Chapter 3, INI File Parameter Descriptions add_carriage_return Purpose
Enables or disables adding a carriage return character to the end of each buffer written to the portn_write_file using im_transmit_buffer.
Default
1 - enable
Values
0 - disable 1 - enable
Function im_transmit_buffer Notes
Each time you use im_transmit_buffer to write a string into the portn_write_file, the Simulator adds a carriage return character after the string. This helps delineate each string. If you disable this parameter, each string is appended directly to the previous string.
battery_status_return Purpose
Specifies the value to be returned when the application checks the power remaining in the main battery.
Default
100
Values
A number from 0 to 100 (in increments of ten)
Function im_battery_status Notes
You can use this parameter to test how the Trakker Antares application responds when the main battery power needs to be charged.
font_scan_row_select Purpose
Specifies the starting row number (0 to 15) of the glyph font to be displayed.
Default
0
Values
0 to 15
Function im_overlay_setup keypad_type Purpose
Specifies the Trakker Antares terminal keypad that the Simulator will mimic.
Default
0 - terminal emulation
Trakker Antares Application Simulator User's Manual
19
Page 298
Chapter 3, INI File Parameter Descriptions
Values
0 - terminal emulation 1 - programmable
Function im_receive_field im_receive_input Notes
Setting the keypad_type parameter is the equivalent of selecting the Configuration Menu, Terminal Menu, and Keypad from the TRAKKER Antares 2400 Menu System and then selecting the keypad type for the terminal. The Simulator can support Western European characters (such as é, ü, and õ) when you choose the programmable keypad. For help configuring the Simulator to support these characters, see “International Characters” on page 14.
label_preamble Purpose
Lets you add a user-defined string to the front of the label data. The userdefined string is specified in the label_preamble_string parameter.
Default
0 - disabled
Values
0 - disabled 1 - enabled
Function im_receive_field im_receive_input label_preamble_string Purpose
Specifies the user-defined string to be added to the front of the label data if the label_preamble parameter is enabled.
Default blank
Values
Any ASCII text
Function im_receive_field im_receive_input label_postamble
20
Purpose
Lets you append a user-defined string to the end of the label data. The user-defined string is specified in the label_postamble_string parameter.
Default
0 - disabled
Values
0 - disabled 1 - enabled
Trakker Antares Application Simulator User's Manual
Page 299
Chapter 3, INI File Parameter Descriptions
Function im_receive_field im_receive_input label_postamble_string Purpose
Specifies the user-defined string that can be appended to the end of the label data if the label_postamble parameter is enabled.
Default blank
Values
Any ASCII text
Function im_receive_field im_receive_input label_time_stamp Purpose
Specifies whether the current date and time will be appended to the label data.
Default
0 - disabled
Values
0 - disabled 1 - enabled
Function im_receive_field im_receive_input label_symbology Purpose
Specifies the symbology of the last simulated scanned label.
Default
1 – Code 39
Values
0 - Unknown 1 - Code 39 2 - Code 93 3 - Code 49 4 - Interleaved 2 of 5 (I 2 of 5) 5 - Codabar 6 - UPC/EAN 7 - Code 128 8 - Code 16K 9 - Plessey 10 - Code 11 11 - MSI
Function im_get_label_symbology im_receive_input
Trakker Antares Application Simulator User's Manual
21
Page 300
Chapter 3, INI File Parameter Descriptions
Notes
The value of this INI parameter is returned to the application in the symbology parameter of the function calls that use this INI parameter. When testing a Trakker Antares application, you can simulate the act of scanning a label by pressing the key sequence specified in the sim_wand_key parameter. When testing a T2090 application, you can press Ctrl-G to simulate scanning a label.
label_symbologyid Purpose
Specifies the AIM symbology ID of the data entered while simulating bar code input.
Default
None
Values
Enter up to four ASCII characters, such as ]A1.
Function im_get_label_symbologyid Notes
The value of this INI parameter is returned to the application in the symbologyID parameter of the function calls that use this INI parameter.
network_emulation Purpose
Specifies whether the network operations are emulated through ASCII data files, which are named in the network_read_file and network_write_file parameters.
Default
1 - enabled
Values
0 - disabled 1 - enabled
Function Not applicable network_read_file Purpose
Names the ASCII text file that contains data to be read by the application as if it were received on the network port (NET).
Default netread.rcv
Values
Any filename
Function im_receive_buffer im_receive_input Notes
22
Test the application on a terminal to ensure that the application is handling the input communications protocols correctly.
Trakker Antares Application Simulator User's Manual
Page 301
Chapter 3, INI File Parameter Descriptions
The PSK function you use to read data from the RCV file affects how you format the data in the file: • im_receive_buffer. Reads a buffer of data each time it is called. The RCV file should contain one or more data strings. Each data string is terminated by a CR/LF character, which indicates the end of the buffer. If there is no CR/LF, the function reads up to 1024 bytes of data. With each subsequent call, im_receive_buffer continues reading data where it left off in the file until it reaches an EOF. If the function is called again after reaching EOF, it starts reading data from the beginning of the file. • im_receive_input. Reads a line at a time, similar to im_receive_buffer. However, because im_receive_input accepts input from multiple sources, when the function reaches the EOF, it does not start reading data at the beginning of the file again. This practice allows keyboard, scanner, and wand input.
network_receive_file_return Purpose
Specifies the value to be returned to your application when you use an im_receive_file function to request that a file be sent to the terminal from the DCS 300.
Default
00H - success
Values
00H - success 56H - invalid_param 74H - net_open_error 75H - net_close_error 81H - request_failure 80H - file_open_error 85H - file_close_error 83H - receive_failure 84H - file_write_error 55H - general_error 11AH - timed_out_error 6BH - net_config_error 77H - net_write_error 86H - controller_deny
Function im_receive_file Notes
The Simulator does not receive or simulate receiving the file specified in the im_receive_file function. If your application opens the file after
Trakker Antares Application Simulator User's Manual
23
Page 302
Chapter 3, INI File Parameter Descriptions receiving it, you must make sure that a copy of the file is in your current directory when you run the application through the Simulator. Otherwise, your open command will fail. You must test the application on a terminal to make sure that the application handles the communications protocols correctly and that the file is received on the terminal without error.
network_transmit_file_return Purpose
Specifies the value to be returned to your application when you use an im_transmit_file function to send a file from the terminal to the DCS 300.
Default
00H - success
Values
00H - success 56H - invalid_param 74H - net_open_error 75H - net_close_error 81H - request_failure 80H - file_open_error 85H - file_close_error 83H - receive_failure 84H - file_write_error 55H - general_error 11AH - timed_out_error 6BH - net_config_error 77H - net_write_error 86H - controller_deny
Function im_transmit_file Notes
The Simulator does not transmit or simulate transmitting the file specified in the im_transmit_file function. If your application opens the file before transmitting it, you must make sure that a copy of the file is in your current directory when you run the application through the Simulator. Otherwise, your open command will fail. You must test the application on a terminal to make sure that the application handles the communications protocols correctly and that the file is transmitted to the DCS 300 without error
24
Trakker Antares Application Simulator User's Manual
Page 303
Chapter 3, INI File Parameter Descriptions network_write_file Purpose
Names the ASCII text file that will receive the data that the application writes to the network port.
Default netwrite.trx
Values
Any filename
Function im_transmit_buffer im_transmit_file Notes
Test the application on a terminal to make sure that the application is handling the output communications protocols correctly.
number_scan_line_select Purpose
Specifies the number of scan rows (1 to 16) of the glyph font to be displayed.
Default
1
Values
1 to 16
Function im_overlay_setup optical_input_n Purpose
Specifies the optical sensor input status while simulating optical sensor input. n in this parameter designates the optical sensor channel (1, 2, 3 or 4).
Default
0 - OFF
Values
0 - OFF 1 - ON
Function im_get_sensor_all im_get_sensor_input im_receive_field im_receive_input Notes
The value of this INI parameter is returned to the application in the optical sensor status parameter of the function calls that use this INI parameter. When testing an application, you can simulate the act of optical sensor input by pressing the key sequence specified in the sim_optical_key parameter. The optical sensor channel and optical state value parameter specifies the value of the simulated optical sensor input.
Trakker Antares Application Simulator User's Manual
25
Page 304
Chapter 3, INI File Parameter Descriptions portn_read_file Purpose
Names the ASCII text file that contains data to be read by the application as if it were received on a COM port. The n in portn_read_file is the COM port number (1, 2 or 3).
Default comportn.rcv, where n is the COM port number (1, 2 or 3)
Values
Any filename
Function im_receive_buffer im_receive_input Notes
Do not set this parameter to comn.rcv. Your PC will expect data from its own COMn port. Test the application on a terminal to make sure that the application is handling the input communications protocols correctly. The PSK function you use to read data from the RCV file affects how you format the data in the file: • im_receive_buffer. Reads a buffer of data each time it is called. The RCV file should contain one or more data strings. Each data string is terminated by a CR/LF character, which indicates the end of the buffer. If there is no CR/LF, the function reads up to 1024 bytes of data. With each subsequent call, im_receive_buffer continues reading data where it left off in the file until it reaches an EOF. If the function is called again after reaching EOF, it starts reading data from the beginning of the file. • im_receive_input. Reads a line at a time, similar to im_receive_buffer. However, because im_receive_input accepts input from multiple sources, when the function reaches the EOF, it does not start reading data at the beginning of the file again. This practice allows keyboard, scanner, and wand input.
portn_write_file Purpose
Names the ASCII text file that will receive data the application writes to a COM port. The n in portn_write_file is the COM port number (1, 2 or 3).
Default comportn.trx, where n is the COM port number (1, 2 or 3)
Values
Any filename
Function im_transmit_buffer im_transmit_file Notes
26
Do not set this parameter to comn.trx. Your PC will try to send data to its own COMn port. You must test the application on a terminal to make sure that the application is handling the output communications protocols correctly.
Trakker Antares Application Simulator User's Manual
Page 305
Chapter 3, INI File Parameter Descriptions scan_port_read_file Purpose
Identifies the ASCII file that contains data to be read by the application as if it were received on the scanner port.
Default scanport.rcv
Values
Any filename
Function im_receive_buffer im_receive_input Notes
Do not set this parameter to comn.rcv. Your PC will expect data from its COMn port. Test the application on a terminal to make sure the application is handling the communications protocols correctly. The PSK function you use to read data from the RCV file affects how you format the data in the file: • im_receive_buffer. Reads a buffer of data each time it is called. The RCV file should contain one or more data strings. Each data string is terminated by a CR/LF character, which indicates the end of the buffer. If there is no CR/LF, the function reads up to 1024 bytes of data. With each subsequent call, im_receive_buffer continues reading data where it left off in the file until it reaches an EOF. If the function is called again after reaching EOF, it starts reading data from the beginning of the file. • im_receive_input. Reads a line at a time, similar to im_receive_buffer. However, because im_receive_input accepts input from multiple sources, when the function reaches the EOF, it does not start reading data at the beginning of the file again. This practice allows keyboard, scanner, and wand input.
scan_port_write_file Purpose
Identifies the file that will receive data the application writes to the scanner port.
Default scanport.trx
Values
Any filename
Function im_receive_buffer im_receive_input Notes
Do not set this parameter to comn.trx. Your PC will try to send data to its COMn port. Test the application on a terminal to make sure the application is handling the communications protocols correctly.
Trakker Antares Application Simulator User's Manual
27
Page 306
Chapter 3, INI File Parameter Descriptions screen_type_select Purpose
Specifies the Trakker Antares terminal display type that the Simulator will mimic.
Default
0 - 20x16 (242X)
Values
0 - 20x16 (242X) 1 - 80x25 (2455 LCD display) 2 - 40x25 (2481/2486) 3 - 40x4 (2480/2485) 4 - 80x25 (2455 EL (electroluminescent) display) 5 - 16x2 (2460/2461) 6 - 20x16 (2410/2415)
Function im_get_display_type Notes
Setting this parameter is equivalent to selecting Configuration Menu, Terminal Menu, and Display from the TRAKKER Antares 2400 Menu System and then setting the display type for the terminal.
serial_port_emulation Purpose
Specifies whether the serial port operations are simulated.
Default
1 - enabled
Values
0 - disabled 1 - enabled
Function Not applicable Notes
For Trakker Antares applications, serial port operations are simulated through ASCII data files, which are named in the portn_read_file and portn_write_file (where n is 1, 2 or 3 to identify the port number).
serial_receive_mode Purpose
Specifies whether the Simulator receives serial data one line at a time (Line mode) or one character at a time (Character mode).
Default
0 - line_mode
Values
0 - line_mode 1 - character_mode
Function im_receive_buffer
28