Page 41

HelvC NugFont

Co d e 39 Getting Started

{

3. Press to choose the Set Time and Date command and then press The Time and Date screen appears.

1 ;.

TIME AND DATE Current time is 11:37:03 New time: 12:39:00 Current date is 96/01/12 New date (YY/MM/DD):

OK

CANCEL 242XU.009

{

4. Type the current time in the format HH MM SS with a space character between each field and then press . The program fills in the colon character in the time field. For example, to enter the time 08:05:03, type:

08:05:03 {

Note: The time is not actually updated until you exit the Time and Date screen. When you set the time, set the time ahead so that the correct time is saved when you exit the screen in Step 6.

{

5. Type the current date in the format YY MM DD with a space character between each field and then press . The program fills in the slash character in the date field. For example, to enter the date August 9, 1996, type:

96:08:09 { 6. Press ; to save the changes and exit the Time and Date screen. 7. Press d to exit the System Menu. The Main Menu appears. Continue with the next procedure to set the required network parameters.

1-19

Page 42

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Setting the Network Parameters In this procedure, you activate network communications and set your controller and terminal IP addresses. You also need to set the RF domain and RF security identification password. For a detailed definition of these parameters, see Chapter 4, “Operating the Terminal in a Network.” To set the network parameters

{

1. Press to choose the Configuration Menu and then press Configuration Menu appears.

;. The

)yT 2 M

Note: If you are not in the TRAKKER 2400 Menu System, press to access the Main Menu.

CONFIGURATION MENU Symbologies Menu Communications Menu Terminal Menu

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.010

{

2. Press to choose the Communications Menu and then press Communications Menu appears.

1-20

;. The

Page 43

HelvC NugFont

Co d e 39 Getting Started

1

Communications Menu COMMUNICATIONS

MENU

Primary Network Advanced Network RF Driver

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.011

;

3. Press to choose the Primary Network command. The Primary Network screen appears. PRIMARY

NETWORK

Activate: Disabled Controller IP Addr: 0.0.0.0 Terminal IP Address: 0.0.0.0

OK

CANCEL 242XU.012

}

4. In the Activate field, press to toggle the field and display the 2.4 GHz RF option and activate radio frequency network communications. Press to move to the next field.

{

5. In the Controller IP Address field, type in the IP address for the Model 200 Controller in your network.

1-21

Page 44

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

The address field consists of four separate numbers. Each number in the field is separated by a period and can be a number from 0 to 255. Type the address in the format nnn.nnn.nnn.nnn and then press .

{

For example, if your Controller IP address is 192.100.100.2, type:

192.100.100.2

Note: The network cannot be activated if the first address segment in the IP address is set to 0, 127, or a number greater than 223. 6. In the Terminal IP Address field, type in the terminal’s IP address. The IP address must match the address set on the controller. The address field consists of four separate numbers. Each number in the field is separated by a period and can be a number from 0 to 255. Type the address in the format nnn.nnn.nnn.nnn and then press .

{

For example, if your Terminal IP address is 192.100.100.3, type:

192.100 .100.3

Note: The network cannot be activated if the first address segment in the IP address is set to 0, 127, or a number greater than 223.

; to save the changes and exit the Primary Network screen. 8. Press { twice to choose the RF Driver command and then press ;.

7. Press

The RF Driver screen appears. RF

DRIVER

Domain: 00 Security ID: (ID unchanged) Wakeup on Broadcast: No

OK

CANCEL 242XU.013

1-22

Page 45

HelvC NugFont

Co d e 39 Getting Started

9. In the Domain field, type a number from 0 to 15 and then press domain must match the number set on the access points.

1 {. The

{

10. In the Security ID field, type the RF security identification password and then press . The password can be up to 20 characters long and must match the security ID set on the access points. Note: If you have not changed the Security ID in the current session, the words, (ID unchanged), display instead of the actual password. If you change the Security ID, you see the actual password until you save the changes. 11. Press

; to save the changes and exit the RF Driver screen.

Note: If the terminal is on a different IP subnetwork from the Model 200 Controller, you must also configure the default router and subnet mask. Choose the Advanced Networks command to set these parameters. For help, see Chapter 4, “Operating the Terminal in a Network.” d 13. Press d to exit the Configuration Menu. 14. Press ; to choose Yes and save the new configuration in RAM. Once 12. Press to exit the Communications Menu. The Configuration Menu appears.

the changes are saved, the terminal uses the new configuration.

Save new configuration (in

RAM)?

Yes

No

CANCEL

242XU.059

15. Press d to exit the TRAKKER 2400 Menu System. 1-23

Page 46

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

;

16. Press to choose Yes and store your changes permanently in flash memory.

Store changes in flash memory? (used when rebooting the terminal)

Yes

No

CANCEL

242XU.054

;

17. Press to choose OK and exit the TRAKKER 2400 Menu System. Continue with the next procedure to start your application.

Exiting TRAKKER Menu

OK

2400

System

CANCEL 242XU.055

1-24

Page 47

HelvC NugFont

Co d e 39 Getting Started

1

Starting the Application Your terminal has been configured and loaded with only one of these applications: • 3270 and 5250 screen mapping • IBM 3270 terminal emulation • IBM 5250 terminal emulation • VT100/220/320 and ANSI terminal emulation To start the application 1. After you exit the TRAKKER 2400 Menu System, this warning screen appears again.

*** WARNING *** TE configuration file not found. Press a key and a default one will be created.

242XU.129

2. Press

; to continue.

An introduction screen appears for your application followed by a series of messages. The terminal will try to establish communications with the Model 200 Controller and the host computer. Once the terminal connects, you see the message: Connected to Host. Note: While the terminal is connecting to the controller, the terminal ignores any input from the keypad or scanner. Wait until the terminal is connected before you try to enter any data.

1-25

Page 48

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

The login or initial screen for each application appears. You can begin using the terminal to collect data.

3270/5250 Sign On Screen

VTXXX/ANSI Login Screen

*

*

Sign on User.............. Password.......... Program/procedure. Menu.............. Current Library...

* File

<login:

TNAPP TNAPP

Screen Mapping Screen

TNAPP

Name:

F

F

F 242XU.014

If the terminal will not connect, see Chapter 6, “Troubleshooting” or the Model 200 Controller System Manual.

Verifying That the Terminal Is Operating Correctly Once you have configured the terminal, your TRAKKER 2425 terminal is ready for operation. To verify that the Network Activate command is enabled and the radio is working 1. If the terminal is not on, press q to turn it on.

2. Look at the top line of the terminal’s display. If the Radio icon does not appear, the Network Activate command is enabled and the radio is working. You may see other icons on the display. If the Radio icon (shown in the illustration) remains on solid, the Network Activate command is disabled, or there is a problem with the radio card and the radio is turned off.

242XU.116

1-26

Page 49

Co d e 39 Getting Started

HelvC NugFont

1

Make sure the Network Activate command is enabled. For help, see “Configuring the Terminal” earlier in this chapter. If the network is activated and the Radio icon still appears, there may be a problem with the radio. For help, contact your local Intermec service representative. To verify that the terminal is communicating with the 0100 Access Point 1. If the terminal is not on, press q to turn it on.

2. Look at the top line of the terminal’s display. If the Connect icon blinks (shown in the illustration) or remains on solid, the terminal is communicating with the access point and is trying to establish communications with the controller. The terminal can send and receive data to the access point.

* 242XU.128

If the Connect icon is not blinking or is not on, you need to check the network configuration. For help, see “Configuring the Controller and Access Point” or “Configuring the Terminal” earlier in this chapter.

To verify that the terminal is communicating with the Model 200 Controller 1. If the terminal is not on, press q to turn it on.

2. Look at the top line of the terminal’s display. If the Connect icon (shown in the illustration) appears and remains on solid, the terminal is communicating with the controller. The terminal can send and receive data to the access point and controller.

* 242XU.109

1-27

Page 50

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

If the Connect icon blinks or is not on, you need to check the network configuration. For help, see “Configuring the Controller and Access Point” or “Configuring the Terminal” earlier in this chapter. Note: The Connect icon is not instantaneously updated but does tell you the communications status the last time data was sent or received from the terminal. To verify that the application is running q

1. If the terminal is not on, press to turn it on. The login or initial screen for your application should appear.

3270/5250 Sign On Screen

VTXXX/ANSI Login Screen

* Sign on User.............. Password.......... Program/procedure. Menu.............. Current Library...

*

F

* File

<login:

TNAPP TNAPP

Screen Mapping Screen

F

TNAPP

Name:

F 242XU.014

2. Use the keypad to type data in a field, or use the scan module to scan bar code labels. To learn more about using the terminal’s keypad and display, see Chapter 2, “Learning How to Use the Terminal.”

1-28