Page 71
4
Troubleshooting and Maintenance
This chapter explains how to solve problems while using the terminals. You will also find information on booting and resetting the terminals and keeping the scanner window clean. This chapter covers these topics: • Problems and solutions • Booting and resetting the terminal • Cleaning the scanner window and terminal screen
Trakker Antares 241X Handheld Terminal User’s Manual
57
Page 72
Chapter 4 - Troubleshooting and Maintenance nugget
39 AGaramond
Problems and Solutions If you have any problems using the 241X, look in this chapter to find a possible solution. This chapter consists of the following sections: Sections
Page
Problems While Operating the Terminal
58
Problems While Configuring the Terminal
60
Problems While Configuring 802.1x Security
64
Problems With RF Connectivity (2415 only)
66
Problems While Running Applications
68
Problems Transmitting Data Through the Serial Port
69
Problems Transmitting Data Through the Intermec Gateway or DCS 30X
69
Problems While Scanning Bar Codes
70
Booting and Resetting the Terminal
71
Cleaning the Scanner Window and Terminal Screen
74
You can also use the error numbers and messages table and the terminal diagnostics to help analyze and solve problems. For help, see Chapter 4, “Running Diagnostics,” in the Trakker Antares 2400 Family System Manual (P/N 071389). If you have problems with the TE 2000 terminal emulation applications, see the appropriate TE 2000 guide. If you send the terminal in for service, it is your responsibility to save the terminal data and configuration. Intermec is responsible only for ensuring that the keypad and other hardware features match the original configuration when repairing or replacing your terminal.
Problems While Operating the Terminal If you are operating the terminal and have trouble, check these possible problems and solutions. Problems While Operating the Terminal Problem You press _ to turn on the terminal and nothing happens.
Solution Make sure a charged battery pack is installed correctly on the 241X. For help, see “Charging and Installing the Battery Pack” on page 8. The battery pack may be discharged. Replace the battery pack with a spare charged battery pack, or charge the battery pack and try again.
58
Trakker Antares 241X Handheld Terminal User’s Manual
Page 73
nugget
39 AGaramond Chapter 4 - Troubleshooting and Maintenance
Problems While Operating the Terminal (continued) Problem The Battery LED is on and the terminal beeps once every 15 seconds.
Solution The battery pack charge is low. You have a few minutes of power left. Replace the battery pack with a spare charged battery pack, or charge the battery pack.
The terminal is booting and you see a message that POST failed.
The screen displays the system that failed POST. Report the error message to your supervisor. Press % to exit the error message. The Boot Menu appears. Press 1 to boot the terminal. Your application appears on the screen. If the terminal still will not boot, contact your local Intermec service representative for help.
The terminal displays the Boot Menu.
You remove the battery pack and do not replace it within 15 minutes. Once you replace the battery pack and turn on the terminal, the Boot Menu appears. Press 1 to boot the terminal and continue working. For help on the Boot Menu, see “Booting and Resetting the Terminal” on page 71.
The terminal appears to be locked up and you cannot enter data.
Try these possible solutions:
• Scan a bar code label to see if the terminal responds. • Press _ to turn off the terminal. If it turns off, press _ to turn on the terminal. You can continue working.
• If the terminal will not turn off, reset the terminal. Press and hold _ for approximately 12 seconds to reset the terminal. The Good Read LED blinks once and the terminal turns off. Press _ to turn on the terminal. The terminal boots all the systems, clears RAM memory, and starts the application.
• Remove the battery pack. Let the terminal sit for 1 minute. Install the battery pack. Press _ to turn on the terminal.
• (2415 only) Wait at least 10 seconds and try again. If the 2415 is still connecting to the Intermec Gateway or DCS 30X or the host, it ignores any input from the keypad or scanner. Make sure the Connect LED is on before continuing.
• If you keep returning to the Boot Menu, try reloading the firmware. For help, see “Upgrading the Firmware” in Chapter 2 of the 2400 Family system manual.
• If the terminal will not boot or reset, contact your local Intermec service representative for help. You are sending and receiving information through the network, and the terminal appears to be operating slowly.
The terminal may be configured for the 5x6, 6x8, or 12x16 font type. These font type values may cause the 241X to scroll, and therefore operate, more slowly when it displays information on the screen. Change the font type to a value other than 5x6, 6x8, or 12x16. For help, see “Display Font Type” or “Display Spacing” in Chapter 6 of the 2400 Family system manual. If the terminal continues to operate slowly, contact your local Intermec service representative for help.
Trakker Antares 241X Handheld Terminal User’s Manual
59
Page 74
Chapter 4 - Troubleshooting and Maintenance nugget
39 AGaramond
Problems While Configuring the Terminal If you have problems configuring the terminal, check these possible problems and solutions. Problems While Configuring the Terminal Problem You are configuring the serial port and see this error message when exiting the Configuration Menu:
Solution You must configure a value for EOM before you can set SOM or disable SOM. You need to change the value of SOM. Choose Serial Port from the Communications Menu.
Serial port configuration error.
The configurable serial protocol (CSP) uses EOM to determine the serial communications mode. When EOM is disabled, the terminal communicates in Character mode. When EOM is enabled, the terminal communicates in Frame mode. To use Frame mode, you need to set EOM first. Next, configure Handshake, Configuration Commands Via Serial Port, LRC, SOM, and then Poll.
SOM is set. You must also set EOM. Configuration was not updated. You are configuring the serial port and see this error message when exiting the Configuration Menu: Serial port configuration error. SOM cannot equal EOM. Configuration was not updated. You are configuring the serial port and see this error message when exiting the Configuration Menu: Serial port configuration error. DLE, XON, XOFF are not valid values for either SOM or EOM.
For help, see “Using Serial Communications on the Terminal” on page 44. SOM cannot equal the same value that is set for EOM. You cannot set SOM to any of these values: AFF (ACK), DLE, NEG (NAK), Poll, RES (EOT), REQ (ENQ), SEL, XOFF, or XON. You need to change the value of SOM. Choose Serial Port from the Communications Menu. For help, see “Start of Message (SOM)” in Chapter 6 of the 2400 Family system manual.
You cannot set EOM or SOM to any of these values: AFF (ACK), DLE, NEG (NAK), Poll, RES (EOT), REQ (ENQ), SEL, XOFF, or XON. You need to change the value of EOM or SOM. Choose Serial Port from the Communications Menu. For help, see “End of Message (EOM)” or “Start of Message (SOM)” in Chapter 6 of the 2400 Family system manual.
Configuration was not updated. You are configuring the serial port and see this error message when exiting the Configuration Menu: Serial port configuration error. EOM #1 cannot equal EOM #2. Configuration was not updated. You are configuring SOM or EOM in the Configuration Menu and cannot set two characters.
60
EOM can be one or two ASCII characters, but you cannot set the first and second character to the same character. Also, you cannot set EOM to any of these values: AFF (ACK), DLE, NEG (NAK), Poll, RES (EOT), REQ (ENQ), SEL, XOFF, or XON. You need to change the value of EOM #1 or #2. Choose Serial Port from the Communications Menu. For help, see “End of Message (EOM)” in Chapter 6 of the 2400 Family system manual. You may have a space in the SOM or EOM field. The space does not show, but it is a valid character. To clear a space from the field, put the cursor in the field and press :. Now set the two-character value for SOM or EOM.
Trakker Antares 241X Handheld Terminal User’s Manual
Page 75
nugget
39 AGaramond Chapter 4 - Troubleshooting and Maintenance
Problems While Configuring the Terminal (continued) Problem You scan a configuration command, such as Keypad Caps Lock, and nothing happens.
Solution There are two possible solutions:
• You may have one or more reader commands disabled, such as Change Configuration, so that you cannot change the configuration. Enable all of the reader commands and try again.
• The terminal may be waiting for another command to complete the configuration change. If you started by scanning the Enter Accumulate command, you must finish the command by scanning the Exit Accumulate command. For help, see Chapter 6, “Configuration Command Reference,” in the 2400 Family system manual. Scan the Enable Override to temporarily enable all of the reader commands. When you are finished, remember to disable the override so that your data is not interpreted as a command. Enable Override
*$+DC3* *$+DC3* You are configuring the serial port and see this error message when exiting the Configuration Menu:
PG is the Handshake configuration command. You need to change the value of Handshake or set other serial port parameters. Choose Serial Port from the Communications Menu.
PG command failed.
The order in which you set serial port protocol configuration commands is important. To use Frame mode, you need to set EOM first. Next, configure Handshake, LRC, SOM, and then Poll. To use Character mode, you need to disable these same parameters in reverse order.
Configuration was not updated.
For help, see “Using Serial Communications on the Terminal” on page 44. You scan or enter an option for the Scanner Selection configuration command and you hear three low beeps.
You may have scanned or entered a Scanner Selection command that does not apply to the type of scanner that you have installed. Try scanning or entering the Scanner Selection command again and select an option for the type of module you have installed.
You are scanning a configuration command to set one of the serial port parameters and hear three low beeps. For example, you are trying to set EOM or SOM.
The order in which you scan serial port protocol configuration commands is important. The configurable serial protocol (CSP) uses EOM to determine the serial communications mode. When EOM is disabled, the terminal communicates in Character mode. When EOM is enabled, the terminal communicates in Frame mode. To use Frame mode, you need to set EOM first. Next, configure Handshake, Configuration Commands Via Serial Port, LRC, SOM, and then Poll. To use Character mode, you need to disable these same parameters in reverse order. For help, see “Using Serial Communications on the Terminal” on page 44.
Trakker Antares 241X Handheld Terminal User’s Manual
61
Page 76
Chapter 4 - Troubleshooting and Maintenance nugget
39 AGaramond
Problems While Configuring the Terminal (continued) Problem You see this error message when exiting the Configuration Menu:
Solution The two-character name (syntax) of the configuration command that failed is listed on the first line of the error message.
Commandname command failed.
Check the command listed in the message. To find the command, use the “Configuration Commands by Syntax” table in Appendix A of the 2400 Family system manual. Make sure the command is set correctly for the options and network communications you are using with the terminal. For help, see Chapter 6, “Configuration Command Reference,” in the 2400 Family system manual.
Remainder of configuration not updated.
For example, you may see this message: SS command failed. There may be a problem with the configuration due to a change made with the Scanner Selection (SS) command. On a 2415, you see this error message when exiting the Configuration Menu: Network configuration error. Network is enabled. Terminal IP address or Controller (Host) IP address set to an invalid address of 0.x.x.x or 127.x.x.x. Configuration was not updated.
The 2.4 GHz RF network is enabled and there is a problem with the network configuration. You need to change the terminal IP address and/or the controller IP address (host IP address for a TCP/IP network). Choose Primary Network from the Communications Menu.
On a 2415, you configure the security ID and the changes do not appear to be saved.
You can only set the security ID with the 2.4 GHz RF network enabled. The Network Activate command must be set to the 2.4 GHz RF network before you can save any changes to the security ID command.
You scan a configuration command, such as Keypad Caps Lock, and you hear three low beeps.
If you are working in the TRAKKER Antares 2400 Menu System, you cannot scan configuration commands. Use the Configuration Menu to change the terminal’s configuration, or exit the menu system to scan configuration commands.
On a 2415, you see this error message when exiting the Configuration Menu: Network configuration error. Network is enabled. Terminal IP address and Default Router address set to the same address. Configuration was not updated.
The 2.4 GHz RF network is enabled and there is a problem with the network configuration. You need to change the terminal IP address and/or the default router address. Choose Primary Network or Advanced Network from the Communications Menu.
62
The terminal IP address or the controller/host IP address is set to 0.x.x.x or 127.x.x.x. These are invalid addresses. Set a valid IP address for the terminal and controller or host. For help, see “Using RF Communications on the 2415” on page 48. If you cannot fix the addressing problem, check with your network administrator to get the IP address assigned to the terminal and the Intermec Gateway or DCS 30X or the host.
The terminal IP address and the default router address are both set to the same address. Set a valid IP address for the terminal and the default router. For help, see “Using RF Communications on the 2415” on page 48. If you cannot fix the addressing problem, check with your network administrator to get the IP addresses for each RF network device.
Trakker Antares 241X Handheld Terminal User’s Manual
Page 77
nugget
39 AGaramond Chapter 4 - Troubleshooting and Maintenance
Problems While Configuring the Terminal (continued) Problem On a 2415, you see this error message when exiting the Configuration Menu: Network configuration error. Network is enabled. Terminal IP address and Controller (Host) IP address set to the same address. Configuration was not updated.
Solution The 2.4 GHz RF network is enabled and there is a problem with the network configuration. You need to change the terminal IP address and/or the controller IP address (host IP address for a TCP/IP network). Choose Primary Network from the Communications Menu. The terminal IP address and the controller/host IP address are both set to the same address. Set a valid IP address for the terminal and Intermec Gateway, DCS 30X, or host. For help, see “Using RF Communications on the 2415” on page 48. If you cannot fix the addressing problem, check with your network administrator to get the IP address assigned to the terminal and the controller or host.
On a 2415, you see this error message when exiting the Configuration Menu: Network configuration error. Network is enabled. Default Router address is not on the terminal’s network. Configuration was not updated.
The 2.4 GHz RF network is enabled and there is a problem with the network configuration. You need to change the default router address. Choose Advanced Network from the Communications Menu. The terminal and Intermec Gateway or DCS 30X (UDP Plus or WTP network), or host (TCP/IP network) are on different networks, and the terminal is not on the same network as the default router. When the terminal is on a different IP subnetwork from the Intermec Gateway, DCS 30X, or host, you must set the Default Router and Subnet Mask commands. Set a valid IP address for terminal, Intermec Gateway or DCS 30X or host, and default router. For help, see “Using RF Communications on the 2415” on page 48. If you cannot fix the addressing problem, check with your network administrator to get the IP addresses for each RF network device.
On a 2415, you scan a configuration command to set one of these parameters and hear three low beeps:
If the Network Activate command is enabled (2.4 GHz RF network enabled) and you are configuring the 2415, these IP addresses must be valid.
• Controller IP Address (UDP Plus)
To set these four parameters, follow these steps:
or Host IP Address (TCP/IP)
• Terminal IP Address • Default Router • Network Activate
1 Disable the Network Activate (NA) configuration command. 2 Set the terminal IP address. 3 Set the controller IP address or the host IP address. 4 Set the default router address (if necessary). 5 Enable the Network Activate command. You can change an IP address with the network enabled as long as it still defines a valid network configuration.
On the 241X with an integrated PDF417 scanner, you configure the Scanner Trigger command to enable pulse triggering, and the changes do not appear to be saved.
Earlier versions of PDF417 scanners do not support pulse triggering. For help upgrading your scanner, consult your local Intermec service representative.
You are configuring a 241X with the clone application and see an error message.
The server terminal and the client terminal may not have the same hardware or software configuration. Make sure that both terminals have the same hardware configuration, firmware version, and clone application version. For help, see Chapter 2, “Configuring and Managing the Terminals,” in the 2400 Family system manual.
Trakker Antares 241X Handheld Terminal User’s Manual
63
Page 78
Chapter 4 - Troubleshooting and Maintenance nugget
39 AGaramond
Problems While Configuring 802.1x Security If you have trouble configuring the terminal for 802.1x security, check these problems and possible solutions. For more error numbers and messages, see “802.1x Security Error Numbers and Messages” in Chapter 4 of the 2400 Family system manual. This section references error numbers that are displayed on the Error Logger screen in the TRAKKER Antares 2400 Menu System. To view the Error Logger screen, from the Main Menu, choose Diagnostics Menu, Software Diagnostics, and then Error Logger. Problems While Configuring 802.1x Security Problem The terminal indicates that it is authenticated by emitting a low beep and a high beep, but it does not communicate with the host.
Possible Solution Make sure that the terminal IP address, host IP address, subnet mask, and default router are properly configured for your network.
Note: Do not cold boot the terminal. Cold booting the terminal resets the time and date. The “AUTHENTICATING” message does not appear on the screen, and the Network Connect status LED is not on.
The terminal may not be communicating with your MobileLAN access point. Make sure that
• the network name on the terminal is the same as the network name (SSID) of the access point that you are trying to communicate with. The default network name is “INTERMEC.”
• the Network Activate command is enabled on your terminal. The 802.1x security network may not be active. Make sure that the Odyssey™ server software is properly loaded and configured on the server PC. For help, see the documentation that shipped with your server software. The terminal indicates that it is not authenticated by emitting a high beep and a low beep. This error code appears on the Error Logger screen: 0x377
Make sure that:
• the User Name and Password parameters on your terminal match the user name and password on your Odyssey server. You may need to re-enter the password on both your terminal and Odyssey server.
• on your Odyssey server, the user and group are allowed and the group policy is allowed to log in to the Odyssey server. For help, see the documentation that shipped with your Odyssey server software.
• the IP address and secret key for your MobileLAN access point must match the IP address and secret key on your Odyssey server. You may need to re-enter the IP address and secret key on both your MobileLAN access point and Odyssey server.
• your Odyssey server is active and that it can communicate with your MobileLAN access point. You can use the PING command to determine communications.
• the Odyssey server software is running on the server PC. • the UDP port (standard RADIUS port, 1812) on your Odyssey server is active. For help, see the documentation that shipped with your Odyssey server software.
64
Trakker Antares 241X Handheld Terminal User’s Manual
Page 79
nugget
39 AGaramond Chapter 4 - Troubleshooting and Maintenance
Problems While Configuring 802.1x Security (continued) Problem The “AUTHENTICATING” message does not appear on the screen. The Network Connect status LED turns on, but it does not stay on.
Possible Solution The terminal may not be communicating with the MobileLAN access point that you want it to communicate with. Make sure that the network name on the terminal is the same as the network name of the access point that you are trying to communicate with. The default network name is “INTERMEC.” The MobileLAN access point that you are trying to communicate with may not be communicating with the Odyssey server. Make sure your MobileLAN access point is turned on, properly configured, and has 802.1x security enabled.
The “AUTHENTICATING” message appears on the screen, but the terminal does not emit a low beep and a high beep to indicate that it is authenticated.
The terminal takes up to 60 seconds to authenticate; however, this process may take longer if there is interference in RF communications. You may need to wait for the authentication process to finish.
The “AUTHENTICATING” message appears on the screen, but the terminal does not emit a low beep and a high beep to indicate that it is authenticated.
The authentication process timed out. You may be out of range of the MobileLAN access point that you are trying to communicate with. Try moving closer to the MobileLAN access point.
You may be out of range of the MobileLAN access point you are trying to communicate with. Try moving closer to the MobileLAN access point.
This error code appears on the Error Logger screen: 0x37B The terminal indicates that it is not authenticated by emitting a high beep and a low beep. One of these error codes appears on the Error Logger screen: 0x50A or 0x509
The time and date on your terminal does not fall within the range of valid dates indicated on the server certificate. Modify the time and date so that it falls within the range of valid dates. For help, see “Time and Date” in Chapter 6 of the 2400 Family system manual. If this is a recurring problem, you may want to update the BASEDATE.TXT file on your terminal.
1 Make sure that your PC is configured with the correct date and time and that you have BASEDATE.TXT and LOADER.EXE on your PC. These files are available as part of the firmware upgrade that can be downloaded at no charge from the Intermec Web site at www.intermec.com.
2 Follow Steps 1 through 5 of the procedure To transfer applications and files to the terminal using LOADER.EXE in Chapter 3, “Developing and Using Applications” in the 2400 Family system manual.
3 On your PC, type: LOADER pathname\BASEDATE.TXT where pathname is the path to the location of BASEDATE.TXT on your PC. The Loader screen appears. BASEDATE.TXT is set to the current time and date on your PC and is transferred to your terminal.
Trakker Antares 241X Handheld Terminal User’s Manual
65