Page 257

Chapter 5, Customizing Your Configuration

LCD Options Note that brackets indicate default settings and values. LCD Options

Options

[Session 1] Session 2 Session 3 (700 Series, CV60) Session 4 (700 Series, CV60)

Annunciator Format Annun Format

Values [Vertical]*, [Horizontal]**

* [Vertical] is the default for 2455, 2475, 248X, 5020, 5055, 59XX, 700 Series, CK30. ** [Horizontal] is the default for 2415, 2425, 2435A, 6400, CV60.

Terminals using this option 2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 11XX, 17XX, 59XX, 700 Series, CK30, CV60

Annunciator Position

Annun Position

Upper Right, Upper Left, 2415, 2425, 2435A, [Lower Right]*, Lower Left, 2455, 2475, 248X, [Stealth]** 6400, 5020, 5055, 11XX, 17XX, 59XX, * [Lower Right] is the default for 6400, 5020, 5055, 59XX, 17XX, 11XX, 700 Series, 700 Series, CK30, CV60 CK30. ** [Stealth] is the default for 2415, 2425, 2435A, 2455, 2475, 248X, CV60. Backlight Intensity

BLight Intensity

Numeric, minimum = 0, maximum = 15

59XX

Define Height (Scroll Window)

Define Height

Numeric, minimum = 1, maximum = 24 [8]

2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 11XX, 17XX, 59XX, 700 Series, CK30, CV60

Define Width (Scroll Window)

Define Width

Numeric, minimum = 1, maximum = 80 [8]

2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 11XX, 17XX, 59XX, 700 Series, CK30, CV60

Key Uppercase

Key Uppercase

[Enabled], Disabled

2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 11XX, 17XX, 59XX, 700 Series, CK30, CV60

LCD Contrast

LCD Contrast

Numeric, minimum = [0], maximum = 255

17XX, 59XX

Screen Columns

Screen Cols

Numeric, minimum = 1, maximum = 255 [16]*, [17]**, [19]***, [20]****, [40]*****, [80]******, [16]*******

2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 11XX, 17XX, 59XX, 700 Series, CK30, CV60

* [16] is the default for 11XX. ** [17] is the default for 17XX. *** [19] is the default for 2435A. **** [20] is the default for 2415, 2425, 2455, 2475, 2481, 2486. ***** [40] is the default for 2480, 2485, 59XX. ****** [80] is the default for 5055, CV60. ******* [16] is default for 6400 Wide Display, 5020, 700 Series, CK30. Screen Mode

Screen Mode

Center Cursor, [Corner Mode], Page Mode, Lazy Mode, Locked Mode

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 11XX, 17XX, 59XX, 700 Series, CK30, CV60

233

Page 258

Chapter 5, Customizing Your Configuration

LCD Options (continued)

Options

[Session 1] Session 2 Session 3 (700 Series, CV60) Session 4 (700 Series, CV60)

Screen Rows

Screen Rows

Values

Terminals using this option

Numeric, minimum = 1, maximum = 255 [8]*, [8]**, [10]***, [16]****, [17]*****, [25]******, [16]*******

2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 11XX, 17XX, 59XX, 700 Series, CK30, CV60

* [8] is the default for 11XX. ** [8] is the default for 17XX. *** [10] is the default for 5020, 59XX, 700 Series, CK30. **** [16] is the default for 2415, 2425, 2435A, 2455, 2475, 2481, 2486. ***** [17] is the default for 2480, 2485. ****** [25] is the default for 5055, CV60. ******* [16] is the default for 6400 Wide Display. Scroll Window

Scroll Window

Screen Size, Scroll Setting, [Tab Size]

2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 11XX, 17XX, 59XX, 700 Series, CK30, CV60

XOrigin

XOrigin

Numeric minimum = 0, maximum = 79 [0]

2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 11XX, 17XX, 59XX, 700 Series, CK30, CV60

YOrigin

YOrigin

Numeric minimum = 0, maximum = 23 [0]

2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 11XX, 17XX, 59XX, 700 Series, CK30, CV60

Beeper Setup Options Note that brackets indicate default settings and values. Beeper Setup Options Options

[Session 1] Session 2

Values

Terminals using this option

Beep Head Set

Beep Head Set

Enabled, [Disabled]

17XX

Beep Internal

Beep Internal

[Enabled], Disabled

6400, 5055, 11XX, 17XX

Numeric, minimum = 0, maximum = 30 [13]*, [6]**

6400, 5055, 11XX, 17XX

Beeper (Error Tone) Beep Frequency Frequency

* [13] is the default for 17XX, 11XX. ** [6] is the default for 6400. Beeper (Error Tone) Beep Length Length

Numeric, minimum= 1 , maximum= 10 [3]

6400, 5055, 11XX, 17XX, 59XX

Beeper (Error Tone) Beep Volume Volume

Numeric, minimum = 0, maximum = 255 [95]

59XX

Key Click Frequency

Numeric, minimum = 0, maximum = 30 [13]*, [6]**

6400, 5055, 11XX, 17XX

KeyClick Freq

* [13] is the default for 17XX, 11XX. ** [6] is the default for 6400.

234

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

Page 259

Chapter 5, Customizing Your Configuration

Beeper Setup Options (continued) Options

[Session 1] Session 2

Key Click Length

KeyClick Length

Values Numeric, minimum = 1, maximum = 10 [1]*, [6]**

Terminals using this option 6400, 5055, 11XX, 17XX, 59XX

* [1] is the default for 59XX, 17XX, 11XX. ** [6] is the default for 6400, 5055. Key Click Volume

KeyClick Volume

Numeric, minimum = 0, maximum = 255 [95]

59XX

More (Main Menu 2) Option Note that brackets indicate default settings and values. More (Main Menu 2) Options

Options

[Session 1] Session 2 Session 3 (700 Series, CV60) Session 4 (700 Series, CV60)

Values

Foreground Session

Foreground Sess

None

2415, 2425, 2435A, 2455, 2475, 248X with WTP protocol stack, 6400, 5020, 5055, 11XX, 17XX, 59XX, 700 Series, CK30, CV60

Session Name

Session Name

String, minimum length = 0, maximum length = 64 [null string]

700 Series, CK30, CV60

Set Hot Key

Set Hot Key

F1 through F24, [Disabled]

2415, 2425, 2435A, 2455, 2475, 248X with WTP protocol stack, 6400, 5020, 5055, 11XX, 17XX, 59XX, 700 Series, CK30, CV60

Type-Ahead

Type-Ahead

[Enabled], Disabled

2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 11XX, 17XX, 59XX, 700 Series, CK30, CV60

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

Terminals using this option

235

Page 260

Chapter 5, Customizing Your Configuration

Additional Parameters These parameters do not have equivalent TE 2000 configuration menu options. Note that brackets indicate default settings and values. Additional Parameters

Parameters Alternate Screen Columns

[Session 1] Session 2 Session 3 (700 Series, CV60) Session 4 (700 Series, CV60) Alt Screen Cols

Values Numeric, minimum = 1, maximum = 255 [17]*, [40]**, [16]***

Terminals using this parameter 6400, 5055, 17XX

* [17] is the default for 17XX. ** [40] is the default for 5055. *** [16] is the default for 6400. Alternate Screen Rows

Alt Screen Rows

Numeric, minimum = 1, maximum = 255, [8]*, [12]**, [16]***

6400 Wide Display, 5055, 17XX

* [8] is the default for 17XX. ** [12] is the default for 5055. *** [16] is the default for 6400 Wide Display. Double Byte Character Set (DBCS) Code

DBCS Code

Numeric, minimum = 0, maximum = 16 [0]

59XX

Key Repeat

Key Repeat

Enabled, [Disabled]

59XX

Program Name (appears on initialization and version screens)

Program Name

String, minimum length = 1, maximum length = 8

2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 11XX, 17XX, 59XX, 700 Series, CK30, CV60

Program Version (appears on initialization and version screens)

Program Version

String, minimum length = 1, maximum length = 4

2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 11XX, 17XX, 59XX, 700 Series, CK30, CV60

Return Result

Return Result

[Enabled], Disabled

2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 11XX, 17XX, 59XX, 700 Series, CK30, CV60

This is a test feature for VT/ANSI emulation; if disabled, extended commands (for #K only) does not return a result to the host application. Set-Up Parms Menu Password Password

236

String, minimum length = 1, maximum length = 10 [CR52401]

2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 11XX, 17XX, 59XX, 700 Series, CK30, CV60

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

Page 261

Chapter 5, Customizing Your Configuration

TE_SETTINGS.INI Settings For 700 Series, CK30, CK31, CV60 Terminals with TE 2000 application versions 8.00 or greater, the following settings are available.

Upgrading from CONFIG.DAT Configuration Note that the settings from the CONFIG.DAT file are the same as the settings for the TE_SETTINGS.INI file. For example, the CONFIG.DAT setting: [Host A].Host would appear as session_1|host_a|host = 136.179.84.76 in the TE_SETTINGS.INI file. All values follow the [iccu values] section and use the pipe character to separate the names. The settings and literals are the same as the old CONFIG.DAT with the exception of the use of the different naming convention using the pipe (”|”). Below are a few values from the CONFIG.DAT file as they appear in the TE_SETTINGS.INI file. [iccu values] session_1|host_a|host = 136.179.84.76 session_1|host_a|port_number = 23 session_1|destructive_bs = 0

TE_SETTINGS.INI Configuration “enable_sip“ = 0 or 1

This enables or disables the interaction between the TE 2000 application and the onscreen keyboard. If this value is 1, the TE 2000 application displays the SIP when it starts and when it gains focus. If this value is 0, the TE 2000 application does not display the SIP and it does not toggle the SIP when you click the SIP toggle button. “sip_settings“ = {674EC110-EFF0-47D3-B828-CDB2A6CCD3EB}

This is a GUID (globally unique identifier) that identifies the SIP that the TE 2000 application is to use as its default. This can be the GUID of any registered SIP in the system. These are for debugging purposes only. They inform which version of the TE 2000 application created the TE_SETTINGS.INI file. S program_name = FWP700H0 S program_version = 7.53

TE_SETTINGS.INI Parameter Formats Each parameter in the setup file is followed by one of three different formats that indicates the type of parameter and the values it can contain. Formats are as follows: S Literal strings. List of fixed values to choose from. Session 1 or 2 may qualify Screen Mode. It may take the value Center Cursor, Corner Mode, Page Mode, Lazy Mode, or Locked Mode. Session 1 is the default qualifier. These configuration lines are valid: screen_mode = Lazy Mode; session_1|screen_mode = Lazy Mode; session_2|screen_mode = Lazy Mode;

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

237

Page 262

Chapter 5, Customizing Your Configuration

S Numeric parameters. Numeric parameters have minimum and maximum values. Parameters can be either decimal or hexadecimal: S Decimal parameters consist of digits 0 through 9. S Hexadecimal parameters consist of 0x or 0X, followed by 1 to 4 digits of 0 through 9, a through f, or A through F. These are equivalent: 160, 0xA0, and 0Xa0. Port Number is a variable with a minimum value of 0 and a maximum of 65535. These lines are valid: port_number = 1; session_1|host_a|port_number = 1; session_2|host_a|port_number = 1;

S String parameters. String parameters are variables with minimum and maximum lengths. Program Name is unqualified. It must have eight characters. These configuration lines are valid: program_name = ABCDEFGH; program_name = FWP248H0;

TE_SETTINGS.INI Parameters and Qualifiers Note: If parameters are duplicated, an error is not generated. Instead, the terminal processes the entire file and uses the last entered value of the duplicated parameter. Parameters in the set-up file apply to all model numbers unless otherwise noted here. The following pages list each parameter and its qualifiers. Some qualifiers have default values. If you want to use the default value, you can omit the qualifier from the parameter set-up file. The CFGLIT.DAT file specifies the text of set-up menus or system messages. Parameters and qualifier strings in the set-up file assume you are using the default CFGLIT.DAT file. To customize CFGLIT.DAT, see “Changing Text” on page 252. Note: Only WTP terminals support dual sessions (“Session 2”). For a list of terminals with WTP, see Chapter 1, “Getting Started.”

Set-Up Parameters Options Note that brackets indicate default settings and values. Set-Up Parameters Options

Options

[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values

Terminals using this option

Data Stream host_a|data_stream (default) host_b|data_stream host_c|data_stream

Native (blank if UDP Plus or TCP/IP), 3270, 5250, [VT/ANSI]

700 Series, CK30, CK31, CV60

Host Name host_a|host (default) host_b|host host_C|host

String, minimum = 0, maximum = 16 [null string]

700 Series, CK30, CK31, CV60

238

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

Page 263

Chapter 5, Customizing Your Configuration

Set-Up Parameters Options (continued)

Options

[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values

Terminals using this option

Port Number host_a|port_number (default) host_b|port_number host_c|port_number

Numeric, minimum = 0, maximum = 65535 [23]

700 Series, CK30, CK31, CV60

Radio Number (same as unit number)

host_a|radio_# (default) host_b|radio_# host_c|radio_#

Numeric, minimum = 0, maximum = 127 [127]

700 Series, CK30, CK31, CV60

RTC over TCP host_a|rtc_over_tcp (default) host_b|rtc_over_tcp host_c|rtc_over_tcp

Enabled, [Disabled]

700 Series, CK30, CK31, CV60

Server IP host_a|server_ip (default) host_b|server_ip host_c|server_ip

Numeric, minimum = 1, maximum = 16 [16]

700 Series, CK30, CK31, CV60

SNA sna

Enabled, [Disabled]

700 Series, CK30, CK31, CV60

Telnet telnet

Enabled, [Disabled}

700 Series, CK30, CK31, CV60

Terminal Type host_a|terminal_type (default) host_b|terminal_type host_c|terminal_type

Numeric, minimum = 0, maximum = 255 [255]

700 Series, CK30, CK31, CV60

Unit Number (same as radio number)

host_a|unit_# (default) host_b|unit_# host_c|unit_#

Numeric, minimum = 0, maximum = 127 [127]

700 Series, CK30, CK31, CV60

Bar Code Parameters Note that brackets indicate default settings and values. Bar Code Parameters

Parameters

[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values

BC Type Character bc_type_char

Enabled, [Disabled]

700 Series, CK30, CK31, CV60

Code 39 Encoded code_39_encoded

Enabled, [Disabled]

700 Series, CK30, CK31, CV60

Concatenate concatenate

Enabled, [Disabled]

700 Series, CK30, CK31, CV60

MOD 10 Check mod_10_check

Enabled, [Disabled]

700 Series, CK30, CK31, CV60

ParmsBySession parmsbysession

Enabled, [Disabled]

700 Series, CK30, CK31, CV60

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

Terminals using this parameter

239

Page 264

Chapter 5, Customizing Your Configuration

Bar Code Parameters (continued)

Parameters

[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values

Scan All Fields scan_all_flds

Enabled, [Disabled]

700 Series, CK30, CK31, CV60

Scan Postamble Character scan_postchar

Numeric, minimum = 0, maximum = 255 [0]

700 Series, CK30, CK31, CV60

Scan Preamble Character scan_prechar

Numeric, minimum = 0, maximum = 255 [0]

700 Series, CK30, CK31, CV60

Scanner Type scanner_type

[No Scanner], Wand, Laser, Wand Emulate, Auto Detect

700 Series, CK30, CK31, CV60

Stream Scan stream_scan

Enabled, [Disabled]

700 Series, CK30, CK31, CV60

Use Wedge Mode use_wedge_mode

[Enabled], Disabled

700 Series, CK30, CK31, CV60

Terminals using this parameter

Bar Code Symbologies Note that brackets indicate default settings and values. Bar Code Symbologies

Symbologies

[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values

ABC Codabar abc_codabar

Scanner_type = 33

700 Series, CK30, CK31, CV60

Codabar codabar

Scanner_type = 32

700 Series, CK30, CK31, CV60

Code 11 code_11

Scanner_type = 56

700 Series, CK30, CK31, CV60

Code 39 code_39

Scanner_type = 40

700 Series, CK30, CK31, CV60

Code 93 code_93

Scanner_type = 72

700 Series, CK30, CK31, CV60

Code 128 code_128

Scanner_type = 64

700 Series, CK30, CK31, CV60

Computer Identics 2 of 5 ci_2of5

Scanner_type = 50

700 Series, CK30, CK31, CV60

EAN ean

Scanner_type = 17

700 Series, CK30, CK31, CV60

Interleaved 2 of 5 int_2of5

Scanner_type = 51

700 Series, CK30, CK31, CV60

Plessey plessey

Scanner_type = 8

700 Series, CK30, CK31, CV60

240

Terminals using this symbology

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

Page 265

Chapter 5, Customizing Your Configuration

Bar Code Symbologies (continued)

Symbologies

[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values

Straight 2 of 5 str_2of5

Scanner_type = 49

700 Series, CK30, CK31, CV60

UPC upc

Scanner_type = 16

700 Series, CK30, CK31, CV60

Terminals using this symbology

Generic Bar Code Options Note that brackets indicate default settings and values. Note: Generic bar code options must be qualified by one of the bar code symbology strings. For example: “session_1|upc|max_length = 13;” Generic Bar Code Options

Options

[Session 1] Session 2 Session 3 (700 Series, CK30, CK31, CV60) Session 4 (700 Series, CK30, CK31, CV60) Values

Terminals using this option

Drop Leading upc|drop_leading ean|drop_leading code_128|drop_leading code_39|drop_leading codabar|drop_leading abc_codabar|drop_leading str_2of5|drop_leading int_2of5|drop_leading ci_2of5|drop_leading code_11|drop_leading code_93|drop_leading plessey|prop_leading

Numeric, minimum = 0, maximum = 15 [0]

700 Series, CK30, CK31, CV60

Drop Trailing upc|drop_trailing ean|drop_trailing code_128|drop_trailing code_39|drop_trailing codabar|drop_trailing abc_codabar|drop_trailing str_2of5|drop_trailing int_2of5|drop_trailing ci_2of5|drop_trailing code_11|drop_trailing code_93|drop_trailing plessey|drop_trailing

Numeric, minimum = 0, maximum = 15 [0]

700 Series, CK30, CK31, CV60

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide