The text of a manual · part 5 of 6
Online Verifier Kit Installation Guide for EasyCoder 3400e, 4420, and 4440 Printers, pages 41 to 50
Pages 41 to 50 of 58
The original document is the PDF (5.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Intermec 073981
Page 41
Adjusting the Position of the OLV for Ladder Bar Codes To make sure that the OLV scans the ladder bar codes at the correct size and in the correct orientation, you need to use the alignment guide, ScanVision, and the calibration bar code as described next. Following this procedure, you also specify the start and stop position of the scan. The Ladder Direction Bar Code Alignment Guide can help you set the start and stop position relatively close to the tear bar. If your print job requires a start and stop position further from the tear bar, you may need to adjust the position of the OLV without using the alignment guide. Note: If you are printing picket fence bar codes, do not perform these steps. Skip ahead to “Calibrating the OLV” on page 46. To position the OLV for ladder bar codes 1 Rotate the OLV 90° so that the laser beam is aimed to strike a ladder direction bar code. For help, see the illustration on the next page. 2 Use the Ladder Direction Bar Code Alignment Guide to position the OLV. See the callouts on the alignment guide for help: a Rest the bottom edge on the horizontal base. b Place the notch against the tear bar. c Align the guide against the side of the OLV that contains the laser exit window, along the edge closest to the double socket arm.
Online Verifier Kit Installation Guide
41
Page 42
Fee d/P aus e
Pow Ale Em er/D ata rt pty
/Pa use
Interm
4420 ec
To power Ladder direction bar code alignment guide
3 Loosen the T-knob just enough to allow you to adjust the OLV so that the laser exit window aligns with the cutout edge of the guide. Note: You may need to rotate the RAM mount so that the T-knob is 30° down instead of pointing straight up. 4 Tighten the T-knob to secure the OLV in place. Do not let the OLV move as you tighten the T-knob. 5 Carefully replace the media cover on the printer. Note: You may need to adjust the position of the new bezel and plate if the plate hits the label taken sensor (for self strip) or blocks the path of the laser beam. To adjust the position, change the location of the screws in the slots in the new bezel and plate. For help, see Steps 3 and 4 of the procedure that starts on page 21. 6 Click the Transmit String button String dialog box.
42 to open the Transmit
Online Verifier Kit Installation Guide
Page 43
7 Enter ∼Lp0 and then click Transmit to turn off partial decodes. Close the Transmit String dialog box. 8 From the Advanced menu, select Toggle Additional Results. Additional values should now appear on the bottom of the screen including Max Gain and Hor Pos. 9 Place the calibration bar code under the laser beam in the same position as your bar code will appear on the label during your next print job. Make sure the end of the bar code furthest from the tear bar is positioned approximately where your bar code will start. This will be the start position of the scan. Note: You may need to insert the calibration bar code under the printhead to make sure that the laser beam is on the bar code. Raise the printhead, insert the calibration bar code between the printhead and main platen, and close the printhead. Note: You can gently crease the calibration bar code so that it slopes away from the tear bar parallel to the OLV laser exit window. 10 Click the Induce a new bar code analysis button The Bar Code Analysis screen refreshes.
.
Online Verifier Kit Installation Guide
43
Page 44
The X (mils) parameter contains the X dimension.
11 Make sure the X dimension shown in the bottom of the Bar Code Analysis screen is within ± 0.1 mil of 10 mils, which is the size of the calibration bar code. • If the X dimension is too large, move the OLV up (away from the bar code). • If the X dimension is too small, move the OLV down (toward the bar code). 12 Make note of the value shown in the Hor Pos field. This value indicates the start position of the scan. 13 Move the calibration bar code closer to the tear bar. Make sure the end of the bar code closest to the tear bar is approximately where your bar code will end. This will be the stop position of the scan 14 Click the Induce a new bar code analysis button The Bar Code Analysis screen refreshes.
.
15 Make sure the X dimension is still correct, as described in Step 11. 16 Make note of the value shown in the Hor Pos field. This value indicates the stop position of the scan.
44
Online Verifier Kit Installation Guide
Page 45
17 From the Setup menu, choose Ladder Mode. The Set to Ladder Mode dialog box appears.
18 Click Continue. A dialog box appears telling you ScanVision is setting the OLV to Ladder Mode and then the Ladder Position dialog box appears.
19 Type the value you noted in Step 12 in the Set the ladder Start position field. This should be the smaller of the two values you recorded. 20 Type the value you noted in Step 16 in the Set the ladder Stop position field. This should be the larger of the two values you recorded. 21 Click OK. 22 If you want to enable partial decodes, from the main menu select Transmit String, enter ∼Lp1, and then click Transmit. Close the Transmit String dialog box. The OLV is now ready to scan ladder bar codes. Your next step is to calibrate the OLV, as described in the next section. Online Verifier Kit Installation Guide
45
Page 46
Calibrating the OLV You need to calibrate the OLV to make sure the scanning distance and orientation of your labels is acceptable.
1 Run ScanVision. 2 From the Setup menu, select Moving Codes Mode. 3 From the Setup menu, select Picket Fence Mode. 4 Make sure the calibration bar code is still under the laser beam in the same position that your bar codes will appear on the label.
5 Press and hold the Reset button until the Calibration LED begins to flash, and then release the Reset button.
6 Wait for the laser beam and the Calibration LED to turn off, which indicates that the OLV is calibrated.
7 Remove the calibration bar code. 8 Press and release the Reset button to turn the laser beam on.
Fine Tuning Your Reflectance Profile If you were unable to achieve a good reflectance profile when adjusting the position of the OLV, or if you use flood-coated media, you need to follow the instructions in this section. Specifically, this section lets you adjust the way ScanVision converts the analog input to its digital output. You set a new value for gain and offset, which affect the reflectance profile as follows: • Gain controls the amplitude (height) of the reflectance profile. A high value creates a taller profile. • Offset controls placement of the reflectance profile on the graph. A high value moves the profile lower. To adjust the gain and offset 1 From ScanVision, click the Transmit String button open the Transmit String dialog box.
to
2 Enter ∼HT in the first blank field on the left side of the dialog box. 46
Online Verifier Kit Installation Guide
Page 47
3 Click Transmit. ScanVision responds by displaying the current OLV parameters on the right side of the dialog box.
The [DACs] line specifies the gain (177) and offset (145).
4 In the screen shown above, locate the line that reads: [DACs]= 177 145 255 255
The 177 is the gain setting and the 145 is the offset setting.
Online Verifier Kit Installation Guide
47
Page 48
5 To change the gain setting, enter ∼Hd101aaa into the next blank field, where aaa is the new value for the gain setting: • If the reflectance profile does not cover at least six lines on the graph, it is not tall enough. The aaa value needs to be increased. Try increasing it by 25. In this example, the value would go from 177 to 205. The maximum is 225. • If the reflectance profile covers more than six lines on the graph, it is too tall. The aaa value needs to be decreased. Try decreasing it by 25. In this example, the value would go from 177 to 152. 6 To change the offset setting, enter ∼Hd201bbb into the next blank field, where bbb is the new value for the offset setting: • If the reflectance profile is located above the upper yellow line on the graph, it is too high. The bbb value needs to be decreased. Try decreasing it by 25. In this example, the value would go from 145 to 120. • If the reflectance profile is located below the lower yellow line on the graph, it is too low. The bbb value needs to be increased. Try increasing it by 25. In this example, the value would go from 145 to 170. 7 Press F3 to produce a new reflectance profile and see the effect of the new values. 8 Repeat Steps 3 through 7, changing the gain and offset values until the reflectance profile is good. 9 In the Transmit String dialog box, enter ∼Hx and click Transmit to save the new gain and offset settings. The OLV will use these new settings when you turn it on.
48
Online Verifier Kit Installation Guide
Page 49
Designing and Printing Bar Code Labels When you use the OLV, you need to follow these limitations for the design and printing of bar code labels.
Media Limitations For best results with the OLV, print black bar codes onto white labels. Do not use metallic media with the OLV. You may achieve acceptable results using flood-coated media with the OLV. Using flood-coated media requires additional steps during installation, as described in “Fine Tuning Your Reflectance Profile” on page 46.
Minimum Label Length If you use Reprint Mode, the minimum label length is 12.7 mm (0.5 in). If you use No Reprint Mode, the minimum label length is 25.4 mm (1 in).
Configuring the Number of Bar Codes Per Label You need to configure the OLV with the minimum number of bar codes to be verified on each label. This number may need to change for each print job you perform. To configure this parameter, you can choose one of these methods: • Using ScanVision, select the Setup menu and choose Minimum Codes per Sync to set the number. • Using the default IntermecOLV.cfg configuration file, set the parameter to one bar code per label. Or create customized configuration files that set the parameter to different values. For help, see “Sending the Configuration File to the OLV” on page 30.
Maximum Number of Bar Codes Per Label If you are printing picket fence direction bar codes, you can fit up to four bar codes across (width) and twelve bar codes down (length), totaling up to 48 bar codes per label. Online Verifier Kit Installation Guide
49
Page 50
If you are printing ladder direction bar codes, you can verify one bar code on each label.
No Reprint Mode In No Reprint Mode, the start and stop of the OLV scan is controlled by the beginning and end of the image being printed, not by the beginning and end of the physical label. The OLV stops scanning when the last line of the image has been printed. In a typical printer, there is approximately 17 mm (2/3 in) of space between the OLV scan line and the printhead. That means that the last 17 mm (2/3 in) of the printed image does not pass under the laser beam, so it is not scanned by the OLV.
17 mm (2/3 in)
Printhead
Laser beam
Tear bar
Setting up the OLV for No Reprint Mode
When you design a label to be printed in No Reprint Mode, make sure that you do not place any bar codes in the last 17 mm (2/3 in) of the printed image. 50
Online Verifier Kit Installation Guide