The text of a manual · part 4 of 46
TRAKKER Antares 2425 Hand-Held Terminal User's Manual, pages 31 to 40
Pages 31 to 40 of 452
The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2425
Page 31
HelvC NugFont
Co d e 39 Getting Started
1
Installing the Main Battery Pack Next, install the fully charged main (lithium-ion) battery pack into the TRAKKER 2425 terminal. Note: You should always keep a charged main battery pack installed in the terminal to maximize the backup battery’s life. To install the main battery pack 1. If the battery door is not off, open the battery door by pushing down on the battery door latch and sliding it toward the bottom end of the terminal. Lift up the top edge of the battery door to remove it.
TOP
Battery door latch
BOTTOM 242XU.079
2. Hold the battery pack with the flat side facing down toward the inside of the battery compartment. The small arrow on the top of the battery pack must point toward the top (display) end of the terminal.
1-9
Page 32
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont
Co d e 39
3. Place the battery pack into the upper (larger) half of the battery compartment. Connector end
Connector pin (2 places)
Slots
242XU.082
4. Hook the slots on the bottom of the battery pack into the slots on the bottom of the battery compartment. 5. Slide the battery pack toward the top end of the terminal until it fits and locks into the connectors inside the bottom case. The battery pack must be all of the way forward to close the battery door.
1-10
Page 33
HelvC NugFont
Co d e 39 Getting Started
1
Installing the Battery Pack
242XU.102
6. On the inside of the battery door, make sure the rubber bumper is installed over the ridge near the wall. The rubber bumper keeps the battery pack in place. Rubber bumper
Wall Ridge
Battery door 242XU.148
1-11
Page 34
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont
Co d e 39
7. Hook the bottom edge of the battery door into the bottom case above the backup battery compartment. Push the door down to close it over the battery compartment. Push the battery door latch down and slide it toward the top end of the terminal to lock the door in place.
Battery door latch
242XU.088
Note: If the battery door will not shut, the battery pack is not correctly installed. Remove the battery pack and repeat Steps 2 through 6 to install the battery pack.
1-12
Page 35
HelvC NugFont
Co d e 39 Getting Started
1
Charging the Backup Battery You must fully charge the backup battery. The main battery pack charges the backup battery when required with the terminal turned on or off. Note: The backup battery charger operates between 32°F and 104°F (0°C and 40°C). If you are using the terminal in an environment that is outside this temperature range, the backup battery will not charge. To charge the backup battery 1. Install a fully charged main battery pack. For help, see “Installing the Main Battery Pack” earlier in this chapter. 2. Leave the terminal turned off and let the main battery pack charge the backup battery. The backup battery will be fully charged in approximately 18 hours. After you finish charging the backup battery, the main battery pack still has most of its power remaining. Note: The backup battery charges enough within 20 minutes to operate the terminal. However, the backup battery will only provide limited backup power if it is not fully charged.
1-13
Page 36
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont
Co d e 39
Configuring the Controller and Access Point The TRAKKER 2425 terminal can communicate with a host computer in Intermec’s 2.4 GHz network through the 0100 Access Point, the Model 200 Controller, and your Ethernet network. Host
TRAKKER 2425 terminals
0100 Access Point
Ethernet Model 200 Controller
242XU.095
Note: All devices in the 2.4 GHz network must have an IP address. All access points that the TRAKKER 2425 may communicate with must be in the same IP subnetwork. For help, see Chapter 4, “Operating the Terminal in a Network.” To use your T2425 terminal in Intermec’s 2.4 GHz network, you must first install the Model 200 Controller and the 0100 Access Point. For help, see the Model 200 Controller System Manual (Part No. 063439) and the 0100 Access Point User’s Manual (Part No. 062367).
1-14
Page 37
HelvC NugFont
Co d e 39 Getting Started
1
To configure the terminal, you must know the value of these parameters: • Controller IP address • Terminal IP address (for each T2425 terminal in the network) • RF domain (access point) • RF security identification (ID) (optional) (access point) Once you have configured the controller and access point, you can configure the terminal for the 2.4 GHz network.
Turning On the Terminal for the First Time Once the batteries are charged and a scan module is installed, you are ready to turn on the terminal and configure it. Important: You must have a scan module attached to use the terminal. A scan module is usually installed at the Intermec factory. For help, see “Using the Scan Module” in Chapter 2. To turn on the terminal q
1. Press the key on the top left of the keypad. The TRAKKER Antares screen appears.
1-15
Page 38
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont
Co d e 39
Note: If the TRAKKER Antares screen does not appear, you may have a problem with the batteries. Make sure the main battery pack is fully charged and installed correctly. Make sure a scan module is installed correctly. For help, see Chapter 6, “Troubleshooting.” Once the terminal has finished initializing the firmware, this warning screen appears. The terminal creates a configuration file the first time you turn it on.
*** WARNING *** TE configuration file not found. Press a key and a default one will be created.
242XU.129
2. Configure the terminal now. Follow the instructions in the next section, “Configuring the Terminal.”
)yT 2 M
Note: To configure the terminal, press and start the TRAKKER 2400 Menu System. If you press any other key, you will see messages that the terminal cannot connect to the controller. Follow the instructions in the next section, “Configuring the Terminal.”
1-16
Page 39
HelvC NugFont
1
Co d e 39 Getting Started
Configuring the Terminal You need to set these network parameters to begin using the terminal: • Time and date • Network activate • Controller IP address • Terminal IP address • RF domain • RF security identification (ID) You use the TRAKKER 2400 Menu System to set these parameters. Note: If the terminal is on a different IP subnetwork from the Model 200 Controller, you must also configure the default router and subnet mask. For help, see Chapter 4, “Operating the Terminal in a Network.”
Setting the Time and Date If you have not turned on the terminal, follow the instructions for “Turning On the Terminal for the First Time” earlier in this chapter.
) y T 2 M or scan this bar code label to access the TRAKKER
1. Press 2400 Menu System.
Enter Test and Service Mode
*..-.* *..-.* q y
Note: You must press the (Left Enter) key in this key sequence. The located just under the key.
y key is
1-17
Page 40
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont
Co d e 39
The Main Menu appears.
MAIN
MENU
Configuration Menu Diagnostics Menu System Menu About TRAKKER 2400
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.001
{
2. Press twice to choose the System Menu and then press System Menu appears. SYSTEM
MENU
Load Default Values Set Time and Date Store Configuration Upgrade Firmware
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.051
1-18
;. The