The text of a manual · part 5 of 11
Trakker Antares 241X Handheld Terminal User's Manual: Chapter 2 - Configuring the Terminals
Pages 39 to 50 of 106, from Trakker Antares 241X Handheld Terminal User's Manual
The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2410 and Intermec 2415
Page 39
2
Configuring the Terminals
This chapter explains the different methods that you can use to configure the 241X and its memory and drives. It also explains how to configure the terminals using the TRAKKER Antares 2400 Menu System. This chapter covers these topics: • How to configure the terminal • Configuring the terminal with the menu system • Configuring drives and memory on the terminal
Trakker Antares 241X Handheld Terminal User’s Manual
25
Page 40
Chapter 2 - Configuring the Terminals nugget
39 AGaramond
How to Configure the Terminal You can customize many operating characteristics of the Trakker Antares® 2410 and 2415 terminals, such as the volume of their audio signals and the bar code symbologies they decode. These characteristics are controlled by configuration parameters. The values you set for the parameters determine how the terminal operates. To learn about each configuration parameter, see Chapter 6, “Configuration Command Reference,” in the Trakker Antares 2400 Family System Manual (P/N 071389). You can configure the terminals by using any of the following methods.
Use the TRAKKER Antares 2400 Menu System You can use the menus and screens of the TRAKKER Antares 2400 Menu System to view the current configuration and change the configuration parameters. For help, see “Configuring the Terminal With the Menu System” on page 27.
Scan Bar Codes You can change the terminal’s configuration parameters by scanning Code 39 or Code 93 bar code labels that contain configuration commands. This method is a fast, easy way to change the terminal’s configuration. You can scan the bar code labels in this manual and the 2400 Family system manual, or you can create your own bar code labels. For help, see Chapter 2, “Configuring and Managing the Terminals,” in the 2400 Family system manual.
Send Commands Through the Serial Port You can change the terminal’s configuration parameters by sending commands from a host computer or PC that is connected to the terminal’s serial port. For help, see Chapter 2, “Configuring and Managing the Terminals,” in the 2400 Family system manual.
Send Commands Through the RF Port (2415 Only) You can change the terminal’s configuration parameters by sending commands through the UDP Plus or TCP/IP network. This method lets you configure one or more terminals at the same time. For help, see Chapter 2, “Configuring and Managing the Terminals,” in the 2400 Family system manual.
Use the Clone Application You can set the terminal’s configuration parameters by using the clone application to copy parameters from one 241X to another 241X. This method is a fast, easy way to configure a new 241X with the same parameters as an existing 241X. For help, see Chapter 2, “Configuring and Managing the Terminals,” in the 2400 Family system manual. 26
Trakker Antares 241X Handheld Terminal User’s Manual
Page 41
nugget
39 AGaramond Chapter 2 - Configuring the Terminals
Use the Wavelink Avalanche Manager You can send configuration information to multiple terminals in your RF network using the Wavelink Avalanche client management system and the Intermec Settings application. For help, see Chapter 2, “Configuring and Managing the Terminals,” in the 2400 Family system manual.
About the Configurations The terminal uses three configurations: current, active, and default. Having separate current and active configurations lets you control the active configuration while letting each operator make some changes to the current configuration, such as scanning a bar code to change the beep volume. Configuration Descriptions Configuration Current
Description This configuration, also called the runtime configuration, uses the configuration that is saved in RAM. When you change a parameter by using the menu system, by scanning a bar code, by sending it from a host application, or by sending it from the Intermec Gateway or DCS 30X, the terminal updates the current configuration. The changes to the current configuration are lost when you boot or reset the terminal.
Active
When you update the flash memory, the terminal copies the current configuration to the active configuration. The active configuration is the configuration that the terminal uses when you boot or reset the terminal.
Default
This configuration is the factory default configuration. To restore the default configuration, see “Restoring the Terminal’s Default Configuration” in Chapter 2 of the 2400 Family system manual.
Configuring the Terminal With the Menu System The TRAKKER Antares 2400 Menu System lets you configure the terminal, manage files, view system information, and run diagnostics. You can access the TRAKKER Antares 2400 Menu System while running any application. When you are using the menu system, you may not see a parameter until you set a value for another key field. For example, EOM is a key field when you configure the Configurable protocol. That is, several fields are invalid (do not appear) until you enable EOM. You also may not see a parameter if your terminal does not support a feature.
Trakker Antares 241X Handheld Terminal User’s Manual
27
Page 42
nugget
Chapter 2 - Configuring the Terminals
39 AGaramond
To access the TRAKKER Antares 2400 Menu System • Press ( \ 2 4 8 or scan this bar code: TRAKKER Antares 2400 Menu System
*..-.* *..-.*
The Main Menu appears, displaying four menu options. MAIN
MENU
Configuration Menu Diagnostics Menu System Menu About TRAKKER 2400
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 241XU050.eps
Main Menu Options Menu Configuration
Description Choose this menu to configure bar code symbologies, network and communications parameters, serial port parameters, and the terminal’s operating characteristics. In the Symbologies Menu, active symbologies are noted with an asterisk (*).
Diagnostics
Choose this menu to run hardware, software, or system diagnostics to help analyze and fix problems. You can also view battery and system information. For help, see Chapter 4, “Running Diagnostics,” in the 2400 Family system manual.
System
Choose this menu to manage files, load the default configuration, set the time and date, store the terminal’s configuration in flash memory, and upgrade the firmware.
About TRAKKER 2400
Choose this option to see the part number, firmware version, radio, and RF protocol (UDP Plus, WTP, or TCP/IP), and security (WEP, 802.1x TTLS, or 802.1x LEAP) that is loaded on the terminal. You may need this information if you are working a problem with an Intermec representative. If you are using a DHCP server, this menu option also displays the DHCP-assigned IP address.
28
Trakker Antares 241X Handheld Terminal User’s Manual
Page 43
nugget
39 AGaramond Chapter 2 - Configuring the Terminals
MAIN MENU
CONFIGURATION MENU
Configuration Menu Diagnostics Menu System Menu About TRAKKER 2400
Symbologies Menu Symbology IDs Menu Communications Menu Terminal Menu Device Management
SYMBOLOGIES
MENU
*Code 39 Codabar Code 93 *Code 128 2of5 / I 2of5 MSI Plessey *UPC / EAN
SYSTEM MENU File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware Clone Unit
DIAGNOSTICS
CONFIGURATION MENU Symbologies Menu Symbology IDs Menu Communications Menu Terminal Menu Device Management
MENU
Software Diagnosticss Hardware Diagnostics System Diagnostics
CONFIGURATION MENU Symbologies Menu Symbology IDs Menu Communications Menu Terminal Menu Device Management
Error Logger Application Events Task Status Clear Task Profiles Font Test Keypad Table
CONFIGURATION MENU
HARDWARE DIAGNOSTICS
Symbologies Menu Symbology IDs Menu Communications Menu Terminal Menu Device Management
SYSTEM DIAGNOSTICS
IDs
MENU
COMMUNICATIONS MENU Primary Network Advanced Network Radio Serial Port [COM1]
SOFTWARE DIAGNOSTICS
Hardware Config Battery/PIC Status Display Test Keypad Test Main Board Menu Radio Test Scanner Test
SYMBOLOGY
All Symbology IDs Code 39 Code 128 Codabar Code 93 Code 11 I 2of5 MSI Plessey UPC A UPC E EAN 8 EAN 13 S 2of5 2 Bar St/Sp S 2of5 3 Bar St/Sp
CONFIGURATION MENU
TERMINAL
MENU
Append Time Beeper Display Keypad Power Management Preamble/Postamble RAM Drive Reader Command Menu Scanner
Symbologies Menu Symbology IDs Menu Communications Menu Terminal Menu Device Management
Subsystem Versions Access Point App Efficiency Serial Port Test Malloc Info Menu Code Verify
DEVICE
MANAGEMENT
Use Device Manager IP
Mgmt
241XU032.eps
The TRAKKER Antares 2400 Menu System at a Glance
Accessing Online Help The TRAKKER Antares 2400 Menu System provides online help for the menus and commands. To access a help screen • Press ! to access a help screen. To exit a help screen • Press % to exit the help screen.
Trakker Antares 241X Handheld Terminal User’s Manual
29
Page 44
Chapter 2 - Configuring the Terminals nugget
39 AGaramond
Selecting Menus and Commands A menu consists of a list of secondary menu items or commands. From the Main Menu, you can press = or > or ; to select a menu and then press \ or [. MAIN
MENU
SYSTEM
MENU
Configuration Menu Diagnostics Menu System Menu About TRAKKER 2400
File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware Clone Unit
_` Select item [Enter] Next screen [F1] Help [Esc] Exit
_` Select item [Enter] Next screen [F1] Help [Esc] Exit
241XU050.eps
241XU034.eps
Selecting Menus and Commands: For example, from the Main Menu, press > > \ to display the System Menu.
Filling In Fields Screens contain fields into which you can enter data. In the TRAKKER Antares 2400 Menu System, this data configures the terminal. You can press = or > or ; to choose a field on a screen and then enter the data. There are two types of fields: entry fields and toggle fields. • In a toggle field, press ( = or ( > to view the options for that field. • In an entry field, type a value into the field. To edit the data in an entry field, use the Backspace (:) or Space (( :) keys. You can also use the Delete (( .) and Insert (( 0) keys to edit an entry field. PRIMARY NETWORK Activate: Disabled Host IP Addr: 0.0.0.0 Terminal IP Address: 0.0.0.0
OK
CANCEL 241XU037.eps
Toggle and Entry Fields: For example, the Primary Network screen has toggle and entry fields. The Activate field is a toggle field. Press ( = to toggle between Disabled and 802.11 DS or OpenAir. The Host IP Address and Terminal IP Address fields are entry fields. You type a value into the field for each IP address.
30
Trakker Antares 241X Handheld Terminal User’s Manual
Page 45
nugget
39 AGaramond Chapter 2 - Configuring the Terminals
To exit a screen • To save the changes to the current configuration file, press = or > or ; to choose OK and press \. Or, press \ with the cursor in any field except the Cancel button. Or, to discard the changes, press = or > or ; to choose Cancel and press \. Or, press % with the cursor in any field.
Marking Check Boxes Screens may contain check boxes. Check boxes are used when you can select more than one option at one time. To mark or clear check boxes, press ( :. READER COMMAND MENU [Space] to enable or disable a command [X] Abort Program [X] Backlight [X] Backspace [X] Change Config [X] Clear [X] Default Config [X] Delete File [X] Enter Accum [X] Exit Accum [X] List Files
[X] [X] [X] [X] [X] [X] [X] [X] [X]
Multi-Read Receive File Rename File Reset Run Program Scanner On Scanner Off Test & Service Transmit File
OK
CANCEL more
_
241XU038.eps
Marking Check Boxes: For example, press = or > or ; to choose the Abort Program check box and press ( : to clear the check box. The Abort Program reader command is now disabled.
Entering ASCII Control Characters You can include ASCII control characters in a postamble or preamble by using the TRAKKER Antares 2400 Menu System. For a definition of the postamble or preamble, see Chapter 6, “Configuration Command Reference,” in the 2400 Family system manual. You can configure the postamble or preamble to characters from the full or extended ASCII character sets. For example, the Field Exit code (Ü) for 5250 terminal emulation is an extended ASCII character that is often configured as the postamble. To enter ASCII characters for a preamble or postamble 1 Decide which ASCII control character you want to set for the preamble or postamble. Look up the control character in the “Full ASCII Table” in Appendix B of the 2400 Family system manual and find the twodigit hexadecimal number. For example, ETX in the Full ASCII Table is the hexadecimal value 03. Trakker Antares 241X Handheld Terminal User’s Manual
31
Page 46
Chapter 2 - Configuring the Terminals nugget
39 AGaramond
To enter an extended ASCII character, look up the character in the “Trakker Antares Terminal Font Set” in Appendix C of the 2400 Family system manual and find the two-digit hexadecimal number. For example, Ü (the 5250 Field Exit code) in the table has the hexadecimal value 9A. 2 Use the TRAKKER Antares 2400 Menu System to configure a preamble or postamble. Choose Main Menu > Configuration Menu > Terminal Menu > Preamble/Postamble. PREAMBLE
/
POSTAMBLE
Preamble: abc Postamble: \x0D\x0A
OK
CANCEL 241XU040.eps
3 Move the cursor to the field for the preamble or postamble. 4 Type the control character, extended ASCII character, or escape character sequence in the preamble or postamble field. • To type a control character or extended ASCII character in the preamble or postamble field, use this syntax: \xhh where hh is the two-digit hexadecimal number for the control character or the extended ASCII character. For example, to enter ETX as a preamble, type: \x03
To enter Ü (the 5250 TE Field Exit code) as the postamble, type: \x9A
• To type an escape character (backslash) in the preamble or postamble field, you must type two backslashes. The application ignores the first backslash (\) character and saves the next characters. For example: Enter These Characters \\
Preamble/Postamble Saved \
\\k
\k
\ no data
5 Press \ or choose OK to save your changes and exit the screen.
32
Trakker Antares 241X Handheld Terminal User’s Manual
Page 47
nugget
39 AGaramond Chapter 2 - Configuring the Terminals
For help exiting the menu system, see the next two sections, “Exiting Screens and Saving Changes” and “Exiting the Menu System.”
Exiting Screens and Saving Changes When you exit a screen, you can save or discard your changes: Exiting Screens and Saving Changes Task To exit a screen and save the changes
Description Choose OK and press \. You can also press \ with the cursor positioned anywhere except on the Cancel button.
To exit a screen and discard the changes
Choose Cancel and press \. You can also press \ with the cursor in any field.
Exiting the Menu System 1 Press % until you exit the TRAKKER Antares 2400 Menu System. If you have made any changes to the current configuration, this screen prompts you to save the configuration parameters that are currently enabled on the terminal to RAM. Save new configuration (in
RAM)?
Yes
No
CANCEL
241XU053.eps
2 Choose Yes and press \ to save your changes in RAM and update the current configuration on the terminal. The Main Menu appears. Or, choose No and press \ to exit without changing the configuration. The Main Menu appears. Or, choose Cancel and press \ to return to the previous menu or screen. 3 From the Main Menu, press %. If you have made any changes, the next screen prompts you to store the changes in flash memory.
Trakker Antares 241X Handheld Terminal User’s Manual
33
Page 48
Chapter 2 - Configuring the Terminals nugget
39 AGaramond
Store configuration changes in flash memory? (used when rebooting the terminal)
Yes
No
CANCEL
241XU051.eps
Note: You can also save the current configuration to flash memory by choosing the Store Configuration command from the System Menu. For help, see “Saving Configuration Changes in Flash Memory” in Chapter 2 of the 2400 Family system manual. 4 Choose Yes and press \ to save your changes in RAM and update the current configuration on the terminal. The Main Menu appears. 5 Choose Yes and press \ to save your changes to flash memory. The terminal saves the current configuration as the active configuration. The Exiting TRAKKER Antares 2400 Menu System screen appears. Or, choose No and press \ to exit without saving. The terminal continues to use your changes until you boot or reset the terminal. The Exiting TRAKKER Antares 2400 Menu System screen appears. Or, choose Cancel and press \ to return to the Main Menu.
Exiting TRAKKER Antares 2400 Menu System
OK
CANCEL 241XU042.eps
6 Choose OK and press \ to exit the TRAKKER Antares 2400 Menu System. Or, choose Cancel and press \ to return to the Main Menu. After you exit the menu system, the terminal will resume the application you were running when you started the menu system.
34
Trakker Antares 241X Handheld Terminal User’s Manual
Page 49
nugget
39 AGaramond Chapter 2 - Configuring the Terminals
Configuring Drives and Memory on the Terminal The 241X comes with a 750K flash drive(C), 512K RAM reserved for applications, and an additional 2MB extended flash memory. You can customize the terminal to your needs by configuring • up to 256K of the 512K RAM as a RAM drive. • the additional 2MB flash memory of the 4MB flash memory option to either store double-byte fonts or to use as a 2MB drive.
Configuring the RAM Drive The 241X has a total of 512K RAM for the application execution space. You can configure up to 256K of the total 512K application execution space as a RAM drive. If the RAM drive is configured, your application execution space is reduced by the amount of the RAM drive. For example, if your application size is 64K and drive E is configured as a 256K RAM drive, you are using 320K of the 512K application execution space. The application uses the remaining 192K of RAM as a Malloc/free dynamic memory pool. By default, the RAM drive is not configured and the memory is available for applications. You can configure the size of the RAM drive (E) and use drive E to temporarily store data and files (up to 128 files). After you disable or configure the RAM drive, you must save the configuration in flash memory and boot the terminal for the change to take effect. For help, see “Saving Configuration Changes in Flash Memory” in Chapter 2 of the 2400 Family system manual. Note: When you boot or reset the terminal, all files on the RAM drive are destroyed. For help configuring the RAM drive, see “RAM Drive Size” in Chapter 6 of the 2400 Family system manual.
Configuring Flash Memory If you ordered the optional 4MB flash memory drive, you have an additional 2MB of extended flash memory. You can use this flash memory either to store double-byte fonts or to use as a 2MB drive. By default, the additional 2MB of flash memory is configured to store a double-byte font set (up to 2MB maximum). Note: The 4MB flash memory is required for 802.1x TTLS security and is not available to store files or double-byte fonts. For more information about configuring 802.1x TTLS security, see “Configuring 802.1x TTLS Security” on page 53.
Trakker Antares 241X Handheld Terminal User’s Manual
35
Page 50
Chapter 2 - Configuring the Terminals nugget
39 AGaramond
If you are not using double-byte fonts, you can configure the 2MB flash memory as a storage drive (D). If you configure the flash memory as drive D, use this drive to store large lookup tables and data files (up to 128 files). You can only configure the 2MB flash memory as a drive or to store fonts. You cannot use the space for both. If you configure drive D, you cannot also store a font in flash memory. For help configuring flash memory, see “Flash Memory Configuration” in Chapter 6 of the 2400 Family system manual. For help loading doublebyte fonts, see “Loading Double-Byte Fonts” in Chapter 2 of the 2400 Family system manual.
36
Trakker Antares 241X Handheld Terminal User’s Manual