The text of a manual · part 17 of 64
Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual: Chapter 1 - Getting Started, pages 121 to 129
Pages 121 to 129 of 558, from Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual
The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2420 and Intermec 2425
Page 121
nuggetf
Getting Started code39
1
Configuring the Serial Port Parameters You use the terminal’s serial port and a communications dock, optical link adapter, or serial interface module to transfer data in a wired network between the terminal and a host computer, printer, or other RS-232 serial device. If your T2420 has a modem, you can send files and data over a phone connection. To power supply
Host computer
Terminal in TD2400 communications dock
242XU.160
You need to set these serial port parameters to have the terminal communicate with a host computer or serial device in a wired network: Serial Port Parameter
Default Value
Baud rate
19200
Data bits
7
EOM (End of Message)
\x03 (hexadecimal value for ETX)
Flow control
None
Handshake
Disabled
LRC
Disabled
Modem dial sequence (COM3 only)
No dial sequence
Modem initialization sequence (COM3 only)
Auto rate
Parity
Even
Poll (Polling)
Disabled
Serial port protocol
Configurable
SOM (Start of Message)
\x02 (hexadecimal value for STX)
Stop bits
1
Timeout delay
10 seconds
1-19
Page 122
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual nuggetf code39 The values you set for the terminal’s serial port must match the values set for the host’s (or other device’s) serial port. You use the TRAKKER Antares 2400 Menu System to set the parameters on the terminal. For a detailed definition of these parameters, see Chapter 9, “Configuration Command Reference.” To set the serial port parameters
: V
1. From the Main Menu, press or to choose the Configuration Menu and then press . The Configuration Menu appears.
Note: If you are not in the TRAKKER Antares 2400 Menu System, press or press to access the Main Menu.
T3 ,
T
CONFIGURATION MENU Symbologies Menu Communications Menu Terminal Menu
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.010
V
2. Press to choose the Communications Menu and then press Communications Menu appears. T2425 Communications Menu COMMUNICATIONS
The
T2420 Communications Menu
MENU
COMMUNICATIONS
Primary Network Advanced Network Radio Serial Port [COM1] Serial Port [COM4]
Serial Serial
Port Port
MENU
[COM1] [COM4]
⁄ ⁄
_` Select item [Enter] Next screen [F1] Help [Esc] Exit
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.070
1-20
Page 123
nuggetf
3. Press
Getting Started code39
1
V to choose Serial Port and then press The Serial Port screen appears.
SERIAL PORT [COM1] Flow Control: None EOM #1: \X03 EOM #2: SOM: \X02 LRC: Disabled Commands Vic Serial Port:Enabled No TMF Handshake: Disabled
Protocol: Configurable Baud Rate: 19200 Parity: Even Data Bits: 7 Stop Bits: 1
OK
CANCEL
` more 242XU.156
W
242XU.157
4. In each field, press to toggle through the field options and select a value. Once the correct value is displayed, press to move to the next field.
V
You must set each of the terminal’s serial port parameters to match your host computer’s or serial device’s settings. Once they match, you can communicate through the communications dock or optical link adapter.
6. Press ? to exit the Communications Menu. The Configuration Menu appears. 7. Press ? to exit the Configuration Menu. 8. Press to choose Yes and save the new configuration in RAM. Once the changes 5. Press to save the changes and exit the Serial Port screen. The Communications Menu appears.
are saved, the terminal uses the new configuration.
Save new configuration (in
RAM)?
Yes
No
CANCEL
242XU.059
9. Press
? to exit the TRAKKER Antares 2400 Menu System.
1-21
Page 124
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual nuggetf code39 10. Press to choose Yes and store your changes permanently in flash memory.
Store configuration changes in flash memory? (used when rebooting the terminal)
Yes
No
CANCEL
242XU.054
11. Press to choose OK and exit the TRAKKER Antares 2400 Menu System. Exiting
TRAKKER Antares 2400 Menu System
OK
CANCEL 242XU.055
12. If you have a T2420, continue with the section on “Starting the Application and Using the Terminal” later in this chapter. If you have a T2425, continue with the next section, “Configuring the T2425 and the RF Network.”
1-22
Page 125
nuggetf
Getting Started code39
1
Configuring the T2425 and the RF Network The T2425 can communicate with a host computer in Intermec’s 2.4 GHz RF network either through the access points and the DCS 300 or directly through the access points. The terminal ships with one of these RF network protocol options: •
UDP Plus
•
TCP/IP
In a UDP Plus network, the terminal communicates through the DCS 300 to a host on an Ethernet, token ring, twinaxial, coaxial, or SDLC network. In a TCP/IP network, the terminal communicates through the access point directly to a host on an Ethernet or token ring network. Host
TCP/IP Direct Connect
UDP Plus
Ethernet
DCS 300 Access point
T2425
Access point
T2425 242XU.193
Note: All devices in the 2.4 GHz RF network must have an IP address. All access points that the T2425 may communicate with must be in the same IP subnetwork. For help, see Chapter 4, “Operating the Terminal in a Network.”
1-23
Page 126
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual nuggetf code39 To use RF communications on the T2425, you need to: 1. Configure the DCS 300 (UDP Plus) or host (TCP/IP). 2. Configure the access point. 3. Configure the network parameters on the terminal. Each step is described in the next sections. Caution Make sure all components with antennas are at least 1 feet (30 centimeters) apart when power is applied. Failure to comply could result in equipment damage. Conseil Assurez-vous que la distance entre tous les éléments avec antennes soit d'au moins un pied (centimètres) avant de faire la connexion avec l'alimentation électrique, faute de quoi vous risquez d'endommager votre installation.
Configuring the DCS 300, Host, and Access Points To use your T2425 in Intermec’s UDP Plus network, you must first install and configure the DCS 300 and the access points. For help, see the DCS 300 System Manual and your access point user’s manual. To use your T2425 in a TCP/IP direct connect network, you must first install and configure the access points. For help, see your access point user’s manual. You must also set up your host to communicate with the devices in the RF network. Note: You can use a T2425 communicating using UDP Plus and the DCS 300 in a pass-through network. You establish a direct TCP/IP socket connection from the T2425 to the host through the server. For more information, see the DCS 300 System Manual.
Configuring the T2425 Network Parameters You need to set these network parameters to begin using RF communications:
UDP Plus Network Parameters
1-24
Network Parameter
Default Value
Network activate
Disabled
Controller IP address
0.0.0.0
Terminal IP address
0.0.0.0
RF domain
0
RF security identification (ID)
None (not set)
Page 127
nuggetf
Getting Started code39
1
TCP/IP Network Parameters Network Parameter
Default Value
Network activate
Disabled
Host IP address
0.0.0.0
Terminal IP address
0.0.0.0
Network Port
23
RF domain
0
RF security identification (ID)
None (not set)
You use the TRAKKER Antares 2400 Menu System to set these parameters. For a detailed definition of these parameters, see Chapter 4, “Operating the Terminal in a Network.” Note: If the terminal is on a different IP subnetwork from the DCS 300 or host, you must also configure the default router and subnet mask. For help, see Chapter 4, “Operating the Terminal in a Network.” To set the network parameters
: V
1. From the Main Menu, press or to choose the Configuration Menu and then press . The Configuration Menu appears.
Note: If you are not in the TRAKKER Antares 2400 Menu System, press or press to access the Main Menu.
T3 ,
T
CONFIGURATION MENU Symbologies Menu Communications Menu Terminal Menu
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.010
1-25
Page 128
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual nuggetf code39
V
2. Press to choose the Communications Menu and then press Communications Menu appears. COMMUNICATIONS
The
MENU
Primary Network Advanced Network Radio Serial Port [COM1] Serial Port [COM4]
⁄ _` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.011
3. Press to choose the Primary Network command. The Primary Network screen appears. UDP Plus Primary Network PRIMARY
NETWORK
Activate: Disabled Controller IP Addr: 0.0.0.0 Terminal IP Address: 0.0.0.0
OK
TCP/IP Primary Network
CANCEL
PRIMARY
NETWORK
Activate: Disabled Host IP Addr: 0.0.0.0 Terminal IP Address: 0.0.0.0
OK
CANCEL 242XU.186
W
4. In the Activate field, press to toggle the field and display the 2.4 GHz RF option and activate radio frequency network communications. Press to move to the next field.
V
5. In a UDP Plus network, you set the Controller IP Address. In a TCP/IP network, you set the Host IP Address. In the Controller IP Address or the Host IP Address field, type in the IP address for the DCS 300 or host in your network. The address field consists of four separate numbers. Each number in the field is separated by a period and can be a number from 0 to 255. Type the address in the format nnn.nnn.nnn.nnn and then press .
V
1-26
Page 129
nuggetf
Getting Started code39
1
For example, if your DCS 300 or host IP address is 192.100.100.2, type:
Note: The network cannot be activated if the first address segment in the IP address is set to 0, 127, or a number greater than 223. 6. In the Terminal IP Address field, type in the terminal’s IP address. The IP address must match the address that is set for the terminal on the DCS 300 or host. The address field consists of four separate numbers. Each number in the field is separated by a period and can be a number from 0 to 255. Type the address in the format nnn.nnn.nnn.nnn and then press .
V
For example, if your terminal IP address is 192.100.100.3, type:
Note: The network cannot be activated if the first address segment in the IP address is set to 0, 127, or a number greater than 223.
to save the changes and exit the Primary Network screen. 8. Press V to choose the Radio command and then press The Radio screen 7. Press appears.
UDP Plus and TCP/IP Radio RADIO Domain: 00 Security ID: (ID unchanged) Wakeup on Broadcast: No Roam Flag: Allowed Transmit Mode: BFSK Inactivity Timeout: 5 sec OK
CANCEL 242XU.120
V. The domain must 10. In the Security ID field, type the RF security identification and then press V. The 9. In the Domain field, type a number from 0 to 15 and then press match the number set on the access point.
Security ID is case-sensitive and can be up to 20 characters long. It must match the security ID set on the access point.
Note: If you have not changed the Security ID in the current session, the words (ID unchanged) display instead of the actual password. If you change the Security ID, you see the actual password until you save the changes.
1-27