Page 531

Troubleshooting

Error Number 49

50

51

52

53

56

58

A

Error Message

Solution

Invalid number of bytes in transaction read from DCM_Q IPC channel

Problem A transaction sent to the Receive channel had less than 96 or more than 1120 bytes.

Error opening a DevCom ACK IPC channel

Problem A system error occurred while opening an internal DevComm ACK channel.

Transaction received by Devcomm was in bad format

Problem The DevComm received a transaction that was not in the proper format.

The DCMXFERTMP env vbl not found cannot complete file xfer

Problem The DevComm cannot perform the FileXfer without the DCMXFERTMP environment variable.

Parameter error occured - could not initialize Devcomm

Problem A call was made to open the communication port, for example COM1, resulting in an error code.

The Devcomm name service could not translate the name given.

Problem The DevComm could not interpret either the physical or logical name given.

DEV SMA. Transaction received did not have a proper SMA format

Problem The DevComm SMA did not understand the transaction it received.

Action Do not send transactions through the controller that do not have a proper header of 96 bytes and/or more than 1K (1024 bytes) of data.

Action Check whether the DevComm is running or an invalid DevComm was running when the controller was started. Verify that a message handler is not already running. Check the specific system error for further information. Shut down and reboot the controller.

Action Verify that the application that created the transaction formatted it correctly with a 96-byte header and no more than 1024 bytes (1K) of data.

Action Make sure that the DCMXFERTMP environment variable is set prior to running the controller.

Action Verify that no other users or applications have control over the port. Check the system specific return code for more information.

Action Verify the configuration and the setup of your downline devices. If the problem continues, contact Intermec Technical Support.

Action

Try the operation again. Verify the SMA request format.

A-37

Page 532

Model 200 Controller User’s Manual

Error Number 59

60

61

62

Error Message

Solution

DEV SMA. Transaction received was neither a Request or Response msg

Problem The DevComm SMA did not understand the transaction it received.

DEV SMA. The device type specified in the transaction is not recognized

Problem The logical or physical device name given in the DevComm SMA transaction was not recognized.

DEV SMA. Invalid Data for SMA initialization

Problem

DEV SMA. Device Error

Problem A device error occurred during a DevComm SMA request and the DevComm could not complete the request.

Action

Try the operation again. Verify the SMA request format.

Action Verify the transaction and the configuration and then try the operation again. The DevComm SMA could not initialize.

Action Verify that the DevComm is not already running. If the problem persists, contact Intermec Technical Support.

Action Determine which device had the error and correct the problem. 63

DEV SMA. Invalid Request

Problem The DevComm SMA did not understand the message received. Action

64

65

67

68

DEV SMA. Invalid (request/response) transaction received

Problem The DevComm SMA did not understand the message received.

DEV SMA. Could not match the response data to an issued SMA request

Problem The DevComm SMA did not understand the message received.

DEV SMA. Unable to find Command Table for this device

Problem

DEV SMA. Command Set timeout has occurred

Problem The DevComm SMA has timed out a request from the source application specified. The request did not complete successfully.

Action

Action

Try the operation again. Verify the SMA request format.

Try the operation again. Verify the SMA request format. Internal DevComm SMA error.

Action Shut down and reboot the controller. If the error continues, contact Intermec Technical Support.

Action

A-38

Try the operation again. Verify the SMA request format.

Determine cause of failure and then try the operation again.

Page 533

Troubleshooting

Error Number 72

73

74

81

83

84

Error Message

Solution

DEV SMA. Invalid/Missing data during execution of Request/Response function

Problem The DevComm SMA did not have sufficient data to complete the request.

DEV SMA. "Soft" Protocol response received

Problem The specified error was received from the device, but no data was lost.

DEV SMA. "Hard" Protocol response received

Problem The specified error was received from the device and data may have been lost.

APPC Error. Allocate Partner Transaction Program Failed

Problem

APPC Error. Send Data to Partner Transaction Program Failed

Problem

APPC Error. Data Conversion Error

Problem Could not convert data from ASCII to EBCDIC or EBCDIC to ASCII.

Action Verify the transaction format and data and then try operation again.

Action

Action

Action

86

87

Correct the problem in the device.

Correct the problem in the device. Could not connect to partner computer. Refer to the APPC return code for more information. Could not send data to partner transaction program.

Action Verify partner transaction program verb flow and check communication between partner computers. Refer to the APPC return code for more information.

Action 85

A

APPC Error. Receive Data from Partner Transaction Program Failed

Problem

APPC Error. Receive Allocate from Partner Transaction Program Failed

Problem

APPC Error. Could not get Send Control From Partner Transaction Program

Problem

Check the ACSSVC return codes for more information. Could not receive data from partner transaction program.

Action Verify partner transaction program verb flow and check communication between partner computers. Refer to the APPC return code for more information. Allocation from partner transaction program failed.

Action Verify partner transaction program verb flow and check configuration. Refer to the APPC return code for more information. Could not switch from receive to send state.

Action Verify partner transaction program verb flow. Refer to the APPC return code for more information.

A-39

Page 534

Model 200 Controller User’s Manual

Error Number 88

89

90

91

92

93

94

98

Error Message

Solution

APPC Error. Could not Write Acknowledge transaction in DCM_ACK IPC channel

Problem Write to ACK channel failed. The controller may not be running.

APPC Error. Could not Write DCMINTER to Message handler's DCM_Q IPC channel

Problem Write to Receive channel failed. The controller may not be running.

APPC Error. Could not Allocate Memory for Temp Data Buffer

Problem Failed to allocate enough memory for proper program operation.

APPC Error. Could not Send Error to Partner Transaction Program

Problem Could not send error indicator to partner transaction program.

APPC Error. Deallocate Partner Transaction Program Failed

Problem

APPC Error. Could not Send Confirmed to Partner Transaction Program

Problem

APPC Error. TP_Ended could not complete

Problem

APPC Error. Batch File Transfer failed

Problem The batch file transfer NetComm message failed to transfer the file to the partner transaction program.

Action

Shut down and reboot the controller.

Action Examine return code and then shut down and reboot the controller. Start data collection.

Action Shut down and reboot the controller. Contact Intermec Technical Support.

Action Verify partner transaction program verb flow and check communication between partner computers. Refer to the APPC return code for more information. Could not deallocate session correctly.

Action Verify partner transaction program verb flow and check communication between partner computers. Refer to the APPC return code for more information. Could not confirm data or allocate.

Action Verify partner transaction program verb flow and check communication between partner computers. Refer to the APPC return code for more information.

Action

Could not end transaction correctly. Verify partner transaction program verb flow.

Action Check the rest of the error message and any return codes. It is an error with a BFT file extension. Check other error messages for related problems.

A-40

Page 535

Troubleshooting

Error Number 108

110

A

Error Message

Solution

Error building netcom argument list configuration argument missing/invalid

Problem Not all arguments were available for a remote application.

Error spawning receive netcom

Problem A system error occurred while creating a detached NetComm process. The message handler is continuing execution.

Action Use Advanced Setup to verify that all arguments are specified for a remote application. The configuration file may be corrupt.

Action Verify that the executable file exists in your directory and check the system error code for more information. Shut down and reboot the controller. 111

112

Error opening DCMSTOPFILE during Initialization

Problem

Error creating DCMSTOPFILE during DC stop

Problem When the controller is stopped, it saves application program information in the start/stop file DCMSTOP.DAT. A system error occurred while creating this file.

A system error occurred while opening the start/stop file.

Action Verify that DCMSTOP.DAT is a valid text file. Verify the environment variable DCMMAIN is set to a valid path and there is enough disk space available in the location to store the file. Check the specific system error code for more information.

Action Verify the environment variable DCMMAIN is set to a valid path and there is enough disk space available in the location to store the file. Check the specific system error code for more information. 113

114

Error writing to DCMSTOPFILE during DC stop

Problem A system error occurred while writing data to the start/stop file DCMSTOP.DAT.

Error closing DCMSTOPFILE during DC stop

Problem A start/stop file DCMSTOP.DAT was created and a system error occurred while closing the file handle. The file may be corrupt or missing. When the controller is rebooted, an application may not receive the last transaction sent.

Action Verify there is enough disk space available in the main directory to write to a file. Check the specific system error code for more information.

Action Make sure all data was received by the application. The application should transmit a DcmInter transaction upon startup. Check the specific system error code for more information.

A-41

Page 536

Model 200 Controller User’s Manual

Error Number 120

Error Message

Solution

Unable to write to a batch-file-transfer file

Problem The message handler process was unable to write to a file that is used to perform a batch file transfer. Action Check the return code for more specific information. Make sure that the disk partition is not full. The BFT file is read by the batch file transfer APPC NetComm after the message handler has transferred the contents of a Hot Standby file to it. The message handler returns the error condition to the requesting APPC NetComm.

121

Unable to close a batchfile-transfer file

Problem The message handler was unable to close a file that is used to perform batch file transfer. Action Check the return code for more specific information. Make sure that the disk partition is not full. The BFT file is read by the batch file transfer APPC NetComm after the message handler has transferred the contents of a Hot Standby file to it. The message handler returns the error condition to the requesting APPC NetComm.

122

Error opening batchfile-transfer file

Problem The message handler could not open/create a file that is used to perform batch file transfer. Action See previous error message. You would not expect this error to occur unless the disk is full or some other process has an existing BFT file open. If you are using the TYPE command to inspect a BFT file when a batch file transfer request comes in, the transfer will fail.

123

131

Error copying application IPC channel file to batchfile-transfer file

Problem The message handler was unable to copy the contents of a Hot Standby file to a file used for batch file transfer.

LAN. Problem reading ACK from named pipe

Problem LAN Send NetComm failed in reading the ACK from the specified named pipe.

Action See pervious error message. The most likely cause of this error is lack of disk space

Action Check the return code for specific information. Restart the remote application. 132

LAN. IPC channel Error

Problem A LAN NetComm had a problem with the specified channel. Action Check the return code for more specific information. Then, shut down and reboot the controller.

A-42

Page 537

Troubleshooting

Error Number 133

A

Error Message

Solution

LAN. Semaphore Open Error

Problem A LAN NetComm had a problem opening the specified semaphore. Action Try to restart the remote application. If the problem persists, shut down and reboot the controller. You may also have too many applications running. Check the return code for specific information.

134

LAN. Semaphore Clear Error

Problem A LAN NetComm could not clear the specified semaphore. Action Restart the remote application. If the problem persists, shut down and reboot the controller. Check the return code and other Status Monitor errors for more specific information.

135

136

137

138

LAN. Semaphore Set Error

Problem

LAN. Problem writing ACK to DCM_ACK IPC channel

Problem LANSSEND NetComm could not write the ACK message to the ACK channel.

LAN. Could not load LAN application tables.

Problem The Pipe Manager was unable to load the configuration file LAN application tables into memory.

LAN. Could not create semaphore arrays.

Problem The Pipe Manager could not create the semaphore arrays to manage the LAN semaphores.

The Pipe Manager could not set the specified semaphore.

Action Restart the remote application. If the problem persists, shut down and reboot the controller. Check the return code and other Status Monitor errors for more information.

Action Check that the controller is running. Shut down and reboot the controller. Check the return code for more specific information.

Action Check the return code for more information. You may be out of memorystop other processes and try to shut down reboot the controller. You may be out of file handles. Check your DCMMAXFH environment variable in CONFIG.SYS, increase that value, and then shut down and reboot the controller.

Action Check the return code for more information on the problem. Shut down and reboot the controller.

A-43

Page 538

Model 200 Controller User’s Manual

Error Number 139

Error Message

Solution

LAN. Could not spawn LAN netcom.

Problem The Pipe Manager could not spawn the specified LAN NetComm. Action Check the return code for specific information. Check that the DCMMAIN environment variable is correct. You may also be out of memory. Shut down and reboot the controller.

140

141

An unknown app id was found in a transaction sent to the DCM_Q IPC channel

Problem An application sent a transaction with an invalid source or destination ID in the header to the Receive channel. Data in this transaction was not delivered.

A system error occurred disabling an interrupt timeout

Problem A system error occurred while starting a thread that controls shutdown timing. The controller shutdown process may not work properly.

Action Use the GUI to verify that all applications have been configured properly and the application ID in the transaction header is that of an existing application. If the transaction is a system transaction, no action is taken.

Action If the controller shutdown did not operate correctly, stop all controller processes before continuing. Check the specific system error code for more information. This error may be tied to the _beginthread instruction and the use of dynamic link libraries for multithreaded applications. 145

Error spawning a thread

Problem A system error occurred when the message handler attempted to create a thread of execution. Action Check the specific system error code and take the appropriate action.

148

MH message. IPCWait error

Problem The message handler received an error while it was waiting for input on more than one IPC channel. Action Check the system return code and take action based on this information. Contact Intermec Technical Support.

161

A-44

LAN. LAN Server application is already active

Problem The specified remote LAN application tried to connect to the controller, but it is already active. Action Verify that the application is not running on another workstation.

Page 539

Troubleshooting

Error Number 163

Error Message

Solution

LAN. Creation of the named pipe failed.

Problem pipe. Action

164

LAN. Named pipe failed to connect.

A

The LAN NetComm could not create the specified named Check the return code for specific information.

Problem The LAN NetComm received a failure when trying to connect the specified named pipe. Action Check the return code for specific information. Restart the remote application.

165

LAN. Named pipe write failure

Problem The LAN NetComm failed when writing to the specified named pipe. Action Check the return code for specific information. Restart the remote application.

166

LAN. Named pipe read failure

Problem The LAN NetComm failed when reading from the specified named pipe. Action Check the return code for specific information. Restart the remote application.

167

LAN. Failed to set the named pipe handle state

Problem The LAN NetComm could not set the state of the named pipe handle. The remote application may have closed the named pipe. Action Check the return code for more specific information. Try restarting the remote application.

168

169

170

LAN. Named pipe close failure

Problem

LAN. LAN Server application is not currently configured

Problem The remote LAN application specified is not configured in the configuration file currently in use.

LAN. Failed to spawn thread for pipemgr

Problem The controller may be trying to spawn more threads than is allowed by the system.

The LAN NetComm failed to close the named pipe.

Action Check the return code for specific information. This condition is nonfatal as the application is shutting down.

Action Check that the application is spelled correctly in the GUI. Check that the proper file is being used and is listed in the Status Monitor.

Action The THREADS statement in the CONFIG.SYS file governs the number of concurrent threads that the controller will allow.

A-45

Page 540

Model 200 Controller User’s Manual

Error Number 171

200

201

202

203

204

Error Message

Solution

APPC. Invalid transaction size received for batch file transfer

Problem The batch file transfer NetComm received a message that was of invalid size.

EMCOMM ERROR Screen description could not be found

Problem The host screen description is not defined in the template for this screen mapping application.

EMCOMM ERROR Field description could not be found

Problem The host screen field description could not be found in the current screen description for this portion of the script.

EMCOMM ERROR Region description could not be found

Problem The region label could not be found in the screen description.

EMCOMM ERROR Field or region description could not be found EMCOMM ERROR The tran ID could not be found in the mappings

Action

Check that the Hot Standby files have not been corrupted.

Action Check the template and script file and make sure a screen description exists for the specified screen label.

Action Check the template or script file and make sure the current screen’s fields are correctly defined.

Action Check the template or script file and make sure the screen region is correctly defined. Problem The host screen field or region label could not be found in the screen description. Action Check the template or script file and make sure the region or field is correctly defined. Problem The transaction ID for the current transaction could not be found in the list of transaction IDs for this application name. An application may have erroneously sent a transaction to this application with a bad transaction ID. Action Check the source of the transaction and correct the problem or use the GUI to add this transaction ID to the configuration file.

205

EMCOMM ERROR No mapping exists for this tran ID.

Problem The transaction ID for the current transaction does not have any screen mappings configured in the GUI. The script call PUT_MAPPED_TRANS was called with the transaction ID, but no mappings were found. Action Either edit the script so that the PUT_MAPPED_TRANS is not called with this transaction ID, or use the Script Builder to specify a mapping for the transaction.

A-46