Page 301

HelvC NugFont

Co d e 39 Configuration Command Reference

8

MSI Purpose:

Enables or disables decoding of MSI symbology. MSI code is similar to Plessey code. MSI code includes a start pattern, data characters, one or two check digits, and a stop pattern.

Default:

Disabled

Syntax:

CNdata Acceptable values for data are:

Scan:

First digit:

0 1 2 3

Disabled No check digits 1 modulus 10 check digit 2 modulus 10 check digit

Second digit:

0 1

Discard check digit Transmit check digit

One of these bar codes: Disable MSI

*$+CN00* *$+CN00*

MSI Without Check Digits

*$+CN10* *$+CN10*

MSI With 1 Modulus 10 Check Digit, Discard Check Digit

*$+CN20* *$+CN20*

MSI With 1 Modulus 10 Check Digit, Transmit Check Digit

*$+CN21* *$+CN21*

8-41

Page 302

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

MSI (continued) MSI With 2 Modulus 10 Check Digits, Discard Check Digits

*$+CN30* *$+CN30*

MSI With 2 Modulus 10 Check Digits, Transmit Check Digits

*$+CN31* *$+CN31*

8-42

Co d e 39

Page 303

HelvC NugFont

Co d e 39 Configuration Command Reference

8

Network Activate Purpose:

Enables or disables network communications between the TRAKKER 2425 terminal and other devices in the 2.4 GHz network. When you enable this parameter, the terminal attempts to establish communications with the Model 200 Controller. When you disable this parameter, the network is disabled, no RF communications are provided, and the radio is turned off. Note: You must enable the Network Activate parameter to use the terminal for data collection.

Default:

Disabled

Syntax:

NAdata Acceptable values for data are: 0 1

Scan:

Disabled 2.4 GHz RF network (enabled)

One of these bar codes: Disable Network Activate

*$+NA0* *$+NA0*

Enable 2.4 GHz RF Network

*$+NA1* *$+NA1*

8-43

Page 304

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Network Loopback Purpose:

Transmits all messages received from the Model 200 Controller back to the controller. Messages received by the radio are not passed on to the terminal applications unless they are configuration commands. Messages continue to be looped back to the controller as long as this feature is enabled. Messages originating from the terminal are still transmitted to the controller. Use the Network Loopback parameter to troubleshoot RF communications problems.

Default:

Disabled

Syntax:

NLdata Acceptable values for data are: 0 1

Scan:

Disabled Enabled

One of these bar codes: Disable Network Loopback

*$+NL0* *$+NL0*

Enable Network Loopback

*$+NL1* *$+NL1*

8-44

Page 305

HelvC NugFont

Co d e 39 Configuration Command Reference

8

Plessey Purpose:

Enables or disables decoding of Plessey symbology. Plessey code is pulsewidth modulated like most other bar codes. It includes a start character, data characters, an eight-bit cyclic check digit, a termination bar, and usually a reverse start character. The code is continuous and not selfchecking. You need to configure two parameters for Plessey code: Start Code and Check Digit.

Default:

Disabled

Syntax:

CIdata Acceptable values for data are: 00 10 30 31

Scan:

Disabled Plessey with reverse start code Transmit check digit Discard check digit

To disable Plessey: Disable Plessey

*$+CI00* *$+CI00*

Or:

To set Plessey, complete these steps: 1. Scan this bar code: Plessey With Reverse Start Code

*$+CI10* *$+CI10*

2. Scan one of these bar codes to transmit or retain the check digit: Transmit Check Digit

Discard Check Digit

*$+CI30*

*$+CI31*

*$+CI30*

*$+CI31*

8-45

Page 306

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Postamble Purpose:

Sets the postamble that is appended to any data you scan with the terminal. Common postambles include cursor controls such as tabs or carriage return line feeds. For help on using the TRAKKER 2400 Menu System to configure the Postamble, see “Entering ASCII Control Characters” in Chapter 3. Note: You can set the postamble to use characters from the extended ASCII character set such as the Field Exit code for 5250 TE. For help, see “Auto-Advancing Through Fields on 5250 TE Screens” in Chapter 5.

Default:

No characters (disabled)

Syntax:

AEdata Acceptable values for data are up to 25 ASCII characters. If you enter the AE command without data, the postamble is disabled. If you are entering quotation marks as data or grouping configuration commands, you need to enclose the data within quotation marks (see the example). Note: To scan a bar code label that includes quotes, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter.

Scan:

To disable the postamble, scan this bar code: Disable Postamble

*$+AE* *$+AE*

Or:

To set the postamble to an ASCII character string: 1. Scan this bar code: Enter Accumulate Mode / Set Postamble

*+/$+AE* *+/$+AE*

8-46

Page 307

HelvC NugFont

Co d e 39 Configuration Command Reference

8

2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The postamble can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Example:

You want to set a postamble that includes quotation marks. Enter the postamble by scanning this full ASCII bar code label: Set Postamble to “B”

*/D/KAE/B/B/BB/B/B/B* *$+AE"""B"""*

You must enclose the data within quotation marks and precede each quotation mark with another quotation mark so that the quotation marks are not treated as the end of the data.

8-47

Page 308

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Preamble Purpose:

Sets the preamble that precedes any data you scan with the terminal. Common preambles include a data location number or an operator number. For help on using the TRAKKER 2400 Menu System to configure the Preamble, see “Entering ASCII Control Characters” in Chapter 3. Note: You can set the preamble to use characters from the extended ASCII character. For help, see “Auto-Advancing Through Fields on 5250 TE Screens” in Chapter 5.

Default:

No characters (disabled)

Syntax:

ADdata Acceptable values for data are up to 25 ASCII characters. When you enter the AD command without data, the preamble is disabled. If you are entering quotation marks as data or grouping configuration commands, you need to enclose the data within quotation marks (see the example). Note: To scan a bar code label that includes quotes, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter.

Scan:

To disable the preamble, scan this bar code: Disable Preamble

*$+AD* *$+AD*

Or:

To set the preamble to an ASCII character string: 1. Scan this bar code: Enter Accumulate Mode / Set Preamble

*+/$+AD* *+/$+AD*

8-48

Page 309

HelvC NugFont

Co d e 39 Configuration Command Reference

8

2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The preamble can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Example:

You want to set a preamble that includes quotation marks. Enter the preamble by scanning this full ASCII bar code label: Set Preamble to “B”

*/D/KAD/B/B/BB/B/B/B* *$+AD"""B"""*

You must enclose the data within quotation marks and precede each quotation mark with another quotation mark so that the quotation marks are not treated as the end of the data.

8-49

Page 310

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Resume Execution Purpose:

q q

Default:

Allowed

Syntax:

ERdata Acceptable values for data are: 0 1

Scan:

Not allowed Allowed

One of these bar codes: Resume Execution Not Allowed

*$+ER0* *$+ER0*

Resume Execution Allowed

*$+ER1* *$+ER1*

8-50 q

Defines the way in which the terminal resumes when you press to turn on the terminal. If you set this parameter to resume not allowed and you press to turn on the terminal, the terminal will boot and restart the default application. If you set this parameter to resume allowed and press to turn on the terminal, the terminal resumes exactly where it was when you turned off the terminal.