Page 71
Co de 39NG Customizing Your Configuration
3
Modifying the TE Configuration File Once you have uploaded the TE configuration file, you can use any text editor to modify the TE parameters. To modify the TE configuration file 1. Using any text editor, change the TE parameters. To find the TE parameters and options you want to change, use the next two sections: •
3270 or 5250 TE Configuration File Parameters
•
VT/ANSI TE Configuration File Parameters
For example, if you want to change the text size from regular height to double height, find the following line in the TE3270.CFG, TE5250.CFG, or TEANT.CFG file: TextSize=RegularHeight
Change the line to read: TextSize=DoubleHeight
2. For FileCopy versions earlier than 3.0, remove everything, including blank space, at the end of the TE configuration file up to the last readable line of code. Earlier versions of FileCopy fill in the last data block with Ctrl Z, and if you download the TE configuration file with this fill-in character in it, the file will not run. For example, you might see and need to delete the following at the end of the TE configuration file: ❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚❚ 3. Save the TE3270.CFG, TE5250.CFG, or TEANT.CFG file. 4. Download the TE3270.CFG, TE5250.CFG, or TEANT.CFG file to drive C on your terminal. For help, see “Downloading the TE Configuration File” later in this section.
3270 or 5250 TE Configuration File Parameters The following table explains the parameters you can set for 3270 or 5250 TE and lists what to look for in the TE configuration file to modify the parameter. The default settings will be shown in the TE configuration file (TE3270.CFG or TE5250.CFG) when you upload it.
3-19
Page 72
TRAKKER Antares Terminal Emulation User’s Guide Co de 39NG
3270 and 5250 TE Configuration File Parameters Parameter
Name in the TE Configuration File
Parameter Options
Text Size
TextSize
RegularHeight DoubleHeight
Selects the size of text the terminal displays on the terminal screen. Options are regular height (normal characters) and double height (double high text).
Auto Field Advance (5250 only)
AutoAdvance
Enable Disable
Enables or disables the auto field advance option. Auto field advance enabled is the default. For more information about using autoadvance, see “Auto-Advancing Through Fields on 5250 Terminal Emulation Screens” in Chapter 2.
Upline Protocol (UDP Plus only)
TranId
$TE3, $TE5, $TEV,
Select either Telnet ($TEV,) or SNA ($TE3, for 3270, or $TE5, for 5250) protocol. SNA forces the TRAKKER Antares terminal to use the SNA 3270 or 5250 Terminal Session Manager (TSM) on the DCS 300 or Model 200 Controller for communicating with the host. Telnet forces the terminal to use the Telnet TSM in the DCS 300 or controller to communicate with the host. Both TSM components reside on the DCS 300 or controller and are transparent to the terminal emulation user.
3-20
Description
Page 73
Co de 39NG Customizing Your Configuration
3
3270 and 5250 TE Configuration File Parameters (continued) Parameter Host Name (UDP Plus only)
Name in the TE Configuration File
Parameter Options
HostName
(blank)
Description Enter the name of the host to which you want the terminal to connect. You can enter a host name that is up to 15 characters long. The name must match a host name in the list of available hosts defined on the DCS 300 or Model 200 Controller. Note: If you have linked a terminal with a host name on the DCS 300 or Model 200 Controller, you do not need to enter a host name in this screen. If you have not linked a terminal with a host name on the DCS 300 or controller, you must enter a host name for this parameter.
Viewport Mode
ViewportMode
Follow Center Manual
Select one of these viewport movement modes: •
Follow Enables viewport Follow Cursor mode.
•
Center Enables viewport Center mode. The viewport always centers around the cursor.
•
Manual Disables viewport movement. You must manually move the cursor to each field in the screen.
Side Boundary (Follow Cursor Mode only)
SideBoundary
1
Set this parameter to a value from 1 to 10. The viewport moves when the cursor is this number of characters (1 to 10) from the right or left side boundary.
Side Jump (Follow Cursor Mode only)
SideJump
10
Set this parameter to a value from 1 to 10. The number of characters (1 to 10) the viewport moves right or left when you reach a horizontal boundary.
3-21
Page 74
TRAKKER Antares Terminal Emulation User’s Guide Co de 39NG
3270 and 5250 TE Configuration File Parameters (continued) Name in the TE Configuration File
Parameter Options
Vertical Boundary (Follow Cursor Mode only)
VerticalBoundary
1
Set this parameter to a value from 1 to 10. The viewport moves when the cursor is this number of characters (1 to 10) from the top or bottom boundary.
Vertical Jump (Follow Cursor Mode only)
VerticalJump
8
Set this parameter to a value from 1 to 10. The number of characters (1 to 10) the terminal moves up or down when you reach a vertical boundary.
Parameter
Description
VT/ANSI TE Configuration File Parameters The following table explains the parameters you can set for VT/ANSI TE and lists what to look for in the TE configuration file to modify the parameter. The default settings will be shown in the TE configuration file (TEANT.CFG) when you upload it.
VT/ANSI TE Configuration File Parameters Parameter
Name in the TE Configuration File
Parameter Options
Text Size
TextSize
RegularHeight DoubleHeight
Selects the size of text the terminal displays on the terminal screen. Options are regular height (normal characters) and double height (double high text).
Terminal Type
TermType
VT100 VT220 VT320 ANSI RDRANSI
Selects the terminal type of the host system. The supported terminal types are VT100, VT220, VT320, RDRANSI, and ANSI.
Terminal Mode (VT220/320 only)
TermMode
VT100 VT220-7bit VT220-8bit VT320-7bit VT320-8bit
Select the Terminal mode that corresponds to your terminal type. This field sets the mode VT-series terminals use to exchange escape sequences, control commands, and status reports with an application.
3-22
Description
Page 75
Co de 39NG Customizing Your Configuration
3
VT/ANSI TE Configuration File Parameters (continued) Name in the TE Configuration File
Parameter Options
User-Defined Key (VT220/320 only)
UserDefinedKey
Unlock Lock
Select whether you want this parameter set to lock or unlock. When you select lock, you cannot reprogram user-defined keys. When you select unlock, you can program user-defined keys from the host application.
Keypad Mode
KeypadMode
Numeric Application
Select Numeric or Application mode. These options generate different key codes. For a list of key codes, see “Understanding VT/ANSI Key Support” in Appendix B.
Parameter
Description
If you select Numeric mode, you generate ANSI cursor control ESC sequences that correspond to what appears on the face of the keys. If you select Application mode, you generate application ESC sequences for the key code. For help, see your VT manual. Cursor Mode
CursorMode
Cursor Application
Select Cursor or Application mode. These two options generate different key codes. If you select Cursor mode, you generate ANSI cursor control ESC sequences that correspond to what appears on the face of the cursor key. If you select Application mode, you generate application ESC sequences for the key code. For help, see your VT manual.
3-23
Page 76
TRAKKER Antares Terminal Emulation User’s Guide Co de 39NG
VT/ANSI TE Configuration File Parameters (continued) Parameter
Name in the TE Configuration File
Parameter Options
Numeric Keypad
NumericKeypad
Disable Enable
Enables or disables Numeric Keypad mode on the terminal. When you enable Numeric Keypad mode, the terminal numeric keys function like the numeric keys on a PC’s numeric keypad. When you disable Numeric Keypad mode, the terminal numeric keys function like the numeric keys on the main section of a PC keyboard.
Input Mode
InputMode
CharMode LineMode
Select Line mode or Character mode. In Line mode, you can enter a line of characters on your terminal before transmitting data to the host. Press to send each line of text. Line mode reduces communications overhead because input is sent one line at a time instead of one or a few characters at a time. In Character mode, keypad or keyboard input is immediately sent to the host.
Description
Answerback
Answerback
(blank)
When the host computer sends an ENQ, the terminal responds by sending the Answerback field to the host. You can also press on the terminal to send the Answerback field to the host. Answerback can be up to 30 characters long including any ASCII character from 0 to 255. You can place a carriage return anywhere in the Answerback field. Enter these four characters for a carriage return: <cr>.
9
3-24
Page 77
Co de 39NG Customizing Your Configuration
3
VT/ANSI TE Configuration File Parameters (continued) Parameter Host Name (UDP Plus only)
Name in the TE Configuration File
Parameter Options
HostName
(blank)
Description Enter the name of the host to which you want the terminal to connect. You can enter a host name that is up to 15 characters long. The name must match a host name in the list of available hosts defined on the DCS 300 or Model 200 Controller. Note: If you have linked a terminal with a host name on the DCS 300 or Model 200 Controller, you do not need to enter a host name in this screen. If you have not linked a terminal with a host name on the DCS 300 or controller, you must enter a host name for this parameter.
Viewport Mode
ViewportMode
Follow Center Manual
Select one of these viewport movement modes: •
Follow Enables viewport Follow Cursor mode.
•
Center Enables viewport Center mode. The viewport always centers around the cursor.
•
Manual Disables viewport movement. You must manually move the cursor to each field in the screen.
Side Boundary (Follow Cursor Mode only)
SideBoundary
1
Set this parameter to a value from 1 to 10. The viewport moves when the cursor is this number of characters (1 to 10) from the right or left side boundary.
Side Jump (Follow Cursor Mode only)
SideJump
10
Set this parameter to a value from 1 to 10. The number of characters (1 to 10) the viewport moves right or left when you reach a horizontal boundary.
3-25
Page 78
TRAKKER Antares Terminal Emulation User’s Guide Co de 39NG
VT/ANSI TE Configuration File Parameters (continued) Name in the TE Configuration File
Parameter Options
Vertical Boundary (Follow Cursor Mode only)
VerticalBoundary
1
Set this parameter to a value from 1 to 10. The viewport moves when the cursor is this number of characters (1 to 10) from the top or bottom boundary.
Vertical Jump (Follow Cursor Mode only)
VerticalJump
8
Set this parameter to a value from 1 to 10. The number of characters (1 to 10) the terminal moves up or down when you reach a vertical boundary.
Printer Ready
PrinterReady
No Yes
Printer ready means the printer is on and connected to your terminal.
Auto Print Mode
AutoPrintMode
Off On
Prints each line after the cursor leaves that line using a carriage return or when auto-advancing through fields. This mode can be turned on or off from a VT/ANSI host or in the TE configuration file.
Printer Controller
PrinterController Mode
Off On
Prints all data from a VT/ANSI host. This mode should be turned on and off from the host because all host screens are printed without allowing the user to respond. You cannot log on or off while in this mode.
Print Form Feed
PrintFormFeedMode
Off On
After a screen is printed, the printer advances the printed screen out of the printer.
Parameter
3-26
Description
Page 79
Co de 39NG Customizing Your Configuration
3
Downloading the TE Configuration File You can use three different methods to download the TE configuration file: •
FileCopy through a serial connection from your T2480 or T2485 to your PC
•
The Download Server feature on the DCS 300 or controller to a T2480 or T2485 loaded with UDP Plus protocol
•
The TFTP application on a PC or host to a T2480 or T2485 loaded with TCP/IP protocol
This section covers the first two methods. To use the TFTP application, see the TRAKKER Antares 248X Stationary Terminal User’s Manual. To use FileCopy to download the TE configuration file 1. Connect the T2480 or T2485 to a PC using COM1, COM2, or COM4 on the back of the T2480 or T2485. For help, see the terminal user’s manual. 2. Use FileCopy to download the TE configuration file from your PC to the terminal’s drive C. For help using FileCopy, use the online Help. To use the Download Server to upload the TE configuration file 1. Configure your T2480 with Ethernet or your T2485 to communicate with the DCS 300 or Model 200 Controller. For help, see the terminal user’s manual. 2. Using the Download Server feature on the DCS 300 or controller, select the T2480 or T2485 that you want to download the TE configuration file to. You can also select a group of terminals. For help, see the DCS 300 System Manual or Model 200 Controller System Manual. 3. Choose the Command option button. 4. Enter the Receive File reader command and choose Add. The command appears in the Files and Data box. .%R,fromfilename,c:tofilename
For example, to upload the TE configuration file for VT/ANSI, enter the following command: .%R,teant.cfg,c:teant.cfg
5. Choose OK to save the Receive File reader command and return to Terminal Download Configuration dialog box. 6. Choose Download to download the Receive File reader command to the T2480 or T2485. The T2480 or T2485 will download the TE configuration file to the terminal’s drive C. If you already have a TE session running and you changed TE communications parameters, you must restart your TE application for the changes to take effect.
3-27
Page 80
TRAKKER Antares Terminal Emulation User’s Guide Co de 39NG
To restart your TE application •
Scan this bar code label Reset Firmware
*-.* *-.*
You can also send the Reset Firmware command over the network. For help, see your TRAKKER Antares terminal user’s manual. Or, use the TRAKKER Antares 2400 Menu System to configure the Resume Execution command to resume “not allowed.” Choose Terminal Menu from the Configuration Menu and then choose Power Management. Each time you press to turn on the terminal, the terminal boots and restarts your application.
f
The terminal restarts your TE application using the configuration saved in the TE configuration file.
Restarting Terminal Emulation You will need to restart your TE application if you are having problems or if you want to reconnect to the host with a new configuration. Restarting your TE application will also clear the auto-login information, preventing another user from establishing a TE session using your login information. You can restart your TE application by either scanning Reset Firmware or by using the Exit TE option in the TE Configuration menu. Both methods reset all terminal firmware and the application and run the application in a new session. To restart TE Scan this bar code label: Reset Firmware
*-.* *-.*
The terminal restarts your TE application using the configuration saved in the TE configuration file.
3-28