The text of a manual · part 7 of 12
Trakker Antares 243X Handheld Terminal User's Manual: Chapter 3 - Operating the Terminal in a Network, pages 59 to 67
Pages 59 to 67 of 114, from Trakker Antares 243X Handheld Terminal User's Manual
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2435
Page 59
3
Operating the Terminal in a Network
This chapter describes how to install and configure the 243X in a serial or RF network. It also explains how the 243X fits into a particular network and how to use serial or network communications. This chapter covers these topics: • How the terminals fit in your network • Using serial communications on the terminals • Using RF communications on the 2435 • Enabling 802.1x TTLS or LEAP security
Trakker Antares 243X Handheld Terminal User’s Manual
45
Page 60
Chapter 3 - Operating the Terminal in a Network
How the Terminals Fit Into Your Network The 2430 and 2435 are versatile handheld terminals that you can easily add to your network or distributed data collection system. The terminals have a serial port to transmit data to and receive data from a host computer or PC through RS-232 serial communications. Mainframe File server
Terminals Ethernet
PC
243X hardwired to PC
243XU028.eps
243X in a wired network: You can use the 2430 and the 2435 as end devices in your wired network. You can also use the 2435 as an end device in the RF network.
46
Trakker Antares 243X Handheld Terminal User’s Manual
Page 61
Chapter 3 - Operating the Terminal in a Network
TCP/IP Direct Connect Network In a TCP/IP network, the 2435 communicates with a host computer directly using TCP/IP for the RF protocol.
UDP Plus or WTP Network In a UDP Plus or WTP network, the 2435 communicates with a host computer through the DCS 30X. The DCS 30X translates UDP Plus and WTP packets on the RF network into TCP/IP packets on the wired network and vice versa. Host
TCP/IP Direct Connect
UDP Plus or WTP
Ethernet
DCS 30X Access point
2435s
Access point
2435s 243XU026.eps
2435s in a TCP/IP direct connect network, UDP Plus network, or WTP network: In each of these networks, the access point acts as a bridge to allow communications between the wired network and the RF network.
Trakker Antares 243X Handheld Terminal User’s Manual
47
Page 62
Chapter 3 - Operating the Terminal in a Network
Multiple Subnetworks (UDP Plus) In a UDP Plus network, you can install the 2435 terminals, access points, and DCS 30X as shown in the next illustration. All the terminals and access points in this illustration communicate with the DCS 30X at IP address 192.9.175.7. If you are using MobileLAN™access points, a terminal can roam across subnetworks. However, to roam across subnetworks, all terminal IP addresses must belong to the root IP subnet. For more information, see the MobileLAN access System Manual (P/N 067150). 192.9.175.7 DCS 30X
192.9.200.X subnetwork
Router
Access point
Ethernet
Access point
192.9.175.X subnetwork
Access point
2435s 192.9.175.10 192.9.175.11 192.9.175.12 243XU024.eps
2435s 192.9.200.5, 192.9.200.6
2435s in multiple subnetworks (UDP Plus): In this illustration, if you were using MobileLAN access points, the root IP subnet was 192.9.175.X, and all terminals had a terminal IP address of 192.9.175.X, they could roam across subnetworks.
48
Trakker Antares 243X Handheld Terminal User’s Manual
Page 63
Chapter 3 - Operating the Terminal in a Network
Multiple Subnetworks (TCP/IP) In a TCP/IP network, you can install the 2435 terminals and access points as shown in the next illustration. All the terminals and access points in this illustration communicate with the host at IP address 192.9.175.7. If you are using MobileLAN access points, a terminal can roam across subnetworks. However, to roam across subnetworks, all terminal IP addresses must belong to the root IP subnet. For more information, see the MobileLAN access System Manual (P/N 067150). Host
192.9.175.7
192.9.200.X subnetwork
Router
Access point
Ethernet
Access point
192.9.175.X subnetwork
Access point
2435s 192.9.175.10 192.9.175.11 192.9.175.12 243XU022.eps
2435s 192.9.200.5, 192.9.200.6
2435s in multiple subnetworks (TCP/IP): In this illustration, if you were using MobileLAN access points, the root IP subnet was 192.9.175.X, and all terminals had a terminal IP address of 192.9.175.X, they could roam across subnetworks.
Trakker Antares 243X Handheld Terminal User’s Manual
49
Page 64
Chapter 3 - Operating the Terminal in a Network
Communicating Across Subnetworks (UDP Plus) You can install the 2435 terminals and access points in one subnetwork and install the DCS 30X or host in another subnetwork. In this network, you must configure additional network parameters (default router and subnet mask). 192.9.200.5 DCS 30X
192.9.200.X subnetwork
Router
192.9.175.X subnetwork Ethernet
192.9.175.1
Access point
2435s 192.9.175.9 192.9.175.10 192.9.175.11
243XU020.eps
2435s communicating across subnetworks (UDP Plus): In this illustration, the DCS 30X is in a different subnetwork from the terminals.
50
Trakker Antares 243X Handheld Terminal User’s Manual
Page 65
Chapter 3 - Operating the Terminal in a Network
Using Serial Communications on the Terminal The 243X has a serial port to transfer data to and from another device, such as a printer, modem, or PC, using serial communications. Before you can use serial communications, you must perform these steps: 1 Connect the terminal to a serial device or network. For help, see “Connecting to a Serial Device or Network” on page 28. 2 Choose a communications protocol. For help, see the next section, “Choosing a Communications Protocol.” 3 Configure the serial port parameters to allow the terminal to communicate with a host computer or serial device in a wired network. For help configuring the terminal, see Chapter 2, “Configuring the Terminal.” Depending on the protocol you choose in Step 2, you must set some or all of the serial port parameters to have the terminal communicate with a host computer or serial device in a wired network. The values you set for the terminal’s serial port parameters must match the values set for the host’s (or other device’s) serial port parameters.
Choosing a Communications Protocol After you connect the 243X to a host computer or other serial device, you are ready to configure the serial port parameters on the two devices. The terminal uses a communications protocol and XMODEM, XMODEM1K, or YMODEM to handle data communications through the serial ports. You can configure a different communications protocol for each COM port. The terminal’s built-in file operations use XMODEM, XMODEM1K, or YMODEM for file transfer. Communications protocols determine exactly how data is transmitted between the terminal and the connected device. Each protocol has parameters you can set, such as baud rate and parity. Both the terminal and the connected device must use the same protocol and parameter settings to communicate properly. For help with protocols, see the Data Communications Reference Manual (P/N 044737).
Binary Protocol Binary protocol has no protocol. Characters are sent and received without being altered. The Data Link Escape character (DLE) is not inserted before any character, and DLE characters are not stripped out of the incoming data stream. No protocol characters, such as EOM or SOM, are added. Binary mode supports CTS/RTS flow control.
Trakker Antares 243X Handheld Terminal User’s Manual
51
Page 66
Chapter 3 - Operating the Terminal in a Network
You can configure the following serial port parameters: • Baud rate • Data bits • Parity • Stop bits • Flow control
Configurable Protocol Configurable protocol is based on Intermec’s Polling Mode D protocol except that you have the option to change some of the serial port protocol parameters or remove specific events from the protocol, such as poll or handshake. You can configure the following serial port parameters: • Baud rate • Data bits • Parity • Stop bits • Flow control • EOM (End of Message) • Configuration commands via serial port • LRC • SOM (Start of Message) • Handshake (enabled or disabled) • Poll (Polling) (enabled or disabled) • Timeout Delay Configurable protocol uses EOM to determine one of the following serial communications modes.
Character mode When EOM is disabled, the terminal communicates in Character mode processing each character. Character mode supports both XON/XOFF and CTS/RTS flow control.
Frame mode When EOM is enabled, the terminal communicates in Frame mode. When a terminal sends a packet, it adds a protocol character. When a terminal receives a packet, it strips any protocol characters before it sends the information to the terminal application. Frame mode supports both
52
Trakker Antares 243X Handheld Terminal User’s Manual
Page 67
Chapter 3 - Operating the Terminal in a Network
XON/XOFF and CTS/RTS flow control. In Frame mode, you can also configure the following serial port parameters: • Configuration commands via serial port • Handshake • LRC • SOM After you enable Handshake, you can define poll and timeout delay.
Master Polling Protocol Master Polling Mode D protocol requires the terminal to ask the downline serial device for data it may have (polling) and to request to send data to the serial device (selecting). There is no automatic polling, so your application must poll periodically for data. Before each transmit operation, the terminal issues the SEL sequence for the device addressed and sends the data if an acknowledge is received. Before each receive operation, the terminal issues a poll sequence and waits for data or the RES character (no data is available to send). You can configure the following serial port parameter: • Baud rate
Point-to-Point Protocol Point-to-Point protocol is not directly supported on the terminals. However, you can simulate this protocol by setting the protocol to Configurable and configuring these parameters: • Baud rate • Data bits • Parity • Stop bits • Flow control • EOM (Set EOM1 to \x0D, which is <CR>, and set EOM2 to \x0A, which is <LF>) • LRC (Disable) • Handshake (Disable) With this protocol, you cannot configure values for intercharacter delay, turnaround delay, and timeout delay. This protocol supports CTS/RTS flow control only.
Trakker Antares 243X Handheld Terminal User’s Manual
53