The text of a manual · part 6 of 11
Trakker Antares 241X Handheld Terminal User's Manual: Chapter 3 - Operating the Terminals in a Network, pages 51 to 60
Pages 51 to 60 of 106, from Trakker Antares 241X Handheld Terminal User's Manual
The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2410 and Intermec 2415
Page 51
3
Operating the Terminals in a Network
This chapter explains how the terminals fit into a data collection network and what parameters to configure for your serial or RF network. This chapter covers these topics: • How the terminals fit into your network • Using serial communications on the terminal • Using RF communications on the 2415 • Enabling 802.1x TTLS or LEAP security
Trakker Antares 241X Handheld Terminal User’s Manual
37
Page 52
Chapter 3 - Operating the Terminals in a Network nugget
39 AGaramond
How the Terminals Fit Into Your Network The Trakker Antares® 2410 and 2415 terminals are versatile hand-held terminals that you can easily add to your network or distributed data collection system. You use these terminals as end devices in your wired or RF network. The terminals have a serial port that lets them transmit data to and receive data from a host computer or PC via RS-232 serial communications. The terminal can communicate with the RS-232 device using one of these protocols: Binary, Configurable, Master Polling, Polling Mode D, or Point-to-Point. Note: If you insert the terminal into a communications dock, you can transmit data to and receive data from a host computer or PC via RS-232 serial communications. Mainframe
Terminals
File server
Ethernet
RS-232 241X hardwired to PC using a communications dock PC
241X in a Wired Network
38
Trakker Antares 241X Handheld Terminal User’s Manual
Page 53
nugget
39 AGaramond Chapter 3 - Operating the Terminals in a Network
You can also use the serial port to connect to a 900 MHz RF network via the 9189 RF Gateway. The terminal communicates with the 900 MHz RF network using Polling Mode D protocol. Host
G4000
RS-485 900 MHz
9181
900 MHz terminal
9189 RS-232
900 MHz terminal
241X
241X in a 900 MHz RF Network
Trakker Antares 241X Handheld Terminal User’s Manual
39
Page 54
Chapter 3 - Operating the Terminals in a Network nugget
39 AGaramond
UDP Plus or WTP Network In a UDP Plus or WTP network, 2415s communicate with a host computer through the G4000. The UDP Plus or WTP packets are translated on the RF network into TCP/IP packets on the wired network and vice versa. The access point acts as a bridge between the wired network and the RF network. Host
2415s
Access point
Ethernet
G4000
2415s in a UDP Plus or WTP Network
40
Trakker Antares 241X Handheld Terminal User’s Manual
Page 55
nugget
39 AGaramond Chapter 3 - Operating the Terminals in a Network
TCP/IP Direct Connect Network In a TCP/IP network, 2415s communicate with a host computer directly using TCP/IP for the RF protocol. The access point acts as a bridge between the wired network and the RF network. Host
2415s
Access point
Ethernet
2415s in a TCP/IP Direct Connect Network
Trakker Antares 241X Handheld Terminal User’s Manual
41
Page 56
Chapter 3 - Operating the Terminals in a Network nugget
39 AGaramond
Multiple Subnetworks (UDP Plus) In a UDP Plus network, you can install 2415s, access points, and the G4000 as shown in the next illustration. All the terminals and access points in this illustration communicate with the G4000 at IP address 192.9.175.7. If you are using MobileLAN™access points, a terminal can roam across subnetworks. However, to roam across subnetworks, all terminal IP addresses must belong to the root IP subnet. In this illustration, if the root IP subnet is 192.9.175.X and all terminals had a terminal IP address of 192.9.175.X, they could roam across subnetworks. For more information, see the MobileLAN access System Manual (P/N 067150). 192.9.175.7 G4000
192.9.200.X subnetwork
Router
Access point
Ethernet
Access point
192.9.175.X subnetwork
Access point
2415s 192.9.175.10 192.9.175.11 192.9.175.12
2415s 192.9.200.5, 192.9.200.6
2415s in Multiple Subnetworks (UDP Plus)
42
Trakker Antares 241X Handheld Terminal User’s Manual
Page 57
nugget
39 AGaramond Chapter 3 - Operating the Terminals in a Network
Multiple Subnetworks (TCP/IP) In a TCP/IP network, you can install the 2415s and access points as shown in the illustration below. All the terminals and access points in this illustration communicate with the host at IP address 192.9.175.7. If you are using MobileLAN access points, a terminal can roam across subnetworks. However, to roam across subnetworks, all terminal IP addresses must belong to the root IP subnet. In this illustration, if the root IP subnet is 192.9.175.X and all terminals had a terminal IP address of 192.9.175.X, they could roam across subnetworks. For more information, see the MobileLAN access System Manual. Host
192.9.175.7
192.9.200.X subnetwork
Router
Access point
Ethernet
Access point
192.9.175.X subnetwork
Access point
2415s 192.9.175.10 192.9.175.11 192.9.175.12
2415s 192.9.200.5, 192.9.200.6
2415s in Multiple Subnetworks (TCP/IP)
Trakker Antares 241X Handheld Terminal User’s Manual
43
Page 58
Chapter 3 - Operating the Terminals in a Network nugget
39 AGaramond
Communicating Across Subnetworks (UDP Plus) You can install 2415s and access points in one subnetwork and install the G4000 or host in another subnetwork. If the 2415s are communicating across a subnetwork, you must configure additional network parameters (subnet mask and default router). The illustration below shows the G4000 in another subnetwork from the terminals. 192.9.200.5 G4000
192.9.200.X subnetwork
Router
192.9.175.X subnetwork Ethernet
192.9.175.1
Access point
2415s 192.9.175.9 192.9.175.10 192.9.175.11
2415s Communicating Across Subnetworks (UDP Plus)
Using Serial Communications on the Terminal The terminals have a serial port (COM1) to transfer data to and receive data from another device via RS-232 serial communications. You can also insert the terminal into a communications dock to transmit data to and receive data from a host computer or PC via serial communications. Before you can use serial communications, you must perform these steps: 1 Connect COM1 to the serial port of the other device. For help, see “Using the Terminal’s Serial Port” on page 19. Or, insert the terminal into the communications dock. For help, see the Trakker Antares TD2410 Communications Dock Quick Reference Guide (P/N 069552).
44
Trakker Antares 241X Handheld Terminal User’s Manual
Page 59
nugget
39 AGaramond Chapter 3 - Operating the Terminals in a Network
2 Choose a communications protocol. For help, see the next section, “Choosing a Communications Protocol.” 3 Configure the serial port parameters. For help, see Chapter 2, “Configuring the Terminals.” Depending on the protocol you chose in Step 2, you must set some or all of the serial port parameters to have the terminal communicate with a host computer or serial device in a wired network. The values you set for the terminal’s serial port parameters must match the values set for the host’s (or other device’s) serial port parameters.
Choosing a Communications Protocol After you connect the 241X to a host computer or other serial device, you are ready to configure the serial port parameters on the two devices. The terminal uses a communications protocol and XMODEM, XMODEM1K, or YMODEM to handle data communications through the serial ports. You can configure a different communications protocol for each COM port. The terminal’s built-in file operations use XMODEM, XMODEM1K, or YMODEM for file transfer. Communications protocols determine exactly how data is transmitted between the terminal and the connected device. Each protocol has parameters you can set, such as baud rate and parity. Both the terminal and the connected device must use the same protocol and parameter settings to communicate properly. For help with protocols, see the Data Communications Reference Manual (P/N 044737).
Binary Protocol Binary protocol has no protocol. Characters are sent and received without being altered. The Data Link Escape character (DLE) is not inserted before any character, and DLE characters are not stripped out of the incoming data stream. No protocol characters, such as EOM or SOM, are added. Binary mode supports CTS/RTS flow control. You can configure the following serial port parameters: • Baud rate • Data bits • Parity • Stop bits • Flow control
Trakker Antares 241X Handheld Terminal User’s Manual
45
Page 60
Chapter 3 - Operating the Terminals in a Network nugget
39 AGaramond
Configurable Protocol Configurable protocol is based on Intermec’s Polling Mode D protocol except that you have the option to change some of the serial port protocol parameters or remove specific events from the protocol, such as poll or handshake. You can configure the following serial port parameters: • Baud rate • Data bits • Parity • Stop bits • Flow control • EOM (End of Message) • Configuration commands via serial port • LRC • SOM (Start of Message) • Handshake (enabled or disabled) • Poll (Polling) (enabled or disabled) • Timeout Delay Configurable protocol uses EOM to determine one of the following serial communications modes.
Character Mode When EOM is disabled, the terminal communicates in Character mode processing each character. Character mode supports both XON/XOFF and CTS/RTS flow control.
Frame Mode When EOM is enabled, the terminal communicates in Frame mode. When a terminal sends a packet, it adds a protocol character. When a terminal receives a packet, it strips any protocol characters before it sends the information to the terminal application. Frame mode supports both XON/XOFF and CTS/RTS flow control. In Frame mode, you can also configure the following serial port parameters: • Configuration commands via serial port • Handshake • LRC • SOM After you enable Handshake, you can define poll and timeout delay.
46
Trakker Antares 241X Handheld Terminal User’s Manual