Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 8 of 12

Trakker Antares 243X Handheld Terminal User's Manual: Chapter 3 - Operating the Terminal in a Network, pages 68 to 76

Pages 68 to 76 of 114, from Trakker Antares 243X Handheld Terminal User's Manual

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2435

Page 68

Chapter 3 - Operating the Terminal in a Network

Polling Mode D Protocol Polling Mode D protocol requires the host computer to ask the terminal for data it may have (polling) and to request to send data to the terminal (selecting). This protocol uses an RS-232 interface and implements the user interface through reader commands. Polling Mode D also supports XON/XOFF and CTS/RTS flow control. You can configure the following serial port parameters: • Baud rate • Flow control

Using RF Communications on the 2435 Make sure all components with antennas are at least 30 cm (1 ft) apart when power is applied. Failure to comply could result in equipment damage. Attention: Assurez-vous que la distance entre tous les éléments avec antennes soit d'au moins 30 centimètres (un pied) avant de faire la connexion avec l'alimentation électrique, faute de quoi vous risquez d'endommager votre installation. The 2435 has an internal antenna to transfer data using RF communications. Before you can use RF communications, you must perform these steps: 1 Plan and prepare your network. For help, see the next section, “Planning the Network Connection.” 2 (UDP Plus or WTP network only) Configure the DCS 30X. For help, see “Configuring the DCS 30X” on page 55. 3 Configure the access points and radios. For help, see “Configuring the Access Points” on page 56. 4 Configure the network parameters on each terminal in the network. For help, see “Configuring the 2435 Network Parameters” on page 57. 5 (802.1x security) Configure the 802.1x TTLS or LEAP security parameters on each terminal in the network. For help, see “Configuring the 802.1x Security Parameters” on page 58. The set of network parameters you need to configure depends on whether you install the terminal on the same subnetwork as the DCS 30X (UDP Plus or WTP) or host (TCP/IP) or on a different subnetwork. For help determining which network parameters you must configure, see “Configuring the 2435 Network Parameters” on page 57.

54

Trakker Antares 243X Handheld Terminal User’s Manual

Page 69

Chapter 3 - Operating the Terminal in a Network

When you begin using the 2435, you need to understand how to use the LEDs to monitor the RF communications. For help, see “Monitoring Network Communications” on page 62.

Planning the Network Connection To use the 2435 in the RF network, you need these minimum requirements: • DCS 30X (UDP Plus or WTP network) • Access point When you first consider purchasing a wireless data collection system, an Intermec representative works with you to perform a site survey at your facility. The site survey analyzes the range of radio frequency devices in your facility and determines the placement of the access points. The site survey ensures that the coverage of each access point overlaps to provide uninterrupted wireless access at any location within the building. This manual assumes that a site survey is complete and the access points are installed in your facility. You need to work with your network administrator to plan and assign the IP address for each device in the RF network. You need to assign and set the IP address for each access point (RF) and each 2435. If you are using a UDP Plus or WTP network, you need to also assign an IP address to the DCS 30X.

Configuring the DCS 30X The DCS 30X supports and manages communications with other devices in the UDP Plus or WTP network. When you install and configure the DCS 30X, you identify the host computers and 2435 terminals in your network. In a UDP Plus network, the terminals communicate using a reliable RF protocol (UDP Plus) through the access points to the DCS 30X. The DCS 30X translates UDP Plus to a reliable wired protocol (TCP/IP) and sends the data to the host. For more information, see the user’s manual for the DCS 30X. In a WTP network, the terminals communicate to the DCS 30X through the access points connected to the Ethernet network. For more information, see the appropriate TE 2000 manual. Note: You can use a 2435 running TCP/IP and the DCS 30X in a passthrough network. You establish a direct TCP/IP socket connection from the 2435 to the host through the server.

Trakker Antares 243X Handheld Terminal User’s Manual

55

Page 70

Chapter 3 - Operating the Terminal in a Network

To allow the 2435 to communicate with the DCS 30X, you need to perform these tasks on the server: • Define the host communications parameters, which includes the physical connection (network adapter cards) to the host. • Define the host environment parameters, which includes configuring for terminal emulation or client/server applications. • Configure the UDP Plus or WTP network. • Assign an IP address to each 2435. If you are using a DHCP (Dynamic Host Configuration Protocol) server in a TCP/IP network, you can leave the default terminal IP address as 0.0.0.0 to enable the 2435 as a DHCP client. For help, see “DHCP (Terminal)” in Chapter 6 of the 2400 Family system manual. • Enable all 2435 terminals. To use dcBrowser, you do not define the host environment parameters. You must: • create an HTML application. • configure the dcBrowser gateway.

Configuring the Access Points Access points act as bridges to provide communications between the wired network and the RF (UDP Plus, WTP, or TCP/IP) networks. After you configure the network, you can collect data anywhere within range of the access points in the wireless network. When you move out of range of one access point, the 2435 automatically searches for other access points to continue the network connection. If you are out of range of all access points in the network, the data is stored in the terminal’s radio buffer. The Network Connect status icon turns off. You can continue to collect data until the radio buffer is full. When the buffer is full, the application displays a communication timeout status. When you move back into range and network communications are reestablished, the data in the radio buffer is transmitted to the access point and you can once again transmit data. In a TCP/IP direct connect network with a terminal running a terminal emulation application, the application may disconnect from the host if you remain out of communications range too long or if the host sends “Keep Alive” messages while the terminal is in Suspend mode. You may need to restart the application and log back into the host to re-establish a terminal emulation session. In a UDP Plus or WTP network, the session is maintained any time the terminal is out of range or in Suspend mode. To communicate through the network, all RF terminals and access points must contain the same type of radio, either a WLI Forum OpenAir or an IEEE 802.11b radio. Depending on the radio in the terminal, you must

56

Trakker Antares 243X Handheld Terminal User’s Manual

Page 71

Chapter 3 - Operating the Terminal in a Network set certain parameters to the same configuration on both the terminal and the access points.

OpenAir Radio To use OpenAir radios in your network, you need to configure: • Domain. On the access points, the Domain parameter is called the LAN ID (Domain) parameter. • Security Identification (ID). The Network Activate command must be configured to 2.4 GHz RF network before you can save any changes to the security ID parameter. These parameters must be set to the same values on the terminals and the access points. Each access point is configured with a different channel/subchannel combination.

802.11b Radio To use 802.11b radios in your network, you need to configure: • Network Name. On the access points, the Network Name parameter is called the SSID (Network Name) parameter. This parameter is casesensitive. On the terminal, you can also set the Network Name parameter to “ANY” or leave the field blank, allowing the terminal to communicate with any access point that has the same radio and is within range. However, Intermec recommends that you define a unique network name. • WEP Encryption. If you are using 802.1x TTLS or LEAP security, you do not configure WEP Encryption. • (802.1x TTLS or LEAP security only) User Name and Password. For more information about configuring the terminal for 802.1x security, see “Configuring the 802.1x Security Parameters” on page 58. The Network Name and WEP Encryption parameters must be set to the same value on the terminals and the access points.

Configuring the 2435 Network Parameters When you install the 2435 in a network, you need to configure the network parameters that control how the terminal communicates in the network. The set of network parameters you need to configure depends on whether you install the terminal on the same subnetwork as the DCS 30X or host (TCP/IP) or on a different subnetwork. You need to configure: • Network Activate. If you are operating the 2435 in a WTP network, you only need to configure the Network Activate parameter. Trakker Antares 243X Handheld Terminal User’s Manual

57

Page 72

Chapter 3 - Operating the Terminal in a Network

• (UDP Plus) Controller IP Address. • (TCP/IP) Host IP Address. • Terminal IP Address (Non-DHCP environment only). • Network Port. • Default Router (DCS 30X or host on different subnetwork). • Subnet Mask (DCS 30X or host on different subnetwork). For help understanding these parameters and their syntax, see Chapter 6, “Configuration Command Reference,” in the 2400 Family system manual. For more information about network connectivity and protocols, see “About Network Connectivity and Protocols” in Chapter 1 of the 2400 Family system manual.

Configuring the 802.1x Security Parameters Trakker Antares terminals with the 802.1x security option can operate in a protected network that provides secure data transmission. Authentication and authorization is provided using one of these Extensible Authentication Protocol (EAP) types: • Tunneled Transport Layer Security (TTLS) is a standards-based authentication type with multiple vendor support. • Lightweight Extensible Access Protocol (LEAP) is Cisco’s proprietary authentication type. This section describes how to configure both 802.1x TTLS and LEAP security. It also describes how the BASEDATE.TXT file is used.

Learning About BASEDATE.TXT During authentication, TTLS security uses the date that is set on your Trakker Antares terminal to make sure that the terminal falls within the valid date range of the certificate received from the authentication server. Your terminal uses the BASEDATE.TXT file to set the current date. BASEDATE.TXT is originally set to the release date of the most recent version of firmware, however, it is now updated in these situations: • When you download the latest version of firmware to your PC, BASEDATE.TXT is updated to reflect the current time and date on your PC. • If BASEDATE.TXT is not loaded on your terminal, it will be created: • when you download the latest version of firmware to your PC. It will reflect the current time and date on your PC. • when you set the current time and date on your terminal. • If BASEDATE.TXT is loaded on your terminal, the BASEDATE.TXT text is updated when you set the current time and date on your terminal. 58

Trakker Antares 243X Handheld Terminal User’s Manual

Page 73

Chapter 3 - Operating the Terminal in a Network

Configuring 802.1x TTLS Security To use 802.1x TTLS security, you need: • a PC with the Funk Odyssey server software version 1.1 or later. This PC must also be configured with the current date and time, because the server uses these values when it authenticates the terminal. Note: You can also use a MobileLAN access point with software release 1.80 or later as an authentication server. For help, see the MobileLAN access System Manual (P/N 067150). • an Intermec MobileLAN access point with an 802.11b radio and software release 1.80 or later that serves as an authenticator. The authenticator knows the IP address and secret key of the authentication server and translates EAP-TTLS frames to RADIUS frames and vice versa. • a Trakker Antares terminal. Your terminal must have an 802.11b radio, the 802.1x security option, and firmware version 7.14 or later. Note: The CACERT.PEM file on the terminal’s C drive is used for 802.1x TTLS security. Do not delete this file from your terminal. If this file is deleted, you will need to download the latest version of firmware to your terminal. For help, see “Upgrading the Firmware” in Chapter 2 of the 2400 Family system manual. To enable 802.1x TTLS security on the terminal 1 Make sure that: • your Funk Odyssey authentication server and MobileLAN access point are properly configured. For help, see the documentation for your authentication server and MobileLAN access point. • the PC that the authentication server is loaded on is configured with the current date and time. • your terminal is configured with the primary network, advanced network, and radio parameters. 2 Set the User Name and Password parameters. a Scan this bar code label to access the TRAKKER Antares 2400 Menu

System. TRAKKER Antares 2400 Menu System

*..-.* *..-.*

The Main Menu appears. b Choose Configuration Menu, Communications Menu, and then

Radio.

Trakker Antares 243X Handheld Terminal User’s Manual

59

Page 74

Chapter 3 - Operating the Terminal in a Network c Scroll to the 802.1x TTLS screen and set the User Name and

Password parameters. If you just want to make sure that your terminal can be authenticated, you can use the default values of “anonymous” and “anonymous.” However, Intermec recommends that you set your permanent user name and password to unique values. 3 Exit the menu system and save all changes. 4 Turn the terminal off and then on again. If you have an application loaded on your terminal, an application screen appears. If you do not have an application loaded on your terminal, a cursor appears in the top left corner of the screen. An AUTHENTICATING message appears on the terminal screen. Note: The terminal takes up to 60 seconds to authenticate; however, this process may take longer if there is interference in RF communications. When the terminal is authenticated, it emits a low beep and then a high beep. The application that was running on the terminal, if any, resumes. If authentication fails, the terminal emits a high beep and then a low beep. The terminal will wait 60 seconds and restart the authentication process. For help, see “Problems While Configuring 802.1x Security” on page 70. Once you have successfully authenticated your terminal, you need to configure a unique user name, password, and at least one server certificate common name. For help, see Chapter 6, “Configuration Command Reference,” in the 2400 Family system manual.

Configuring 802.1x LEAP Security To use LEAP security on your terminal, you need: • an authentication server that supports LEAP. • a Cisco access point. • a Trakker Antares terminal. Your terminal must have an 802.11b radio, the LEAP security option, and firmware version 7.15 or later. Note: Unlike TTLS security, LEAP security only requires the standard 2MB of memory on the terminal. It does not require the additional 4MB memory option.

60

Trakker Antares 243X Handheld Terminal User’s Manual

Page 75

Chapter 3 - Operating the Terminal in a Network

To enable 802.1x LEAP security on the terminal 1 Make sure that: • your authentication server is properly configured. For help, see the documentation for your authentication server. • your Cisco access point is properly configured for LEAP security. For help, see the documentation for your Cisco access point. • your terminal is configured with the primary network, advanced network, and radio parameters. 2 Configure your Cisco access point to communicate with your Trakker Antares terminal using LEAP security. a Access the AP Radio Data Encryption screen. For help, see the documentation for your Cisco access point.

Note: The AP Radio Data Encryption screen for your Cisco access point may look different than the one shown here. b Check the Open check box for both Accept Authentication Type and

Require EAP. c Click OK.

Trakker Antares 243X Handheld Terminal User’s Manual

61

Page 76

Chapter 3 - Operating the Terminal in a Network

3 Set the User Name and Password parameters on your Trakker Antares terminal. a Scan this bar code to access the TRAKKER Antares 2400 Menu

System: TRAKKER Antares 2400 Menu System

*..-.* *..-.*

The Main Menu appears. b Choose Configuration Menu, Communications Menu, and then choose Radio. c Use the arrow keys to scroll to the LEAP screen and set the User

Name and Password parameters. If you just want to make sure that your terminal can be authenticated, you can use the default values of “anonymous” and “anonymous.” However, Intermec recommends that you set your permanent user name and password to unique values. For help, see Chapter 6, “Configuration Command Reference,” in the 2400 Family system manual. 4 Exit the menu system and save all changes. 5 When the terminal is authenticated, it emits a low beep and then a high beep. The application that was running on the terminal, if any, resumes. If authentication fails, the terminal emits a high beep and then a low beep. The terminal will wait 60 seconds and restart the authentication process. For help, see “Problems While Configuring 802.1x Security” on page 70.

Monitoring Network Communications After you configure the 2435 in the RF network, you can use the application on the 2435 to collect and transmit data through network communications. If the 2435 is communicating with your host computer, it will connect to your host computer and begin running the application that shipped on the terminal. As you use the 2435 to collect data, the Network Connect icon helps you monitor network communications between the 2435 and other devices in the RF network. To learn how to use the Network Connect icon, see “Learning About the Status Icons” on page 20.

62

Trakker Antares 243X Handheld Terminal User’s Manual