The text of a manual · part 14 of 35
1470/1471 Imager User's Manual: Chapter 4 Symbologies, pages 121 to 130
Pages 121 to 130 of 316, from 1470/1471 Imager User's Manual
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 1470
Page 121
Symbologies
4
Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit or not transmit Start/Stop characters. In the CBAR/39/128 tab of Visual Menu, choose Transmit Start/Stop Characters under Code 39. Click the Write Settings to Device button ( imager.
) to send the new setting to the
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). Transmit
Don’t Transmit*
4-11
Page 122
1470/1471 Imager User’s Manual
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the imager will issue an error beep. You may wish to set the same value for minimum and maximum length to force the imager to read fixed length bar code data. This configuration helps reduce the chances of a misread.
Example Decode only those bar codes with a count of 9-20 characters. Minimum length = 09 Maximum length = 20
Example Decode only those bar codes with a count of 15 characters. Minimum length = 15 Maximum length = 15 In the CBAR/39/128 tab of Visual Menu, enter the minimum message length in the Minimum Length field and the maximum message length in the Maximum Length field under Code 39. Click the Write Settings to Device button ( to the imager.
4-12
) to send the new setting
Page 123
4
Symbologies
Or scan one of the following bar codes. Minimum Message Length
Maximum Message Length
The desired message length and Save must be input after reading this programming bar code. Refer to the “General Programming Chart” in Appendix B.
Full ASCII If Full ASCII Code 39 decoding is turned on, certain character pairs within the bar code will be interpreted as a single character. For example, $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. The following table shows certain characters on the right and their Code 39 equivalents on the left.
ASCII Characters and Code 39 Equivalents NUL
%U
DLE
$P
SP
SPACE
0
0
@
%V
P
P
‘
W p
+P
SOH
$A
DC1
$Q
!
/A
1
1
A
A
Q
Q a
+A q
+Q
STX
$B
DC2
$R
“
/B
2
2
B
B
R
R b
+B r
+R
ETX
$C
DC3
$S
#
/C
3
3
C
C
S
S c
+C s
+S
EOT
$D
DC4
$T
$
/D
4
4
D
D
T
T d
+D t
+T
ENQ
$E
NAK
$U
%
/E
5
5
E
E
U
U e
+E u
+U
ACK
$F
SYN
$V
&
/F
6
6
F
F
V
V f
+F v
+V
BEL
$G
ETB
$W
‘
/G
7
7
G
G
W
W g
+G w
+W
BS
$H
CAN
$X
(
/H
8
8
H
H
X
X h
+H x
+X
HT
$I
EM
$Y
)
/I
9
9
I
I
Y
Y
I
+I y
+Y
LF
$J
SUB
$Z
*
/J
:
/Z
J
J
Z
Z j
+J z
+Z
VT
$K
ESC
%A
+
/K
;
%F
K
K
[
%K k
+K
{
%P
FF
$L
FS
%B
,
/L
<
%G
L
L
\
%L l
+L
|
%Q
CR
$M
GS
%C
-
-
=
%H
M
M
]
%M m
+M
}
%R
SO
$N
RS
%D
.
.
>
%I
N
N
^
%N n
+N
~
%S
SI
$O
US
%E
/
/O
?
%J
O
O
_
%0 o
+O
DEL
%T
Character pairs /M and /N decode as a minus sign and period respectively. Character pairs /P through /Y decode as 0 through 9.
4-13
Page 124
1470/1471 Imager User’s Manual
In the CBAR/39/128 tab of Visual Menu, choose Full ASCII Mode under Code 39. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). Full ASCII On
4-14
Full ASCII Off*
Page 125
Symbologies
4
Check Character No Check Character indicates that the imager reads and transmits bar code data with or without a check character. When Check Character is set to Validate but Don’t Transmit, the imager will only read Code 39 bar codes printed with a check character but will not transmit the check character with the scanned data. When Check Character is set to Validate and Transmit, the imager will only read Code 39 bar codes printed with a check character and will transmit this character at the end of the scanned data. In the CBAR/39/128 tab of Visual Menu, choose a Check Character setting under Code 39. Click the Write Settings to Device button ( imager.
) to send the new setting to the
4-15
Page 126
1470/1471 Imager User’s Manual
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). Validate but Don’t Transmit
Validate and Transmit
No Check Character*
Code 11 For the default settings, see Chapter 7, “Default Charts.” Default All Code 11 Settings
Code 11 On/Off The default setting is marked with an asterisk (*). On
4-16
Off*
Page 127
Symbologies
4
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the imager will issue an error beep. You may wish to set the same value for minimum and maximum length to force the imager to read fixed length bar code data. This configuration helps reduce the chances of a misread.
Example Decode only those bar codes with a count of 9-20 characters. Minimum length = 09 Maximum length = 20
Example Decode only those bar codes with a count of 15 characters. Minimum length = 15 Maximum length = 15 Minimum Message Length
Maximum Message Length
The desired message length and Save must be input after reading this programming bar code. Refer to the “General Programming Chart” in Appendix B.
Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes. In the Other Linears tab of Visual Menu, enter 1 or 2 in the Number of Check Digits field under Code 11. Click the Write Settings to Device button ( setting to the imager.
) to send the new
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). One Check Digit
Two Check Digits*
4-17
Page 128
1470/1471 Imager User’s Manual
Interleaved 2 of 5 For the default settings, see Chapter 7, “Default Charts.” In the 2 of 5/93 tab of Visual Menu, click Default under Interleaved 2/5. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan the following bar code. Default All Interleaved 2 of 5 Settings
4-18
Page 129
Symbologies
4
Interleaved 2 of 5 On/Off In the 2 of 5/93 tab of Visual Menu, choose Decoding On under Interleaved 2/5. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). On*
Of
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the imager will issue an error beep. You may wish to set the same value for minimum and maximum length to force the imager to read fixed length bar code data. This configuration helps reduce the chances of a misread.
Example Decode only those bar codes with a count of 9-20 characters. Minimum length = 09 Maximum length = 20
4-19
Page 130
1470/1471 Imager User’s Manual
Example Decode only those bar codes with a count of 15 characters. Minimum length = 15 Maximum length = 15 In the 2 of 5/93 tab of Visual Menu, enter the minimum message length in the Minimum Length field and the maximum message length in the Maximum Length field under Interleaved 2/5. Click the Write Settings to Device button ( to the imager.
) to send the new setting
Or scan one of the following bar codes. Minimum Message Length
Maximum Message Length
The desired message length and Save must be input after reading this programming bar code. Refer to the “General Programming Chart” in Appendix B.
Check Digit When Check Digit is set to Validate but Don’t Transmit, the imager will only read Interleaved 2 of 5 bar codes printed with a check digit but will not transmit the check digit with the scanned data.
4-20