Page 11

Before You Begin

Before You Begin This section provides you with safety information, technical support information, and sources for additional product information.

Safety Summary Your safety is extremely important. Read and follow all warnings and cautions in this document before handling and operating Intermec equipment. You can be seriously injured, and equipment and data can be damaged if you do not follow the safety warnings and cautions.

Do not repair or adjust alone Do not repair or adjust energized equipment alone under any circumstances. Someone capable of providing first aid must always be present for your safety.

First aid Always obtain first aid or medical attention immediately after an injury. Never neglect an injury, no matter how slight it seems.

Resuscitation Begin resuscitation immediately if someone is injured and stops breathing. Any delay could result in death. To work on or near high voltage, you should be familiar with approved industrial first aid methods.

Energized equipment Never work on energized equipment unless authorized by a responsible authority. Energized electrical equipment is dangerous. Electrical shock from energized equipment can cause death. If you must perform authorized emergency work on energized equipment, be sure that you comply strictly with approved safety regulations.

MobileLAN access System Manual xi

Page 12

Before You Begin

Safety Icons This section explains how to identify and understand warnings, cautions, and notes that are in this document. A warning alerts you of an operating procedure, practice, condition, or statement that must be strictly observed to avoid death or serious injury to the persons working on the equipment. Avertissement: Un avertissement vous avertit d’une procédure de fonctionnement, d’une méthode, d’un état ou d’un rapport qui doit être strictement respecté pour éviter l’occurrence de mort ou de blessures graves aux personnes manupulant l’équipement. A caution alerts you to an operating procedure, practice, condition, or statement that must be strictly observed to prevent equipment damage or destruction, or corruption or loss of data. Attention: Une précaution vous avertit d’une procédure de fonctionnement, d’une méthode, d’un état ou d’un rapport qui doit être strictement respecté pour empêcher l’endommagement ou la destruction de l’équipement, ou l’altération ou la perte de données.

Global Services and Support Warranty Information To understand the warranty for your Intermec product, visit the Intermec web site at http://www.intermec.com and click Support > Warranty. Disclaimer of warranties: The sample code included in this document is presented for reference only. The code does not necessarily represent complete, tested programs. The code is provided “as is with all faults.” All warranties are expressly disclaimed, including the implied warranties of merchantability and fitness for a particular purpose.

Web Support Visit the Intermec web site at http://www.intermec.com to download our current manuals in PDF format. To order printed versions of the Intermec manuals, contact your local Intermec representative or distributor. Visit the Intermec technical knowledge base (Knowledge Central) at http://intermec.custhelp.com to review technical information or to request technical support for your Intermec product.

xii

MobileLAN access System Manual

Page 13

Before You Begin

Telephone Support These services are available from Intermec Technologies Corporation. In the U.S.A. and Canada call 1-800-755-5505 and choose this option

Service

Description

Factory Repair and On-site Repair

Request a return authorization number for authorized service center repair, or request an onsite repair technician.

1

Technical Support

Get technical support on your Intermec product.

2

Service Contract Status

Inquire about an existing contract, renew a contract, or ask invoicing questions.

3

Schedule Site Surveys or Installations

Schedule a site survey, or request a product or system installation.

4

Ordering Products

Talk to sales administration, place an order, or check the status of your order.

5

Outside the U.S.A. and Canada, contact your local Intermec representative.

Who Should Read This Document? This manual provides you with information about the features of the MobileLAN access products, and how to install, configure, operate, maintain, and troubleshoot them. Before you install and configure the MobileLAN access products, you should be familiar with your network and general networking terms, such as IP address.

Related Documents The Intermec web site at http://www.intermec.com contains many of our documents that you can download in PDF format. To order printed versions of the Intermec manuals, contact your local Intermec representative or distributor.

MobileLAN access System Manual xiii

Page 14

Before You Begin

Patent Information Product is covered by one or more of the following patents: 4,910,794; 5,070,536; 5,295,154; 5,349,678; 5,394,436; 5,425,051; 5,428,636; 5,483,676; 5,504,746; 5,546,397; 5,574,979; 5,592,512; 5,680,633; 5,682,299; 5,696,903; 5,740,366; 5,790,536; 5,844,893; 5,862,171; 5,940,771; 5,960,344. There may be other U.S. and foreign patents pending.

xiv

MobileLAN access System Manual

Page 15

1

Getting Started

This chapter introduces the MobileLAN™access family of access points, explains their features, and describes how you can use them to expand your data collection network. This chapter covers these topics: • Overview of the MobileLAN access family • How the access point fits in your network • Configuring the access point for the first time • Saving configuration changes

MobileLAN access System Manual

1

Page 16

Chapter 1, Getting Started

Overview of the MobileLAN access Family Intermec’s MobileLAN™access family of access points delivers reliable and seamless wireless performance to almost any operational environment. They are designed for standards-based connectivity and they support industry standard IEEE 802.11b and IEEE 802.11a wireless technologies. The 2100 supports legacy 902 MHz wireless technologies. The 2101, 2100, and 2102 support also support legacy WLI Forum OpenAir wireless technologies. ™

The 2101, WA22, 2100, WA21, or 2102 with an IEEE 802.11b radio installed is Wi-Fi® certified for interoperability with other 802.11b wireless LAN devices. The WA22, WA21, or 2106 with an IEEE 802.11a radio installed is Wi-Fi certified for interoperability with other 802.11a wireless LAN devices. The MobileLAN access family consists of these access points: • WA22 • WA21 • 2101 • 2100 • 2102 • 2106 The access point can be configured as an access point or as a point-topoint or point-to-multipoint bridge. Normally, an access point is connected to a wired local area network (LAN) and provides network access for wireless end devices. A point-to-point bridge connects two wired LANs and is often used to provide wireless communications in locations where running cable is difficult, such as across roads or between buildings. A point-to-multipoint bridge not only connects two wired LANs, but also communicates with wireless end devices. An access point can also be configured as a wireless access point (WAP) or repeater. A WAP is not connected to a wired LAN; it receives data from wireless end devices and forwards the data to an access point (that is connected to the wired LAN). A WAP is useful in areas that do not support a wired network connection.

2

MobileLAN access System Manual

Page 17

Chapter 1, Getting Started

Management and Configuration

Multiport Bridge

MIB SNMP Agent

DHCP

Forwarding Database

Spanning Tree

TCP/IP TFTP

Bridging Telnet

HTTP

File System

Wireless ARP Server

Configuration Settings

Ethernet Port

Radio Port 1

Ethernet Connector

Antenna Connectors

Radio Port 2

IP Port

Configuration Port

21XXT034.eps

RS-232 Connector

Antenna Connectors

On the left, this illustration shows the ways you can manage and configure the access point, and on the right, it shows the access point’s general multiport bridge architecture.

Access points are multiport (Ethernet-to-wireless) bridges, and because wireless end devices operate similarly to other Ethernet devices, all your existing Ethernet applications will work with the wireless network without any special networking software. Any access point, except the root access point, can concurrently receive hello messages on its Ethernet port, its radio port, and its IP tunnel port. However, an access point can use only one port to attach to the network. Port priorities are structured as follows: 1 Ethernet 2 IP tunnel 3 Radio Unlike the physical Ethernet and radio ports, the IP tunnel port does not have its own output connector. It is a logical port that provides IP encapsulation services for frames that must be routed to reach their destinations. Once frames are encapsulated, they are transmitted or received through the Ethernet or radio port. Wireless end devices may use power management to maintain battery life. These end devices periodically wake up to receive frames that arrived while their radio was powered down. The access point automatically provides a pending message delivery service that holds frames until the end device is ready to receive them.

MobileLAN access System Manual

3

Page 18

Chapter 1, Getting Started

Features This table lists the features of the various MobileLAN access products. MobileLAN access Feature Comparison Feature

4

WA22

2101

WA21

2100

2102

2106

Access Point

Yes

Yes

Yes

Yes

Yes

Yes

Point-to-Point Bridge (Wireless Bridge)

Yes

Yes

Yes

Yes

Yes

Yes

Wireless Access Point (WAP) or Repeater

Yes

Yes

Yes

Yes

No

Yes

Secure Wireless Hops (SWAP)

Yes

Yes

Yes

Yes

Yes

Yes

Secure Wireless Hops (TLS or TTLS)

Yes

Yes (2101B)

Yes

Yes (2100D)

No

Yes

Radios

802.11b, 802.11a

802.11b, OpenAir

802.11b, 802.11a

802.11b, OpenAir, 900 MHz

802.11b, OpenAir

802.11a

Dual Radio Support

Yes

Yes

Yes

Yes

No

No

Wi-Fi Compliant

Yes

Yes

Yes

Yes

Yes

Yes

802.1x Authenticator

Yes

Yes

Yes

Yes

Yes

Yes

802.1x Authentication Server

Yes

Yes (2101B)

Yes

Yes (2100D)

No

Yes

Access Control List (ACL) Server

Yes

Yes (2101B)

Yes

Yes (2100D)

Yes

Yes

Password Server

Yes

Yes

Yes

Yes

Yes

Yes

Secure Web Browser Interface (HTTPS)

Yes

Yes (2101B)

Yes

Yes (2100D)

No

Yes

10BaseT/100BaseTx

Yes

Yes (2101B)

Yes

Yes (2100D)

10BaseT

Yes

Fiber Optics Option

Yes

Yes

Yes

Yes

No

No

Serial Port

Yes

Yes

Yes

Yes

Yes

No

Data Link Tunneling

Yes

Yes

Yes

Yes

Yes

Yes

IP Tunneling

Yes

Yes

Yes

Yes

Yes

Yes

Antenna Diversity

Yes

Yes

Yes

Yes

Yes

No

Non-incentive Antenna System

Yes

No

Yes

Yes

No

No

NEMA 4/IP 54 Protection

No

No

Yes

Yes

No

No

Power Supply

No

DC

AC

AC

DC

DC

Power Over Ethernet

Yes

No

Yes

No

Yes with MobileLAN splitter

Yes with MobileLAN splitter

Heater Option

No

No

Yes

Yes

No

No

MobileLAN access System Manual

Page 19

Chapter 1, Getting Started

Other features of all access points include: • the ability to be managed by MobileLAN manager, a web browser, telnet, and SNMP. • the ability to be a DHCP server or client and a NAT server. • the ability to be an ARP server. • easy software distribution. • advanced filtering of wired data traffic. • enhanced power management for wireless end devices. • fast roaming reliability for wireless end devices. • load balancing. • IEEE 802.1x security and dynamically rotating WEP keys for 802.11b or 802.11a networks. The access point can be an authenticator and an authentication server. • basic WEP 64 or WEP 128 security for 802.11b or 802.11a radios. • the ability to upgrade over the network or serial port, if the access point has a serial port.

What’s New for Software Releases 1.90? Software release 1.90 can be installed on all MobileLAN access products. However, some features are only available on newer access points, which have a faster processor and more flash memory. Newer access points are the WA22, 2101B, WA21, 2100D, and the 2106. Note: To determine the model of your access point, from the menu choose Maintenance > About this Access Point. In the Config String field, the first five characters tell you the model. New features include these items: • Added functionality for the 802.11a radio. Wireless hops are now fully supported, a single radio can provide both master and station functionality, the radio can be configured to dynamically choose the correct frequency, statistics can be viewed. • MobileLAN access Configuration Wizard. This wizard runs on a PC that is on the same Ethernet segment as the access points. It discovers the access points, helps you configure new networks, and helps you manage previously configured networks. • Domain Name Server (DNS) support • Find This AP button to make locating access points easier • Hyperlinks to make access point configuration easier and to help identify potential configuration problems

MobileLAN access System Manual

5

Page 20

Chapter 1, Getting Started

• IP tunnel filter that supports the AirFortress™ gateway New security features include these items: • (Newer access points only) Spanning tree security for 802.1x authentication. Authentication can now be performed over wired or wireless connections using TLS or TTLS (MSCHAPv2). • VLAN support for each radio • Support for the EAP-PEAP authentication method • Configurable ACL client password • EAP-OL key message verification, which means that the access point verifies when a new WEP key is delivered to a wireless end device. If it is not delivered, the key message is resent. • Ability to configure up to six RADIUS servers • (External RADIUS servers only) Ability to configure the port number for the RADIUS client access point • Additional authentication slots (up to 60) to let more wireless end devices authenticate simultaneously • Fast roaming for Trakker Antares terminals always enabled

Understanding the LEDs The 2102 and 2106 have four LEDs; the WA22, 2101, WA21, and 2100 have five LEDs. The WA22, 2101, WA21, and 2100 have a separate LED for each of the radios. To use the LEDs to help troubleshoot the radios, see “Troubleshooting the Radios” in Chapter 8. To understand the LEDs during normal use, see the next table. LED Descriptions Icon

6

LED Power

Description Remains on when power is applied.

Wireless #1 or Radio

Flashes when a frame is transmitted or received on the radio port for the radio installed in radio slot 1.

Wireless #2 (WA22, 2101, WA21, 2100,)

Flashes when a frame is transmitted or received on the radio port for the radio installed in radio slot 2 (if a second radio is installed).

Wired LAN

Flashes when a frame is transmitted or received on the Ethernet port.

Root/error

Flashes if this device is configured as the root. May also remain on if an error is detected.

MobileLAN access System Manual