Page 231
Wand emulation
Wand emulation Connection scanner input port
× host system power supply (if required)
wand emulation cable
1. Switch off the host system. 2. Use the wand emulation cable to connect the MaxiScan 2200 to the host system. 3. If your host system requires an external power supply: •
Connect the power supply to the wand emulation cable.
•
Plug the power supply into the mains socket.
M Do not switch on the host system until you have connected up and plugged in the external power supply.
MS/2200/RM/00/E/970131
221
Page 232
Wand emulation Predefined interface numbers N° 130 - Digital Wand Emulation
If your interface number is not among the predefined interface numbers, you must compose the number yourself (Ð Compose interface number ). The orange indicator LED of MaxiScan 2200 models configured for wand emulation will flash 4 times at power-up.
N° 131 - Analog Wand Emulation
222
MS/2200/RM/00/E/970131
Page 233
Wand emulation Predefined data transmission settings Predefined settings for Wand emulation - Interface N° 130 margin size
-
10 x narrow bar width logical signal state during transmission
- bar = 1, space = 0, margin = 0 logical signal state outside transmission
- quiet zone = 0 pulse duration
-
0.88 ms (37.5 cm/s)
In this section, the predefined parameter settings for Interface N° 130 (standard wand emulation configuration) are indicated by an asterisk (*).
Transmission delay Ð Inter-message delay
MS/2200/RM/00/E/970131
223
Page 234
Wand emulation Margin size Predefined margin size The size of the default margin is 10 times the size of the narrow bar (50 µs). 10 x Narrow Bar Width (*)
Compose margin size
Example
To set a margin size of 20 x the narrow bar width: 1. Scan Compose Margin Size. 2. Scan the desired value in narrow-bar increments - in our example we would scan 2 0 - and scan End Selection to finish ( Ð Number codes or appendix at the end of this manual).
Compose Margin Size
224
MS/2200/RM/00/E/970131
Page 235
Wand emulation Logical output signal state Examples of signal state combinations quiet zone margin
Quiet Zone = 0 (*), Bar = 1 (*)
Quiet Zone = 1, Bar = 1 (*)
Quiet Zone = 0 (*), Bar = 0
Quiet Zone = 1, Bar = 0
MS/2200/RM/00/E/970131
225
Page 236
Wand emulation Signal state outside transmission
Quiet Zone = 0 (*)
quiet zone margin
Quiet Zone = 1
226
MS/2200/RM/00/E/970131
Page 237
Wand emulation Signal state during transmission
Bar = 1, Space = 0, Margin = 0 (*)
quiet zone margin
Bar = 0, Space = 1, Margin = 1
MS/2200/RM/00/E/970131
227
Page 238
Wand emulation Pulse duration 0.88 ms (37.5 cm/s) (*)
0.19 ms (175 cm/s)
The values represent the pulse duration of a narrow bar or space. Speeds (values in parentheses) are provided for standard UPC/EAN bar codes with 0.33 mm narrow-bar elements.
Pulse duration speed calculation Actual emulated speed = [ 100 x ( r / t ) ] cm/s with r = actual narrowest element (mm) t = set-up duration element (ms)
Example
0.26 ms (125 cm/s)
228 narrowest element (r):
0.45 mm set-up duration element (t):
0.4 ms emulated speed:
100 x (0.45 / 0.4) = 112.5 cm/s
0.44 ms (75 cm/s)
MS/2200/RM/00/E/970131
Page 239
Wand emulation 0.66 ms (50 cm/s)
1.32 ms (25 cm/s)
2.64 ms (12.5 cm/s)
6.60 ms (5 cm/s)
MS/2200/RM/00/E/970131
229
Page 240
Appendix - Number codes
Appendix - Number codes 1
2
Use the number codes on the following pages to enter custom numerical values required by certain configuration codes. Scan each digit in the number and scan End Selection - once or twice as applicable - after the last digit. The same number codes are provided in another part of this manual ( Ð Number codes ).
End Selection
3
230
4
MS/2200/RM/00/E/970131