The text of a manual · part 30 of 70
Model 200 Controller System Manual, pages 291 to 300
Pages 291 to 300 of 695
The original document is the PDF (3.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 0200
Page 291
Using Terminal Emulation
8
Configuring for UDP Plus Communications You need to configure each JANUS 2.4 GHz RF device for UDP Plus communications. Run the JANUS 2.4 GHz Installation Utility to configure each device and install the network software. For help, see the JANUS 2.4 GHz Installation Utility User’s Manual. Note: If the access points are using a security ID, you must set the same security ID on the JANUS devices.
Downloading the JANUS TE Application To run 5250 or 3270 TE, you do not need to load any files on your JANUS device. Your JANUS device was shipped from Intermec with the TE files already loaded. However, if you lose these TE files, or change the JANUS TE application, you may want to download the .CFG file, the .MAP file, and the application. To run VT or ANSI TE, you must download the TE.CFG file and the TE application from the controller to each JANUS device. When you download the JANUS TE application, the files must be on the E drive. On the controller, these files are in the \USERDATA\TERMAPPS\TE\ADD_FILE directory:
TE.CFG This file contains the configuration information that each JANUS device needs to run VT or ANSI TE. You define the configuration on the JANUS device using the Terminal, Communications, and Viewport screens in the TE Configuration menu. TE5250.CFG This file contains the configuration information that each JANUS device needs to run 5250 TE. TE3270.CFG This file contains the configuration information that each JANUS device needs to run 3270 TE. JAN5250.MAP This key mapping file is used with 5250 terminal emulation. This file is read only. JAN3270.MAP This key mapping file is used with 3270 terminal emulation. This file is read only.
8-31
Page 292
Model 200 Controller User’s Manual
On the controller, these files are in the \USERDATA\TERMAPPS\TE\JANUS900 directory:
TNVT900.EXE This executable file runs VT/ANSI TE. You can only use this file if your JANUS 900 MHz RF device uses firmware v3.1 or higher. J95250.EXE This executable file runs 5250 TE. You can only use this file if your JANUS 900 MHz RF device uses firmware v3.1 or higher. J93270.EXE This executable file runs 3270 TE. You can only use this file if your JANUS 900 MHz RF device uses firmware v3.1 or higher. On the controller, these files are in the \USERDATA\TERMAPPS\TE\JANUSUDP directory:
UDPPVT.EXE This executable file runs VT/ANSI TE. You can only use this file if your JANUS 2.4 GHz RF device uses UDP Plus and firmware v4.1 or higher. To run 5250 or 3270 TE, you should not need to download the .CFG file and the JANUS TE application from the server. UDPP5250.EXE This executable file runs 5250 TE. You can only use this file if your JANUS 2.4 GHz RF device uses UDP Plus and firmware v4.1 or higher. UDPP3270.EXE This executable file runs 3270 TE. You can only use this file if your JANUS 2.4 GHz RF device uses UDP Plus and firmware v4.1 or higher. Depending on the type of communications your JANUS devices are using and which firmware version is loaded, you can download the application to your JANUS devices using one of these methods: • If your JANUS device in a 900 MHz RF network has firmware v3.01 or later, use the download server feature. Note: Your JANUS devices must have FTA.EXE and FTA.INI loaded on drive C. Copy these files from Application companion disk 3. For help, see your JANUS user’s manual. Note: Your JANUS devices must be running a BFT-ready PSK application. • If your JANUS 2.4 GHz RF device is using UDP Plus, use the download server feature or FTP. To use FTP, you must have an FTP client loaded on your JANUS device.
8-32
Page 293
Using Terminal Emulation
8
Using the Download Server to Download the JANUS TE Application 1. If you want to send the TE files to more than one JANUS device, define a group in the download server. For help, see “Adding a Group in the Download Server” in Appendix B. 2. From the main menu sidebar buttons, choose System Maintenance. The System Maintenance dialog box appears. 3. In the System Maintenance list box, select Configure Download Server and then choose Start. The Terminal Download Configuration dialog box appears. 4. In the Terminals and Groups list box, select the terminal or group that needs the TE files. 5. Choose Edit. The Configure Device Initialization Download dialog box appears.
8-33
Page 294
Model 200 Controller User’s Manual
6. In the Initialization Data box, choose File. 7. In the field, type the path and filename of the .CFG file that contains the configuration information that each JANUS device needs to run TE. 8. Check the Binary file check box. 9. Choose Overwrite if you want to overwrite any existing files with the same name on the JANUS devices. Do not choose Append. 10. Choose Add. The file appears in the Files and Data list box with a B in the leftmost column. 11. Repeat Steps 7 through 10 to add the path and filename of the .EXE file that runs the JANUS TE application. 12. (5250/3270 only) Repeat Steps 7 through 10 to add the path and filename of the .MAP file for the type of JANUS TE application you are using. 13. Choose OK to save your changes and return to the Terminal Download Configuration dialog box. 14. In the Terminals and Groups list box, choose the terminal or group you configured. 15. Choose Download. The TE files are downloaded to the terminal or group. 16. Choose Close to return to the System Maintenance dialog box. 17. Choose Close to return to the main menu.
Using FTP to Load the JANUS TE Application Note: FTP commands are case-sensitive. You must type all commands in lowercase.
%3/M
@
1. Make sure that the JANUS device is at a writable DOS prompt. Type IPaddress and press where IPaddress is the IP address of the controller.
- . - 8 , . 4 2 and press 3. Type " # M path and press @ @
2. In the login name field, type .
where path is the location of the JANUS TE application on the controller.
8-34
Page 295
Using Terminal Emulation
8
! ( - and press @ . 5. Type & $ 3 M filename.cfg and press @ . 4. Type where filename.CFG is the name of the file that contains the configuration information that each JANUS device needs to run TE. 6. Type
& $ 3 M filename.exe and press @ .
where filename.EXE is the name of the executable file of the JANUS TE application.
04(3
@
7. When the terminal template application has finished loading on the JANUS device, type and press .
Accessing the TE Configuration Menu JANUS terminal emulation is controlled by a configuration file. You can edit the terminal emulation parameters using a menu-driven interface. • When you are running VT or ANSI TE, you can access the TE Configuration menu at any time by pressing .
>I • When you are running 5250 or 3270 TE, you can access the TE Configuration menu at any time by pressing < 7. Or you can scan: Exit
*%EXIT*
C E
B D
Use the and keys to move between fields. Use the and keys to change the preset values for the fields. For help using the TE Configuration menu, see your JANUS 900 MHz Terminal Emulation Quick Reference Guide or the JANUS 2.4 GHz Terminal Emulation Quick Reference Guide. You can set a password for the TE Configuration menu to prevent unauthorized users from accessing this menu. For help, see “Setting Security for the TE Configuration Menu” later in this chapter. Using this menu, you can edit the parameters in the Terminal screen, Communications screen, and the Viewport screen. When you exit the TE menu, the TE session is restored.
8-35
Page 296
Model 200 Controller User’s Manual
Exiting the TE Configuration Menu 1. From the TE Configuration menu, choose Exit Config and press Save New Configuration screen appears.
The
2. Choose Yes and press if you want to save the TE configuration. Your terminal saves the configuration options to flash memory and the sign-on screen appears.
Choose No and press if you do not want to save the TE configuration. You exit the TE Configuration menu and the sign-on screen appears.
Choose Cancel and press to return to the TE Configuration menu. You can continue making changes to the TE configuration.
Starting TE When you start a TE session on your JANUS device, the device establishes a connection with the controller and displays the host login screen. To start a TE session on the JANUS device 1. Make sure the host and the application support the selected terminal type. 2. Make sure that you have started data collection on the controller.
L to resume the JANUS device. 4. (5250/3270 only) At the DOS prompt on your JANUS device, type 16321. 3. Press
5. On the JANUS device type:
) - - to start a 5250 TE session. ) to start a 3270 TE session. 3 - 5 3 to start a VT/ANSI TE session.
6. Wait a few seconds while the display clears and the TE program starts. 7. When the display on your JANUS device shows the login screen, log into the host. If the auto-login script file is in the current directory, the JANUS device keeps the login information in memory.
8-36
Page 297
Using Terminal Emulation
8
You are ready to use terminal emulation on your JANUS device. Tip: To make it easier for users to start a TE session, you may want to create a batch file that performs this procedure.
Ending TE To end a TE session on your JANUS device, perform one of these steps: To logoff from the host and use the auto-login feature VT/ANSI At the TE prompt, type EXIT. You return to a DOS prompt. If the auto-login script file is in the current directory, you return to the first screen after the login screen. Or, press
> K to go immediately to a DOS prompt.
5250/3270 Enter the appropriate command to logoff from the host screen. You return to the login screen. If the auto-login script file is in the current directory, you return to the first screen after the login screen. To return to the DOS prompt, follow the next procedure to exit TE. To exit TE and delete the auto-login information 1. Access the TE Configuration menu.
>I. 5250 or 3270 On the JANUS device, press < 7 . 2. Select the Exit TE command and press @ . The next time you start a TE VT/ANSI
On the JANUS device, press session on the JANUS device, you will need to log in again.
This method prevents another user from using your login.
About Running TE When you start the TE program on the JANUS device, it attempts to establish communications with a host session by sending a request to the Model 200 Controller terminal session manager. • If a terminal session is started, then the terminal session becomes active and the JANUS device can communicate with the host.
8-37
Page 298
Model 200 Controller User’s Manual
• If a terminal session is started and then the connection is broken, the TE program on the JANUS device exits and you must restart it. • If the request for a terminal session is rejected, a message is sent back to the JANUS device. For help, see your JANUS 900 MHz Terminal Emulation Quick Reference Guide or the JANUS 2.4 GHz Terminal Emulation Quick Reference Guide.
About the Auto-Login Feature When the terminal session is started, the terminal screen displays the host login prompt. If you are using the auto-login feature, then once you log into a host, the terminal runs the auto-login script file and saves your login information in memory. If you lose a connection to the host, you will automatically be logged into the subsequent TE session. However, if you use a hot key sequence to end the TE session or if you need to reboot the device, you need to login again. For more help on creating the auto-login script file, see the JANUS 900 MHz Terminal Emulation Quick Reference Guide or the JANUS 2.4 GHz Terminal Emulation Quick Reference Guide. After you create your auto-login script file (AUTOLOG.SCR), you need to download it to your JANUS device. This file must reside in the same directory as the TE application. On the controller, a sample AUTOLOG.SCR is provided in the \USERDATA\TERMAPPS\TE\ADD_FILE directory. To use the auto-login feature
>J. • For 5250 or 3270, press < K . • For VT/ANSI, press
• Or, you can scan: Auto-Login Restart
*%ALRS*
8-38
Page 299
Using Terminal Emulation
8
Displaying International Characters You can configure your JANUS devices to display single-byte international characters. This feature lets the device display screen data using various character sets while running terminal emulation. This feature maps SBCS code pages for various Latin-based languages to SBCS code page 850, a multilingual code page for Latin-based languages. On the Model 200 Controller, you can find the .MAP files in the \USERDATA\TERMAPPS\TE\INTERNAT directory. To use international character sets 1. On the Model 200 Controller, rename the desired code page table .MAP file to DISPTBLS.MAP. Refer to the table below. 2. Download the new DISPTBLS.MAP file to your device. For help, see “Using the Controller to Transfer Files” in Appendix B. 3. Modify the AUTOEXEC.BAT and CONFIG.SYS files on your device to display the international characters. For help, see the JANUS 900 MHz Terminal Emulation Quick Reference Guide or the JANUS 2.4 GHz Terminal Emulation Quick Reference Guide. Country
Code Page Table
Other Countries
U.S. English
037-850.MAP
Canada
France
297-850.MAP
Germany
273-850.MAP
Italy
280-850.MAP
Norway
277-850.MAP
Denmark
Portugal
500-850.MAP
Belgium, Brazil, Switzerland
Spain
284-850.MAP
Sweden
278-850.MAP
Finland
Note: To create a custom translation table for non-IBM hosts running VT/ANSI TE, copy ISO1-850.MAP for UNIX hosts or DEC-850.MAP for DEC/VAX hosts and rename the file to DISPTBLS.MAP.
8-39
Page 300
Model 200 Controller User’s Manual
Configuring Your TRAKKER Antares Terminals With the Model 200 Controller, you can run VT or ANSI terminal emulation (TE) between your TRAKKER Antares terminals and a TCP/IP host. You can run 5250 or 3270 terminal emulation between your terminals and an IBM SNA host. You can also run TN5250 or TN3270 terminal emulation between your terminals and an IBM host that supports Telnet.
Configuring for Communications Before you can run terminal emulation, you need to configure each terminal to communicate in the 2.4 GHz RF network or the Ethernet network. Press to access the TRAKKER Antares 2400 Menu System. On the T248X, press to access the TRAKKER Antares 2400 Menu System. For help, see your TRAKKER Antares terminal user’s manual. You need to set these parameters on each terminal:
S3,
• Time and date • Network activate • Network port (must match the Model 200 Controller) • Controller IP address (must match the Model 200 Controller) • Terminal IP address • RF domain (for the access point) • RF security identification (for the access point) The terminal also needs to know where to send transactions. Choose one of these options: • Explicitly link the terminals to a host. For help, see “Configuring the Controller” earlier in this chapter. • Identify a host name on each terminal. For help, see your TRAKKER Antares terminal user’s manual.
8-40