The text of a manual · part 32 of 52
TE 2000 VT/ANSI Terminal Emulation Programmer's Guide: Chapter 5: Customizing Your Configuration, pages 266 to 274
Pages 266 to 274 of 456, from TE 2000 VT/ANSI Terminal Emulation Programmer's Guide
The original document is the PDF (3.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2425
Page 266
Chapter 5, Customizing Your Configuration
Generic Bar Code Options (continued)
Options
[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values
Terminals using this option
Fixed Length 1 upc|fix_length_1 ean|fix_length_1 code_128|fix_length_1 code_39|fix_length_1 codabar|fix_length_1 abc_codabar|fix_length_1 str_2of5|fix_length_1 int_2of5|fix_length_1 ci_2of5|fix_length_1 code_11|fix_length_1 code_93|fix_length_1 plessey|fix_length_1
Numeric, minimum = 0, maximum = 99 [0]
700 Series, CK30, CK31, CV60
Fixed Length 2 upc|fix_length_2 ean|fix_length_2 code_128|fix_length_2 code_39|fix_length_2 codabar|fix_length_2 abc_codabar|fix_length_2 str_2of5|fix_length_2 int_2of5|fix_length_2 ci_2of5|fix_length_2 code_11|fix_length_2 code_93|fix_length_2 plessey|fix_length_2
Numeric, minimum = 0, maximum = 99 [0]
700 Series, CK30, CK31, CV60
Fixed Length 3 upc|fix_length_3 ean|fix_length_3 code_128|fix_length_3 code_39|fix_length_3 codabar|fix_length_3 abc_codabar|fix_length_3 str_2of5|fix_length_3 int_2of5|fix_length_3 ci_2of5|fix_length_3 code_11|fix_length_3 code_93|fix_length_3 plessey|fix_length_3
Numeric, minimum = 0, maximum = 99 [0]
700 Series, CK30, CK31, CV60
Fixed Length 4 upc|fix_length_4 ean|fix_length_4 code_128|fix_length_4 code_39|fix_length_4 codabar|fix_length_4 abc_codabar|fix_length_4 str_2of5|fix_length_4 int_2of5|fix_length_4 ci_2of5|fix_length_4 code_11|fix_length_4 code_93|fix_length_4 plessey|fix_length_4
Numeric, minimum = 0, maximum = 99 [0]
700 Series, CK30, CK31, CV60
242
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
Page 267
Chapter 5, Customizing Your Configuration
Generic Bar Code Options (continued)
Options
[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values
Terminals using this option
Maximum Length upc|max_length ean|max_length code_128|max_length code_39|max_length codabar|max_length abc_codabar|max_length str_2of5|max_length int_2of5|max_length ci_2of5|max_length code_11|max_length code_93|max_length plessey|max_length
Numeric, minimum = 0, maximum = 99 [0]
700 Series, CK30, CK31, CV60
Minimum Length upc|min_length ean|min_length code_128|min_length code_39|min_length codabar|min_length abc_codabar|min_length str_2of5|min_length int_2of5|min_length ci_2of5|min_length code_11|min_length code_93|min_length plessey|min_length
Numeric, minimum = 0, maximum = 99 [0]
700 Series, CK30, CK31, CV60
UPC Options Note that brackets indicate default settings and values. UPC Options
Options
[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values
Add-On 2 upc|add-on_2
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Add-On 5 upc|add-on_5
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Expand E to A upc|expand_e_to_a
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
System 0 UPCE upc|sys_0_upce
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
System 1 UPCE upc|sys_1_upce
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
Terminals using this option
243
Page 268
Chapter 5, Customizing Your Configuration
EAN Options Note that brackets indicate default settings and values. EAN Options
Options
[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values
Add-On 2 ean|add-on_2
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Add-On 5 ean|add-on_5
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Expand 8 to 13 ean|expand_8to13
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Terminals using this option
Code 39 Options Note that brackets indicate default settings and values. Code 39 Options
Options
[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values
Auto-Encoded code_39|auto-encoded
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Check Digit code_39|chk_digit
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Data Decode code_39|data_decode
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Element Decode code_39|element_decod
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Encoded code_39|encoded
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Extended code_39|extended
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Full ASCII code_39|full_ascii
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Quiet Zone code_39|quiet_zone
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
START Decode code_39|start_decode
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
244
Terminals using this option
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
Page 269
Chapter 5, Customizing Your Configuration
Interleaved 2 of 5 Option Note that brackets indicate default settings and values. Interleaved 2 of 5 Options
Options Interleaved 2 of 5 Chk Digit
[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values interleaved_2_of_5_chk_digit
Enabled, [Disabled]
Terminals using this option 700 Series, CK30, CK31, CV60
Code 11 Options Note that brackets indicate default settings and values. Code 11 Options
Options
[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values
Check Digit 1 code_11|chk_dig_1
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Check Digit 2 code_11|chk_dig_2
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Terminals using this option
Plessey Options Note that brackets indicate default settings and values. Plessey Options
Options
[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values
Allow Alpha plessey|allow_alpha
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
MOD 10 Check plessey|mod10_chk
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
MOD 11 Check plessey|mod11_chk
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
Terminals using this option
245
Page 270
Chapter 5, Customizing Your Configuration
Code 128 Options Note that brackets indicate default settings and values. Code 128 Options
Options
[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values
No UCC Type code_128|no_ucc_type
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
UCC/EAN code_128|ucc/ean
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
UCC F1 Value upc|ucc_f1_value ean|ucc_f1_value code_128|ucc_f1_value code_39|ucc_f1_value codabar|ucc_f1_value abc_codabar|ucc_f1_value str_2of5|ucc_f1_value int_2of5|ucc_f1_value ci_2of5|ucc_f1_value code_11|ucc_f1_value code_93|ucc_f1_value plessey|ucc_f1_value
Numeric, minimum = 0, maximum = 255
700 Series, CK30, CK31, CV60
Terminals using this option
VT/ANSI Protocol Options Note that brackets indicate default settings and values. VT/ANSI Protocol Options
Options
[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values
Allow LineMode allow_linemode
[Enabled], Disabled
700 Series, CK30, CK31, CV60
Allow Negotiate About Window Size (NAWS)
allow_naws
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
AnswerBack answerback
String, minimum length=0, maximum length = 30*
700 Series, CK30, CK31, CV60
Terminals using this option
*The default string default is the terminal serial number Any Auto Enter any_auto_enter
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Auto Enter Scan auto_entr_scn
[Enabled]*, [Disabled]**
700 Series, CK30, CK31, CV60
* [Enabled] is the default for TE 2000 application version 6.60 or greater. ** [Disabled] is the default for TE 2000 application versions less than 6.60. Auto Tab Scan
246 auto_tab_scan
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
Page 271
Chapter 5, Customizing Your Configuration
VT/ANSI Protocol Options (continued)
Options
[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values
Auto Wrap auto_wrap
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
CR to CRLF cr_to_crlf
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
DEL to BS del_to_bs
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Do Gold Key do_gold_key
[Enabled], Disabled
700 Series, CK30, CK31, CV60
Do UTF-8 do_utf8
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Extended Commands extended_cmds
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Host View Columns host_view_cols
Numeric, minimum = 1, maximum = 255 [24]
700 Series, CK30, CK31, CV60
Host View Rows host_view_rows
Numeric, minimum = 1, maximum = 255 [80]
700 Series, CK30, CK31, CV60
Keypad Mode keypad_mode
[Numeric], Application
700 Series, CK30, CK31, CV60
Local Echo local_echo
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Lock Mode lock_mode
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
RS-232 Baud Rate rs232_baudrate
[9600], 19200, 38400, 57600, 115200
700 Series, CK30, CK31, CV60
Screen Lock screen_lock
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Send XON send_xon
[Enabled], Disabled
700 Series, CK30, CK31, CV60
Telnet telnet
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Terminal Mode terminal_mode
[7-Bit], 8-Bit
700 Series, CK30, CK31, CV60
Terminal Type terminal_type
String, minimum = 0, maximum = 30, [Null string, not defined]
700 Series, CK30, CK31, CV60
Terminal Setup term_setup
ANSI, VT100, VT220, 700 Series, CK30, VT320, [VT340], IBM CK31, CV60 330x
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
Terminals using this option
247
Page 272
Chapter 5, Customizing Your Configuration
VT/ANSI Protocol Options (continued)
Options
[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values
Transmit BS transmit_bs
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
Use PC Character Set use_pc_char_set
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
User Key Locked userkey_locked
Enabled, [Disabled]
700 Series, CK30, CK31, CV60
VT Cursor Mode vt_cursor_mode
[Cursor], Application
700 Series, CK30, CK31, CV60
VT220 Mode vt220_mode
[Char], Block
700 Series, CK30, CK31, CV60
Terminals using this option
Display Options Note that brackets indicate default settings and values. Display Options
Options
[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values
Backlight State backlight_state
[Enabled], Disabled
700 Series, CK30, CK31, CV60
Backlight Timer backlight_timer
Numeric, minimum = [0], maximum = 255
700 Series
Code Page code_page
[English], Cyrillic (Russian), Greek, Hebrew, Central Europe, Latin 2
700 Series, CK30, CK31, CV60
Cursor Mode cursor_mode
Underln Blink Block Blink Underline [Block]
700 Series, CK30, CK31, CV60
Font Quality font_quality
[Standard], Clear Type
CK30, CK31
Select Font select_font
Lucida]*, [Courier New]**, [Courier New Bold]***, Tahoma
700 Series, CK30, CK31, CV60
Terminals using this option
* [Lucida] is the default for CK30, CK31. ** [Courier New] is the default for CV60. *** [Courier New Bold] is the default for 700 Series.
248
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
Page 273
Chapter 5, Customizing Your Configuration
More Options Note that brackets indicate default settings and values. More Options
Options Change Menu Password
[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values change_menu_password
String, minimum length = 1, maximum length = 10 [3193693] To enable the password, see “Main Menu password.”
Terminals using this option 700 Series, CK30, CK31, CV60
You must enable and set the password to access the Main Menu before changing it. To set the password, see above. Main Menu Password menu_password
Enabled, [Disabled] To set the password, see “Change menu password.”
700 Series, CK30, CK31, CV60
You must enable and set the password to access the Main Menu. To enable or disable the password, see above. Print Device print_device
[RS232 Print], 700 Series, CK30, IRDA Print (700 Series, CK31, CV60 CV60) RF Print (700 Series, CK30, CK31, CV60) Pan Print (700 Series, CK30 Bluetooth Printing)
Printer Address printer_address
String, minimum length=0, maximum length=16 [null string]
700 Series, CK30, CK31, CV60
Printer Port printer_port
Numeric, minimum = 0, maximum = 65535 [23]
700 Series, CK30, CK31, CV60
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
249
Page 274
Chapter 5, Customizing Your Configuration
LCD Options Note that brackets indicate default settings and values. LCD Options
Options
[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values
Annunciator Format annun_format
[Vertical]*, [Horizontal]**
Terminals using this option 700 Series, CK30, CK31, CV60
* [Vertical] is the default for 700 Series, CK30, CK31. ** [Horizontal] is the default for CV60. Annunciator Position annun_position
Upper Right, Upper Left, [Lower Right]*, Lower Left, [Stealth]**
700 Series, CK30, CK31, CV60
* [Lower Right] is the default for 700 Series, CK30, CK31. ** [Stealth] is the default for CV60. Define Height (Scroll Window)
define_height
Numeric, minimum = 1, maximum = 24 [8]
700 Series, CK30, CK31, CV60
Define Width (Scroll Window)
define_width
Numeric, minimum = 1, maximum = 80 [8]
700 Series, CK30, CK31, CV60
Key Uppercase key_uppercase
[Enabled], Disabled
700 Series, CK30, CK31, CV60
Screen Columns screen_cols
Numeric, minimum = 1, maximum = 255 16, 17, 19, 20, 40, [80]*, [16]**
700 Series, CK30, CK31, CV60
* [80] is the default for CV60. ** [16] is default for 700 Series, CK30, CK31. Screen Mode screen_mode
Center Cursor, [Corner 700 Series, CK30, Mode], Page Mode, CK31, CV60 Lazy Mode, Locked Mode
Screen Rows screen_rows
Numeric, minimum = 1, maximum = 255 8, 8, [10]*, 16, 17, [25]**, 16
700 Series, CK30, CK31, CV60
* [10] is the default for 700 Series, CK30, CK31. ** [25] is the default for CV60. Scroll Window scroll_window
Screen Size, Scroll Setting, [Tab Size]
700 Series, CK30, CK31, CV60
XOrigin xorigin
Numeric minimum = 0, maximum = 79 [0]
700 Series, CK30, CK31, CV60
YOrigin yorigin
Numeric minimum = 0, maximum = 23 [0]
700 Series, CK30, CK31, CV60
250
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide