The text of a manual · part 11 of 12
Trakker Antares 243X Handheld Terminal User's Manual: Appendix A - Specifications
Pages 97 to 104 of 114, from Trakker Antares 243X Handheld Terminal User's Manual
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2435
Page 97
A
Specifications
This appendix contains these terminal’s physical and environmental specifications: • Terminal dimensions • Power specifications • Electrical specifications • Temperature and environmental specifications • Screen • Accessories • Keypad options • Application options • Connectivity options • Memory • 802.11b radio specifications • OpenAir radio specifications • Wired data communications • Bar code symbologies • Input devices • Pin assignments
Trakker Antares 243X Handheld Terminal User’s Manual
83
Page 98
Appendix A - Specifications nugget
39
Physical and Environmental Specifications Terminal Dimensions Length:
25.4 cm (10 in)
Height:
4.6 cm (1.8 in) at grip
Width:
10.2 cm (4 in) at screen
Weight:
708.7 g (25 oz) with battery
Power Specifications Operating:
Rechargeable 2200 mAh battery pack
Backup:
Rechargeable capacitor
Electrical Specifications Models:
2430, 2435
Electrical rating:
x 7,4 to 12V; 1,15 A
Temperature and Environmental Specifications Operating the terminal Standard 243X:
-20°C to 50°C
-4°F to 122°F
Cold-temperature 243X:
-30°C to 50°C
-22°F to 122°F
Storing the terminal:
-20°C to 50°C
-4°F to 122°F
Charging the terminal:
0°C to 40°C
32°F to 104°F
Relative humidity:
0 to 90% non-condensing
Environmental rating:
IP54
Note: The cold-temperature option supports excursions into a -30°C (-22°F) environment for limited durations. Using this option severely affects battery life. For more information, see “Using the Terminal’s Battery Pack” on page 7.
Screen • CGA-compatible, backlit LCD • Configurable up to 21 lines by 32 columns Note: If status icons are enabled, the screen is configurable up to 21 lines by 31 characters instead of 21 lines by 32 characters. For more information about the status icons, see “Learning About the Status Icons” on page 20.
84
Trakker Antares 243X Handheld Terminal User’s Manual
Page 99
nugget
39 Appendix A - Specifications
Accessories You can use these accessories (sold and ordered separately) with the 243X: • Lithium-ion battery pack (P/N 073152) • Z2400 battery charger (P/N Z2400A) • Vehicle dock • Standard (P/N 071805) • Powered (P/N 071695) • Handle (P/N 067802) • Holster (P/N 072366) • AC power supply (P/N 065236) • AC power supply adapter cable (ships with the 243X) (P/N 071776) • Serial adapter cable (P/N 216-807-001) • Cloning cable (P/N 216-909-001)
Keypad Options • (57-key) Alphanumeric keypad, available with programmable, international, 3270 TE, 5250 TE, or VT/ANSI TE overlays • (39-key) Alphanumeric keypad, available with programmable, international, 3270 TE, 5250 TE, or VT/ANSI TE overlays • (48-key) Large alphanumeric keypad, available with programmable, international, 3270 TE, 5250 TE, or VT/ANSI TE overlays
Application Options • Programmable terminal • (2435) Data Collection Browser (dcBrowser) • (2435) TE 2000 terminal emulation
Connectivity Options • RS-232 • (2435) TCP/IP with DHCP and TFTP support • (2435) TCP/IP with DHCP and TFTP support and 802.1x TTLS or LEAP security • (2435) UDP Plus or WTP with 802.1x TTLS or LEAP security • (2435) UDP Plus with DHCP (Controller) support • (2435) WTP
Trakker Antares 243X Handheld Terminal User’s Manual
85
Page 100
Appendix A - Specifications nugget
39
Memory • 4MB flash memory, configured as a 2MB flash drive, pre-loaded with double-byte fonts, or used for 802.1x TTLS security • 1MB battery-backed RAM, 512K available for user • (2410 option) 2MB or 4MB extended storage drive
802.11b Radio Specifications Radio type
Direct sequence, spread spectrum
Channels
11 (North America), 13 (Europe), 4 (France), 1 (Japan)
Data rate
11 Mbps (High), 5.5 Mbps (Medium), 2 Mbps (Standard), 1 Mbps (Low) with automatic fallback for increased range
Range (11 Mbps)
160 m (525 ft) open environment 50 m (165 ft) semi-open environment 24 m (80 ft) closed environment
Frequency band
2.4 to 2.5 GHz world-wide
OpenAir Radio Specifications Radio type
Frequency hopping, spread spectrum
Channels
15
Data rate
1.6 Mbps, 0.8 Mbps fallback
Range
Up to 150 m (500 ft) indoors Up to 300 m (1,000 ft) outdoors
Frequency band
2.4 to 2.5 GHz worldwide
Wired Data Communications • RS-232C serial port (COM1) • XMODEM, XMODEM1K, or YMODEM protocol for data transfer • Protocols: Binary, Configurable Serial Protocol, Master Polling, and Polling Mode D
Bar Code Symbologies • Codabar
• Interleaved 2 of 5
• Code 11
• MSI
• Code 2 of 5
• PDF 417
• Code 39
• Plessey
• Code 93
• UPC/EAN
• Code 128 Note: The Code 11 symbology is not supported on 243X terminals with the integrated linear imager. Additionally, Code 11 is only supported on 243X terminals configured for non-decoded scanning. The PDF 417 symbology is only supported on 243X terminals configured for decoded
86
Trakker Antares 243X Handheld Terminal User’s Manual
Page 101
nugget
39 Appendix A - Specifications scanning. For more information, see “Code 11” or “PDF 417” in Chapter 6 of the Trakker Antares 2400 Family System Manual (P/N 071389).
Input Devices Unless you ordered a terminal with the no scanner option, the 243X comes with an integrated scanner for scanning bar code labels. Additionally, you can attach these Intermec-recommended input devices to the 243X: • Intermec 1400 linear imager • Intermec 1551E laser scanners • Intermec 1553E laser scanners • Intermec 1800 scanners After you determine which input device to use, you need to connect it to the 243X using an interface cable and configure the Scanner Selection command on the 243X. The appropriate interface cable and Scanner Selection command value for each input device is listed in the next sections. For more information about the Scanner Selection command, see “Scanner Selection” in Chapter 6 of the 2400 Family system manual. Intermec is frequently testing and developing new input devices. For an updated list of Intermec-approved input devices for the 243X, see your Intermec sales representative.
Input Devices for the Standard Connector Module Use the next table to determine which interface cable and Scanner Selection command value to use for each input device. To learn more about the standard connector module, see “Learning About the Connector Modules” on page 26. Input Devices for the Standard Connector Module Input Device 1400 linear imager
Input Device Part Number 3-650019-00
Interface Cable Part Number 3-606030-00
Scanner Selection Command All compatible
1551E
1551E0600
3-606030-00
All compatible
1553E XLR
1553E0603
3-606030-00
All compatible
You can actively switch between the input device and the integrated scanner. If you only want to enable the integrated scanner, set the Scanner Selection command to the value for the specific integrated scanner installed on the 243X. For example, if you have an integrated long range scanner, set the Scanner Selection command to “Intg. L/R.”
Trakker Antares 243X Handheld Terminal User’s Manual
87
Page 102
Appendix A - Specifications nugget
39
Input Devices for the Serial Connector Module Use the next table to determine which interface cable and Scanner Selection command value to use for each input device. To learn more about the serial connector module, see “Learning About the Connector Modules” on page 26. Input Devices for the Serial Connector Module Input Device 1400 linear imager
Input Device Part Number 3-650019-00
Interface Cable Part Number 3-606032-03
Scanner Selection Command (See Note) Integrated
1400 linear imager
3-650019-00
3-606032-03
Intermec 1553
1551E PDF 417
1551E0808
3-606032-03
Integrated
1551E PDF 417
1551E0808
3-606032-03
Intermec 1551E
1551E
1551E0600
3-606032-03
Integrated
1551E
1551E0600
3-606032-03
Intermec 1553
1553E XLR
1553E0603
3-606032-03
Integrated
1553E XLR
1553E0603
3-606032-03
Intermec 1553
1800SR
0-3600394-00
0-364032-00
Serial non-PDF 417
1800VT PDF
0-369039-00
0-364032-00
Serial PDF 417
Note: The “Integrated” value for the Scanner Selection command refers to the specific integrated scanner installed on the terminal. For example, if you have an integrated long range scanner, the Scanner Selection command should be set to “Intg. L/R.” The Intermec 1551E value indicates PDF 417 capability, and the Intermec 1553 value indicates nonPDF 417 capability.
Pin Assignments You can use the pin assignments to make your own serial cables or troubleshoot problems.
Pin Assignments for COM1 Charge in (12 VDC)-6
5-CTS
RTS-4
3-GND
RXD-2
1-TXD 243XU036.eps
COM1: This illustration shows the type of connector and the pin assignments for COM1.
88
Trakker Antares 243X Handheld Terminal User’s Manual
Page 103
nugget
39 Appendix A - Specifications
Pin Assignments for the Input Device Connectors The following illustrations show the type of connector and pin assignments for the input device connectors on the standard and serial connector modules. 1 Not used Not used-6 2-RXD RTS-7 CTS-8
3-TXD 4 Not used
+5 V-9 5-GND 243XU040.eps
Serial Connector Module (Decoded Scanner Connector)
1-SSOS Enable-6 2-S Data GND-7 GND-8
3-Scan LED 4-Spare1
+5 V-9 5-Trigger 243XU042.eps
Standard Connector Module (Non-Decoded Scanner Connector)
Trakker Antares 243X Handheld Terminal User’s Manual
89
Page 104
Appendix A - Specifications
90 nugget
39
Trakker Antares 243X Handheld Terminal User’s Manual