The text of a manual · part 23 of 25
MaxiScan 2200 Reference Manual, pages 221 to 230
Pages 221 to 230 of 244
The original document is the PDF (753 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2200
Page 221
Symbologies - UPC/EAN code families (*) EAN-8 Transmitted as EAN 8 (*)
MS/2200/RM/00/E/970131
EAN-8 Transmitted as EAN-13
211
Page 222
Test codes
Test codes One-dimensional symbologies Codabar
Code 39
123456
CODE-39
Code 128
EAN 128
CODE-128
(]C1)EAN 128
212
MS/2200/RM/00/E/970131
Page 223
Test codes EAN-8
EAN-13
12345670
1234567890128
UPC-A
0
01234 50000
UPC-E
7
MS/2200/RM/00/E/970131
0
0 1 2 3 4 5
7
213
Page 224
Test codes Interleaved 2 of 5
12345678901234
Matrix 2 of 5
012345
214
Standard 2 of 5
123456
MS/2200/RM/00/E/970131
Page 225
Test codes MSI Code
12345666
Plessey Code
80001495050
MS/2200/RM/00/E/970131
215
Page 226
Troubleshooting
Troubleshooting The tables in this section describe some common problems you may encounter when you use your MaxiScan 2200 (power-up, normal operation, configuration). Look for a description of your problem in the symptoms columns and try the proposed solution given in the action column. If you can not solve the problem yourself, please contact your UBI representative.
Before you contact your UBI representative . . . If you do not find a solution in the following Troubleshooting tables, you can try a general reset of the MaxiScan 2200 (Ð Reset all configuration parameters ).
If you still have a problem . . . Contact your UBI representative and give full details of the problem. Your UBI representative may ask you to provide the software version number for your MaxiScan 2200. If the MaxiScan 2200 is powered up, try to read the Software Version code to display this information on your host system screen if applicable (Ð Software version identification).
216
MS/2200/RM/00/E/970131
Page 227
Troubleshooting Power-up problems symptoms
Ð refer to)
possible causes action ( no electrical power or insufficient electrical power (especially keyboard wedge)
check power supply with MaxiScan 2200 connected.
connection problems check connections (Connection diagram for your interface)
incorrect product components (MaxiScan 2200 model, cables, external power supply as applicable)
check product part numbers, order form and invoice + Connection diagram for your interface, Interfaces red power-up LED but no power-up beeps power-up beeps deactivated activate power-up beeps (Beeps)
indicator LED flashes orange a number of times at powerup number of flashes indicate the selected interface type
• check the number of flashes for your interface (Interfaces)
• reselect correct interface number for your system if necessary (Predefined interface numbers section for your interface, Compose interface number) and reconfigure no red power-up LED / no power-up beeps continuous orange indicator LED at power-up null interface following Reset Factory Defaults scan the predefined interface number code for your system (Predefined interface numbers section for your interface) or enter the correct interface number (Compose interface number) and reconfigure error beeps from keyboard when connecting MaxiScan 2200 host system already switched on wait a few seconds - the beeps should stop
3 long beeps at power-up
EEPROM integrity error contact UBI Technical Support
MS/2200/RM/00/E/970131
217
Page 228
Troubleshooting Configuration problems symptoms possible causes
6 short beeps when reading a configuration error: configuration code • option not available no success beeps when reading a configuration code
MaxiScan 2200 reads the same configuration code more than once, does not transmit any data
• interface number not available
• optional feature not implemented
• commands not read in the correct order
• other setup errors
Ð refer to)
action ( check current action - make sure in particular that you have scanned End Selection once or twice if required for the previous parameter installation problem check MaxiScan 2200 power supply, connections (Connection diagram for your interface), product components
MaxiScan 2200 in Configuration Inhibit After 4 mn mode scan Configuration Enable Mode (Configuration modes)
insufficient time-out between identical consecutive codes increase time-out between identical consecutive codes (Data decoding security parameters)
code mark selection not taken you forgot to scan End Selection after re-enter the desired code mark (Code into account scanning the desired ASCII character mark) and scan End Selection (ASCII character codes)
3 long beeps during configuration
218 code mark value has been selected but code mark transmission is not activated.
read Code Mark Transmitted (Code mark)
EEPROM integrity error contact UBI Technical Support
MS/2200/RM/00/E/970131
Page 229
Troubleshooting Operating problems symptoms no beeps or orange LED indication during reading, no transmission poor reading performance
MS/2200/RM/00/E/970131
Ð refer to)
possible causes action ( installation problem check MaxiScan 2200 power supply, connections (Connection diagram for your interface), product components configuration problem
• check you have the correct product components (MaxiScan 2200 model, cables, CMM, external power supply as applicable)
• check you have the correct number of flashes for your interface at power-up (Interfaces)
• reselect correct interface number for your system if necessary (Predefined interface numbers section for your interface, Compose interface number)
• if you have just configured the MaxiScan 2200, make sure you have finished correctly - the MaxiScan 2200 may be waiting for an End Selection for example symbology not selected activate the required symbology (Symbologies - Activation)
symbology not supported by your MaxiScan 2200 model see the list of supported symbologies, read the appropriate test code (Test codes)
good read beep / LED deactivated activate if required (Beeps)
barcode length incompatible with MaxiScan 2200 configuration (minimum/fixed length parameter settings)
• check bar code
• change barcode length setting for your symbology (Symbologies)
MaxiScan 2200 configured for check digit and no check digit present in code
• check bar code
• change check digit configuration for your symbology if applicable (Symbologies)
dirty or damaged red reading window clean or replace as required (see MaxiScan 2200 Installation Guide)
219
Page 230
Troubleshooting Operating problems symptoms error beeps from keyboard or no manual keyboard response (keyboard wedge interface)
possible causes
Ð refer to)
action ( incorrect reading distance for your reading situation select correct reading distance (Reading distance)
incorrect resolution adjustment (video channel) for the type of codes you read select correct video channel (Resolution adjustment - Video channel selection)
incorrect scan rate select correct scan rate ( Scan rate)
disconnect MaxiScan 2200 from CMM:
• if problem disappears, the problem is with the MaxiScan 2200 check MaxiScan 2200 model and configuration
• if problem remains . . .
check all product components (MaxiScan 2200 model, cables, CMM, power supply as applicable), installation and configuration
MaxiScan 2200 reads the same bar code more than once, transmits same data insufficient time-out between identical consecutive codes increase time-out between identical consecutive codes (Data decoding security parameters)
MaxiScan 2200 reads the same bar code more than once, transmits different data insufficient time-out between different consecutive codes increase time-out between different consecutive codes (Data decoding security parameters)
insufficient number of data validation reads increase number of consecutive same reads before transmission (Data decoding security parameters)
220
MS/2200/RM/00/E/970131