The text of a manual · part 4 of 6
Online Verifier Kit Installation Guide for EasyCoder 3400e, 4420, and 4440 Printers, pages 31 to 40
Pages 31 to 40 of 58
The original document is the PDF (5.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Intermec 073981
Page 31
Note: An OLV purchased through Intermec Product Links already contains the correct initial configuration. You do not need to send the configuration file to the OLV. However, you should continue reading this section to determine if you need to create a customized configuration file. You use ScanVision to send this file to the OLV and to create a customized configuration file for each type of print job you perform. To send the configuration file to the OLV
1 Insert the SV100 Online Verifier Kit CD into the CD drive of your PC. The SV100 Online Verifier Kit window appears. Minimize this window.
2 Run ScanVision. 3 Press Ctrl-Shift-F5. 4 If a password is requested, type doorknock and click Close. The Verifier Configuration Setup screen appears. The values on this screen are the factory defaults for the OLV. Ignore these values.
Online Verifier Kit Installation Guide
31
Page 32
5 From the File menu, choose Open. 6 Browse to the Software directory on your CD drive. 7 Select the IntermecOLV.cfg file and click the Open button. The values in the IntermecOLV.cfg file appear in the fields on the Verifier Configuration Setup screen.
8 Make sure that the Command transmissions for unit dependent parameters at the bottom of the screen is set to Disable.
9 Click the Send ALL button. 10 Click the Permanent button. 11 Click the Return button. The IntermecOLV.cfg parameters have now been sent to the OLV.
12 Remove the CD from the CD drive. To create a customized configuration file
1 Run ScanVision. 2 Press Ctrl-Shift-F5. 3 If a password is requested, type doorknock and click Close. The Verifier Configuration Setup screen appears.
4 Click the Query button to retrieve the OLV’s configuration settings. Any values differing between the file on the screen and the OLV are marked with a red X.
5 Enter new parameter settings, as needed. See the table on the next page for help.
6 Make sure Command transmissions for unit dependent parameters at the bottom of the screen is set to Disable.
7 Click the Send ALL button to send the new values to the OLV.
8 Click the Query button to retrieve the OLV’s configuration settings. Any values differing between the file on the screen and the OLV are marked with a red X. Resolve any differences before proceeding.
32
Online Verifier Kit Installation Guide
Page 33
9 From the File menu, choose SaveAs to save these configuration settings in a new configuration file. The SaveAs Verifier Configuration File dialog box appears.
10 Specify the name of the new configuration file and click the Save button. IntermecOLV.cfg Configuration File Parameters Parameter
Description
Settings
~LN
Sets the minimum number of bar codes per label.
01 to 48 for picket fence bar codes
The default is 01 (one bar code per label).
01 for ladder bar codes
Sets the overall passing grade. For example, if you set this parameter to 32, the OLV fails any bar code with an ANSI Symbol grade of 3.1 or lower.
00 to 40
~LA
The default is 00 (disabled). ~LS
Sets the minimum number of good scans for a valid read.
02 to 99
The default is 02 (two scans). ~LT
Enables or disables partials at the decoder level for Interleaved 2 of 5 codes only.
0 = disable 1 = enable
The default is 0 (disabled). ~LP
Enables or disables partials at the decoder level for all symbologies.
0 = disable 1 = enable
The default is 0 (disabled). ~LV
Controls how the OLV uses the LEDs to indicate error conditions. Make sure this parameter is set to 02.
02 = Mode 02 Do not modify this parameter.
The default is 02 (Mode 2). ~HL
Sets the bar code direction to picket fence or ladder.
0 = picket fence 1 = ladder
The default is 0 (picket fence).
Online Verifier Kit Installation Guide
33
Page 34
Adjusting and Calibrating the OLV You need to perform these tasks when installing the online verifier kit for the first time and also when you start a new print job with different media or with bar codes printed in a new location or orientation: • Identify picket fence and ladder bar codes. • Position the OLV for picket fence or ladder bar codes. • Calibrate the OLV. • (Optional) Fine tune your reflectance profile.
Identifying Picket Fence and Ladder Bar Codes You need to identify the orientation of the bar code as it travels through the laser beam. You can set up the OLV to read picket fence bar codes or ladder bar codes, but not both at the same time.
Picket fence direction
Fee d/P aus e
Pow er/D ata Ale rt
*W
Em pty /Pa use
IN
*W
IN
*
*
Interm
4420 ec
Picket Fence Direction Bar Code
Note: Although this illustration (and the next one) show the media cover on the printer, your printer should not have the media cover on yet.
34
Online Verifier Kit Installation Guide
Page 35
Fee
Pow Ale d/P er/D aus e ata rt pty
/Pa use
*W
IN
*
IN
*
Em
*W
Ladder direction
Interm
4420 ec
Ladder Direction Bar Code
Your next step is to adjust the position of the OLV: • To print picket fence bar codes, follow the steps in the next section, “Adjusting the Position of the OLV for Picket Fence Bar Codes.” • To print ladder bar codes, follow the steps in “Adjusting the Position of the OLV for Ladder Bar Codes” on page 41.
Adjusting the Position of the OLV for Picket Fence Bar Codes To make sure that the OLV scans the picket fence bar codes at the correct size and in the correct orientation, you need to use the alignment guide, ScanVision, and the calibration bar code as described next. Note: To print ladder bar codes, skip ahead to “Adjusting the Position of the OLV for Ladder Bar Codes” on page 41. To position the OLV for picket fence bar codes
1 Position the Picket Fence Bar Code Alignment Guide so that the slots fit on the cross beams on the right side of the horizontal base and the notch fits against the printer tear bar. For help, see the callouts on the alignment guide. Online Verifier Kit Installation Guide
35
Page 36
Picket fence direction bar code alignment guide
Fee d/P aus e
Pow Ale er/D ata rt
Em pty
/Pa use
Interm
4420 ec
To power
2 Loosen the T-knob just enough to allow you to adjust the OLV so the laser exit window presses against the cutout section of the alignment guide, where indicated by the callout on the alignment guide.
3 Adjust the position of the OLV until the laser beam is projected onto the printer tear bar. Do not allow the weight of the OLV to bend the alignment guide. Note: If you print self-strip bar codes, the label taken sensor is installed on the tear bar. You need to position the laser beam in front of the tear bar instead of directly on it.
4 Repeat Steps 1 through 3 with the alignment guide placed at the left side of the horizontal base. When the laser beam is on the tear bar, you have come close to achieving the correct scanning angle of 10 to 34 degrees and the correct mounting distance of 20.32 cm (8 in), as shown in the next illustration.
36
Online Verifier Kit Installation Guide
Page 37
Scanning angle 0º 10º to 34º Feed /Pau se
Pow er/D ata Aler t
*W
Emp ty/P ause
*W
IN
*
IN
*
Interme
4420 c
OLV
Laser beam 20.32 cm (8 in) Media
5 Tighten the T-knob to secure the OLV in place. Do not let the OLV move as you tighten the T-knob.
6 Place the calibration bar code under the laser beam in the same position as your bar codes will appear on the label. Make sure that the laser beam is still aimed at the tear bar. The Read LED lights when the OLV can read the bar code. Note: You may need to insert the calibration bar code under the printhead to make sure that the laser beam is on the bar code. Raise the printhead, insert the calibration bar code between the printhead and main platen, and close the printhead. Note: If you need to place the calibration bar code to the far left, close to the vertical arm, you may need to fold the card on which the calibration bar code is printed. Make sure to leave enough blank space to the left of the bar code for the quiet zone (100 mils or about 1/8 in).
Online Verifier Kit Installation Guide
37
Page 38
Note: If you cannot position the laser beam so that it appears across the entire calibration bar code, you may need to adjust the position of the vertical arm.
7 Carefully place the media cover back onto the printer. Note: You may need to adjust the position of the new bezel and plate if the plate hits the label taken sensor (for self strip) or blocks the path of the laser beam. To adjust the position, change the location of the screws in the slots in the new bezel and plate. For help, see Steps 3 and 4 of the procedure that starts on page 21.
8 From the Support menu, select Reflectance Profile. Or press F3. The Reflectance Profile dialog box appears. A good reflectance profile shows a scan with consistent amplitude (height), and the amplitude occurs between the yellow lines. Yellow line
Yellow line
Good Reflectance Profile
A bad reflectance profile shows a scan with amplitude outside the yellow lines and having inconsistent values.
38
Online Verifier Kit Installation Guide
Page 39
Note: Make sure the media cover is on the printer. The media cover helps reduce the amount of light on the bar code label. With too much light, the bottom edge of the reflectance profile may appear jagged, as shown below. Yellow line
Yellow line
Bad Reflectance Profile
9 To get a better reflectance profile, perform the steps in “Fine Tuning Your Reflectance Profile” on page 46.
10 Click Return to clear the Reflectance Profile dialog box. 11 Click the Induce a new bar code analysis button
.
The Bar Code Analysis screen refreshes.
Online Verifier Kit Installation Guide
39
Page 40
The X (mils) parameter contains the X dimension.
12 Make sure the X dimension shown in the bottom of the Bar
Code Analysis screen is within ± 0.1 mil of 10 mils, which is the size of the calibration bar code. • If the X dimension is too large, move the OLV up (away from the bar code). • If the X dimension is too small, move the OLV down (toward the bar code).
13 Repeat Steps 8 through 12 until the Reflectance Profile and X dimension are correct. The OLV is ready to verify labels with picket fence bar codes. Your next step is to calibrate the OLV, as described in “Calibrating the OLV” on page 46.
40
Online Verifier Kit Installation Guide