Page 25

1

Getting Started

This chapter introduces the TE 2000t terminal emulation application.

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

1

Page 26

Chapter 1, Getting Started

Understanding Network Protocol Options TE 2000 applications for the Enterprise Wireless LANt system use one of the following network protocol options: S UDP Plus The terminal communicates with the host computer through the IntermecR Data Collection Server (DCS) 300 and an access point. S TCP/IP The terminal communicates through an Intermec access point, which is directly connected to the host computer on an Ethernet or a token ring network. S WTP The terminal communicates with the host computer through the DCS 300, Intermec access point, or other Intermec gateways. For network configuration options, refer to your terminal’s user manual.

Setting Up the Terminal and the Network Before you can start using the TE 2000 application on your terminal, you need to do the following: 1 Set up your terminal. Set-up includes charging and installing the battery pack and turning on the terminal for the first time. For instructions, refer to your terminal’s user manual. Note: Battery packs do not apply to all terminals. Vehicle mount and stationary terminals are powered via an external source. 2 Configure your terminal and the network. To use RF communications on the terminal, you need to: a Configure the DCS 300 (UDP Plus or WTP), other INTERMEC gateway (WTP), or host (TCP/IP). b Configure the access point. This does not apply to the 2480/2481 Terminal, which contains an Ethernet NIC instead of a radio. c Configure the network parameters on the terminal. For instructions, refer to your terminal’s user manual. 3 Verify that your terminal is communicating correctly with the access point and DCS 300 or the host. To verify that your terminal is communicating correctly, refer to the terminal’s user manual for instructions.

2

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 27

Chapter 1, Getting Started

Starting the TE 2000 Application You are ready to start your application once the terminal has been set up, the terminal and the network have been configured, and communications have been established with the gateway and access point or host. To start your application: Turn on the terminal. Wait a few seconds while the initialization screens (below) clear and the application starts.

COPR. 1991-2003 INTERMEC. ALL RIGHTS RESERVED V<version number> <release date>

TE 2000(TM)

<program name> <version> Host: <host name> <emulation type>

Note: If your application does not start after a few seconds, you may not have configured the terminal correctly. For help, refer to your terminal’s user manual. You can now do one of the following: S Become familiar with VT/ANSI TE if you have not previously used it S Perform a quick configuration S Configure your TE 2000 application S Customize your TE 2000 application

Becoming Familiar With VT/ANSI Terminal Emulation If you have not previously used VT/ANSI TE, see Chapter 2, “Using Terminal Emulation Applications,” to understand VT/ANSI commands. See Chapter 3, “Using the Terminal’s Keyboard,” to become familiar with your terminal’s keyboard and the keys you need to press to perform VT/ANSI commands. TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

3

Page 28

Chapter 1, Getting Started

Performing a Quick Configuration Note: For Terminal Emulation Version 6.60 or greater, the default data stream is “VT/ANSI.” 1 Change the data stream to VT/ANSI. The default data stream is “Native” for the 6400 (WTP), 5055 (WTP), 59XX, 17XX, and 11XX Terminals,. The default data stream for 2415, 2425, 2435A, 2455, 2475, 248X, and IP terminals is “3270.” a Access the terminal emulation configuration menus by pressing the following keys, then choose 1) Set-up Parms from the Main Menu. Terminal

Key Sequence

2415

) ! (55-key keyboard) ( 5 (37-key keyboard)

2425

(!

2435A r l (57-key keyboard) [Green] > [Orange] > (48-key keyboard) r l (39-key function numeric keyboard)

2455, 2475, 248X

(¡

6400

[Gold] [Blue]

5055

[Blue] [M] or [ALT] [M]

59XX

[Brown] [Space]

17XX, 11XX

[Gold] [Black]

Note: Press a number to select a menu option, then press [Enter] to return to a previous menu. b At the Enter Password prompt, enter cr52401. On 17XX (37-key) Terminals, the password is: F12 F11 5 2 4 0 1 c From the Set-up Parms menu, select 3) Protocol Opts, 2) Data Stream, then 4) VT/ANSI. 2 Extended commands transmit or receive data over the terminal’s RS-232 port, send information to an RS-232 device, or collect data. Enable the Extended Cmds option if your host computer is configured to send extended commands to the terminal. It is disabled by default. From the Protocol Opts menu, select 3) Extended Cmds, then 1) Enabled. 3 From the Main Menu, select 7) More, then 2) Save Parms. 4 At the Enter Password prompt, type cr52401, then press enter. On 17XX (37-key) Terminals, the password is: F12 F11 5 2 4 0 1 5 From the Main Menu, select 6) Exit Menus. Note: For WTP devices, you should also set a terminal number. 6 Log in to a TE session, then use the terminal to collect/transmit data.

4

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 29

Chapter 1, Getting Started

Configuring the TE 2000 Application You can use the terminal’s TE configuration menus to configure site-specific operational parameters, including UDP Plus, WTP, or TCP/IP communications, terminal emulation options, and the Main Menu password. For information about configuring the terminal, see Chapter 4, “Using the Terminal Emulation Menus.”

Using Advanced Features You can customize the standard TE 2000 program to do the following. For more information, see Chapter 5, “Customizing Your Configuration.” S Use the auto-login feature to send the same login information each time you login to the host. S Display double-byte characters. S Create a custom parameter set-up file. S Change the text of TE configuration menus or system messages. S Remap the terminal’s keys. S Preinitialize the VT/ANSI TE program.

Unsupported Commands and Functions TE 2000 Terminal Emulation for the 2415, 2425, 2435A, 2455, 2475, and 248X Terminals does not support the following commands and functions, which were supported in previous versions. S End (viewport) Moved window or viewport to the end of the last line displayed on the TE screen. S Fast Cursor Right or Left Moved the cursor two positions to the right or left rather than one. S Home (viewport) Moved the window or viewport to the top left corner of the TE screen. S Reshow Resent screen image from local host buffer to refresh terminal screen. S Status Toggled terminal screen between status line, normal field input displays. S Status line messages Reported the operating status of the terminal and host system. S Dual sessions Not supported in Trakker Antares UDP Plus or TCP terminals. If you scan the bar code for an unsupported command, the bar code data is read into the terminal. If you press the key sequence for the command, the sequence is ignored. TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

5

Page 30

Chapter 1, Getting Started

Program Names The following chart lists TE options and program names. Note: TE 2000 does not support SST (Spread Spectrum Transmission) or regular UHF. “S-UHF” is synthesized UHF. Model

Option

2415, 2425, 2435A, 2455, 2475, 248X

TE/WTP/2.4 GHz OpenAir TE/WTP/802.11 TE/UDP Plus/2.4 GHz OpenAir TE/UDP Plus/802.11 TE/IP/2.4 GHz OpenAir TE/IP/802.11

6400

TE/WTP/2.4 GHz OpenAir TE/WTP/802.11 TE/WTP/900 MHz Falcon TE/IP/2.4 GHz OpenAir TE/IP/802.11

5020

TE/UDP Plus/2.4 GHz OpenAir TE/UDP Plus/802.11 TE/IP/2.4 GHz OpenAir TE/IP/802.11

FWP502H0

5055

TE/WTP/2.4 GHz OpenAir TE/WTP/802.11 TE/IP/2.4 GHz OpenAir TE/IP/802.11

FWP650H0 FWP650H0 FWP65TH0 FWP65TH0

59XX

TE/WTP TE/WTP TE/WTP/2.4 GHz OpenAir TE/WTP/900 MHz Falcon TE/WTP/S-UHF

FWP592H0 FWP594H0 FWP598H0 FWP596H0 FWP591H1

17XX

TE/WTP TE/WTP TE/WTP/2.4 GHz OpenAir TE/WTP/900 MHz Falcon TE/WTP/S-UHF

11XX

TE/WTP TE/WTP TE/WTP/2.4 GHz OpenAir TE/WTP/900 MHz Falcon TE/WTP/S-UHF

FWP110H0 FWP114H0 FWP118H0 FWP116H0 FWP111H0

700 Series

TE/IP/802.11

FWP700H0

6

Program Name FWP240H0

51-key keyboard FWP640H0 FWP640H0 FWP640H0 FWP64TH0 FWP64TH0

57-key keyboard FWP170H0 FWP174H0 FWP178H0 FWP176H0 FWP171H0

41-key keyboard FWP640H4 FWP640H4 FWP640H4 FWP64TH4 FWP64TH4

37-key keyboard FWP170H3 FWP174H3 FWP178H3 FWP176H3 FWP171H3

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 31

Chapter 1, Getting Started

VT/ANSI Standard Terminal Keyboard

Main Keypad

Top-Row Function Keys

Editing Keypad

Auxiliary Keypad

As you read how your terminal’s keyboard emulates VT/ANSI operation, you may want to frequently refer to the following illustration for your terminal.

This illustration is of the VT/ANSI Terminal Standard North American Keyboard.

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

7

Page 32

Chapter 1, Getting Started

8