Page 311
HelvC NugFont
Co d e 39 Configuration Command Reference
8
RF Domain Purpose:
Defines a logical partition or subnetwork of the network. To establish communications, you must assign the same domain number to every RF device in a wireless network. The domain number you set on the T2425 terminal must match the domain that is set on each access point the terminal may communicate with. You can continue to collect data with the terminal as you roam in between access points as long as all the devices have the same domain number.
Default:
0
Syntax:
RWdata Acceptable values for data are any number from 0 to 15.
Scan:
1. Scan this bar code: Enter Accumulate Mode / Set RF Domain
*+/$+RW* *+/$+RW*
2. Scan a numeric value for data from these bar codes:
*0* *0*
*2*
*1* *1*
*3*
*2*
*3*
*4*
*5*
*6*
*7*
*8*
*9*
*4*
*6*
*8*
*5*
*7*
*9*
8-51
Page 312
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont
Co d e 39
RF Domain (continued) 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
RF Security Identification Purpose:
Defines the password you can set for secured transmission and receipt of data between devices in the network. To communicate, all 0100 Access Points and TRAKKER 2425 terminals in the subnetwork must have matching security IDs.
Default:
No characters or blank (disabled)
Syntax:
RSdata Acceptable values for data are up to 20 ASCII characters. When you enter the RS command without data, the RF security ID is disabled or set to no characters (blank). Note: You can only set the RF security ID with the 2.4 GHz network enabled. The Network Activate configuration command must be configured to 2.4 GHz RF Network before you can save any changes to the RF security ID command.
Scan:
To disable or set the RF security ID to no characters, scan this full ASCII bar code label: Disable RF Security ID
*$+RS* *$+RS*
Or:
8-52
To set the RF security ID to an ASCII character string:
Page 313
HelvC NugFont
Co d e 39 Configuration Command Reference
8
1. Scan this bar code: Enter Accumulate Mode / Set RF Security ID
*+/$+RS* *+/$+RS*
2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The RF security ID can be from 1 to 20 characters. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Notes:
If you view the RF security ID in the TRAKKER 2400 Menu System, the actual security ID does not display on the screen. The words, (ID unchanged), indicate that the password has not been changed in the current menu session. If you change the security ID, you see the new password until you exit the Configuration Menu and update the runtime configuration.
Example:
You want to set the security ID to the letters ABC. Scan this bar code label: Set RF Security ID to ABC
*$+RSABC* *$+RSABC*
8-53
Page 314
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont
Co d e 39
RF Wakeup On Broadcast Purpose:
Determines if the terminal can receive broadcast messages sent from the network. If the wakeup on broadcast is enabled, the terminal radio will turn on to receive broadcast messages. If this command is disabled, the terminal radio will ignore broadcast messages. Power Management Tip: If your network has many broadcast messages, you may want to disable the wakeup on broadcast command to preserve the main battery pack’s power.
Default:
Disabled
Syntax:
RBdata Acceptable values for data are: 0 1
Scan:
Disabled Enabled
One of these bar codes: Disable RF Wakeup On Broadcast
*$+RB0* *$+RB0*
Enable RF Wakeup On Broadcast
*$+RB1* *$+RB1*
8-54
Page 315
HelvC NugFont
Co d e 39 Configuration Command Reference
8
Scan Ahead Purpose:
Enables or disables scan ahead. If you enable this parameter, you can scan a number of labels that are held in a stack until the terminal can process the data. If you disable this parameter, the terminal processes each label you scan before you can scan the next label.
Default:
Disabled
Syntax:
SDdata Acceptable values for data are: 0 1
Scan:
Disabled (scan one label at a time) Enabled (scan many labels at a time)
One of these bar codes: Disable Scan Ahead
*$+SD0* *$+SD0*
Enable Scan Ahead
*$+SD1* *$+SD1*
8-55
Page 316
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont
Co d e 39
Scanner Mode Purpose:
Defines how the scanner operates when you press the Scan button or activate a cabled laser scanner. There are two types of modes: • In One-Shot mode, you must press the Scan button or activate the cabled laser scanner each time you want to scan a bar code. Once you scan a bar code, the scanner turns off. • In Automatic (Auto-trigger) mode, you press the Scan button once or activate the cabled laser scanner once to scan a series of bar codes. When you release the button or trigger, the scanner turns off. To scan the same bar code more than once, you must release the Scan button or trigger, or scan a different bar code before attempting a second scan.
Default:
One-Shot mode
Syntax:
SBdata Acceptable values for data are: 0 1
Scan:
One-Shot mode Automatic mode
One of these bar codes: Enable One-Shot Mode
*$+SB0* *$+SB0*
Enable Automatic Mode
*$+SB1* *$+SB1*
8-56
Page 317
HelvC NugFont
Co d e 39 Configuration Command Reference
8
Scanner Redundancy Purpose:
Defines the number of scans (voting) the scanner takes of the same label that must decode correctly for a good read of the label. Voting requires the terminal to decode the same bar code multiple times during a single scanner event, and to compare the decoded information a specific number of times before signaling a good read. There are three options: None Allows the terminal to accept the first good read, which speeds up terminal performance. This setting is recommended when scanning good quality bar codes. Normal The terminal decodes the bar code a minimum number of times in each scanner event. The number of comparisons that are made depends on each bar code symbology. High The terminal scans and decodes the bar code a maximum number of times in each scanner event. The specific number of comparisons depends on each bar code symbology. The high setting is recommended when scanning poor quality labels that may cause substitution errors. For example, when you scan Code 39 labels and the scanner redundancy is set to normal, two successive matching decodes in a single scanner event are required. When scanner redundancy is set to high, three successive matching decodes in a single scanner event are required.
Default:
Normal
Syntax:
SRdata Acceptable values for data are: 0 1 2
Scan:
None Normal High
One of these bar codes: None
*$+SR0* *$+SR0*
8-57
Page 318
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont
Scanner Redundancy (continued) Normal
*$+SR1* *$+SR1* High
*$+SR2* *$+SR2*
8-58
Co d e 39
Page 319
HelvC NugFont
Co d e 39 Configuration Command Reference
8
Scanner Selection Purpose:
Identifies the type of scanner you have connected to the TRAKKER 2425 terminal module for cabled scanners. The terminal can optimize the scanning performance by using the scanner you define in this command. Note: The Scanner Selection configuration command is only used when a module for cabled scanners is installed on the TRAKKER 2425 terminal. When you select a specific scanner, other scanners may not function properly. Your terminal may not work if you connect an incompatible scanner.
Default:
All compatible scanners
Syntax:
SSdata Acceptable values for data are: 0 1 2 3 4 5
Scan:
All compatible scanners (including wands) 146x CCD scanners 155x laser scanners 151x laser scanners 1545 laser scanner Compatible Symbol scanners (with reverse polarity enabled)
One of these bar codes: All Compatible Scanners
*$+SS0*
146x CCD Scanners
*$+SS1*
*$+SS0*
*$+SS1*
155x Laser Scanners
151x Laser Scanners
*$+SS2*
*$+SS3*
*$+SS2*
*$+SS3*
1545 Laser Scanner
Compatible Symbol Scanners
*$+SS4*
*$+SS5*
*$+SS4*
*$+SS5*
8-59
Page 320
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont
Co d e 39
Scanner Timeout Purpose:
Defines the maximum length of time the scanner stays after you press the Scan button or activate a cabled laser scanner.
Default:
Disabled (no timeout)
Syntax:
SAdata Acceptable values for data are: 0 1-60
Scan:
Disabled Shutoff time in seconds
1. Scan this bar code: Enter Accumulate Mode / Change Scanner Timeout
*+/$+SA* *+/$+SA*
2. Scan a numeric value for data from these bar codes:
*0* *0*
*2*
*1*
*3*
*2*
*3*
*4*
*5*
*6*
*7*
*8*
*9*
*4*
*6*
*8*
8-60
*1*
*5*
*7*
*9*