status icon is off. The 2435 is not communicating with the access point.
Possible Solution Make sure the access point is turned on and operating. You may also be using the terminal out of range of an access point. Try moving closer to an access point to re-establish communications. If you are using a 21XX access point with firmware release 1.34 or earlier, it may not be able to communicate with the terminal. For help upgrading your access point firmware, see the MobileLAN access System Manual (P/N 067150). In a TCP/IP direct connect network, you cannot scan or enter data when the 2435 is not communicating with an access point or you may lose your TCP session. Make sure the Network Activate command is enabled. For help, see “Network Activate” in Chapter 6 of the 2400 Family system manual. Make sure the 2435 is configured correctly for your network. The radio parameters on the terminal must match the values set for all access points the terminal may communicate with. For help, see “Using RF Communications on the 2435” on page 54. If you have an 802.11b radio, the radio initialization process may have failed. Try resetting the terminal. For help, see “Resetting the Terminal” on page 81. If you have tried these possible solutions and the Network Connect status icon is still off, you may have a defective radio card. For help, contact your local Intermec service representative.
You are sending and receiving information through the network, and the terminal appears to be operating slowly.
The terminal may be configured for the 5x6, 6x8, or 12x16 font type. These font type values may cause the 243X to scroll, and therefore operate, more slowly when it displays information on the screen. Change the font type to a value other than 5x6, 6x8, or 12x16. For help, see “Display Font Type” or “Display Spacing” in Chapter 6 of the 2400 Family system manual. If the terminal continues to operate slowly, contact your local Intermec service representative for help.
The Network Connect status icon is on, but the host computer is not receiving any data from the 2435.
In a UDP Plus or WTP network, there may be a problem with the connection between the DCS 30X and the host computer. Check with your network administrator or use the user’s manual for the DCS 30X to troubleshoot any potential problems with the server. In a TCP/IP network, there may be a problem with the connection between the access point and the host computer. Check with your network administrator or use your access point user’s manual to troubleshoot any potential problems with the access point.
Trakker Antares 243X Handheld Terminal User’s Manual
73
Page 88
Chapter 4 - Troubleshooting and Maintaining the Terminal nugget
39
Problems Communicating With RF Network Devices (continued) Problem The Network Connect status icon blinks on the terminal screen.
Possible Solution In a UDP Plus or WTP network, the terminal is communicating with an access point, but it is not connected to the DCS 30X. You may need to check the 2435 configuration or make sure the DCS 30X is running and that data collection is started. The 2435 may be out of range of an access point or the access point may have recently been turned off. Make sure the access point is still turned on and the 2435 is with in range. Each device in the network must have a valid IP address. The IP addresses set on the terminal must match the addresses configured on the DCS 30X or host. For help, see “Using RF Communications on the 2435” on page 54.
You are having problems with your 802.11b network coverage.
Make sure that the Medium Density Distribution command on your access point is not enabled. When the Medium Density Distribution command is enabled, the access point distributes values for these RF coverage parameters to your terminal: AP Density, Medium Reservation, and Microwave Robustness. Changes made by your access point are not reflected in the terminal menu system.
The 2435 is connected to the DCS 30X or host computer, and you move to a new site to collect data. The Network Connect status icon was on and now begins to blink or turns off.
You may have gone out of range of an access point. Try moving closer to an access point or to a different location to re-establish communications. Once you are in range again, the Network Connect status icon will appear and remain on. Any data you collected while you were out of range will be transmitted over the network.
When you turn on the terminal after it was suspended for 10-15 minutes or longer, the terminal can no longer send or receive messages over the network.
The host may have deactivated or lost your current terminal emulation session. In a TCP/IP direct connect network, you need to turn off the “Keep Alive” message (if possible) from the host so that the TCP session is maintained while a terminal is suspended.
The Network Connect status icon is on, but you cannot establish a terminal emulation session with the host computer.
There may be a problem with the host computer, a problem with the connection between the DCS 30X and the host computer, or a problem with the connection between the access point and the host (TCP/IP). Check with your network administrator to make sure the host is running and allowing users to login to the system.
The Network Connect status icon blinks on the terminal screen and you see this message:
The 2435 is connected to the access point but is trying to establish communications with the DCS 30X and the host computer. Make sure the terminal is correctly configured for your network. In a UDP Plus or WTP network, make sure the DCS 30X is configured and data collection is started. In a TCP/IP network, make sure the host computer is configured and running.
Unable to connect to controller. Error 102. Unable to establish connection to host. Session ended.
If the network is configured correctly, try shutting down and restarting the DCS 30X to establish communications. You can also reset the terminal. For help, see “Resetting the Terminal” on page 81.
74
Trakker Antares 243X Handheld Terminal User’s Manual
Page 89
nugget
39 Chapter 4 - Troubleshooting and Maintaining the Terminal
Problems While Running Applications If you are running applications on the terminal and have trouble, check these possible problems and solutions. Problems While Running Applications Problem There is not enough memory to load a program.
Possible Solution You need to free conventional memory by removing files or applications from drive C. For help, see “Delete File” in Chapter 5 of the 2400 Family system manual.
You see this error message when trying to load a program:
You need to free conventional memory by removing files or applications from drive C. For help, see “Delete File” in Chapter 5 of the 2400 Family system manual.
ERROR LOADING MODULE LIBRARY NAME: <libraryname> FILE NAME: <filename> where libraryname and filename are the library and files names of the program. You see one of these error messages while running a PSK or EZBuilder application: SCREEN ERROR: 30 Code: 9 Hit any key To exit!
You must set the RAM Drive Size configuration command. For help, see “RAM Drive Size” in Chapter 6, “Configuration Command Reference,” in the 2400 Family system manual.
SCREEN ERROR: 31 Code: 3 Hit any key To exit! You try to run a DOS application in the TRAKKER Antares 2400 Menu System and see this message: Not a valid application.
You tried to run a DOS .EXE application from the TRAKKER Antares 2400 Menu System. You can only run .BIN applications in the menu system. To run a DOS .EXE application, enter the filename at the DOS prompt. For help, see “Running DOS Applications and Using ROM-DOS Commands” in Appendix D of the 2400 Family system manual.
A DOS command does not work.
For a list of commands, see “Using ROM-DOS Commands” in Appendix D of the 2400 Family system manual.
The terminal does not boot after you modified the CONFIG.SYS file to configure a ROM-DOS RAM drive.
Correct the error in CONFIG.SYS and use the DOS software tools to recreate drive A with the corrected CONFIG.SYS file.
Trakker Antares 243X Handheld Terminal User’s Manual
75
Page 90
Chapter 4 - Troubleshooting and Maintaining the Terminal nugget
39
Problems Transmitting Data Through the Serial Port If you are having problems sending or receiving data through the serial port on the terminal, check these possible problems: • Make sure the terminal is connected to the PC, host computer, or serial device through COM1. For help, see “Connecting to a Serial Device or Network” on page 28. • Make sure you are using the appropriate cable to connect the terminal to the PC, host, or serial device. • Make sure the terminal’s serial port parameters are configured to match the serial port configuration on the host computer or serial device. For help, see “Using Serial Communications on the Terminal” on page 51.
Problems Transmitting Data Through the DCS 30X If you have a problem while running the application on the terminal in a UDP Plus or WTP network, check these possible communications problems. Problems Transmitting Data Through the DCS 30X Problem Transaction Buffer Full.
Possible Solution The buffer holding transactions to be sent to the DCS 30X is full. Stop collecting data with this terminal. Make sure the terminal is communicating with the DCS 30X and let the terminal send all the transactions in the buffer before you continue collecting data.
Sending Buffer Transactions.
This is an information message to tell you that buffered transactions are now being sent to the DCS 30X. You can begin collecting data again once the message clears.
Transaction Aborted.
The transaction just sent to the DCS 30X was not received. Try sending the transaction again.
Transmit Error XX, press Enter.
There is an error transmitting data to the DCS 30X. XX represents the status code error. Note the error code listed in the message and contact your local Intermec service representative for help. Press the Enter key to continue.
Receive Error XX, press Enter.
There is an error receiving data from the DCS 30X. XX represents the status code error. Note the error code listed in the message and contact your local Intermec service representative for help. Press the Enter key to continue.
Shutting down.
The DCS 30X is shutting down. You may continue collecting data and buffer the transactions in the terminal until the DCS 30X starts again or stop collecting data with the terminal.
Controller Shutdown.
The DCS 30X has shut down. You may continue collecting data and buffer the transactions in the terminal until the DCS 30X starts again or stop collecting data with the terminal.
76
Trakker Antares 243X Handheld Terminal User’s Manual
Page 91
nugget
39 Chapter 4 - Troubleshooting and Maintaining the Terminal
Problems Scanning Bar Code Labels If you cannot scan bar code labels or you are having problems with the scanner, check these possible problems. Problems Scanning Bar Code Labels Problem You cannot see a red beam of light from the scanner when you press the scan button and aim the scanner at a bar code label.
Possible Solution You may be too far away from the bar code label. Try moving closer to the bar code label and scan it again. You may be scanning the bar code label “straight on.” Try changing the scanning angle. Do not look directly into the window area or at a reflection of the laser beam while the laser is scanning. Long-term exposure to the laser beam can damage your vision. Avertissement: Ne regardez pas directement la réflexion d’un rayon laser ou dans la fenêtre du laser lorsque celui-ci est en opération. Si vous regardez trop longtemps un rayon laser, cela peut endommager votre vue.
The terminal is turned off.
Make sure the terminal is turned on. Press f or ' to turn on the terminal.
The scanner will not read the bar code label.
Ensure the scanner beam covers the entire bar code label in one pass. Make sure the bar code symbology you are scanning is enabled. Use the TRAKKER Antares 2400 Menu System to check the symbologies. On the Symbologies Menu, each symbology that is enabled has an asterisk (*) next to the name of the symbology. If your bar code symbology is disabled, enable it and then try scanning the bar code label again. Make sure that the application you are running on the terminal is expecting input from a bar code. You may need to type this information instead of scanning it. If you are using the advanced long range scanner, you may not be able to scan the bar code labels in this manual. However, you can still send commands through the serial port or network. For help, see Chapter 2, “Configuring the Terminals,” in the 2400 Family system manual. The angle at which you are scanning the bar code label may not be working well, or you may be scanning the label “straight on.” Try scanning the bar code label again, but vary the scanning angle. The bar code label print quality may be poor. To check the quality of the bar code label, try scanning a bar code label that you know scans. Compare the two bar code labels to see if the bar code quality is too low. You may need to replace the label that you cannot scan.
Trakker Antares 243X Handheld Terminal User’s Manual
77
Page 92
Chapter 4 - Troubleshooting and Maintaining the Terminal nugget
39
Problems Scanning Bar Code Labels (continued) Problem The integrated scanner does not read the bar code labels quickly, or the scanning beam seems to be faint or obscured.
Possible Solution The scanner window may be dirty. Clean the window with a solution of mild soap and water. Wipe dry. Do not allow abrasive material to touch the window.
You have an input device attached to the terminal and it cannot read any bar code labels.
You may not be using an input device that is supported by the 243X. Make sure you are using one of the supported input devices listed in Appendix A, “Specifications.” Your 243X may not be configured for the input device connected to it. You must configure the Scanner Selection command and select the input device that is connected to the terminal. For help, see “Scanner Selection” in Chapter 6, “Configuration Command Reference,” in the 2400 Family system manual.
The input device connected to the terminal does not appear to work well or read bar code labels very quickly.
Make sure that the Scanner Selection command is set to the specific tethered scanner you have attached. For help, see “Scanner Selection” in Chapter 6, “Configuration Command Reference,” in the 2400 Family system manual. Check the bar code symbologies you have enabled on the terminal. Enable only the symbologies that you are using.
You try to scan a bar code label with an input device and the integrated scanner on the terminal turns on.
Your 243X may not be configured for the input device connected to it. You must configure the Scanner Selection command and select the input device that is connected to the terminal. If this command is not defined for the appropriate input device, the scanner trigger on the input device may activate the integrated scanner on the terminal. For help, see “Scanner Selection” in Chapter 6, “Configuration Command Reference,” in the 2400 Family system manual.
You are scanning bar code labels, and the terminal appears to be operating slowly.
The terminal may be configured for the 5x6, 6x8, or 12x16 font type. These font type values may cause the 243X to scroll, and therefore operate, more slowly when it displays bar code values on the screen. Change the font type to a value other than 5x6, 6x8, or 12x16. For help, see “Display Font Type” or “Display Spacing” in Chapter 6 of the 2400 Family system manual. If the terminal continues to operate slowly, contact your local Intermec service representative for help.
When you release the Scan Button, the Good Read LED does not turn off.
The Good Read LED remains on if you configure the terminal to use edge triggering. If you configure the terminal for level triggering and the Good Read LED remains on, there may be a problem with the LED. Press the Scan Button again without scanning a bar code label. If the LED is still on, contact your local Intermec service representative.
Booting the Terminal You seldom need to boot or reset the terminal. When you boot the terminal, it runs through power-on self test (POST) to test each major subsystem. The terminal uses the configuration currently saved in flash memory. After the terminal is finished booting, your application appears on the screen.
78
Trakker Antares 243X Handheld Terminal User’s Manual
Page 93
nugget
39 Chapter 4 - Troubleshooting and Maintaining the Terminal
You can boot the terminal using these two methods: • Configure the f key or the ' key to boot the terminal when you turn on the terminal. • Use the Boot Menu.
Booting the Terminal on Resume When you press f or ' to turn off the terminal, it turns off and goes into Suspend mode. When you press f or ' to turn on the terminal, it resumes or boots depending on the terminal configuration. There are two ways to configure the f key or the ' key using the Resume Execution configuration command:
Resume Execution Not Allowed
Configures the terminal to boot and restart your application each time you press f or ' to turn on the terminal. Use this option if you want to restart your application every time you turn on the terminal.
Resume Execution Allowed
Configures the terminal to resume exactly where it was when you turned off the terminal. Use this option to resume working each time you turn on the terminal. You can configure the Resume Execution command by using the TRAKKER Antares 2400 Menu System or by scanning these bar code labels. For help, see Chapter 2, “Configuring the Terminal,” or see “Resume Execution” in Chapter 6 of the 2400 Family system manual. Resume Execution Not Allowed
Resume Execution Allowed
*$+ER0*
*$+ER1*
*$+ER0*
*$+ER1*
Using the Boot Menu To access the Boot menu, you can: • upgrade the firmware. For help, see “Upgrading the Firmware” in Chapter 2 of the 2400 Family system manual. • reset the terminal. For help, see “Resetting the Terminal” on page 81. • remove the main battery and wait longer than 15 minutes to install a charged main battery. This procedure also performs a destructive reset, which can have unpredictable results.
Trakker Antares 243X Handheld Terminal User’s Manual
79
Page 94
Chapter 4 - Troubleshooting and Maintaining the Terminal nugget
39
The Boot Menu contains these commands: Boot Menu Commands Command Boot System
Description Press 1 to boot the terminal. Once the terminal is finished booting, your application appears on the screen.
Run Loader
Press 2 to load the terminal firmware. To upgrade or load the firmware, use the Firmware Upgrade option in the TRAKKER Antares 2400 Menu System. For help, see Chapter 2, “Configuring the Terminals,” in the 2400 Family system manual.
Power Down
Press 3 to turn off the terminal. When you turn on the terminal, the Boot Menu screen appears again if POST passes.
Troubleshooting a Locked Up Application If the terminal or application is locked up and the terminal will not respond to any key sequences, try the following to reset the terminal and perform a warm boot. To perform a warm boot 1 Press f or ' to turn off the terminal, and then press f or ' to turn on the terminal. 2 Use the TRAKKER Antares 2400 Menu System to reboot the terminal. a Scan this bar code to enter the TRAKKER Antares 2400 Menu
System: TRAKKER Antares 2400 Menu System
*..-.* *..-.* b Choose System Menu, and then choose Upgrade Firmware. c Choose OK, choose YES, and then press the Esc key. The Boot
Menu appears. d Press 1 to boot the terminal.
3 Scan the Reset Firmware label to restart the firmware and application. Reset Firmware
*-.*
*-.*
If the terminal or application still will not respond, reset the terminal. For help, continue with the next section.
80
Trakker Antares 243X Handheld Terminal User’s Manual
Page 95
nugget
39 Chapter 4 - Troubleshooting and Maintaining the Terminal
Resetting the Terminal If you performed the steps in “Troubleshooting a Locked Up Application” and the terminal or application is locked up and the terminal will not respond to the Reset Firmware command, follow the steps in this section to reset the terminal. To reset the terminal • Scan the Boot Terminal label to reboot the terminal. Boot Terminal
*-.1*
*-.1*
If the terminal will not scan, you can cold boot the terminal and perform a destructive reset. A destructive reset can have unpredictable results. To perform a cold boot 1 If possible, press f or ' to turn off the terminal. 2 Press and hold the f key or the ' key for approximately 12 seconds. The Good Read LED blinks once and the terminal turns off. 3 Press f or ' to turn on the terminal. The Boot Menu appears. 4 Press 1 to boot the terminal. Once the terminal has finished booting, your application appears. 5 Set the time and date. For help using the TRAKKER Antares 2400 Menu System, see “Configuring the Terminal With the Menu System” on page 33.
Cleaning the Scanner Window and Terminal Screen The terminals are built for use in an industrial working environment. You may need to perform these minor maintenance tasks to keep the terminal in good working order: • Clean the scanner window. • Clean the terminal screen. Clean the scanner window and terminal screen as often as needed for the environment in which you are using the terminal. To clean the scanner window and terminal screen 1 Press f or ' to turn off the terminal. 2 Use a solution of mild soap and water.
Trakker Antares 243X Handheld Terminal User’s Manual
81
Page 96
Chapter 4 - Troubleshooting and Maintaining the Terminal nugget
39
3 Dip a clean towel or rag in the soap and water solution and wring out the excess solution. Wipe off the scanner window and terminal screen. Do not allow any abrasive material to touch these surfaces. 4 Wipe dry. There are no user-serviceable parts inside the terminal. Opening the unit will void the warranty and may cause damage to the internal components. Attention: La terminal ne contient pas de pièces révisibles par l’utilisateur. Le fait d’ouvrir l’unité annule la garantie et peut endommager les pièces internes.
82
Trakker Antares 243X Handheld Terminal User’s Manual