Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 11 of 46

TRAKKER Antares 2425 Hand-Held Terminal User's Manual, pages 101 to 110

Pages 101 to 110 of 452

The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2425

Page 101

HelvC NugFont

Co d e 39 Configuring the Terminal

3

This chapter explains how to configure the terminal, discusses the terminal’s configuration parameters, describes how to restore the default configuration, and concludes by listing the configuration parameters.

How to Configure the Terminal You can configure the TRAKKER 2425 terminal by using either of the methods described in detail in this chapter: Using the TRAKKER 2400 Menu System With menus and dialog boxes, the TRAKKER 2400 Menu System lets you view the current configuration and modify configuration parameters. Configuring the terminal by scanning bar codes You can change the terminal’s current configuration by scanning Code 39 or Code 93 bar code labels that contain configuration commands. This is a fast, easy way to change the terminal’s configuration. You can scan the bar code labels in this manual, or you can create your own bar code labels. Note: You can also configure the terminal over the network from the Model 200 Controller or the host computer. For help, see “Configuring the Terminal Over the Network” in Chapter 4.

Learning About Configuration Parameters You can customize many operating characteristics of the TRAKKER 2425 terminal, such as the volume of its audio signals and the bar code symbologies it decodes. These characteristics are controlled by configuration parameters. The values you set for the configuration parameters determine how the terminal operates. By customizing the terminal’s configuration, you can set up the terminal to operate easily and efficiently within your data collection system. Note: To learn the purpose and syntax of each configuration parameter or command, see Chapter 8, “Configuration Command Reference.” The commands are listed alphabetically.

3-3

Page 102

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

The configuration parameters can be organized into three groups, which are discussed in the next sections: bar code symbologies, communications, and general operation. When you configure the terminal, you are performing one or more of these tasks: • Choosing the Symbologies the Terminal Decodes • Specifying How the Terminal Will Communicate • Controlling How the Terminal Will Operate

Choosing the Symbologies the Terminal Decodes This list contains all the bar code symbologies the terminal can decode: • Codabar

• Code 2 of 5

• Interleaved 2 of 5 (I 2 of 5)

• Code 11

• Code 39

• MSI

• Code 128

• Code 49

• Plessey

• Code 16K

• Code 93

• UPC/EAN

When the terminal ships, only these three symbologies are enabled: • Code 39 • Code 128 • UPC/EAN If you are using one of the other symbologies to encode your bar code labels, you need to configure the terminal and enable the symbology. To quickly enable symbologies, see “Enabling Bar Code Symbologies” in Chapter 1. To ensure that the terminal can operate quickly and efficiently, you should enable only the bar code symbologies that you are going to scan. When you enable each bar code symbology, you may need to set a check digit, the length of the bar code label, or other options. For help, see Chapter 8, “Configuration Command Reference.”

3-4

Page 103

HelvC NugFont

Co d e 39 Configuring the Terminal

3

Specifying How the Terminal Will Communicate Before you can use the terminal to communicate with other devices in your network, you must set the network parameters, radio frequency parameters, and address information. For example, you must set the Controller IP Address so the terminal can transmit data to and receive data from the Model 200 Controller. To learn how to configure the terminal to fit into your network, see Chapter 4, “Operating the Terminal in a Network.”

Controlling How the Terminal Will Operate The operating parameters let you adjust the way the terminal operates. By customizing the operating parameters, you can: • set the terminal to automatically shut off after a specified length of time. • set the terminal to resume applications or restart applications. • modify data transactions by appending the time. • modify bar code data by using preambles and postambles. • enable or disable specific reader commands. • change the frequency and volume of the beeper or audio signals. • control the display contrast and backlight timeout. • enable or disable the keypad clicker and keypad caps lock. • customize the way the scan module operates by selecting scan ahead data buffering, type of scanner device, decode security level, scanner timeout value, and trigger modes.

3-5

Page 104

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Configuring the Terminal With the Menu System The TRAKKER 2400 Menu System is a menu-driven application that lets you configure the terminal, view system information, and run diagnostics. You can access the TRAKKER 2400 Menu System while running any application. To access the TRAKKER 2400 Menu System

) y T 2 M or scan this bar code: Note: You must press the y (Left Enter) key in this key sequence, not the z (Right Enter) or ; keys.

• Press

Enter Test and Service Mode

*..-.* *..-.*

The Main Menu appears, displaying four menu options.

MAIN

MENU

Configuration Menu Diagnostics Menu System Menu About TRAKKER 2400

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.001

Configuration Menu Choose the Configuration Menu to configure bar code symbologies, network and communications parameters, and the terminal’s operating characteristics.

3-6

Page 105

HelvC NugFont

Co d e 39 Configuring the Terminal

3

Diagnostics Menu Choose the Diagnostics Menu to run hardware, software, or system diagnostics to help analyze and fix problems on the terminal. You can also view information about the system. For help, see “Running Diagnostics” in Chapter 6. System Menu Choose the System Menu to load the default configuration, set the time and date, store the terminal’s configuration in flash memory, and upgrade the firmware. About TRAKKER 2400 Choose this option to see part number and version information about the boot code and firmware loaded on the T2425 terminal. You may need this information if you are working a problem with an Intermec representative.

Exploring the Configuration and System Menus When you access the TRAKKER 2400 Menu System, the Main Menu appears. You use the Configuration Menu and the System Menu to configure the terminal. The Configuration Menu contains these commands: CONFIGURATION MENU Symbologies Menu Communications Menu Terminal Menu

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.010

Symbologies Menu Choose the Symbologies Menu to configure and activate the bar code symbologies the terminal can decode. An asterisk (*) on the Symbologies Menu indicates that the symbology is active. For help, see “Choosing the Symbologies the Terminal Decodes” earlier in this chapter.

3-7

Page 106

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Communications Menu Choose the Communications menu to configure the primary network parameters, the advanced network parameters, and the RF driver parameters. For help, see Chapter 4, “Operating the Terminal in a Network.” Terminal Menu Choose the Terminal Menu to configure the way the terminal, keypad, scanner, or display operate. For help, see “Controlling How the Terminal Will Operate” earlier in this chapter. The System Menu contains these commands: SYSTEM

MENU

Load Default Values Set Time and Date Store Configuration Upgrade Firmware

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.051

Load Default Values Lets you load the default configuration values. For help, see “Restoring the Terminal’s Default Configuration” later in this chapter. Set Time and Date Lets you set the current time and date. For help, see “Setting the Time and Date” in Chapter 1. Store Configuration Stores the current configuration in flash memory, including any changes you have made in the menu system. When you exit the TRAKKER 2400 Menu System, you will also be prompted to save your changes. For help, see “Exiting the TRAKKER 2400 Menu System” later in this chapter. Upgrade Firmware Lets you upgrade the system firmware on the terminal. For help, see “Upgrading the Firmware” later in this chapter.

3-8

Page 107

HelvC NugFont

Co d e 39 Configuring the Terminal

3

You can use the keystrokes described next to move around in the TRAKKER 2400 Menu System, or you can scan bar code labels. For a list of bar code labels, see the “Full ASCII Bar Code Chart” in Appendix B.

Selecting Menus and Commands

[ or { to choose a menu name from the Main Menu. Then press ;, y z to display the commands in the selected menu. In this example, you {{; to display the System Menu: Note: In the menu system, the ;, y , and z keys all work the same way. Press , or press

MAIN

MENU

SYSTEM

MENU

Configuration Menu Diagnostics Menu System Menu About TRAKKER 2400

Load Default Values Set Time and Date Store Configuration Upgrade Firmware

_` Select item [Enter] Next screen [F1] Help [Esc] Exit

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.058

;

[ {

Press or to choose a command or option from a menu, and then press to execute the command or option. Note: You can press exit a help screen.

! at any time to display an online help screen. Press d to

3-9

Page 108

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Filling In Fields and Marking Check Boxes Screens list the options for each configuration parameter, diagnostic, or system option. Below each option name is either a toggle field or an entry field:

] , } , or : to view the options for that field. • In an entry field, you type a value into the field. To edit the data in an entry field, use the ] , } , ) : , or : keys. On a terminal emulation

• In a toggle field, you press keypad, you can also use the Delete and Insert keys to edit an entry field.

:

For example, the Code 49/Code 16K screen has toggle and entry fields. The Code 49 field is a toggle field. Press to toggle between Enabled and Disabled. The Function Codes field for F1, F2, and F3 are entry fields. You type a value into the field for each function code. CODE Code

49 49:

/

CODE

16K

Enabled

Code 49 Function Codes: F1: F2: \x0D\x0A F3: Code 16K: Standard OK

CANCEL 242XU.052

Some screens contain check boxes. Check boxes are used when more than one option can be selected at one time. To mark or clear check boxes

:

:

• Press . For example, to disable the Backlight reader command, choose the Backlight check box and press to clear the check box.

3-10

Page 109

HelvC NugFont

Co d e 39 Configuring the Terminal

3

Marking or Clearing Check Boxes on the Reader Command Menu READER COMMAND MENU [Space] to enable or disable a command [X] Backlight [X] Backspace [X] Change Config [X] Clear [X] Default Config [X] Enter Accum [X] Exit Accum [X] Multi-Read [X] Reset more

[X] Scanner On [X] Scanner Off [X] Test & Service

OK

CANCEL

_

242XU.053

To move to the next field • Press

{ or < .

To move to the previous field • Press

[.

3-11

Page 110

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Entering ASCII Control Characters You can include ASCII control characters in a postamble or preamble in the TRAKKER 2400 Menu System. For a definition of the postamble or preamble, see Chapter 8, “Configuration Command Reference.” Note: You can also configure the postamble or preamble to characters from the extended ASCII character set such as the Field Exit code for 5250 TE. For help, see “Auto-Advancing Through Fields on 5250 TE Screens” in Chapter 5. To enter ASCII control characters for a preamble or postamble 1. Decide which ASCII control character you want to set for the preamble or postamble. Look up the control character in the Full ASCII Table in Appendix B and find the two-digit hexadecimal number. For example, you find ETX in the Full ASCII Table and learn that 03 is the two-digit hexadecimal number for ETX. 2. Use the TRAKKER 2400 Menu System to configure a preamble or postamble. From the Main Menu, choose Configuration Menu. 3. From the Configuration Menu, choose Terminal Menu. 4. From the Terminal Menu, choose Preamble/Postamble. PREAMBLE

/

POSTAMBLE

Preamble: abc Postamble: \x0D\x0A

OK

CANCEL 242XU.057

5. Move the cursor to the field for the preamble or postamble.

3-12