For the Intermec 1470
Page 131
Symbologies
4
When Check Digit is set to Validate and Transmit, the imager will only read Interleaved 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data. In the 2 of 5/93 tab of Visual Menu, choose a Check Character setting under Interleaved 2/5. Click the Write Settings to Device button ( imager.
) to send the new setting to the
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). Validate but Don’t Transmit
Validate and Transmit
No Check Digit*
4-21
Page 132
1470/1471 Imager User’s Manual
IATA 2 of 5 For the default settings, see Chapter 7, “Default Charts.” In the Other Linears tab of Visual Menu, click Default under IATA 2/5. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan the following bar code. Default All IATA 2 of 5 Settings
IATA 2 of 5 On/Off In the Other Linears tab of Visual Menu, choose Decoding On under IATA 2/5. Click the Write Settings to Device button (
4-22
) to send the new setting to the imager.
Page 133
Symbologies
4
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). On
Off*
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the imager will issue an error beep. You may wish to set the same value for minimum and maximum length to force the imager to read fixed length bar code data. This configuration helps reduce the chances of a misread.
Example Decode only those bar codes with a count of 9-20 characters. Minimum length = 09 Maximum length = 20
Example Decode only those bar codes with a count of 15 characters. Minimum length = 15 Maximum length = 15 In the Other Linears tab of Visual Menu, enter the minimum message length in the Minimum Length field and the maximum message length in the Maximum Length field under IATA 2/5. Click the Write Settings to Device button ( setting to the imager.
) to send the new
4-23
Page 134
1470/1471 Imager User’s Manual
Or scan one of the following bar codes. Minimum Message Length
Maximum Message Length
After reading this programming bar code, you must input the desired message length and Save. Refer to the “General Programming Chart” in Appendix B.
MSI For the default settings, see Chapter 7, “Default Charts.” Default All MSI Settings
MSI On/Off The default setting is marked with an asterisk (*). On
Off*
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the imager will issue an error beep. You may wish to set the same value for minimum and maximum length to force the imager to read fixed length bar code data. This configuration helps reduce the chances of a misread.
Example Decode only those bar codes with a count of 9-20 characters. Minimum length = 09 Maximum length = 20
4-24
Page 135
Symbologies
4
Example Decode only those bar codes with a count of 15 characters. Minimum length = 15 Maximum length = 15 Minimum Message Length
Maximum Message Length
The desired message length and Save must be input after reading this programming bar code. Refer to the “General Programming Chart” in Appendix B.
Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. In the Other Linears tab of Visual Menu, choose Check Character Transmit under MSI. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). Transmit Check Digit
Don’t Transmit Check Digit*
4-25
Page 136
1470/1471 Imager User’s Manual
Code 93 For the default settings, see Chapter 7, “Default Charts.” In the 2 of 5/93 tab of Visual Menu, click Default under Code 93. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan the following bar code. Default All Code 93 Settings
Code 93 On/Off In the 2 of 5/93 tab of Visual Menu, choose Decoding On under Code 93. Click the Write Settings to Device button (
4-26
) to send the new setting to the imager.
Page 137
Symbologies
4
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). On
Off*
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the imager will issue an error beep. You may wish to set the same value for minimum and maximum length to force the imager to read fixed length bar code data. This configuration helps reduce the chances of a misread.
Example Decode only those bar codes with a count of 9-20 characters. Minimum length = 09 Maximum length = 20
Example Decode only those bar codes with a count of 15 characters. Minimum length = 15 Maximum length = 15 In the 2 of 5/93 tab of Visual Menu, enter the minimum message length in the Minimum Length field and the maximum message length in the Maximum Length field under Code 93. Click the Write Settings to Device button ( imager.
) to send the new setting to the
4-27
Page 138
1470/1471 Imager User’s Manual
Or scan one of the following bar codes. Minimum Message Length
Maximum Message Length
The desired message length and Save must be input after reading this programming bar code. Refer to the “General Programming Chart” in Appendix B.
Code 128 For the default settings, see Chapter 7, “Default Charts.” In the CBAR/39/128 tab of Visual Menu, click Default under Code 128. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan the following bar code. Default All Code 128 Settings
4-28
Page 139
Symbologies
4
Code 128 On/Off In the CBAR/39/128 tab of Visual Menu, choose Decoding On under Code 128. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). On*
Off
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the imager will issue an error beep. You may wish to set the same value for minimum and maximum length to force the imager to read fixed length bar code data. This configuration helps reduce the chances of a misread.
Example Decode only those bar codes with a count of 9-20 characters. Minimum length = 09 Maximum length = 20
Example Decode only those bar codes with a count of 15 characters. Minimum length = 15 Maximum length = 15
4-29
Page 140
1470/1471 Imager User’s Manual
In the CBAR/39/128 tab of Visual Menu, enter the minimum message length in the Minimum Length field and the maximum message length in the Maximum Length field under Code 128. Click the Write Settings to Device button ( to the imager.
) to send the new setting
Or scan one of the following bar codes. Minimum Message Length
Maximum Message Length
The desired message length and Save must be input after reading this programming bar code. Refer to the “General Programming Chart” in Appendix B.
4-30