The text of a manual · part 9 of 18
TRAKKER Antares Terminal Emulation User's Guide, pages 81 to 90
Pages 81 to 90 of 176
The original document is the PDF (989 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2425, Intermec 2480, Intermec 2486, Intermec 2481 and Intermec 2485
Page 81
Co de 39NG Customizing Your Configuration
3
Or follow this procedure: 1. At the TE welcome screen or anywhere in a TE session, press TE Configuration menu. TE welcome screen to access the
TE session screen
* Intermec TRAKKER Antares VT/ANSI Terminal Emulation Version 04.1
<login:
TE24XXUG.029
Note: If you are not connected to the host or DCS 300 or controller or have problems accessing the TE Configuration menu, reset your firmware to get to the TE welcome screen. For help, see Chapter 6, “Troubleshooting.” The Terminal Emulation menu appears.
TERMINAL
EMULATION
Configure TE Set Password Exit TE Configure TE
_` Select item [Enter] Next [F1] Help [Esc] Exit TE24XXUG.004
Note: If the Terminal Emulation menu does not appear, you need to reset the terminal firmware for the TE keypad or keyboard. For help resetting the keypad or keyboard, see “Problems Accessing the TE Configuration Menu” in Chapter 6.
3-29
Page 82
TRAKKER Antares Terminal Emulation User’s Guide Co de 39NG
2. Press
: or V to highlight Exit TE and press The Exit Menu screen appears. EXIT
MENU
TO EXIT Select OK. To Return to Main Menu Select CANCEL.
OK
CANCEL TE24XXUG.026
Note: If you changed the TE configuration without saving the changes, those changes will be lost if you restart the application. To save your configuration changes, see “Exiting the TE Configuration Menu” earlier in this chapter. 3. Select OK and press
The Restarting Terminal Emulation screen appears.
COMMUNICATIONS Restarting Terminal Emulation. Please
Wait.
TE24XXUG.028
4. Wait a few seconds while the screen clears and the application starts. The terminal restarts your TE application using the configuration saved in the TE configuration file. Once the screen on the terminal shows the sign-on or login screen, you can either start using the application or change the TE configuration.
3-30
Page 83
Co de 39NG Customizing Your Configuration
3
Using the Auto-Login Feature The auto-login feature allows you to send the same login information each time you login to the host. When you start the TE application, the terminal checks for an autologin script file. The script file, AUTOLOG.SCR, must be stored in the same directory where the TE application is stored. If there is a script file, the terminal runs the login commands from the auto-login script file. To use the auto-login feature, you need to: 1. Develop an auto-login script file. 2. Load the auto-login script file on the terminal. These steps are covered in the next sections along with a list of the necessary control characters and the procedure for disabling the auto-login feature.
Developing Auto-Login Script Files A typical auto-login script file consists of a few Input and InputHidden commands followed by a HostName command, followed by a series of WaitFor and Send commands. A very simple script file may not have any input commands if all of the TRAKKER Antares terminals are using the same account. There are six commands you can use to create auto-login script files. All commands are case sensitive. For example, WaitFor is a command, but Waitfor is not a valid command. “Sample Auto-Login Script Files” in Appendix A provides examples of script files. The auto-login script commands are defined next: Input Input is called with two parameters. The first parameter is a character string enclosed in quotes that is used as a prompt to the user. The second parameter is a string variable name indicating where the text string will be stored. InputHidden Same as the Input script command except that user input is echoed as a string of asterisks. HostName HostName is followed by a character string enclosed in quotes. The character string can be a host name or an asterisk. The host name command acts as an IF clause. If the host name matches, the following section of the script file is executed up to the next host name command. If an asterisk is used, it matches any host name. WaitFor Wait for a list of up to 10 strings. The strings must be enclosed in quotes and must be separated by a comma. The strings cannot exceed 20 characters in length.
3-31
Page 84
TRAKKER Antares Terminal Emulation User’s Guide Co de 39NG
Send This command sends a character string enclosed in quotes or a string variable to the host. The character string enclosed in quotes can have an embedded control key in VT/ANSI emulation and embedded IBM mnemonics in 3270 and 5250 emulation.
PromptSessionStart PromptSessionStart is a predefined variable. If this variable is defined and set to any value other than 0, the application prompts the user to press before starting a Telnet session with the host.
Control Characters for Auto-Login Script Files You can include control characters in your auto-login script file. The control character must be enclosed by < > (angle brackets) in the AUTOLOG.SCR file. Note: For VT/ANSI terminal emulation, you can also use the corresponding hexadecimal value to represent the control character. For a description of control characters and their hexadecimal equivalents, see the “Full ASCII Table” in your TRAKKER Antares user’s manual.
3270 and 5250 Control Characters Control Character
Definition
Control Character
Definition
Control Character
Definition
<ATTN>
Attention
<RTAB>
Right Tab
<F12>
Function Key
<CLEAR>
Clear
<SPACE>
Space
<F13>
Function Key
<CUR_DN>
Cursor Down
<F1>
Function Key
<F14>
Function Key
<CUR_LF>
Cursor Left
<F2>
Function Key
<F15>
Function Key
<CUR_RT>
Cursor Right
<F3>
Function Key
<F16>
Function Key
<CUR_UP>
Cursor Up
<F4>
Function Key
<F17>
Function Key
<DEL>
Delete
<F5>
Function Key
<F18>
Function Key
<ERS_EOF>
Erase EOF
<F6>
Function Key
<F19>
Function Key
<HOME>
Home
<F7>
Function Key
<F20>
Function Key
<INS>
Insert
<F8>
Function Key
<F21>
Function Key
<LTAB>
Left Tab
<F9>
Function Key
<F22>
Function Key
<NEWLN>
New Line
<F10>
Function Key
<F23>
Function Key
<RESET>
Reset
<F11>
Function Key
<F24>
Function Key
3-32
Page 85
Co de 39NG Customizing Your Configuration
3
VT/ANSI Control Characters Control Character
Definition
Control Character
Definition
Control Character
Definition
<ACK>
Acknowledgment
<ENQ>
Enquiry
<NUL>
Null, or all zeroes
<BEL>
Bell
<EOT>
End of Transmission
<RS>
Record Separator
<BS>
Backspace
<ESC>
Escape
<SI>
Shift In
<CAN>
Cancel
<ETB>
End Transmission Block
<SO>
Shift Out
<CR>
Carriage Return
<ETX>
End of Text
<SOH>
Start of Heading
<DC1>
Device Control 1 (XON)
<FF>
Form Feed
<STX>
Start of Text
<DC2>
Device Control 2
<FS>
File Separator
<SUB>
Substitute
<DC3>
Device Control 3 (XOFF)
<GS>
Group Separator
<SYN>
Synchronous Idle
<DC4>
Device Control
<HT>
Horizontal Tab
<US>
Unit Separator
<DLE>
Data Link Escape
<LF>
Line Feed
<VT>
Vertical Tab
<EM>
End of Medium
<NAK>
Negative Acknowledge
Loading the Auto-Login Script File Here’s a summary of the steps you follow to download an auto-login script file to the TRAKKER Antares terminals. You can download more than one script file, but name the file that you want to use immediately as AUTOLOG.SCR and name any other script files with different names ending with .SCR. To learn more about transferring files, see your TRAKKER Antares user’s manual. To use the serial port to download an auto-login script file 1. Create your auto-login script file using any text editor or copy and modify one of the example script files in Appendix A. 2. Save the file you create as AUTOLOG.SCR. 3. Connect the terminal to the development PC or host using the optical link adapter or TD2400 communications dock. For help, see your TRAKKER Antares user’s manual or your accessory documentation. 4. Use the FileCopy utility to download the AUTOLOG.SCR file to the terminal. You must load the AUTOLOG.SCR file into drive C, the same directory where the TE application is stored.
3-33
Page 86
TRAKKER Antares Terminal Emulation User’s Guide Co de 39NG
To use RF communications to download an auto-login script file 1. Create your auto-login file using any text editor or copy and modify one of the example script files in Appendix A. 2. Save the file you create as AUTOLOG.SCR. 3. Copy the AUTOLOG.SCR file to the DCS 300 or Model 200 Controller, or copy the AUTOLOG.SCR file to a host in a TCP/IP direct connect network. 4. In a UDP Plus network, use the Download Server option on the DCS 300 or controller to download the file to the terminal. In a TCP/IP direct connect network, use your TFTP application to download the file to the terminal. When you reset your TRAKKER Antares terminal, the terminal clears the auto-login information, such as the password and user’s name. You can cancel the auto-login process by pressing any key during the auto-login sequence. When a host session is broken, you can restart the auto-login sequence by pressing , the Auto-Login Restart command. For more information on the Auto-Login Restart command, see Chapter 4, “3270 and 5250 Commands,” or Chapter 5, “VT100/220/320 and ANSI Commands.”
Note: Auto-login information is saved when you end a TE session by logging off from the host computer. This DOES NOT prevent another user from establishing a TE session using your login information. You must use Exit TE to clear auto-login information.
Disabling the Auto-Login Feature To disable the auto-login feature, you must rename the AUTOLOG.SCR file. Renaming AUTOLOG.SCR forces your TE application to use the default login. Renaming also ensures that you can use the same auto-login script file later by changing the name back to AUTOLOG.SCR. If you want to enable a new script file, you can use the instructions in this section to rename a different script file to AUTOLOG.SCR. To disable the auto-login script file
T3 ,
1. Press or scan this bar code to access the TRAKKER Antares 2400 Menu System. The Main Menu appears. Enter Test and Service Mode
*..-.* *..-.*
2. Choose System Menu and then choose File Manager. 3. Select drive C.
3-34
Page 87
Co de 39NG Customizing Your Configuration
4. Press
: or V to highlight AUTOLOG.SCR and press
3
5. Type the new name for the auto-login script file and press or choose OK.
6. Exit the TRAKKER Antares 2400 Menu System to return to your current TE session. Restart your TE application to use TE without the auto-login feature. You can also rename the auto-login script file from your host or by scanning bar codes. For help, see your TRAKKER Antares user’s manual to rename the file using these methods.
Configuring Terminal Emulation to Display International Characters With a TRAKKER Antares terminal running firmware version 2.20 or higher and TE applications version 4.0 or higher, you can configure your terminal to display international characters. You need to load a language mapping file on the terminal to begin displaying international characters in your TE application. The language mapping file must be loaded on the terminal’s drive C and named DISPTBLS.MAP. The TE international mapping files are available on the DCS 300 or Model 200 Controller (version 3.0 and higher) or in the TRAKKER Antares firmware upgrade kit for version 2.20 and higher. On the DCS 300 or Model 200 Controller (version 3.0 and higher), international mapping files for 3270 and 5250 TE are stored in the USERDATA\TERMAPPS\ IBMTE directory. International mapping files for VT/ANSI TE are stored in the USERDATA\TERMAPPS\VTTE directory. For the TRAKKER Antares firmware upgrade kit (version 2.20 and higher), the international mapping files are available on a separate disk. For help finding the files, see the README text that comes with the upgrade kit. For help ordering an upgrade kit, see your local Intermec sales representative. The following procedures explain how to download and rename an international mapping file. To download an international mapping file 1. Decide which language you want to display and find the corresponding mapping file. For a list of the file names, see the tables later in this section. 2. Connect the terminal to your PC, DCS 300, or Model 200 Controller. To download the mapping file using the serial port, connect the terminal to the PC or host using the optical link adapter or TD2400 communications dock. For help, see your TRAKKER Antares user’s manual or your accessory documentation.
3-35
Page 88
TRAKKER Antares Terminal Emulation User’s Guide Co de 39NG
3. Download the file to drive C using one of these methods: •
FileCopy utility on your PC
•
Download Server option on the DCS 300 or controller
•
An application on the host
For help downloading the file, see your TRAKKER Antares user’s manual. To rename an international mapping file
T3 ,
1. Press or scan this bar code to access the TRAKKER Antares 2400 Menu System. The Main Menu appears. Enter Test and Service Mode
*..-.* *..-.*
2. Choose System Menu and then choose File Manager. 3. Select drive C.
: or V to highlight the mapping file and press 5. Type DISPTBLS.MAP and press or choose OK.
4. Press
6. Exit the TRAKKER Antares 2400 Menu System to return to your current TE session. Restart your TE application to display the new language.
3270 and 5250 TE International Mapping Files
3-36
Language
File
Other Language
U.S. English
037-850.MAP
German
273-850.MAP
Norwegian
277-850.MAP
Danish
Swedish
278-850.MAP
Finnish
Italian
280-850.MAP
Spanish
284-850.MAP
French
297-850.MAP
Portuguese
500-850.MAP
Belgian
Page 89
Co de 39NG Customizing Your Configuration
3
VT/ANSI TE International Mapping Files Character Set
File
ISO8859-1
ISO1-850.MAP
DEC Multinational
DEC-850.MAP
To use a custom translation table for VT/ANSI terminal emulation, rename ISO1850.MAP (for UNIX hosts) or DEC-850.MAP (for DEC/VAX hosts) as DISPTBLS.MAP and download it to the TRAKKER Antares terminal. You can use either RF communications or the serial port to download your new DISPTBLS.MAP file.
3-37