The text of a manual · part 15 of 24
21XX Universal Access Point Technical Reference Manual, pages 141 to 150
Pages 141 to 150 of 234
The original document is the PDF (982 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2100
Page 141
Managing the UAP Remotely
6
Creating INCA/IP Tunnels To create INCA/IP tunnels, you configure the root UAP to originate the tunnels, and then you specify the IP addresses of the UAPs that are to listen at the other end of each tunnel. For more information about INCA/IP and configuring INCA/IP tunnels, see Appendix B, “Understanding INCA/IP.” When you configure INCA/IP tunnels through the Web browser, you must configure the root to originate tunnels, and then you must submit the change and commit the change before the IP Addresses command appears on the screen. To create INCA/IP tunnels 1. From the Configuration menu, choose the Quick Start command and then choose the INCA/IP command. 2. Configure the Mode parameter to Originate If Root. 3. Click Submit Changes. When the Operation Complete screen appears, click Back. 4. Choose the Review/write Changes command. The Summary of Changes screen appears. 5. Confirm that the change appears. 6. Click Commit. When the Operation Complete screen appears, click Back. 7. Click Return to menus. The IP Addresses command now appears on the screen. 8. Choose the IP Addresses command. The IP Addresses screen appears.
6-11
Page 142
21XX Universal Access Point Technical Reference Manual
9. Enter the IP addresses of the UAPs that are to listen for INCA/IP tunnels. 10. Press Enter. When the Operation Complete screen appears, click Back. 11. Click Submit Changes. When the Operation Complete screen appears, click Back. 12. Choose the Review/write Changes command. The Summary of Changes screen appears. 13. Confirm that the change appears. 14. Click Commit. When the Operation Complete screen appears, click Back. The changes become effective the next time you boot the UAP.
Restoring the Factory Default Settings If you restore the factory default values during your Web browser session, be sure you reset the DHCP parameters or the IP Address, IP Subnet Mask, and IP Router parameters before you reboot the UAP. If you do not reset these parameters before you reboot, you must connect to the UAP using the serial port to reset them. To restore factory defaults 1. If you are using a DHCP or BOOTP server to assign values to the IP Address, IP Subnet Mask, and IP Router parameters, note the values in the DHCP and DHCP Server Name fields. If the UAP was assigned specific IP values and no DHCP or BOOTP server was used, note the values in the IP Address, IP Subnet Mask, and IP Router fields. 2. Choose the Review/write Changes command. The Summary of Changes screen appears. 3. Click Defaults to load the factory defaults. When the Operation Complete screen appears, click Back. 4. Choose the Return to menus command. 5. Choose the Network Configuration command. 6. Reset either the DHCP parameters or the IP parameters using the values you noted in Step 1. 7. Click Submit Changes. When the Operation Complete screen appears, click Back. 8. Choose the Review/write Changes command. The Summary of Changes screen appears. 9. Confirm that your changes appear. 10. Click Commit. When the Operation Complete screen appears, click Back. 11. Choose the Reboot command. Your UAP reboots with the factory default settings and your network parameters.
6-12
Page 143
7 Maintenance and Troubleshooting
Page 144
2
Page 145
Maintenance and Troubleshooting
7
This chapter describes the commands on the Maintenance menu and the status of the LEDs during the boot process. It also includes information on troubleshooting the radios. Some commonly asked technical support questions and answers are provided, as well as information about how to obtain help.
Understanding the Maintenance Menu From the Maintenance menu you can perform a variety of functions such as changing your password, viewing the devices that are connected to your UAP, and resetting your UAP to factory default values. [Maintenance] [Analysis Tools] [Console Command] Password
“****************”
Service Password
<Enabled>
Read Current Configurations From Flash Read Factory Default Configurations [About Intermec UAP] ?-Help
[Analysis Tools] Select this option to access the Analysis Tools menu. From this menu you can select the UAP Connections screen or the Port Statistics screen. For more information, see “Using Analysis Tools” later in this section. [Console Command] When you select this option from the Maintenance menu, you go to Console Command mode where you can manipulate the UAP files and upgrade the UAP firmware. To return to the UAP monitor from Console Command mode, type exit and press Enter. For more information about using Console Command mode, see Chapter 8, “Advanced Features.” Password You can change the password that allows access to these UAP configuration menus. The password can be up to 16 characters in length and is not case sensitive. The default is Intermec. Service Password Intermec maintains a service password so that an Intermec Service representative can configure this UAP if necessary. For example, if you forget the configuration password, the Intermec representative can access the menus using the service password. By default, the service password is enabled. If setting a service password violates your security guidelines, you can disable the service password. Note: If you set Service Password to disabled, and then you forget your configuration password, you may need to send this UAP to a Service Center to be reconfigured.
7-3
Page 146
21XX Universal Access Point Technical Reference Manual
Read Current Configurations From Flash When you select this option, the UAP loads the configuration that is presently stored in flash memory and then the Maintenance menu reappears. Read Factory Default Configurations When you select this option, the UAP reloads the factory default configurations and then the Maintenance menu reappears. To make the default settings active, you must reboot the UAP. Note: After you restore the factory defaults, you should reset the DHCP parameters or the IP Address, IP Subnet Mask, and IP Router parameters before you reboot so that you can continue to manage the UAP over the network. If you do not reset these values before you reboot, you will have to reset these parameters using the serial port. [About Intermec UAP] When you select this option, the read-only About Intermec UAP screen appears. You can obtain basic information about the firmware and memory of the UAP by viewing this screen. You need to know the firmware version of your boot code and UAP code when you call Intermec Technical Support. The boot code version displayed on the screen is the UAP Monitor code that boots your UAP. The UAP code version is the UAP Program code. [Maintenance.About Intermec UAP] Boot code version
3.05
UAP code version
3.77
Total flash memory
2097152
Total RAM
4194304
Available RAM
2171872
System up-time
4 hrs - 1 min
Press any key to exit...
Using Analysis Tools When you select the Analysis Tools command from the Maintenance menu, the following menu appears: [Maintenance.Analysis Tools] [UAP Connections] [Port Statistics] ?-Help
7-4
Page 147
Maintenance and Troubleshooting
7
Viewing UAP Connections The UAP Connections screen is a read-only screen that displays information about the devices that are communicating with the UAP. The MAC address and other information is displayed for those devices that are one hop outbound from your UAP. You should note that it may take one to two minutes for an end device to appear on the UAP Connections screen. Note: To view IP addresses on the UAP Connections screen, you must set the ARP Server Mode parameter to normal flooding or no flooding.
[Maintenance.Analysis Tools.UAP Connections] Entry
MAC Address
Type
Status (2 entries)
1
00:20:a6:30:e6:89
Term
Port=2
Age=00
IP=150.40.10.19
2
00:20:a6:31:84:75
Term
Port=2
Age=00
IP=150.40.10.20
Press any key to exit...
These categories of devices display in the type column on the UAP Connections screen: Type
Explanation
Term
Terminal or end device
WAP
A wireless access point
AP
An access point configured to listen for an INCA/IP tunnel
AP-Tnl
An access point configured to originate an INCA/IP tunnel (root AP)
Ehost
Ethernet host on a secondary LAN
7-5
Page 148
21XX Universal Access Point Technical Reference Manual
Viewing Port Statistics The Port Statistics screen is a read-only screen that displays total transmitted and received frames and bytes for each port since the UAP was last powered up. [Maintenance.Analysis Tools.Port Statistics] Port
Ethernet
OpenAir-A
INCA/IP
Total Frames
0
0
0
Good Frames
0
0
0
Received Frames:
Unicast Frames
0
0
0
(Multi/Broad)cast Frames
0
0
0
Relayed Frames
0
0
0
Discarded Frames
0
0
0
Total Bytes
0
0
0
Total Frames
0
0
0
Good Frames
0
0
0
Unicast Frames
0
0
0
(Multi/Broad)cast Frames
0
0
0
Relayed Frames
0
0
0
Discarded Frames
0
0
0
Total Bytes
0
0
0
Transmitted Frames
Press any key to exit...
Understanding the LED Lighting Sequence When the UAP is powered on, the LEDs flash as the UAP boots and performs internal diagnostics. The table below describes the LED activity during the boot process.
7-6
Power
Wireless #1
Wireless #2
Wired LAN
Root/ Error
Description
On
Off
Off
Off
On
Flash checksum being calculated.
On
On
Off
Off
On
Flash checksum failure.
On
Off
Off
On
Off
RAM test in progress.
On
On
Off
On
Off
RAM test failure.
On
Off
On
Off
Off
Loading of monitor in progress.
On
Off
On
Off
On
Ethernet test in progress.
On
On
On
Off
On
Ethernet test failure.
Page 149
Maintenance and Troubleshooting
7
After the UAP successfully boots, the LEDs display the following pattern: Power
Wireless #1
Wireless #2
Wired LAN
Root/Error
On
Flashes
Flashes (if radio installed)
Flashes
Flashes if this UAP is configured as the root.
Troubleshooting the Radios If the radio is faulty or the configuration matrix string is incorrect, the LEDs on the UAP display the following pattern after the UAP boots: Power
Wireless #1
Wireless #2
Wired LAN
Root/Error
On
Off
Off
On
On
If you are connected to the UAP through its serial port, an error message also appears on your terminal or PC. The error messages are described here. In the following table, radio A refers to the radio in slot 1, and radio B refers to the radio in slot 2. These error messages may appear for either radio A or radio B. Error Message
Explanation
Couldn’t read country code from radio A
The radio may be faulty. Contact your Intermec representative.
Radio A has unknown country code
The radio may have been configured incorrectly at the factory. Contact your Intermec representative.
Invalid country code in string for radio A
The country code in the configuration matrix string does not match the country code in the radio in the UAP. Contact your Intermec representative.
Radio string doesn’t match radios installed
When this error message appears, additional information appears on the screen. For example, “Expected 504,000 but found 491 in slot A, nothing in slot B” may appear. You may have a faulty radio - contact your Intermec representative.
7-7
Page 150
21XX Universal Access Point Technical Reference Manual
Commonly Asked Technical Support Questions Problem/Symptom/Question
Possible Solution/Answer
Is the UAP fully booted?
The Power LED remains steady green and the Wired LAN LED flashes when the UAP is fully booted.
The Power LED is not on.
You may have a hardware problem with your UAP.
I cannot configure the UAP locally using the serial port.
1.
Unplug the UAP and then plug it back in to cycle the power. Verify that the Power LED remains on.
2.
Call Intermec Technical Support.
1.
Verify that you are using a null-modem cable to connect the UAP to your terminal or PC.
2.
Verify that the terminal or PC is set to 9600, N, 8, 1, no flow control.
3. Your system may be in autobaud mode. Reboot and press a key once per second until the signon screen appears. I cannot ping or Telnet to my new UAP.
The UAP does not come with a default IP address. Before you can remotely connect to it, you must set an IP address and subnet mask using the serial port.
The end device cannot connect to the network.
•
Choose Analysis Tools from the Maintenance menu, and then choose UAP Connections. Verify that the MAC address of your end device displays on the screen. If the MAC address of your device does not appear, your device is not communicating with the UAP. Check your radio configuration settings.
•
Verify the UAP is not filtering out the type of traffic you are trying to pass through it.
The end device cannot synch to the UAP.
If you are using 900 MHz Falcon radios: •
Verify that the end device and UAP have the same LAN ID and mode-channel.
If you are using 2.4 GHz OpenAir radios: 1.
Verify that the end device and UAP have the same LAN ID, security ID, channel, and subchannel.
2.
Verify that the UAP is configured as a master and the end device is configured as a station.
If you are using IEEE 802.11 radios: •
Verify that the end device and UAP have the same frequency and network name.
If you are using UHF radios: •
7-8
Verify that the end device and UAP have the same frequency.