Page 33

2

Using Terminal Emulation Applications

This chapter describes how to use the TE 2000 VT/ANSI Terminal Emulation application for your particular terminal.

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

9

Page 34

Chapter 2, Using Terminal Emulation Applications

Annunciators The terminal’s display reserves a location for annunciators (icons) that help you monitor RF and network communications, or alert you of a condition that requires action. Following are VT/ANSI TE annunciators. S X Keyboard action mode (KAM) has been set. The terminal ignores all keystrokes that send characters to the host. This state stays on until KAM is reset. S K The terminal is in Keypad mode. S C Terminal is in Character mode. The terminal sends each character as it is pressed. S B The terminal is in Line Edit (block) mode. When you press a terminating key, the terminal sends a block of characters to the host. S e The terminal is in Local Edit mode, which is a feature of the VT330/VT340 Terminal. For information about annunciators that indicate battery condition and general operational status, refer to the terminal’s user manual.

Main Keypad The VT/ANSI Terminal’s main keypad consists of standard keys and function keys. Standard keys generate letters, numbers, and symbols. Function keys generate special function codes. The following describes the keys. S Compose character The terminal does not support this function, which starts a compose sequence that creates characters that cannot be typed directly from the keyboard. S Ctrl The Ctrl key is used with another key to send a control code. S Delete Operation depends on how the DEL to BS option is set in the TE configuration menus. The key either sends a delete (DEL, 7F hexadecimal) or a backspace (BS, 08 hexadecimal). S Lock The Lock key alone does not send a code. It is used with shift-lock, which either sets or clears shift-lock. S Return Sends either a CR character (0D hexadecimal) or a CR character (0D hexadecimal) and an LF character (0A hexadecimal), depending on the set or reset state of line feed or new line mode (LNM).

10

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 35

Chapter 2, Using Terminal Emulation Applications

S Shift The Shift key alone does not send a code. It is used with other standard keys to send uppercase characters. S Space bar Sends an SP character (20 hexadecimal). S Tab Sends an HT character (09 hexadecimal). To enter a function key: Press the keys listed in the section for the terminal. Or, scan the following bar codes (also in Appendix A, “Bar Code Scanning”). Backspace

*/EBKSP* *%BKSP* Delete (Del)

*/EDEL* *%DEL*

Editing Keypad The terminal’s editing keypad has editing keys and cursor (arrow) keys.

Cursor Keys You can use cursor keys and paging keys to manually move the terminal’s window/viewport. See the terminal user manual for more information.

Editing Keys Editing keys have functions assigned to them by the application software in use. Refer to your application’s software manual for information about editing key functions. Editing keys are Find, Insert, Next Screen, Previous Screen, Remove, and Select. To enter an editing key: Press the keys listed in the section for the terminal. Or, scan the following bar codes (also in Appendix A, “Bar Code Scanning”). Find (VT220/320 only)

*/EFIND* *%FIND* Insert (VT220/320 only)

*/EINS* *%INS*

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

11

Page 36

Chapter 2, Using Terminal Emulation Applications

Next Screen (VT220/320 only)

*/ENEXT* *%NEXT*

Previous Screen (VT220/320 only)

*/EPREV* *%PREV*

Remove (VT220/320 only)

*/EREM* *%REM*

Select (VT220/320 only)

*/ESEL* *%SEL*

Auxiliary Keys The VT/ANSI terminal’s auxiliary keypad consists of numeric keys (which enter numeric data) and programmable function (PF) keys. The following chart describes VT/ANSI terminal auxiliary keypad operations. S 0–9 Enters numeric data. S – (hyphen) Enters a hyphen character. S , (comma) Enters a comma character. S . (period) Enters a period character. S Enter Sends CR, CRLF, or SS# M, depending on the mode settings. S PF1 – PF4 The application software in use assign operations to these PF keys. See the application software manual for programmed uses of these keys. To enter an auxiliary key: Press the keys while the terminal is in Keypad mode. Or, scan the bar code in Appendix A, “Bar Code Scanning”.

12

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 37

Chapter 2, Using Terminal Emulation Applications

Top-Row Function Keys VT220/320/340 terminals support function keys F1 through F20. Keys F1 through F5 are used for hold screen, print screen, set-up, data/talk, and break. The terminal supports only the break function. For VT220/320/340, F1 through F4 are PF1 through PF4. S F5 (Break) Sends a break function to the host. S F6–F20 User-defined keys (UDKs) that have operations assigned to them by the application software in use. Refer to your application’s software manual for their uses. Note: VT100 Terminals only support top-row function keys F11 (Escape), F12 (Backspace), and F13 (Line feed). To enter a top-row function key: Press the keys listed in the section for the terminal. Or, scan the bar code in Appendix A, “Bar Code Scanning”.

Transmission Mode Use the transmission mode (labeled “Mode” on the overlay) to toggle between Line Edit (block) mode and Character mode. These modes are described in Chapter 6, “Programming.” When Lock mode is disabled, you can press the Mode key to toggle between Line Edit (block) mode and Character mode. When Lock mode is enabled, you cannot toggle between the modes. By default, Lock mode is disabled. You can configure Lock mode through the TE configuration menus. See Chapter 4, “Using the Terminal Emulation Menus,” for information about the menus.

Local Edit Mode If your application software program supports local editing, you can use the terminal in Local Edit Mode, a feature of the VT330/ VT340 terminal. Local Edit Mode is described in Chapter 6, “Programming.”

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

13

Page 38

Chapter 2, Using Terminal Emulation Applications

VT/ANSI Printing and Serial Scanning You can print data from a VT/ANSI host. If you are using a 2415, 2425, 2435A, 2455, 2475, or 248X Terminal, you can use different methods to connect it to your printer depending on the type of terminal and printer you have. To connect your terminal to a printer, refer to the terminal’s user manual for instructions.

Using the Print Modes The following chart defines the print modes you can use with the VT/ANSI TE application. S Auto print Prints each line after the cursor leaves that line using a carriage return or when auto-advancing through fields. This mode can be turned on and off from a VT/ANSI host. S Printer controller Prints all data from a VT/ANSI host. Turn this mode on or off from the host as all host screens are printed without allowing the user to respond. You cannot log on or off while in this mode. S Print cursor line Prints the line that the cursor is on. This mode can only be turned on from a VT/ANSI host and turns off after the line prints. S Print form feed After a screen is printed, the printer advances the printed screen out of the printer. This mode can be turned on and off from a VT/ANSI host. To send commands from the host, refer to the programmer’s guide for your VT/ANSI host for help.

Configuring Printing and Serial Scanning Options The following instructions explain how to set printing and serial scanning options. The method depends on the type of terminal you are using.

2415, 2425, 2435A, 2455, 2475, or 248X Terminals 1 Connect your terminal to a printer or scanner. 2 Open the TRAKKER Antares 2400 Menu System. 3 Configure the terminal’s serial port to match the parameters set for the serial port on either the printer or the scanner. Flow Control must be set to XON/XOFF on both the terminal and the printer. For help configuring the parameters, refer to your terminal’s user manual. Note that the baud rate must match the terminal’s printer settings and the data bits, stop bits, and parity must match the terminal’s serial port settings. 1 Open the TRAKKER Antares 2400 Menu System firmware. 2 From the Main Menu, choose Configuration Menu → Communications Menu → Serial Port, then configure the serial port parameters. See the terminal’s user manual for help.

14

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 39

Chapter 2, Using Terminal Emulation Applications

Do the following to set the RS232 Stream option: 1 Open the TE configuration menus. For the correct key sequence, see Chapter 1, “Getting Started.” 2 From the Main Menu, select 1) Set-up Parms, then enter cr52401 at the Enter Password prompt. 3 Select 3) Protocol Opts, 6) VT/ANSI, then 7) More. 4 Select 7) More again. 5 Enable or disable the RS232 Stream option.

6400, 5055, 59XX, 17XX, 11XX Terminals 1 Connect your terminal to a printer or scanner. 2 Configure the terminal’s serial port to match the parameters set for the serial port on either the printer or the serial scanner from the Main Menu. From the Main Menu, select 1) Set-up Parms, then enter cr52401 at the Enter Password prompt. 3 Select 3) Protocol Opts, 6) VT/ANSI, then 7) More. 4 Select 4) RS232 Setup, then set the baud rate, parity, stop bits, data bits, or flow.

5020 Data Collection PC 1 Connect your data collection pc to a printer or serial scanner. 2 Open the TRAKKER Antares 2400 Menu System firmware. 3 Note that the baud rate must match the terminal’s printer or serial scanner settings. From the Main Menu, choose Configuration Menu → Communications Menu → Serial Port, then configure the baud rate. See the 5020 Data Collection PC User’s Manual (P/N: 068975) for assistance.

700 Series Mobile Computer 1 Connect your mobile computer to a printer. 2 Configure the serial port on the mobile computer to match the parameters set for the serial port on the printer. From the Main Menu, select 1) Set-up Parms, then enter cr52401 at the Enter Password prompt. 3 Select 3) Protocol Opts, 6) VT/ANSI, then 7) More. 4 Select 4) RS232 Setup, then set the baud rate. See the 700 Series Color Mobile Computer User’s Manual (P/N: 961-054-031) or the 700 Series Monochrome Mobile Computer User’s Manual (P/N: 961-054-032) for assistance.

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

15

Page 40

Chapter 2, Using Terminal Emulation Applications

16