Troubleshooting
Error Number 206
207
208
A
Error Message
Solution
EMCOMM WARNING - Data written to the terminal session was truncated
Problem The data transaction written is longer than the field length. The last part of the data field was dropped.
EMCOMM ERROR - A bad position was specified - cannot write data
Problem The position on the host screen is invalid. The field or region description in the script may not have the correct row and column values.
EMCOMM ERROR The terminal session is busy - timed out
Problem The EmComm timed out while waiting for the host-busy condition to clear. The timeout value in the script variables may be too short or the host may be hung. If _CRIT_EXIT is included in the script, the EmComm will exit.
Action
This error is not fatal. Verify the length of the fields.
Action Check the host screen and verify the row and column positions of the field or region. Use the Script Builder to correct the script.
Action Determine if there is a problem with the host. If you want to increase the timeout period used by the EmComm, use the GUI to edit the configuration. 209
210
211
EMCOMM ERROR The terminal presentation space is not available
Problem The EmComm application cannot find the terminal session indicated by the short session ID. The terminal session is not available.
EMCOMM ERROR The data sent to the terminal session was invalid
Problem The data written to the terminal session caused a key lock. The data is probably an invalid type.
EMCOMM ERROR The keyboard is locked and could not be cleared
Problem The EmComm has encountered a key lock condition and cannot clear it. This is a fatal error. _CRIT_EXIT will execute if it is in the script.
Action Start another session or configure the GUI with a valid screen mapping session ID.
Action Check the script and make sure that the data was entered in the correct screen. Check the source of the data to ensure that the transactions are formatted correctly.
Action The problem is either with the host or with the script. Determine the location of the problem and correct it.
A-47
Page 542
Model 200 Controller User’s Manual
Error Number 212
213
214
215
216
217
218
219
A-48
Error Message
Solution
EMCOMM ERROR The terminal screen is unformatted
Problem The EmComm cannot read from the current cursor position because the host screen is not field- formatted.
EMCOMM WARNING - A string of length 0 was encountered and was not written
Action Change the script. You cannot perform a SEND_MESSAGE or FILL_FIELD with CUR_POS specified in a non field-formatted screen. Problem The data field specified to be written was of length 0 and could not be written to the terminal session. This condition is not fatal. Action Use Script Builder to check the script, the mappings, and the source of the transaction.
EMCOMM ERROR The script has a syntax or logical error
Problem loaded.
EMCOMM ERROR The template has a syntax error
Problem
EMCOMM ERROR The call in the script could not be found syntax error
Problem
EMCOMM ERROR No script was found in the file
Problem
EMCOMM ERROR No template was found in the file
Problem
EMCOMM ERROR File error - could not open or read from the file
The script file is not written correctly and cannot be
Action Run the script checker on the script file to detect syntax errors. The template is not written correctly.
Action Review the template and make sure screen descriptions are written correctly. A call in the script file is not written correctly.
Action Review the script file and make sure the script calls are written correctly.
Action
The specified script file does not contain script. Review the script file and add script to the file. The specified template file does not contain a template.
Action Verify the template file exists or generate a new template from the menu. Problem Action
System error - the file specified could not be opened. Check that the file exists and that it is not locked.
Page 543
Troubleshooting
Error Number 220
221
222
224
Error Message
Solution
EMCOMM ERROR The screen description is not correct
Problem A screen description in the script file is not formatted correctly.
EMCOMM ERROR The region description is not correct
Problem A region description is not formatted correctly in the script file.
EMCOMM ERROR The field description is not correct
Problem file.
EMCOMM WARNING - The data field from the transaction does not exist
Problem The data field specified in either PUT_MAPPED_TRANS or PUT_TRANS_FIELD does not exist in the current data transaction. This error is not fatal. It may be an error in the mappings, the script call, or in the source of the data transaction.
Action Review the script file and make sure the screen description is correct.
Action Review the script file and make sure that the regions are described correctly.
226
227
228
A field description is not formatted correctly in the script
Action Review the script file and make sure that the fields are described correctly.
Action 225
A
Correct the error.
EMCOMM ERROR System error - the terminal session may not be started
Problem A general system error was received from the EHLLAPI. The system may not be available or the terminal session may have terminated.
EMCOMM ERROR Terminal Session in MACH CHECK state
Problem
Action
Check for errors and correct the problem. The 3270 terminal session is in MACH CHECK state.
Action Check with your network administrator to correct the problem.
EMCOMM ERROR Terminal Session system not available
Problem
EMCOMM ERROR Memory Allocation error - not enough memory
Problem
The host is not available.
Action Check with your network administrator to correct the problem. There is not enough memory to run the EmComm.
Action Check with your network administrator to correct the problem.
A-49
Page 544
Model 200 Controller User’s Manual
Error Number 229
230
233
234
235
238
240
241
A-50
Error Message
Solution
EMCOMM ERROR No match found for script key word syntax error
Problem
EMCOMM ERROR Internal processing error
Problem
EMCOMM ERROR - A IPC channel error occurred
Problem An error with the specified channel occurred. The system return code is given.
EMCOMM WARNING - The transaction sent has been truncated. It was too long.
Problem A SEND_MESSAGE call had data that was longer than the maximum data transaction size. The data was truncated and sent to the specified destination.
EMCOMM ERROR - A parameter on a script call was incorrectly formatted
Problem loaded.
A call in the script contains a syntax error.
Action Use the script checker to edit the script file to check for misspellings.
Action
Action
Action
An unknown error occurred. Contact your network administrator.
Determine the problem and correct if necessary.
Correct the problem. A parameter on a script call is incorrect and cannot be
Action Run the script checker against the script file to find the syntax error. Correct the parameter.
EMCOMM PARAMETER ERROR - Not enough command line parameters
Problem The command to start the EmComm does not have enough parameters.
Cannot open the trace file for the script file passed
Problem The EmComm is in Trace mode and could not open the trace file for the script file.
EMCOMM ERROR There was no mapping for the current screen and tran ID
Problem The current screen description is not in the list of mappings for the transaction ID of the current transaction. The script file or the configuration file may be in error.
Action Retype the command, making sure you include all the required parameters.
Action Make sure the file is not locked by another application. Only one trace can be performed on a file at one time.
Action Either use the Script Builder to add mapping for this screen and transaction or check the script file and make sure the correct screen is referenced before the PUT_MAPPED_TRANS call.
Page 545
Troubleshooting
Error Number
Error Message
Solution
276
Serio. Port is closed
Problem
A
The given serial port has been closed unexpectedly.
Action Shut down and reboot the controller. If the problem persists, contact Intermec Technical Support. 277
278
279
280
Serio. Invalid data bit value
Problem
Serio. Invalid stop bit value
Problem
Serio. Invalid parity value
Problem
Serio. Read serial port timeout.
Problem The DevComm timed out while reading the specified port. The device is not responding to the DevComm within a reasonable amount of time.
Action
Action
Action
The data bits value for the given serial port is invalid. Verify the configuration in the GUI. The stop bit value for the given serial port is invalid. Verify the configuration in the GUI. The parity value for the given serial port is invalid. Verify the configuration in the GUI.
Action Make sure the device is powered on, connected, and configured correctly. The tuning parameters may need to be adjusted for both receiving and sending data if the device is responding too slowly. Refer to the device’s user’s manual to change these values. 281
282
283
Serio. OS2, Could not set baud rate
Problem
Serio. OS2, line ctrl error
Problem
Serio. OS2, XON, XOFF error
Problem port.
Action
The baud rate could not be set for the given serial port. Verify the configuration in the GUI. Could not set the line control for the given serial port.
Action Verify that the port is a serial port, otherwise contact Intermec Technical Support. Could not set XON/XOFF protocol for the given serial
Action Verify that the port is a serial port, otherwise contact Intermec Technical Support. 284
Serio. OS2, input flush error
Problem
Could not set the input flush for the given serial port.
Action Verify that the port is a serial port, otherwise contact Intermec Technical Support.
A-51
Page 546
Model 200 Controller User’s Manual
Error Number 285
289
300
301
302
303
307
352
353
A-52
Error Message
Solution
Serio. OS2, output flush error
Problem
Serio. Could not write data to serial port
Problem
200GUI. No valid configuration file found, start DC terminated
Problem found.
200GUI. Status session could not be started, start DC continued
Problem
200GUI. .CNF file read failed, DC may not have started properly
Problem
200GUI. Error attempting to reboot controller, try manual shutdown and reboot
Problem
200GUI. Mismatch between device and destination tables, start DC terminated
Problem
200GUI. Error retrieving remaining free space
Problem
200GUI. No response to system STATUS transaction
Problem Message handler is not responding to the transaction sent by the controller to get active operational parameters.
Could not set the output flush for the given serial port.
Action Verify that the port is a serial port, otherwise contact Intermec Technical Support. An error occurred writing data to the given serial port.
Action Check that no other processes are trying to access that port. Contact Intermec Technical Support. The configuration file for the controller is bad or not
Action Verify the environment variables are set correctly. Try using another file. The status session program could not be found or started.
Action Verify the environment variables are set correctly and the DCMSTAT.EXE file is in the correct directory. An error occurred when the configuration file was read.
Action Shut down and reboot the controller. Try starting data collection again. You may have a corrupt configuration file. Restore or recreate the configuration using the GUI.
Action
An error occurred when you rebooted the controller. Shut down the controller and reboot it.
An error occurred when the configuration file was read.
Action Corrupt configuration file. You may need to restore or recreate a new configuration file using the GUI.
Action
Error checking the amount of available disk space. Check the environment variables.
Action Check if the message handler is running. You may need to stop data collection, shut down, and reboot the controller.
Page 547
Troubleshooting
Error Number
A
Error Message
Solution
200GUI. No response to system halt transaction
Problem Message handler is not responding to the transaction sent by the controller to stop data collection.
200GUI. No response to system INTER transaction
Problem Message handler is not responding to the transaction sent by the controller to establish communications.
356
200GUI. Informational: Starting 200 data collection
No problem. Informational message only.
357
200GUI. Informational: Stopping 200 data collection
No problem. Informational message only.
361
200GUI. Unable to resume interactive communications with Message handler
Problem Message handler is not responding to a transaction sent by the controller to reestablish communications.
200GUI. Attempted to create a second CON_IN IPC channel, only one allowed
Problem The controller may already be running since its IPC channel already exists. Action
Use the existing IPC channel. Do not create a new one.
Invalid # of arguments in current record read from config file.
Problem
The configuration file is not properly formatted.
Unable to add structure to config file ram tables.
Problem
354
355
364
401
402
Action Check if the message handler is running. You may need to stop data collection, shut down, and reboot the controller.
Action Check if the message handler is running. You may need to stop data collection, shut down, and reboot the controller.
Action Check if message handler is running. You may need to stop data collection, shut down, and reboot the controller.
Action Do not manually edit the configuration file; use the GUI. If you are using a file that was created by the GUI, contact Intermec Technical Support. You will be asked to send a copy of your configuration file to Intermec. The configuration file is not properly formatted.
Action Do not manually edit the configuration file; use the GUI. If you are using a file that was created by the GUI, contact Intermec Technical Support. You will be asked to send a copy of your configuration file to Intermec.
A-53
Page 548
Model 200 Controller User’s Manual
Error Number 450
451
Error Message
Solution
More data was written to device than allowed - write has failed
Problem The transaction sent to the device exceeds the maximum allowable transaction size.
Protocol error occurred
Problem The DevComm received a protocol error while sending or receiving data.
Action Verify the maximum data size that the device you are communicating with can accept and adjust the transaction accordingly.
Action Verify that the device is on and configured to match the configuration file. If your device is a 9161, try turning on the time append feature. If the problem continues, contact your network administrator or Intermec Technical Support. 452
454
Could not send data to device - device possibly not active or unavailable
Problem The DevComm could not send data to the device given, but communications are normal.
Timeout occurred during data transfer
Problem The DevComm timed out trying to send to or receive data from a device. There may be a problem with the device.
Action There may be a problem with the device such that it cannot receive data. Determine the cause of the problem and correct it. This problem most often occurs when the controller queue for a device address is full.
Action Determine the source of the problem and correct it. Contact Intermec Technical Support. Tuning parameters may need to be adjusted. 455
489
More data was received than Devcomm buffer can hold.
Problem More data was received from a device than the DevComm expected.
RC_DIRONLY. Just dir, (not file) input.
Problem DevComm: The given file name was only a directory, not a valid filename.
Action Verify that the device is configured correctly and that it is communicating.
Action 490
A-54
RC_BADDIR. Invalid drive / directory path input.
Problem Action
Provide a valid filename. DevComm: The given file path is invalid. Provide a valid file path.
Page 549
Troubleshooting
Error Number 491
492
494
495
Error Message
Solution
RC_RECORD. Invalid record number.
Problem
RC_NOMORE. No more files from dir search, etc.
Problem DevComm: The directory search is complete and no more files were found.
RC_MEM. Out of memory during allocate.
Problem
RC_INVALID_PARA M. Invalid parameter
Problem DevComm: An invalid parameter was given to the DevComm.
Action
Action
497
500
DevComm: The given record number was invalid. Correct the record number reference.
Search a different directory. DevComm: Memory allocation errors.
Action Shut down the controller and contact your network administrator.
Action 496
A
Check the parameter specification and correct the problem.
RC_NO_FILES. Cannot open another file system limits exceeded
Problem The DevComm could not open any more files. The system file handle limit has been exceeded for this DevComm.
RC_SYSERROR or RC_SYS Misc system error - check system return code
Problem
Invalid IPC handle IPC (50)
Problem DevComm: The IPC handle being used is not valid - the creator of the IPC channel may have closed it.
Action Contact your network administrator. You may have to increase the file handle limit. DevComm: Internal system error.
Action Shut down the controller and contact your network administrator.
Action Determine why the IPC channel is not available and correct the problem. The creator process may be gone. 501
Invalid IPC name - IPC (51)
Problem DevComm: The IPC name being used to open/create an IPC channel is not valid. Action Verify the IPC name being used is valid. If the IPC name is invalid use a valid name to correct the problem.
503
This IPC channel already exists - cannot recreate - IPC (53)
Problem DevComm: The IPC channel being created already exists. There is probably a DevComm running with this name. Action Shut down the controller. If the other DevComm is still running, contact Intermec Technical Support.
A-55
Page 550
Model 200 Controller User’s Manual
Error Number 504
505
Error Message
Solution
The IPC channel is full - cannot write more data - IPC (54)
Problem DevComm: The IPC transaction limit has been reached for the IPC channel specified.
The IPC channel does not exist - IPC (55)
Problem DevComm: The IPC channel requested does not exist. The creating process is probably not available.
Action Contact your network administrator. Determine why the IPC channel is overfilling and correct the problem or contact Intermec Technical Support.
Action Determine why the creating process for the specified IPC channel is not creating it. 506
Cannot create the IPC channel - IPC (56)
Problem created.
DevComm: The IPC channel specified could not be
Action Contact your network administrator. Make sure the IPC channel name is in the service file and system limits have not been exceeded. 511
BAD_FILE_ERROR
Problem
DevComm: An internal file I/O error occurred.
Action Contact your network administrator and determine source of problem. 512
Cannot create or open the file
Problem DevComm: Cannot create or open the file specified. The file may be locked. Action Determine the file status: if it is locked, unlock it to correct the problem. If the file is unlocked, contact Intermec Technical Support.
513
File access is denied.
Problem
DevComm: Access to the specified file has been denied.
Action Contact your network administrator and correct the problem. 514
Invalid file handle
Contact Intermec Technical Support to help you solve the problem.
515
The file already exists cannot recreate
Problem DevComm: The file specified cannot be recreated and will not be overwritten. Action Specify a unique filename. This operation will not overwrite or append to this filename.
A-56