The text of a manual · part 39 of 64
Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual: Chapter 7 - Running Diagnostics, pages 313 to 320
Pages 313 to 320 of 558, from Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual
The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2420 and Intermec 2425
Page 313
Nugg
Co de
Running Diagnostics 39
7
Scanner Test Purpose:
Where Available: Sample Screen:
Use the Scanner Test to make sure the laser scanner, Scan button, or scanner trigger are operating correctly. You can test the integrated laser scan module or the scanner attached to the module for cabled scanners. Hardware Diagnostics menu SCANNER
TEST
Press ENTER to turn the laser on for 3 seconds. Or, scan test the a label laser.
[Enter] Execute [Esc] Exit to test
242XU.137
Definition:
To start the test, press . If the laser scanner turns on, the scanner is working correctly. If the laser scanner does not turn on, you may have a problem with the scan module or the laser scanner attached to the module for cabled scanners. If you are using a module for cabled scanners, make sure you are using a laser scanner that is supported on the terminal. Also, check to make sure the laser scanner is attached to the module for cabled scanners. If the laser scanner did turn on in the first test, try scanning a bar code label. To scan a label, press the Scan button on the terminal or pull the trigger on a laser scanner attached to the module for cabled scanners. If the laser scanner turns on, the Scan button or laser scanner trigger is working correctly. If the laser scanner does not turn on, you may have a problem with the Scan button on the terminal or the laser scanner trigger on the attached laser scanner. For help with scanner problems, contact your local Intermec service representative.
7-17
Page 314
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugg Co de
39
Serial Loopback Test Purpose:
Where Available: Sample Screen:
Use the Serial Port Loopback test to verify that the hardware for the RS-232 serial port is functioning correctly. To run this diagnostic test, you must connect the terminal to a host computer or other serial device via the communications dock or optical link adapter. Choose the Main Board Menu from the Hardware Diagnostics menu. SERIAL
PORT
LOOPBACK
WAITING
/CTS 0 COM Port : Baud Rate : Parity : Data Bits : Echo RX Data Echo /CTS on [Esc]
1 38400 None 8 on TX /RTS
Exit
242XU.144
Definition:
The serial port test begins immediately. If the serial port hardware is functioning correctly, the terminal displays WAITING and then RECEIVING. The Serial Port Loopback test uses the serial communications settings that are listed on the bottom half of the screen. On the host, you can use a serial communications package to send data to the terminal. If the terminal is communicating with the host, the data is echoed back. If there is a problem, an error message appears on the terminal screen. The status information on the screen is updated every 500 ms. For help with serial port errors, contact your local Intermec service representative.
7-18
Page 315
Nugg
Co de
Running Diagnostics 39
7
Defining the System Diagnostics Screens Each system diagnostic screen is defined in this section.
Access Point Purpose:
Use the Access Point screen to get version and address information about the access point the terminal is communicating with across the 2.4 GHz RF network. Note: The Access Point diagnostic applies only to the T2425.
Where Available:
System Diagnostics menu
Sample Screen:
ACCESS Radio ROM V1.6EB
POINT
Ver:
Radio MAC Addr: 0020A6306510 Access Point SHIPPING
Name:
Access Point 0020A6301365
MAC:
[Esc]
Exit
242XU.139
Definition:
The screen displays the radio ROM firmware version, radio MAC (machine) address, the access point name, and the access point MAC. If you have a problem with the radio or the connection to the access point, use the information on this screen to troubleshoot your network configuration.
7-19
Page 316
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugg Co de
39
Application Efficiency Purpose:
Where Available: Sample Screen:
Use the Application Efficiency screen to find out if your application is making the best use of and maximizing battery life on the terminal. System Diagnostics menu APP EFFICIENCY Subsystem Versions Application is running at 90% 80%
100% POOR
GOOD
Battery life affected by application efficiency. [Esc] is
Exit 242XU.064
Definition:
7-20
The screen displays the application efficiency percentage. The closer the percentage is to 100%, the more efficient the application is at using battery power. The terminal automatically goes into an internal Standby mode to draw power at a lower level when less power is required. An efficient application uses the TRAKKER Antares PSK (Programmer’s Software Kit) functions to wait for events to occur and it does not poll in an infinite loop. When programmed correctly with the PSK or EZBuilder, the application does not prevent the terminal from going into Standby mode and uses the terminal’s battery power as efficiently as possible.
Page 317
Nugg
Co de
Running Diagnostics 39
7
Malloc Application Information Purpose:
Where Available: Sample Screen:
A programmer or application developer can use the Malloc Application Information screen to see how memory is allocated and used by the current application. Choose the Malloc Info Menu from the System Diagnostics menu. APPLICATION Total Free: 0000064656 Largest Free: 0000064656 Fragments: 00001 Allocated Blocks: 00001
OK 242XU.171
Definition:
The screen displays the memory allocation used by the application. You can view the total free memory, the largest block of free memory, number of memory fragments, and the total number of allocated blocks of memory. You can use this diagnostic screen to troubleshoot a memory leak where the application is mallocing memory, but not freeing memory.
7-21
Page 318
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugg Co de
39
Malloc Firmware Information Purpose:
Where Available: Sample Screen:
A programmer or application developer can use the Malloc Firmware Information screen to see how memory is allocated and used in the terminal firmware. The firmware includes the operating environment, firmware, drivers, and TRAKKER Antares 2400 Menu System. Choose the Malloc Info Menu from the System Diagnostics menu. FIRMWARE Total Free: 0000007040 Largest Free: 0000006768 Fragments: 00002 Allocated Blocks: 00015
OK 242XU.172
Definition:
7-22
The screen displays the memory allocation for the terminal firmware. You can view the total free memory, the largest block of free memory, number of memory fragments, and the total number of allocated blocks of memory.
Page 319
Nugg
Co de
Running Diagnostics 39
7
Serial Port Test Purpose:
Where Available:
Use the Serial Port Test screen to test or troubleshoot serial communications between the terminal and the host computer or serial device. To run this diagnostic test, you must connect the terminal to a host or other serial device via the communications dock or optical link adapter. System Diagnostics menu
Sample Screen:
SERIAL
PORT
Select Com. 1,4, Esc :
TEST
Port: 1
F1:Port Select :1 F2:Keypad Echo : ON F3:Scanner Echo: ON F4:Continous TX: OFF F5:Exit -
242XU.170
Definition:
Press to test the RS-232 serial communications port. The screen displays the function key options you can use in this diagnostic screen. You may see the message “Port Not Available” if your application is currently using the serial port. You need to run an application that does not use the serial port for this diagnostic test. F1
Selects the serial port.
F2 Toggles the keypad echo on and off. If you turn the keypad echo on, characters you type on the keypad are displayed on the bottom line of the screen and transmitted to the host. F3 Toggles the scanner echo on and off. If you turn the scanner echo on, the bar code label you scan is displayed on the bottom line of the screen and transmitted to the host. F4 Toggles the Continuous Transmit mode on and off. If you turn continuous transmit on, the terminal continuously sends out a string of 10 characters. F5
Exits the Serial Port Test diagnostic screen.
On the host, you use an RS-232 serial communications package to receive data from the terminal. To test serial communications, enter or scan data on the terminal. If the terminal is communicating with the host, you will see the data. If there is a problem, check the serial port parameters and make sure they match the host settings. For help with serial port errors, see Chapter 6, “Troubleshooting,” or contact your local Intermec service representative.
7-23
Page 320
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugg Co de
39
Subsystem Versions Purpose:
Where Available: Sample Screen:
If you are discussing a problem with Intermec, you can use the Subsystem Versions screen to tell the Intermec representative the exact version of firmware subsystems loaded on the terminal. System Diagnostics menu SUBSYSTEM Name Network RF Driver Decodes Scanner Label Task Rdr Cmd Proc Term Serv Serial Port Menu System Keypad
[Enter] Next [Esc] Exit
VERSIONS Version 020007 020007 020005 020003 020004 020007 020006 020007 020006 020004 screen
242XU.136
Definition:
Press to display the next screen of subsystem information. If you are having a specific problem with one system, note the version loaded on the terminal before contacting your local Intermec service representative. Note: RF driver, network, or radio subsystem information does not apply to the T2420 since it does not have a radio.
7-24