Page 130

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual nuggetf code39 11. Press to save the changes and exit the Radio screen.

Note: If the terminal is on a different IP subnetwork from the DCS 300 or host, you must also configure the default router and subnet mask. Choose the Advanced Network command to set these parameters. For help, see Chapter 4, “Operating the Terminal in a Network.”

:

12. For TCP/IP networks, press to choose the Advanced Network command and then press . The Advanced Network screen appears.

UDP Plus Advanced Network ADVANCED

NETWORK

Loopback: Disabled Network Port: 05555 Subnet Mask: 255.255.255.0 Default Router: 0.0.0.0 Controllr Connect Chk Send Timer:0035 sec Recv Timer:0060 sec Retries: 07

` more

TCP/IP Advanced Network ADVANCED

NETWORK

Network Port: 00023 Subnet Mask: 255.255.255.0 Default Router: 0.0.0.0 TCP/IP Maximum Transmit Timeout: 020 sec

OK

CANCEL 242XU.181

Note: For UDP Plus networks, the Network Port default is 5555, which matches the default value set on the DCS 300.

V

13. In the Network Port field, type a number from 1 to 65535 and then press . The default value is 23, which enables VT/ANSI Telnet communications. If you are not using Telnet communications, enter the port number used by your application.

? to exit the Communications Menu. The Configuration Menu appears. 15. Press ? to exit the Configuration Menu. 16. Press to choose Yes and save the new configuration in RAM. Once the changes are saved, the terminal uses the new configuration. 17. Press ? to exit the TRAKKER Antares 2400 Menu System.

14. Press

1-28

Page 131

nuggetf

18. Press

Getting Started code39

1 to choose Yes and store your changes permanently in flash memory.

Store configuration changes in flash memory? (used when rebooting the terminal)

Yes

No

CANCEL

242XU.054

19. Press to choose OK and exit the TRAKKER Antares 2400 Menu System. Exiting

TRAKKER Antares 2400 Menu System

OK

CANCEL 242XU.055

The T2425 will try to establish communications with the DCS 300 or the host. For terminal emulation applications in a UDP Plus network, you need to configure the host name in the TE Configuration menu to establish communications. For help, see the TRAKKER Antares Terminal Emulation User’s Guide. Once the terminal connects, the login or initial screen for your application appears and the Connect icon stops blinking. You can begin using the terminal to collect data. Note: While the terminal is connecting to the DCS 300 or host, the terminal ignores any input from the keypad or scanner. Wait until the terminal is connected before you try to enter any data. If the terminal will not connect, see Chapter 6, “Troubleshooting,” or the DCS 300 System Manual.

1-29

Page 132

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual nuggetf code39

Verifying That the T2425 Is Communicating Correctly Once you have configured the terminal, your T2425 is ready for operation. To transmit and receive data, the T2425 must be communicating with the access point and DCS 300 or host. Use these instructions to make sure the T2425 is communicating correctly. To verify that the T2425 is communicating correctly 1. If the terminal is not on, press

L to turn it on.

2. Look at the top line of the terminal’s screen. If the Connect icon (shown in the illustration) appears and remains on solid, the terminal is communicating with the access point. In a UDP Plus network, a solid Connect icon also means that the terminal is communicating with the DCS 300. The terminal can send and receive data to the connected devices.

* 242XU.109

If you are having problems with network communications •

If the Connect icon blinks or is not on, you need to check the network IP addresses and configuration. Make sure the radio domain and radio security ID on the terminal match the values that are set on the access point.

•

If the Radio icon (shown in the illustration) remains on solid, the Network Activate command is disabled, or there is a problem with the radio card and the radio is turned off.

242XU.116

Make sure the Network Activate command is enabled and all the network parameters are set correctly. For help, follow the instructions for “Configuring the T2425 and the RF Network” earlier in this chapter.

1-30

Page 133

nuggetf

Getting Started code39

1

Starting the Application and Using the Terminal Your T2420 ships loaded with a sample application. Your T2425 ships loaded with either the sample application or a terminal emulation application. To start the application and use the terminal

L

1. Press to turn on the terminal. The login or initial screen for your application appears. 2. Check the four application screens shown next in the left column. Find the application screen that matches the one on your terminal. Follow the instructions on the right of the screen to use the terminal. Sample Application Screen 97/01/08

08:10:50 a. Use the sample application to scan bar code labels and test the terminal’s keypad. For help, see Appendix D, “Using the Default Applications.” b. Connect the T2420 to a host computer using the communications dock, the optical link adapter, or the serial interface module. For help, see the accessory documentation.

242XU.167 c. Create custom applications for the terminal using the TRAKKER Antares Programmer’s Software Kit (PSK) or EZBuilder and Microsoft C/C++ functions. d. Download your custom application to the terminal and run it. For help, see Chapter 5, “Using Custom Applications.”

3270/5250 TE Sign-On Screen

* Sign on User.............. Password.......... Program/procedure. Menu.............. Current Library...

a. Configure the terminal emulation application (if necessary). For help, see the TRAKKER Antares Terminal Emulation User’s Guide. b. Login to a terminal emulation session. c. Start using the T2425 to collect and transmit data.

242XU.166

1-31

Page 134

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual nuggetf code39

Step 2: Using the Application (continued) VT/ANSI TE Login Screen a. Configure the terminal emulation application (if necessary). For help, see the TRAKKER Antares Terminal Emulation User’s Guide.

* <login:

b. Log in to a terminal emulation session. c. Start using the T2425 to collect and transmit data. 242XU.163

Turning the Terminal On and Off The terminal’s Suspend/Resume key is the as shown in this illustration.

L

When you press to turn off the terminal, the terminal does not actually shut off, but goes into a Suspend mode. This mode is referred to as “off” in the rest of this manual. In Suspend mode, the terminal continues to power all memory and turns off the power to most of the hardware.

L

L key in the upper left corner of the keypad, Suspend/ Resume key I/O Enter

F6

F7

Enter

F8

F10 F9

F1 F5 When you press to turn on the F2 F4 F3 terminal, the terminal either resumes exactly where it was when you turned it 242XU.045 off, or the terminal boots and restarts your application. Resume is controlled through a parameter or command called Resume Execution. By default, the terminal restarts your application. For help, see “Resume Execution” in Chapter 9.

If you change the main battery pack while the terminal is turned off, the terminal resumes or boots the next time the terminal is turned on. The backup battery saves all memory while you change the main battery pack.

1-32

Page 135

nuggetf

Getting Started code39

1

Enabling Bar Code Symbologies The terminal can decode several different types of bar code symbologies. Each symbology, such as Code 39, uses a different scheme for encoding data as bar code. You must configure the terminal to decode the bar code symbology used in your bar code labels. Only enable the bar code symbologies that you need to scan. For more information about each symbology and the configuration options, see Chapter 9, “Configuration Command Reference.” The terminal can decode the bar code symbologies shown in the next table. You can scan the bar code labels in the table to enable a symbology. Note: Only three symbologies, Code 39, Code 128, and UPC/EAN, are enabled when you unpack the terminal. Bar Code Symbology

Enabled?

To Enable the Symbology

Codabar

No

Enable Standard Codabar, ABCD Start/Stop Code

*$+CD21* *$+CD21* Code 11

No

Enable Code 11 With Two Check Digits

*$+CG2* *$+CG2* Code 16K

No

Enable Standard Code 16K

*$+CP1* *$+CP1* Code 2 of 5

No

Enable Code 2 of 5, 3 Bar Start/Stop, Label Length of 1

*$+CC001* *$+CC001* Interleaved 2 of 5 (I 2 of 5)

No

Enable I 2 of 5, Variable Length With a Check Digit

*$+CA99* *$+CA99*

Note: You can enable either Code 2 of 5 or Interleaved 2 of 5. If you enable I 2 of 5, Code 2 of 5 is automatically disabled and vice versa.

1-33

Page 136

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual nuggetf code39

Bar Code Symbology Table (continued) Bar Code Symbology

Enabled?

To Enable the Symbology

Code 39

YES

Enable Code 39 Full ASCII With No Check Digit

*$+CB111* *$+CB111* Code 49

No

Enable Code 49

*$+CJ1* *$+CJ1* Code 93

No

Enable Code 93

*$+CF1* *$+CF1* Code 128

YES

Enable Standard Code 128

*$+CH1* *$+CH1* MSI

No

Enable MSI Without Check Digits

*$+CN10* *$+CN10* Plessey

No

Enable Plessey With Reverse Start Code

*$+CI10* *$+CI10* UPC/EAN

YES

Enable UPC-A/EAN-13, UPC-E, EAN-8

*$+CE1111111* *$+CE1111111*

1-34

Page 137

nuggetf

Getting Started code39

1

What’s New on the TRAKKER Antares Terminals The firmware on the terminals has been updated and expanded. These new features for the terminals were added in the v5.X firmware release: •

Information is included about usng the APPTSK.BIN and EM9560.BIN applications that are preloaded on the terminals. The EM9560.BIN application leets you emulate specific features that are available on Intermec 95XX terminals. For help, see Appendix D, “Using the Default Applications.”

•

You now use a programmable terminal instead of a screen mapping terminal to do screen mapping with the host through the DCS 300.

•

Information is included about using the serial interface module for COM4.

•

Information is included about using the modem for COM3.

•

XON/XOFF is allowed in Frame mode. For help, see “Flow Control” in Chapter 9.

•

New Set Time and Date reader command for 95XX terminal compatibility. For help, see “Set Time and Date” in Chapter 8.

Where Do You Go From Here? Now that your new terminal is working, you can use this manual to learn how to perform these tasks: Task or Feature

See This Chapter

To learn how to use the terminal’s keypad, screen, audio signals, batteries, and scan module

Chapter 2, “Learning How to Use the Terminal”

To learn how to change the terminal’s configuration

Chapter 3, “Configuring the Terminal”

To add the terminal to your Intermec 2.4 GHz RF network or wired data collection system and learn how to communicate with other devices

Chapter 4, “Operating the Terminal in a Network”

To learn how to download and run custom applications on your programmable terminal

Chapter 5, “Using Custom Applications”

To learn how to reset the terminal, solve problems, and respond to error messages

Chapter 6, “Troubleshooting”

To learn how to run diagnostics and check the battery power remaining

Chapter 7, “Running Diagnostics”

1-35

Page 138

1-36