Page 91

HelvC NugFont

Co d e 39 Learning How to Use the Terminal

2

Using the Scan Module You use the scan module accessories with the TRAKKER 2425 terminal to scan and enter bar code data. The terminal decodes the bar code label and enters the data or command you scanned. There are two types of scan modules available: • Module for cabled scanners • Standard range scan module Important: You must have a scan module attached to use the terminal. The module for cabled scanners has a port to attach a wand, laser scanner, or CCD scanner. The standard range scan module has an integrated laser scanner. For more information about either scan module, see the instruction sheet that ships with the module. You can scan bar code labels with the integrated standard range scan module, or with the scanner device that is connected to the module for cabled scanners. When you unpack the terminal and begin using it, only three bar code symbologies are enabled: Code 39, Code 128, and UPC/EAN. If you are using bar code labels that are encoded in another symbology, you need to enable that symbology on the terminal. For help, see “Enabling Bar Code Symbologies” in Chapter 1, or find the symbology in Chapter 8, “Configuration Command Reference.” Note: The Scan button on the terminal keypad does not activate the scanner device connected to the module for cabled scanners. The next sections cover these topics: • Installing a Scan Module • Using the Standard Range Scan Module • Scanning Options

2-37

Page 92

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Installing a Scan Module To use the terminal, you must have a scan module installed on the terminal. The scan module is usually installed at the Intermec factory. You may want to change the scan module and install another type of scan module on the terminal. Use these instructions to remove and install the scan module. Note: Observe all static electricity precautions before installing a module. To install a scan module 1. Make sure the terminal is off and then lay it face down on a clean and sturdy work surface. 2. Use a Phillips screwdriver and remove the three screws that secure the scan module to the terminal. 3. Remove the existing scan module from the terminal. 4. To install the module, align the module guides with the guides on the terminal (see illustration). Gently press down on the module to seat the connector guide pins and the module connector into the connector on the terminal. Note: The module guide pins and connector should fit easily into the connector on the terminal. DO NOT force the module into the connector or you may damage the module connector, the terminal connector, or both. 5. Insert the three screws into the module and tighten them to secure the scan module to the terminal.

2-38

Page 93

HelvC NugFont

Co d e 39 Learning How to Use the Terminal

2

Installing a Scan Module Screw Screw Screw Scan module Scan module guide (2 places)

Terminal guide (2 places)

242XU.040

2-39

Page 94

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Using the Standard Range Scan Module The standard range laser scan module emits a beam of laser light that is visible on a bar code label as you scan it. The terminal decodes the bar code label and enters the data or command you scanned. Warning Do not look directly into the window area or at a reflection of the laser beam while the laser is scanning. Long-term exposure to the laser beam can damage your vision. Advertissement Ne regardez pas directement la réflexion d’un rayon laser ou dans la fenêtre du laser lorsque celui-ci est en opération. Si vous regardez trop longtemps un rayon laser, cela peut endommager votre vue.

To scan a bar code label with the standard range scan module 1. Press q to turn on the terminal.

2. Hold the terminal at a slight angle a few inches from the bar code label. The laser scanner window in the scan module must be pointing toward the label. 3. Push the Scan button on the keypad. Direct the beam so that it falls across all bars in the bar code label. After the terminal successfully reads the label, you hear a high beep. The scanner stays on or turns off depending on the scanning options you have configured. When the scanner laser beam is on, both scanner light emitting diodes (LEDs) at the top of the keypad are lit in a yellow color. Once the bar code label is scanned successfully, the LEDs are lit in a green color. The LEDs turn off after 2 seconds unless you start scanning another label. Note: Some of the scanning options described in the next section allow you to scan multiple bar code labels without having to press the Scan button each time. The yellow LEDs stay lit any time the scanner laser beam is on. 4. Release the Scan button.

2-40

Page 95

HelvC NugFont

Co d e 39 Learning How to Use the Terminal

2

Scanning Labels With the Standard Range Scan Module *B

02

E

R

8*

T

R

A

K

K

E

R

A

N

T

A

41

24

S

25

Scanner LED indicators (2 places)

F5

9

I/O

F4

6

F3

8

F2

1

0

4

2

7

5

3

F1 er

Ent Fn Fn

L

E J

D

R C

A

O

I

L

X

R

P

Esc

W

Q

K

Y

S

M

G F

T

N

H

B

V b

Ta

U Z

Scan button

242XU.034

To successfully read a bar code label, the laser beam in the scan module must see all the bars in a label and a “quiet zone” at each end of the label. A quiet zone is a clean, non-printed space.

*NANCY* Quiet zone before and after bar code 242XU.076

2-41

Page 96

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

With the standard range scan module, you will have the best success if you hold the terminal so that the horizontal reading angle is near zero and the vertical reading angle is near 20 degrees. To get the best scan angle, hold the terminal so that the scan module is pointing toward bar code label. Tilt the terminal up or down slightly (20 degrees). You can also watch the laser beam. The laser beam becomes the brightest at the best scan angle. Optimum scan angles vary with the type and printing quality of the bar code label, the distance of the terminal from the label, and the lighting of the work area. Note: You should not scan the bar code label “straight on.” In a 2-degree conical “dead zone” directly above the label, the laser beam may reflect back into the scanner window and prevent the terminal from reading the label. At certain angles and straight on, you may not see the laser beam.

Scanning Options You can set several configuration command parameters to configure the laser scanner to meet your needs. The parameters available are: Decode Security Defines the security level to use when decoding bar codes. When you select a lower decode security level, the terminal can decode bar codes with poorer print quality. Scan Ahead Allows you to scan a number of bar code labels at one time. The labels are held in a stack until the terminal can process the data. Scanner Mode Defines how the scanner operates when you press the Scan button or activate a cabled laser scanner. In One-Shot mode, the laser turns on and stays on until you release the button or scanner trigger, or a label is decoded. In Automatic mode, you can continuously scan bar code labels without having to release the button or scanner trigger between labels. Scanner Redundancy Defines the number of scans (voting) the scanner takes of the same label. When set, voting requires the terminal to decode the same bar code label multiple times during a single scanner event, and compare the decoded information for a match before signaling a good read.

2-42

Page 97

HelvC NugFont

Co d e 39 Learning How to Use the Terminal

2

Scanner Selection Identifies the type of scanner you have connected to the TRAKKER 2425 terminal module for cabled scanners. The terminal can optimize the scanning performance by using the scanner you define in this command. Scanner Timeout Defines the maximum length of time the scanner stays on each time you press the Scan button or activate the cabled laser scanner. Scanner Trigger Allows you to set the triggering to level or edge triggering. With level triggering, you activate the scanner and the laser turns on and stays on until you release the Scan button or the trigger on a cabled scanner. In edge triggering, you activate the scanner and the laser turns on and stays on until you activate the scanner a second time, or the scanner timeout turns the laser off. There are several ways to set the scanner commands on the terminal. For help configuring the terminal, see Chapter 3, “Configuring the Terminal.” For help using the scanner configuration commands, see Chapter 8, “Configuration Command Reference.”

2-43

Page 98

This page is a scan with no text; see it in the PDF.

Page 99

HelvC NugFont

Co d e 39

3 Configuring the Terminal

Page 100

HelvC NugFont

Co d e 39