Page 305

Nugg

Co de

Running Diagnostics 39

7

Task Status Purpose:

Where Available:

A programmer can use the Task Status screens to view the task name, stack, and the percentage of time a task has been running. You can also use the Task Status screen to determine the type of RF network protocol, TCP/IP or UDP Plus, loaded on the terminal. Software Diagnostics menu

Sample Screen:

TASK SLOT 0: 1: 2: 3: 4: 5: 6: 7: 8: 9: 10:

STATUS

ADDRESS ----:---SM UDP+ ----:---Label Task Serial Port Menu System PM APP ID ----:----

[Enter] Next [Esc] Exit

TASK %TIME 00.5% 00.1% 00.7% --.-% 00.0% 00.0% 02.0% 00.0% 00.0% 95.6% --.-% screen

SLOT 0: 1: 2: 3: 4: 5: 6: 7: 8: 9: 10:

STATUS

STACK ----:---1B8F:0010 1A48:0010 ----:---19F6:0010 19B5:0010 1944:0010 18E3:0010 18C2:0010 18A1:0010 ----:----

[Enter] Next [Esc] Exit

UNUSED ---0381 0010 ---029C 0339 03A5 0394 011C 0110 ---- screen

242XU.131

Definition:

The %Time field measures the relative amount of time that a given software task or component is active. For example, Idle Task (ID) in the Power Management software is a component. The %Time that Idle Task is active is directly proportional to battery life. The ID (idle) address should have the largest %Time field. If any other address (task) is large, you probably have a problem. You can also check the task list to determine the RF network protocol loaded on the terminal. Check the list of task names for UDP+ or TCP/IP. A task name of UDP+ means the terminal uses UDP Plus for RF communications. A task name of TCP/IP means the terminal uses TCP/IP for RF communications. To refresh the statistics and start from a known point in time, use the Clear Task Profiles diagnostic option to clear the task status counters.

7-9

Page 306

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugg Co de

39

Defining the Hardware Diagnostics Screens Each hardware diagnostic screen is defined in this section.

Battery/PIC Status Purpose:

Where Available:

Sample Screen:

Use the Battery/PIC status screens to get information about the main (lithium-ion) battery pack and the backup (NiCad) battery. Hardware Diagnostics menu, Battery/PIC Status and then choose either Main Battery/PIC or Backup Battery/PIC BATTERY/PIC

MONITOR

Main Battery Capacity E

F 100%

Main

Battery

Volts

8.200V (Ea) Temp: 25C (A4) Main Charging: NO PIC Rev.:8 [Esc]

Temp:

25C

(A4)

Backup Charging: PIC Rev.:

NO

8

[Esc] Exit

Exit 242XU.080

Definition:

BATTERY/PIC MONITOR Backup Battery Good Backup Battery Volts 10.80V (BC)

242XU.194

Main Battery Capacity tells you the percentage of battery power remaining in the battery pack. You can continue using the battery pack until the Battery icon appears on the screen to indicate a low battery. The backup battery test shows that the backup battery power is either GOOD or LOW. If the status is LOW, turn off the terminal. Let the main battery pack charge the backup battery. The backup battery will be fully charged in approximately 18 hours. You can also use these screens to find out the current volts, temperature and charging status. For both screens, the PIC Rev field is the firmware version that is running on the battery monitory processor. The number in parentheses after the volts and temperature is the hexadecimal value returned from the processor.

7-10

Page 307

Nugg

Co de

Running Diagnostics 39

7

Beeper Test Purpose:

Where Available:

You can test the terminal beeper to make sure the entire beep volume range and beep frequency range are available and working correctly. The Beeper Test can also help you distinguish the different beep volumes to choose a level that you can hear in your working environment. Choose the Main Board Menu from the Hardware Diagnostics menu.

Sample Screen:

BEEPER

TEST

SELECT BEEP TEST: (Hold down any key to stop test) 1-Frequency Test 2-Volume Test 3-Club 39 Jam 4-K. 622

[Esc]

Exit

242XU.145

Definition:

Press to test the beep frequency range. The terminal will sound a series of beeps starting from a low frequency beep through the range to a high frequency beep, and then back to a low frequency beep.

Press to test the beep volume. The terminal sounds a series of beeps from a quiet beep to a very loud beep. Tests 3 and 4 also test the beep volume and frequency by playing a short tune. If you do not hear any beeps during any of these tests, you may have a problem with the beeper or internal speakers. For help, contact your local Intermec service representative.

7-11

Page 308

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugg Co de

39

Destructive RAM Test Purpose:

Where Available: Sample Screen:

Use the Destructive RAM Test if you have any problems storing files on the RAM drive or running an application that uses RAM memory. Choose the Main Board Menu from the Hardware Diagnostics menu. DESTRUCTIVE

RAM

TEST

The following test will cause the unit to reboot, causing loss of all RAM resident data.

Memory

Pass

#:

Test

Passed

00037

Press a key to Reboot Unit

PROCEED? PRESS 'Y' to proceed...

[Esc]

Exit

242XU.143

Definition:

Before you run this test, save your data. If you are running a TE application, end your current TE session. Press to start the test. All data in RAM will be lost. The terminal starts the RAM test and clears the screen. You hear a beep after a successful test of each 64K block of data. After 15 beeps, a test pass is complete and the results appear. The sample screen shows a successful test pass.

8

To run another test pass, do not press a key and the next test begins after a 5 second pause. You may let the test continue and test the RAM several times to get a test over time. To exit the test, press once a test pass is complete. The terminal reboots and restarts your application.

If an error is found, the Destructive RAM Test stops and displays the error address, the data written to RAM, and the data read from RAM. Note this information and contact your local Intermec service representative. Caution If the Destructive RAM Test fails, stop using the terminal. Contact your local Intermec service representative. Conseil Si le test Destructive RAM échoue, veuillez ne plus utiliser le terminal. Contactez le représentant du service clientèle Intermec de votre région.

7-12

Page 309

Nugg

Co de

Running Diagnostics 39

7

Display Test Purpose:

Where Available: Sample Screen:

Use the Display Test to make sure that every pixel on the terminal screen is working correctly. For example, you may want to test the screen if you do not see complete characters on the screen. Hardware Diagnostics menu DISPLAY

[Enter] Next [Esc] Exit

TEST pattern

242XU.135

Definition:

Press to display each of the four patterns. After 5 seconds, the entire screen is filled with the current test pattern. Press to display the next pattern. The first two patterns appear as a shaded pattern and turn off every other pixel. The third pattern turns on every pixel and appears as a black square. The fourth pattern turns off every pixel and appears as a clear square.

If any of these patterns do not display correctly, you may have a problem with the LCD. For help, contact your local Intermec service representative.

7-13

Page 310

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugg Co de

39

Hardware Configuration Purpose:

Where Available: Sample Screen:

If you are discussing a problem with Intermec, you can use the Hardware Configuration screen to tell the Intermec representative the exact version of hardware that was installed on the terminal at the Intermec factory. You can also use this screen to see the radio frequency and country code that are configured on the T2425. Hardware Diagnostics menu HARDWARE

CONFIG

HARDWARE

Country Code: America/ASI (80,01)

PCMCIA PCMCIA

Display Display Display

PCB

Keypad Keypad Keypad

Type: Rev.: Cont:

Type : Rev. : Table:

0 0 32

[Enter] Next [Esc] Exit

0 0 0 screen

Type: Rev.:

Rev.

Product

ID

CONFIG 2 1

:

1

:

2420

Serial # : 96080200430

[Enter] Next [Esc] Exit screen

242XU.142

Definition:

Press to display the next screen of hardware information. If you are having a specific problem with one system, such as the radio, note the hardware versions on the terminal before contacting your local Intermec service representative. The country code information on the Hardware Configuration screen is only valid when the radio (Network Activate command) is enabled. If the radio is disabled, the country code information is not valid. For help, see “Network Activate” in Chapter 9. Note: The country code information does not apply to the T2420 since it does not have a radio.

7-14

Page 311

Nugg

Co de

Running Diagnostics 39

7

Keypad Test Purpose:

Where Available:

An application programmer can use the Keypad Test screen to quickly find the hexadecimal key code value, the decimal key code value, and the scan code for any key on the keypad. You can also use the test to make sure the keypad is operating correctly. Hardware Diagnostics menu

Sample Screen:

KEYPAD Key 'a' 'b' 'c' 'd' 'e' 'f' 'g' 'h' 'i' 'j' 'k' 'l'

Hex 61 62 63 64 65 66 67 68 69 6A 6B 6C

[Esc]

Exit

TEST Dec 97 98 99 100 101 102 103 104 105 106 107 108

Scan 1E 30 2E 20 12 21 22 23 17 24 25 26

242XU.133

Definition:

Press any key or key combination on the keypad to display the hexadecimal, decimal, and scan code value of the key. When you press , the terminal pauses for a few seconds to display the values before you exit the screen. For a complete list of key codes, see the “TRAKKER Antares Terminal Font Set” in Appendix C or refer to the TRAKKER Antares Application Development Tools System Manual (Part No. 064433).

?

7-15

Page 312

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugg Co de

39

Radio Test Purpose: Where Available:

Use the Radio Test screen on a T2425 to verify that you have a working radio. Hardware Diagnostics menu

Sample Screen:

RADIO

TEST

Test:

PASSED

[Esc]

Exit

242XU.138

Definition:

Before you start the test, make sure the radio (Network Activate command) is enabled. If the radio is disabled, the test results on the Radio Test screen are not valid. For help, see “Network Activate” in Chapter 9.

Press to start the radio test. The results of the test display on the screen once the test is complete. If SUCCESS or PASSED display, the radio is working correctly. If FAILED displays, note the error number. You may have a problem with the radio inside the T2425. For help, contact your local Intermec service representative. Caution If the Radio Test fails, stop using the terminal. Contact your local Intermec service representative. Conseil Si le test Radio échoue, veuillez ne plus utiliser le terminal. Contactez le représentant du service clientèle Intermec de votre région.

7-16