Page 241
Chapter 9, Additional Access Point Features sdvars set terminate Purpose:
Sets the internal variable terminate to a specified value. Use terminate to stop a countdown process in the access point. If either starttime or nextpoweruptime is counting down, setting this variable stops the timer and halts the countdown process. Note: You should use caution when using this command. If the script file is being downloaded or executed, setting this variable interrupts the processing and can leave the access point in an undetermined state that may require user intervention.
Syntax:
sdvars set terminate sdvars set setactivepointers Purpose:
Sets the setactivepointers command to change inactive segments to active segments the next time the access point is rebooted. This command is usually used with the nextpoweruptime command.
Syntax:
sdvars set setactivepointers none/boot/data/both where:
Example:
none does not change the active segments. The default is none. Also, when the reboot is completed, the access point resets this value to none.
boot changes the inactive boot segment to the active boot segment.
data changes the inactive data segment to the active data segment.
both changes both the boot and data inactive segments to the active segments.
To change the inactive boot and data segments to active at the next reboot, enter: sdvars set setactivepointers both sdvars set nextpoweruptime Purpose:
Sets the nextpoweruptime command to set the internal variable nextpoweruptime to a countdown time so that when 0 is reached, the access point will reboot. When the nextpoweruptime counter reaches 0, the access point checks the value of the setactivepointers variable, takes the appropriate action, and then reboots. Note: If you need to terminate the reboot, you can do so by setting nextpoweruptime to 0 if it has not already been reached by the countdown. By resetting nextpoweruptime to 0, the timer is stopped so the unit does not reboot.
MobileLAN access System Manual
227
Page 242
Chapter 9, Additional Access Point Features
Syntax:
sdvars set nextpoweruptime dd:hh:mm:ss where dd:hh:mm:ss is how far in the future the reboot is to begin. dd is days.
hh is hours.
mm is minutes. ss Example:
is seconds.
To reboot the access point 2 hours from now, enter: sdvars set nextpoweruptime 00:02:00:00
Creating Script Files You can create a script file that will execute a series of commands. For example, when you upgrade the access point, you typically need to erase the appropriate file segments, download the new files, and reboot using the new software. You can create a script file to perform these commands. Script files are ASCII text files with a 32-byte file system header appended. You may need to contact your local Intermec representative for a copy of the header file called filehdr.exe. Follow these rules when creating script files: • The total file size including the header must be less than 4096 bytes, which is the size of the RAM file segment. • Each line in the script file must have fewer than 80 characters • Each line in the script file must be terminated by a line feed or carriage return. • You can only have one command per line. • You can include comments on a line by using the pound (#) sign; all characters after a pound sign are ignored. To test a script file, log onto an access point and type each of the script file commands. #Sample script file for upgrading an access point #Step 1. Delete files file sdvars set checkpoint 1 file fe ib: file fe id:
228
MobileLAN access System Manual
Page 243
Chapter 9, Additional Access Point Features
#Step 2. Get boot files file sdvars set checkpoint 2 file tftp get *\data\bootchk.dnl ib: file tftp get *\startup\uap.dnl ib: file tftp get *\startup\uapboot.dnl ib:
#Step 3. Get data files file sdvars set checkpoint 3 file tftp get *\data\bkgrnd.dnl id: file tftp get *\data\bootchk.dnl id: file tftp get *\data\discinca.dnl id: file tftp get *\data\falcon_.dnl id: file tftp get *\data\help.dnl id: file tftp get *\data\hlp.dnl id: file tftp get *\data\intermec.dnl id: file tftp get *\data\menu.dnl id: file tftp get *\data\sftdwnl.dnl id: file tftp get *\data\welcome.dnl id: file tftp get *\data\write.dnl id:
#Step 4. Set checkpoint to show completed file sdvars set checkpoint 4
MobileLAN access System Manual
229
Page 244
Chapter 9, Additional Access Point Features
230
MobileLAN access System Manual
Page 245
A
Specifications
This appendix provides specifications for reference purposes only. Actual product performance and compliance with local telecommunications regulations may vary from country to country. Intermec only ships products that are type approved in the destination country.
MobileLAN access System Manual
231
Page 246
Appendix A, Specifications
Specifications WA22
232
Height
4.6 cm (1.8 in)
Length
25.0 cm (9.8 in)
Width
15.9 cm (6.3 in)
Weight
526 g (1.16 lb)
POE electrical rating x 48V, 315 mA
Operating temperature
-20°C to +55°C (-4°F to +131°F)
Storage temperature
-40°C to +70°C (-40°F to +158°F)
Humidity (non-condensing)
10 to 90%
Architecture
Transparent bridge
Ethernet interfaces
10BaseT/100BaseTx (twisted-pair)
Ethernet compatibility
Ethernet frame types and Ethernet addressing
Ethernet data rate
10 Mbps/100 Mbps (Ethernet) 100 Mbps (Fiber optic)
Fiber optic interface (optional)
MT-RJ
Radios supported
IEEE 802.11b, IEEE 802.11a
Media Access protocol
CSMA/CD
Filters (protocol)
IP, IPX, NetBEUI, DECNET, AppleTalk
Filters (others)
IP, ARP, Novell RIP, SAP, LSP
Serial port maximum data rate
115,200 bps
Management interfaces
Web browser-based manager, text-based menu system, serial port, Telnet, SNMP
SNMP agent
RFC 1213 (MIB-2), RFC 1398 (dot3), RFC 1493 (Bridge), 802.11, 802.1x, MobileLAN access
Regulatory Approvals
EN 550022/CISPR 22 Class A; FCC Part 15 & ICES003 Class A; C tick Marked (AS 3548); CE Market, Compliant with RTT&E, EMC, LVD directives; (See separate radio approvals); UL Listed 1950 & IEC 60529-IP53; CSA Certified, C22.2 #950 & C22.3 #94-ENC 3.5; TUV Licensed, EN 60950 & EN 60529-IP53; NYCE Certified, NOM 19, plenum-rated
MobileLAN access System Manual
Page 247
Appendix A, Specifications
2101 Height
3.8 cm (1.5 in)
Length
25.0 cm (9.8 in)
Width
15.9 cm (6.3 in)
Weight
526 g (1.16 lb)
AC electrical rating
∼100 to 240V, 1.0A, 50 to 60 Hz
POE electrical rating x 48V, 315 mA
Operating temperature
-20°C to +65°C (-4°F to +149°F)
Storage temperature
-40°C to +70°C (-40°F to +158°F)
Humidity (non-condensing)
10 to 90%
Architecture
Transparent bridge
Ethernet interfaces
10BaseT/100BaseTx (twisted-pair)
Ethernet compatibility
Ethernet frame types and Ethernet addressing
Ethernet data rate
10 Mbps/100 Mbps (Ethernet) 100 Mbps (Fiber optic)
Fiber optic interface (optional)
MT-RJ
Radios supported
IEEE 802.11b, WLI-Forum OpenAir
Media Access protocol
CSMA/CD
Filters (protocol)
IP, IPX, NetBEUI, DECNET, AppleTalk
Filters (others)
IP, ARP, Novell RIP, SAP, LSP
Serial port maximum data rate
115,200 bps
Management interfaces
Web browser-based manager, text-based menu system, serial port, Telnet, SNMP
SNMP agent
RFC 1213 (MIB-2), RFC 1398 (dot3), RFC 1493 (Bridge), 802.11, 802.1x, MobileLAN access
Regulatory Approvals
FCC Part 15.247 Certified; Canada RSS 210 Certified; ETS 300 328 Type Approved; EN 55022 / CISPR 22 Class B; FCC Part 15 & ICES-003 Class A; SCT Certification, NOM-EM-121, pending AS 3548, C tick Marked; Compliant with all European Directives, CE Marked (~ETS 300 826); UL Listed, UL 1950 & IEC 60529–IP53; CSA Certified, C22.2 #950 & C22.2; #94–ENC 3.5; TUV Licensed, EN 60950 & EN 60529–IP53; NYCE Certified, NOM 19.
MobileLAN access System Manual
233
Page 248
Appendix A, Specifications
WA21 Height
9.5 cm (3.8 in)
Length
35.5 cm (14.0 in)
Width
23.6 cm (9.3 in)
Weight
2.63 kg (5.8 lb)
AC electrical rating Standard Heater (optional) POE electrical rating Operating temperature Standard Heater (optional), AC only Heater/insulated bag (optional), AC only
234
∼100 to 240V, 1.0 to 0.5A, 50 to 60 Hz ∼100 to 120V, 1.0A, 50 to 60 Hz or ∼200 to 240V, 0.5A, 50 to 60 Hz x 48V, 315 mA -25°C to +70°C (-13°F to +158°F) -30°C to +70°C (-22°F to +158°F) -30°C to 0°C (-22°F to +32°F)
Storage temperature
-40°C to +70°C (-40°F to +158°F)
Humidity (non-condensing)
10 to 90%
Industrial sealing
IP54 (NEMA 4)
Architecture
Transparent bridge
Ethernet interfaces
10BaseT/100BaseTx (twisted-pair)
Ethernet compatibility
Ethernet frame types and Ethernet addressing
Ethernet data rate
10 Mbps/100 Mbps (Ethernet) 100 Mbps (Fiber optic)
Fiber optic interface (optional)
MT-RJ
Radios supported
IEEE 802.11b, IEEE 802.11a
Media Access protocol
CSMA/CD
Filters (protocol)
IP, IPX, NetBEUI, DECNET, AppleTalk
Filters (others)
IP, ARP, Novell RIP, SAP, LSP
Serial port maximum data rate
115,200 bps
Management interfaces
Web browser-based manager, text-based menu system, serial port, Telnet, SNMP
SNMP agent
RFC 1213 (MIB-2), RFC 1398 (dot3), RFC 1493 (Bridge), 802.11, 802.1x, MobileLAN access
Regulatory Approvals
EN 55022 / CISPR 22 ClassA; FCC Part 15 & ICES003 Class A; C tick Marked (AS 3548); CE Market, compliant with RTT&E, EMC, LVD Directives (see separate radio approvals); UL listed UL 1950/C22.2 #950 IEC; 60529-IP53 and C22.2 #94-ENC 3.5; TUV Licensed, EN 60950 & EN 60539-IP53; NYCE Certified; NOM 19, plenum-rated.
MobileLAN access System Manual
Page 249
Appendix A, Specifications
2100 Height
9.5 cm (3.8 in)
Length
35.5 cm (14.0 in)
Width
23.6 cm (9.3 in)
Weight
2.63 kg (5.8 lb)
AC electrical rating Standard Heater (optional) Operating temperature Standard Heater (optional), AC only Heater/insulated bag (optional), AC only
∼100 to 240V, 1.0 to 0.5A, 50 to 60 Hz ∼100 to 120V, 1.0A, 50 to 60 Hz or ∼200 to 240V, 0.5A, 50 to 60 Hz -25°C to +70°C (-13°F to +158°F) -30°C to +70°C (-22°F to +158°F) -30°C to 0°C (-22°F to +32°F)
Storage temperature
-40°C to +70°C (-40°F to +158°F)
Humidity (non-condensing)
10 to 90%
Industrial sealing
IP54 (NEMA 4)
Architecture
Transparent bridge
Ethernet interfaces
10BaseT/100BaseTx (twisted-pair)
Ethernet compatibility
Ethernet frame types and Ethernet addressing
Ethernet data rate
10 Mbps/100 Mbps (Ethernet) 100 Mbps (Fiber optic)
Fiber optic interface (optional)
MT-RJ
Radios supported
IEEE 802.11b, WLI-Forum OpenAir, 902 MHz
Media Access protocol
CSMA/CD
Filters (protocol)
IP, IPX, NetBEUI, DECNET, AppleTalk
Filters (others)
IP, ARP, Novell RIP, SAP, LSP
Serial port maximum data rate
115,200 bps
Management interfaces
Web browser-based manager, text-based menu system, serial port, Telnet, SNMP
SNMP agent
RFC 1213 (MIB-2), RFC 1398 (dot3), RFC 1493 (Bridge), 802.11, 802.1x, MobileLAN access
MobileLAN access System Manual
235
Page 250
Appendix A, Specifications
2100 (continued) Regulatory Approvals
FCC Part 15.247 Certified; Canada RSS 210 Certified; ETS 300 328 Type Approved; EN 55022 / CISPR 22 Class A; FCC Part 15 & ICES-003 Class A; SCT Certification, NOM-EM-121; AS 3548, C tick Marked; Compliant with all European Directives, CE Marked (ETS 300 826); UL Listed, UL 1950/C22.2 #950 IEC; 60529-IP53 and C22.2 #94-ENC3.5; Nonincendive 2.4 GHz and 900 MHz antenna circuits UL Listed, UL 1604 & C22.2 #213 for Div 2; Class I– Groups A, B, C & D; Class II–Groups F & G; Class III; TÜV Licensed, EN 60950 & EN 60529-IP53; NYCE Certified, NOM 19
2102
236
Height
9.3 cm (3.7 in)
Length
14.7 cm (5.8 in)
Width
3.5 cm (1.4 in)
Weight
232 g (0.5 lb)
Electrical
∼100 to 240V, 1.0A, 50 to 60 Hz
Operating temperature
-20°C to +65°C (-4°F to +149°F)
Storage temperature
-40°C to +70°C (-40°F to +158°F)
Humidity (non-condensing)
10 to 90%
Architecture
Transparent bridge
Ethernet interfaces
10BaseT (twisted-pair)
Ethernet compatibility
Ethernet frame types and Ethernet addressing
Ethernet data rate
10 Mbps (Ethernet)
Radios supported
IEEE 802.11b, WLI-Forum OpenAir
Media Access protocol
CSMA/CD
Filters (protocol)
IP, IPX, NetBEUI, DECNET, AppleTalk
Filters (others)
IP, ARP, Novell RIP, SAP, LSP
Serial port maximum data rate
115,200 bps
Management interfaces
Web browser-based manager, text-based menu system, serial port, Telnet, SNMP
SNMP agent
RFC 1213 (MIB-2), RFC 1398 (dot3), RFC 1493 (Bridge), 802.11, 802.1x, MobileLAN access
Regulatory Approvals
FCC Part 15.247 Certified, Canada RSS 210 Certified, ETS 300 328 Type Approved, EN 55022 / CISPR 22 Class B, FCC Part 15 & ICES-003 Class A, SCT Certification, NOM-EM-121, pending, AS 3548, C tick Marked, Compliant with all European Directives, CE Marked (prETS 300 826), UL Listed, C22.2 II 950, TÜV Licensed, EN 60950, NYCE Certified, NOM 19
MobileLAN access System Manual