Page 307

Chapter 3, INI File Parameter Descriptions

Notes

In Line mode, the Simulator reads a line of characters till it reaches <CR><LF> and returns from im_receive_buffer with that string. In Character mode, the Simulator reads and returns only one character at a time.

sim_optical_key Purpose

Specifies the key sequence that causes the application to accept keyboard input as if it were optical sensor input.

Default

Ctrl-O

Values

A key combination that includes one or more control keys (Ctrl, Shift, or Alt) and a character key (A to Z). Sample key combinations include: CtrlB, Shift-C, and Alt-L.

Function im_get_sensor_all im_get_sensor_input im_receive_input im_receive_field Notes

To simulate optical sensor input: 1 Press a key sequence, for example, Ctrl-O. Although you can press the keys simultaneously or sequentially, you may decide to press them sequentially to avoid conflict with Microsoft® Windows® key code capture. 2 Press 1, 2, 3, or 4 to designate the optical sensor channel. 3 Press one of the status keys, 0 (OFF) or 1 (ON), to end the input. If the input sequence is not entered in the right order, it will be reset to the beginning.

sim_wand_key Purpose

Specifies the key sequence that causes the application to accept subsequent keyboard input as if it were wand input.

Default

Ctrl–G

Values

A key combination that includes one or more control keys (Ctrl, Shift, Alt) and a character key (A to Z).

Function Not applicable Notes

The user presses the key sequence either simultaneously or sequentially, types data that the application accepts as input from a wand, and presses Enter to indicate the end of the input.

Trakker Antares Application Simulator User's Manual

29

Page 308

Chapter 3, INI File Parameter Descriptions

You can set the sim_wand_key parameter to one or more control keys (Ctrl, Shift, Alt) and a character key (A to Z). For example: • Alt–A • Shift–Alt–B • Ctrl–Shift–C • Ctrl–Shift–Alt–D video_scan_row_select Purpose

Specifies the starting row number (0 to 15) of the 16 by 16 area of the display panel.

Default

0

Values

0 to 15

Function im_overlay_setup xmodem_receive_file_return Purpose

Specifies the value to be returned to your application when you use an im_xm_receive_file function to request that a file be sent to the terminal from the host using XMODEM protocol.

Default

00H - success

Values

00H - success 55H - general_error 56H - invalid_param 74H - connection_open_error 75H - connection_close_error 80H - file_open_error 84H - file_write_error 85H - file_close_error 11AH - timed_out_error 140H - malloc_error 150H - file_transfer_user_abort 151H - file_transfer_lost_connection 152H - file_transfer_receiver_cancelled 226H - invalid_com_port_number

30

Trakker Antares Application Simulator User's Manual

Page 309

Chapter 3, INI File Parameter Descriptions

Function im_xm_receive_file Notes

The Simulator does not receive or simulate receiving the file specified in the im_xm_receive_file function. If your application opens the file after receiving it, you must make sure that a copy of the file is in your current directory when you run the application with the Simulator. Otherwise, your open command will fail. You must test the application on a terminal to make sure that the application handles the communications protocols correctly and that the file is received on the terminal without error.

xmodem_transmit_file_return Purpose

Specifies the value to be returned to your application when you use an im_xm_transmit_file function to send a file from the terminal to the host using XMODEM protocol.

Default

00H - success

Values

00H - success 55H - general_error 56H - invalid_param 74H - connection_open_error 75H - connection_close_error 80H - file_open_error 84H - file_write_error 85H - file_close_error 11AH - timed_out_error 140H - malloc_error 150H - file_transfer_user_abort 151H - file_transfer_lost_connection 153H - file_transfer_transmitter_cancelled 226H - invalid_com_port_number

Function im_xm_transmit_file Notes

The Simulator does not transmit or simulate transmitting the file specified in the im_xm_transmit_file function. If your application opens the file before transmitting it, you must make sure that a copy of the file is in your current directory when you run the application with the Simulator. Otherwise, your open command will fail.

Trakker Antares Application Simulator User's Manual

31

Page 310

Chapter 3, INI File Parameter Descriptions

You must test the application on a terminal to make sure that the application handles the communications protocols correctly and that the file is transmitted to the DCS 300 without error.

xmodem1k_receive_file_return Purpose

Specifies the value to be returned to your application when you use an im_xm1k_receive_file function to request that a file be sent to the terminal from the host using XMODEM-1K protocol.

Default

00H - success

Values

00H - success 55H - general_error 56H - invalid_param 74H - connection_open_error 75H - connection_close_error 80H - file_open_error 84H - file_write_error 85H - file_close_error 11AH - timed_out_error 140H - malloc_error 150H - file_transfer_user_abort 151H - file_transfer_lost_connection 152H - file_transfer_receiver_cancelled 226H - invalid_com_port_number

Function im_xm1k_receive_file Notes

The Simulator does not receive or simulate receiving the file specified in the im_xm1k_receive_file function. If your application opens the file after receiving it, you must make sure that a copy of the file is in your current directory when you run the application with the Simulator. Otherwise, your open command will fail. You must test the application on a terminal to make sure that the application handles the communications protocols correctly and that the file is received on the terminal without error.

32

Trakker Antares Application Simulator User's Manual

Page 311

Chapter 3, INI File Parameter Descriptions xmodem1k_transmit_file_return Purpose

Specifies the value to be returned to your application when you use an im_xm1k_transmit_file function to send a file from the terminal to the host using XMODEM-1K protocol.

Default

00H - success

Values

00H - success 55H - general_error 56H - invalid_param 74H - connection_open_error 75H - connection_close_error 80H - file_open_error 84H - file_write_error 85H - file_close_error 11AH - timed_out_error 140H - malloc_error 150H - file_transfer_user_abort 151H - file_transfer_lost_connection 153H - file_transfer_transmitter_cancelled 226H - invalid_com_port_number

Function im_xm1k_transmit_file Notes

The Simulator does not transmit or simulate transmitting the file specified in the im_xm1k_transmit_file function. If your application opens the file before transmitting it, you must make sure that a copy of the file is in your current directory when you run the application with the Simulator. Otherwise, your open command will fail. You must test the application on a terminal to make sure that the application handles the communications protocols correctly and that the file is transmitted to the DCS 300 without error.

Trakker Antares Application Simulator User's Manual

33

Page 312

Chapter 3, INI File Parameter Descriptions ymodem_receive_file_return Purpose

Specifies the value to be returned to your application when you use an im_ym_receive_file function to request that a file be sent to the terminal from the host using YMODEM protocol.

Default

00H - success

Values

00H - success 55H - general_error 56H - invalid_param 74H - connection_open_error 75H - connection_close_error 80H - file_open_error 84H - file_write_error 85H - file_close_error 11AH - timed_out_error 140H - malloc_error 150H - file_transfer_user_abort 151H - file_transfer_lost_connection 152H - file_transfer_receiver_cancelled 226H - invalid_com_port_number

Function im_ym_receive_file Notes

The Simulator does not receive or simulate receiving the file specified in the im_ym_receive_file function. If your application opens the file after receiving it, you must make sure that a copy of the file is in your current directory when you run the application with the Simulator. Otherwise, your open command will fail. You must test the application on a terminal to make sure that the application handles the communications protocols correctly and that the file is received on the terminal without error.

34

Trakker Antares Application Simulator User's Manual

Page 313

Chapter 3, INI File Parameter Descriptions ymodem_transmit_file_return Purpose

Specifies the value to be returned to your application when you use an im_ym_transmit_file function to send a file from the terminal to the host using YMODEM protocol.

Default

00H - success

Values

00H - success 55H - general_error 56H - invalid_param 74H - connection_open_error 75H - connection_close_error 80H - file_open_error 84H - file_write_error 85H - file_close_error 11AH - timed_out_error 140H - malloc_error 150H - file_transfer_user_abort 151H - file_transfer_lost_connection 153H - file_transfer_transmitter_cancelled 226H - invalid_com_port_number

Function im_ym_transmit_file Notes

The Simulator does not transmit or simulate transmitting the file specified in the im_ym_transmit_file function. If your application opens the file before transmitting it, you must make sure that a copy of the file is in your current directory when you run the application with the Simulator. Otherwise, your open command will fail. You must test the application on a terminal to make sure that the application handles the communications protocols correctly and that the file is transmitted to the DCS 300 without error.

Trakker Antares Application Simulator User's Manual

35

Page 314

Chapter 3, INI File Parameter Descriptions

36

Trakker Antares Application Simulator User's Manual

Page 315

4

Customizing INI Files With the Editor

This chapter introduces the Simulator Editor and describes how to use it to customize the initialization (INI) file for the Trakker Antares® Application Simulator. This chapter covers these topics: • Introduction to the Simulator Editor • Starting the Simulator Editor • No INI file found • Introduction to the user interface • Creating a new INI file • Opening an existing INI file • Setting INI parameters • Saving changes • Discarding changes • Restoring the default values • Printing INI files • Exiting the Simulator Editor

Trakker Antares Application Simulator User's Manual

37

Page 316

Chapter 4, Customizing INI Files With the Editor

Introduction to the Simulator Editor The Simulator Editor is a Windows-based tool for viewing and setting the parameters stored in the IMT24SIM.INI file. The INI file contains parameters that specify how certain features are simulated. For descriptions of the parameters, see Chapter 3, “INI File Parameter Descriptions.” Note: Because IMT24SIM.INI is a text file, you can use any text editor to change the values of the parameters. You do not need to use the Simulator Editor. The Editor can be used with Intermec’s two application simulators: • Trakker Antares Application Simulator, which simulates applications for the Trakker Antares 2400 Family of terminals, including the 2425 handheld terminal and the 248X stationary terminal. • Trakker T2090 Application Simulator, which simulates applications for the T2090 computer.

Starting the Simulator Editor Start the Simulator Editor from the Trakker Antares Development Tools group on the Windows desktop or on the Start menu. The Editor window appears.

Simulator Editor Window

No INI File Found When you start the Editor, it attempts to open the default INI file, IMT24SIM.INI, in the working directory. If the Editor does not find the IMT24SIM.INI file in the working directory, the message, No ini file found, is displayed in the title bar of the window.

38

Trakker Antares Application Simulator User's Manual