Page 80
Chapter 4 - Troubleshooting and Maintenance nugget
39 AGaramond
Problems While Configuring 802.1x Security (continued) Problem The terminal indicates that it is not authenticated by emitting a high beep and a low beep. This error code appears on the Error Logger screen: 0x513
Possible Solution The root Certificate Authority certificate on your terminal cannot validate the server certificate.
• Make sure your Odyssey server is using a server certificate that matches the root certificate loaded on your terminal.
• Verify the root certificate in the CACERT.PEM file on your terminal’s C drive. For help, see the documentation that shipped with your Odyssey server software.
The terminal indicates that it is not authenticated by emitting a high beep and a low beep.
Neither of the server certificate common names configured on your terminal match the server certificate common name in the active server certificate on your Odyssey server.
This error code appears on the Error Logger screen: 0x542
• Delete both server certificate common names on your terminal to see if you can authenticate without checking the server certificate common name.
• Change one or both server certificate common names on your terminal so that they match the server certificate common names in the active server certificate on your Odyssey server. For help, see “Server Certificate Common Name” in Chapter 6 of the 2400 Family system manual.
Problems With RF Connectivity (2415 only) If the 2415 is not communicating with other devices in the RF network, check these possible solutions. Problems With RF Connectivity Problem You are having problems with your 802.11b RF network coverage.
Solution Make sure that the Medium Density Distribution (MDD) command on your access point is not enabled. When MDD is enabled, the access point distributes values for these RF coverage parameters to your terminal: AP Density, Medium Reservation, and Microwave Robustness. Changes made by your access point are not reflected in the terminal menu system.
When you turn on the terminal after it was suspended for awhile (10-15 minutes or longer), the terminal can no longer send or receive messages over the network.
The host may have deactivated or lost your current terminal emulation session. In a TCP/IP direct connect network, you need to turn off the “Keep Alive” message (if possible) from the host so that the TCP session is maintained while a terminal is suspended.
You are sending and receiving information through the network, and the terminal appears to be operating slowly.
The terminal may be configured for the 5x6, 6x8, or 12x16 font type. These font type values may cause the 241X to scroll, and therefore operate, more slowly when it displays information on the screen. Change the font type to a value other than 5x6, 6x8, or 12x16. For help, see “Display Font Type” or “Display Spacing” in Chapter 6 of the 2400 Family system manual. If the terminal continues to operate slowly, contact your local Intermec service representative for help.
66
Trakker Antares 241X Handheld Terminal User’s Manual
Page 81
nugget
39 AGaramond Chapter 4 - Troubleshooting and Maintenance
Problems With RF Connectivity (continued) Problem The Connect LED is off. The 2415 is not communicating with the access point.
Solution The 2415 is not connected to the access point. Make sure the access point is turned on and operating. You may also be using the terminal out of range of an access point. Try moving closer to an access point to re-establish communications. If you are using a MobileLAN™ access point with software release 1.34 or earlier, it may not be able to communicate with the terminal. For help upgrading your access point software, see the MobileLAN access System Manual (P/N 067150). Make sure the Network Activate command is enabled. For help, see “Network Activate” in Chapter 6 of the 2400 Family system manual. Make sure the 2415 is configured correctly for your network. The radio parameters on the terminal must match the values set for all access points the terminal may communicate with. For help, see “Using RF Communications on the 2415” on page 48. If you have an 802.11b radio, the radio initialization process may have failed. Try resetting the terminal. see “Booting and Resetting the Terminal” on page 71. If you have tried these possible solutions and the Connect LED is still off, you may have a defective radio card. For help, contact your local Intermec service representative.
The 2415 is connected to the Intermec Gateway, DCS 30X, or host computer and you move to a new site to collect data. The Connect LED was on and now begins to blink or turns off.
You may have gone out of range of an access point. Try moving closer to an access point or to a different location to re-establish communications. Once you are in range again, the Connect LED will turn on. Any data you collected while out of range will be transmitted over the network.
The Connect LED is on, but you cannot establish a terminal emulation session with the host computer.
There may be a problem with the host computer, a problem with the connection between the Intermec Gateway or DCS 30X and the host computer, or a problem with the connection between the access point and the host computer. Check with your network administrator to make sure the host is running and allowing users to login to the system.
The Connect LED blinks.
In a UDP Plus or WTP network, the terminal is communicating with an access point, but it is not connected to the Intermec Gateway or DCS 30X. You may need to check the 2415 configuration, or make sure the Intermec Gateway or DCS 30X is running and that data collection is started. Each device in the RF network must have a valid IP address. The IP addresses set on the terminal must match the addresses configured on the Intermec Gateway, DCS 30X, or host. For help, see “Using RF Communications on the 2415” on page 48.
The Connect LED is on, but the host computer is not receiving any data from the 2415.
In a UDP Plus or WTP network, there may be a problem with the connection between the Intermec Gateway or DCS 30X and the host computer. Check with your network administrator or see the documentation that shipped with the Intermec Gateway or the user’s manual for the DCS 30X. In a TCP/IP network, there may be a problem with the connection between the access point and the host computer. Check with your network administrator or use your access point user’s manual.
Trakker Antares 241X Handheld Terminal User’s Manual
67
Page 82
Chapter 4 - Troubleshooting and Maintenance nugget
39 AGaramond
Problems While Running Applications If you are running applications on the terminal and have trouble, check these possible problems and solutions. Problems While Running Applications Problem The Connect LED blinks and you see this message: Unable to connect to controller. Error 102. Unable to establish connection to host. Session ended.
You see one of these error messages while running a PSK or EZBuilder application: SCREEN ERROR: 30 Code: 9 Hit any key To exit! SCREEN ERROR: 31 Code: 3 Hit any key To exit! You see this error message when trying to load a program: ERROR LOADING MODULE LIBRARY NAME: <libraryname>
Solution The 2415 is connected to the access point, but is trying to establish communications with the Intermec Gateway or DCS 30X and the host computer. Make sure the terminal is correctly configured for your network. In a UDP Plus or WTP network, make sure the Intermec Gateway or DCS 30X is configured and data collection is started. In a TCP/IP network, make sure the host computer is configured and running. If you have configured the network correctly, try shutting down and restarting the Intermec Gateway or DCS 30X to establish communications. You can also try resetting the terminal. For help resetting the terminal, see “Booting and Resetting the Terminal” on page 71. You must set the RAM Drive Size configuration command. For help, see “RAM Drive Size” in Chapter 6 of the 2400 Family system manual.
You need to free conventional memory by removing files or applications from Drive C. For help, see “Delete File” in Chapter 5 of the 2400 Family system manual.
FILENAME: <filename> where libraryname and filename are the library and file names of the program. A DOS command does not work.
The command is invalid. For a list of valid DOS commands, see “Using ROM-DOS Commands” in Appendix D of the 2400 Family system manual.
You try to run a DOS application in the TRAKKER Antares 2400 Menu System and see this message: Not a valid application.
You tried to run a DOS .EXE application from the TRAKKER Antares 2400 Menu System. You can only run .BIN applications in the menu system. To run a DOS .EXE application, enter the filename at the DOS prompt. For help, see “Running DOS Applications and Using ROM-DOS Commands” in Appendix D of the 2400 Family system manual.
The terminal does not boot after you modified the CONFIG.SYS file to configure a ROM-DOS drive.
Correct the error in CONFIG.SYS and use the DOS software tools to recreate Drive A with the corrected CONFIG.SYS file.
68
Trakker Antares 241X Handheld Terminal User’s Manual
Page 83
nugget
39 AGaramond Chapter 4 - Troubleshooting and Maintenance
Problems Transmitting Data Through the Serial Port If you are having problems sending or receiving data through the integrated I/O port on the terminal, check these possible problems: • Make sure the terminal is connected to the PC, host computer, or RS232 serial device using the appropriate cable. • If the terminal is in a communications dock, make sure that the communications dock is connected to the serial device using the appropriate cable. • Make sure the terminal’s serial port parameters are configured to match the serial port configuration on the PC, host computer, or serial device. For help, see “Using Serial Communications on the Terminal” on page 44.
Problems Transmitting Data Through the Intermec Gateway or DCS 30X If you have a problem while running the application on the terminal in a UDP Plus or WTP network, check these possible communications problems. Problems Transmitting Data Through the Intermec Gateway or DCS 30X Problem Transaction Buffer Full.
Solution The buffer holding transactions to be sent to the Intermec Gateway or DCS 30X is full. Stop collecting data with this terminal. Make sure the terminal is communicating with the Intermec Gateway or DCS 30X and let the terminal send all the transactions in the buffer before you continue collecting data.
Sending Buffer Transactions.
This is an information message to tell you that buffered transactions are now being sent to the Intermec Gateway or DCS 30X. You can begin collecting data again once the message clears.
Transaction Aborted.
The transaction just sent to the Intermec Gateway or DCS 30X was not received. Try sending the transaction again.
Transmit Error XX, press Enter.
There is an error transmitting data to the Intermec Gateway or DCS 30X. XX represents the status code error. Note the error code listed in the message and contact your local Intermec service representative for help. Press \ to continue.
Receive Error XX, press Enter.
There is an error receiving data from the Intermec Gateway or DCS 30X. XX represents the status code error. Note the error code listed in the message and contact your local Intermec service representative for help. Press \ to continue.
Shutting down.
The Intermec Gateway or DCS 30X is shutting down. You may continue collecting data and buffer the transactions in the terminal until the Intermec Gateway or DCS 30X starts again, or stop collecting data with the terminal.
Controller Shutdown.
The Intermec Gateway or DCS 30X has shut down. You may continue collecting data and buffer the transactions in the terminal until the Intermec Gateway or DCS 30X starts again, or stop collecting data with the terminal.
Trakker Antares 241X Handheld Terminal User’s Manual
69
Page 84
Chapter 4 - Troubleshooting and Maintenance nugget
39 AGaramond
Problems While Scanning Bar Codes If you cannot scan bar code labels or you are having trouble with the scan module, check these possible problems. Problems While Scanning Bar Codes Problem You cannot see a red beam of light from the scanner when you press the Scan button and aim the scanner at a bar code label.
Solution There are two possible problems:
• You may be too far away from the bar code label. Try moving closer to the bar code label and scan it again.
• You may be scanning the bar code label “straight on.” Change the scanning angle and try again. You can test the effective range of the scanner. Move within 0.6 meters (2 feet) of a wall and test the scanner. You need to be within the scanning range to scan bar code labels. For help on scanning distances, see “Specifications” in Appendix A. When you release the Scan button, the Good Read LED does not turn off.
The Good Read LED will remain on if you configure the terminal to use edge triggering. If you configure the terminal for level triggering and the Good Read LED remains on, there may be a problem. Press the Scan button again without scanning a bar code label. If the LED is still on, contact your local Intermec service representative.
You have an input device attached to the terminal and it cannot read any bar codes.
You may not be using an input device that is supported with the terminal. Make sure you are using one of the supported input devices.
The input device attached to the terminal does not appear to work well or read bar code labels very quickly.
Try setting the Scanner Selection command to the specific input device you have attached. Check the bar code symbologies you have enabled on the terminal. Enable only the symbologies you are using.
The scanner will not read the bar code label.
If you are using the advanced long-range scanner, you may not be able to scan the bar codes in this manual. However, you can still send commands through the serial port or network. For help, see Chapter 2, “Configuring and Managing the Terminals,” in the 2400 Family system manual. Make sure you aim the scanner beam so it crosses the entire bar code label in one pass. The angle you are scanning the bar code label may not be working well, or you may be scanning the label “straight on.” Try scanning the bar code label again, but vary the scanning angle. The bar code label print quality may be poor or unreadable. To check the quality of the bar code label, try scanning a bar code label that you know scans. Compare the two bar code labels to see if the bar code quality is too low. You may need to replace the label that you cannot scan. Make sure the bar code symbology you are scanning is enabled. Use the TRAKKER Antares 2400 Menu System to check the symbologies. On the Symbologies Menu, each symbology that is enabled has an asterisk (*) next to the name of the symbology. If your bar code symbology is disabled, enable it and then try scanning the bar code label again. Make sure that the application you are running on the terminal is expecting input from a bar code. You may need to type this information instead of scanning it.
70
Trakker Antares 241X Handheld Terminal User’s Manual
Page 85
nugget
39 AGaramond Chapter 4 - Troubleshooting and Maintenance
Problems While Scanning Bar Codes (continued) Problem You scan a reader command, such as Backlight On, and nothing happens.
Solution The reader commands are disabled. Scan the Enable Override command shown here to temporarily enable all of the reader commands. You can also enable or disable reader commands with the TRAKKER Antares 2400 Menu System. For help, see “Command Processing” in Chapter 6 of the 2400 Family system manual. When you are finished, remember to disable the override so that your data is not interpreted as a command. Enable Override
*$+DC3* *$+DC3* The scanner does not read the bar code labels quickly, or the scanning beam seems to be faint or obscured.
The scanner window may be dirty. Clean the window with a solution of ammonia and water. Wipe dry. Do not allow abrasive material to touch the window.
You scan a valid bar code label to enter data for your application. The data decoded by the scan module does not match the data encoded in the bar code label.
The terminal may have decoded the bar code label in a symbology other than the label’s actual symbology. Try scanning the bar code label again. Make sure you scan the entire label. To operate the terminal quickly and efficiently, you should enable only the bar code symbologies that you are going to scan. If you enable multiple symbologies, the terminal may on rare occasions decode a bar code according to the wrong symbology and produce erroneous results.
Booting and Resetting the Terminal You seldom need to boot or reset the terminal. When you boot the terminal, it runs through power-on self test (POST) to test each major subsystem. The terminal uses the configuration currently saved in flash memory. Once the terminal is finished booting, your application appears on the screen. You only need to reset the terminal when the terminal or an application is locked up and will not respond. The terminal also boots and resets after a firmware upgrade or if you remove the battery pack for more than 15 minutes and the backup power source runs out. The next instructions explain how you boot and reset the terminal.
Booting the Terminal You can boot the terminal using these two methods: • Configure the _ key to boot the terminal when you turn on the terminal. • Use the Boot Menu.
Trakker Antares 241X Handheld Terminal User’s Manual
71
Page 86
Chapter 4 - Troubleshooting and Maintenance nugget
39 AGaramond
Booting the Terminal on Resume When you press _ to turn off the terminal, it turns off and goes into Suspend mode. When you press _ to turn on the terminal, it resumes or boots depending on the terminal configuration. There are two ways to configure the _ key using the Resume Execution configuration command: • Resume Execution Not Allowed configures the terminal to boot and restart your application each time you press _ to turn on the terminal. Use this option if you want to restart your application every time you turn on the terminal. • Resume Execution Allowed configures the terminal to resume exactly where it was when you turned off the terminal. Use this option to resume working each time you turn on the terminal. You can configure the Resume Execution command by using the TRAKKER Antares 2400 Menu System or by scanning these bar code labels. For help, see “Resume Execution” in Chapter 6 of the 2400 Family system manual. Resume Execution Not Allowed
*$+ER0*
Resume Execution Allowed
*$+ER1*
*$+ER0*
*$+ER1*
Using the Boot Menu To access the Boot menu you can: • reset the terminal. • remove the battery pack and wait longer than 15 minutes to install a charged battery pack. This procedure also performs a destructive reset, which can have unpredictable results. • upgrade the firmware. For help, see “Upgrading the Firmware” in Chapter 2 of the 2400 Family system manual. BOOT
MENU
1
-
Boot
2
-
Run
3
-
Power
POWER
DOWN
System Loader
IN
Down
60
SEC 241XU058.eps
Boot Menu
The next table describes the Boot Menu options. 72
Trakker Antares 241X Handheld Terminal User’s Manual
Page 87
nugget
39 AGaramond Chapter 4 - Troubleshooting and Maintenance
Boot Menu Options Option Boot System
Description If you did remove the batteries, make sure you install a charged main battery pack or the terminal will not turn on. Press 1 to boot the terminal. Once the terminal is finished booting, your application appears on the screen.
Run Loader
Press 2 to load the terminal firmware. To upgrade or load the firmware, you should use the Firmware Upgrade option in the TRAKKER Antares 2400 Menu System. For help, see “Upgrading the Firmware” in Chapter 2 of the 2400 Family system manual.
Power Down
Press 3 to turn off the terminal. When you turn on the terminal, the Boot Menu screen appears again if POST passes.
Resetting the Terminal If the terminal or application is locked up, try the following steps in order: To reset the terminal • Scan the Boot Terminal bar code to reset the terminal. Boot Terminal
*-.1*
*-.1*
If the terminal will not scan the Boot Terminal bar code, try a warm boot to reset the terminal as described next. To warm boot the terminal 1 Press _ to turn off the terminal. Press _ to turn on the terminal. 2 Use the TRAKKER Antares 2400 Menu System to reboot the terminal. a Press ( \ 2 4 8 to enter the TRAKKER Antares 2400 Menu
System. b Choose System Menu and then Upgrade Firmware. c Choose OK, then YES, then press %. The Boot Menu appears. d Press 1 to boot the terminal.
3 Scan the Reset Firmware bar code to restart the firmware and application. Reset Firmware
*-.*
*-.*
If the terminal or application still will not respond, perform a cold boot to reset the terminal.
Trakker Antares 241X Handheld Terminal User’s Manual
73
Page 88
Chapter 4 - Troubleshooting and Maintenance nugget
39 AGaramond
To cold boot the terminal 1 If possible, press _ to turn off the terminal. 2 Press and hold the _ key for approximately 12 seconds. The Good Read LED blinks once and the terminal turns off. 3 Press _ to turn on the terminal. The Boot Menu appears. 4 Press 1 to boot the terminal. Once the terminal has finished booting, your application appears. 5 Set the time and date. For help using the TRAKKER Antares 2400 Menu System, see “Configuring the Terminal With the Menu System” on page 27.
Cleaning the Scanner Window and Terminal Screen There are no user-serviceable parts inside the terminal. Opening the unit will void the warranty and may cause damage to the internal components. Attention: La terminal ne contient pas de pièces révisibles par l’utilisateur. Le fait d’ouvrir l’unité annule la garantie et peut endommager les pièces internes. To keep the terminal in good working order, you may need to perform these minor maintenance tasks: • Clean the scanner window. • Clean the terminal screen. Clean the scanner window and terminal screen as often as needed for the environment in which you are using the terminal. To clean the scanner window and terminal screen 1 Press _ to turn off the terminal. 2 Use a solution of ammonia and water. 3 Dip a clean towel or rag in the ammonia solution and wring out the excess solution. Wipe off the scanner window and terminal screen. Do not allow any abrasive material to touch these surfaces. 4 Wipe dry.
74
Trakker Antares 241X Handheld Terminal User’s Manual