Page 281
Using Terminal Emulation
8
Performing a Double Pass-Through on the IBM AS/400 Host Note: To use this feature with 5250 terminal emulation, your AS/400 must be version 2.3 or higher. When using 5250 terminal emulation, you may want to perform a double pass-through to log into a remote IBM AS/400 host. A double pass-through lets you log into one AS/400 and then access another AS/400 through the first one. To perform a double pass-through 1. On your terminal, log into the AS/400 that you want to use for the passthrough. 2. At the command line on your terminal, type: strpasthr hostname where hostname is the name of the AS/400 you want to access. This host does not need to be defined on the controller. You are connected to the remote AS/400 through the original AS/400 you logged into. To exit the remote IBM AS/400 host • At the command line on your terminal, type: endpasthr You are connected to the original AS/400.
8-21
Page 282
Model 200 Controller User’s Manual
Setting Up 3270 SNA Terminal Emulation When you set up your data collection network to run 3270 SNA TE, you must configure the host, the controller, and data collection devices. Note: To set up TN3270 terminal emulation, see “Setting Up Telnet Terminal Emulation” earlier in this chapter.
Configuring the Host For 3270 TE, your network administrator must set up the host to see the Model 200 Controller as an IBM model 3174 terminal controller. Your network administrator also needs to provide all the NAUs (host field: LOCADDR) that are set up on the host for the devices to use. SDLC connections can be direct or through a modem. If you are connecting to the host using SDLC, you also need to know these parameters: • the non-switched or switched SDLC station address (host field: ADDR) • the node ID (host field: IDBLK+IDNUM)
Configuring the Controller To run 3270 TE between JANUS devices and TRAKKER Antares terminals and the host, you must identify all the IBM SNA hosts. You also need to configure the controller SNA node. Then, you can link or unlink terminals to specific hosts. If an explicit link is set up between a terminal and a host, it means that the terminal can only start TE sessions with that host. If no explicit link is set up, the terminal can start a TE session with any host in the Host Name list. It will start a TE session with the host that is configured on the terminal. Before you proceed, make sure you have already performed these tasks: • Installed the Model 200 Controller. • Installed and configured the connection points and downline devices. • Configured the network adapter cards.
8-22
Page 283
Using Terminal Emulation
Field
Description
Value
Default
Host Name
This list box contains the logical names of the 3270 SNA hosts.
Predefined
None
Host Name Linked Terminal - NAU
The terminals that are linked to a specific host.
None
None
Available Terminals
The list of all the terminals that are available to add to the Host Name Linked Terminal - NAU list box.
Predefined
None
8
8-23
Page 284
Model 200 Controller User’s Manual
To set up 3270 terminal emulation 1. From the main menu, choose Terminal Emulation. 2. Choose 3270 SNA Terminal Emulation. The 3270 Terminal Emulation Configuration dialog box appears. 3. Make sure that you have added all your hosts. The Host Name list box contains all the existing host names. For help, see “Adding an IBM SNA Host” later in this section. Note: You cannot delete a host if it is linked to a device or a terminal session. 4. Make sure that you configure the controller SNA node. For help, see “Configuring the Controller SNA Node” earlier in this chapter. 5. Decide how to set up NAUs for the terminals: • Fill the NAU pool for each of the hosts, but do not explicitly link any terminals to hosts. Terminals can dynamically connect with any host that has available NAUs. Terminals must be configured with a host name. • Do not fill the NAU pool for any of the hosts. When you explicitly link terminals to hosts, the controller automatically generates NAUs starting at 002. • Fill the NAU pool for each of the hosts and explicitly link some terminals with hosts and NAUs. You cannot link the NAUs in the pool. For help, see “Filling the NAU Pool” later in this chapter. 6. (Optional) Create any explicit links between hosts, terminals, and NAUs. a. In the Host Name list box, select the host that you want to link to a terminal. b. In the Available Terminals list box, select the terminal that you want to link to the host. c. Choose Link. The host name, logical name of the terminal, and NAU appear in the Host Name - Linked Terminal - NAU list box. To change the NAU that the controller assigns to the terminal, see “Editing a Link” later in this chapter.
8-24
Page 285
Using Terminal Emulation
8
7. (Optional) Unlink any explicit links between hosts, terminals, and NAUs. a. In the Host Name - Linked Terminal - NAU list box, select the host, the logical name of the terminal, and NAU that you want to unlink. b. Choose Unlink. The host name, terminal, and NAU are removed from the Host Name - Linked Terminal - NAU list box. 8. Choose Close to close the dialog box and return to the main menu.
Adding an IBM SNA Host You need to identify any hosts you want the Model 200 Controller to communicate with for your terminal sessions. When you add a host, you set up a link to a specific host and this information is available throughout the system. Once you create a host connection, you may use it for any SNA configurations. Only one host connection is allowed for SDLC network adapter cards. The controller maintains separate lists for 3270 hosts and 5250 hosts. If you create a host when defining a 5250 terminal session, you cannot use this host when defining a 3270 terminal session. Local PU field Use this field when you want your terminals to be able to communicate with different hosts through one upline adapter card. For each host configuration for the upline adapter card, you assign a unique host name and a unique local PU. Because you are using the same adapter card, all other fields in this dialog box are the same. To connect to different hosts, change the host name on your terminal.
8-25
Page 286
Model 200 Controller User’s Manual
Field
Description
Value
Default
Host name
A unique name that identifies this SNA host. You can use this internal name to make the host LU name more meaningful.
1 to 8 alphanumeric characters
None
Adapter card
The network adapter card you are using to connect to the host.
Ethernet, Token Ring, SDLC
Ethernet 1
Local PU (Ethernet and token ring only)
A unique PU name for the host that allows the terminals to communicate with more than one host using the same upline adapter card.
8 uppercase alphanumeric or special characters
SNA node name + 2-digit suffix, starting with 01
Address (Ethernet or token ring only)
The LAN adapter address of the host.
Token ring MAC address format
None
Node ID
Specifies the last eight characters in the host XID that are used for establishing a connection with the controller.
8 hexadecimal characters
05D00000
8-26
First character must be an alpha character.
Page 287
Using Terminal Emulation
8
To add an IBM 3270 SNA host 1. From the 3270 Terminal Emulation Configuration dialog box, choose Add. The Host Connection Configuration dialog box appears. 2. In the Host name field, enter a meaningful and unique name for the host. 3. In the Adapter card field, click the down arrow on the right side of the field. A list that contains the available adapter cards appears. Select the adapter card you are using to connect to the host. 4. (Ethernet or token ring only) In the Address field, enter the LAN adapter address of the remote host. For help, see “Converting Ethernet Addresses to Token Ring MAC Format” in Appendix B. 5. (Ethernet or token ring only) In the Local PU field, enter a unique PU (physical unit) name for the host. The default name is the local SNA node name plus a 2-digit suffix. 6. In the Node ID field, enter the last eight characters in the XID that establish a host connection. The Node ID is the same as the XID. Note: When establishing a connection, the host or controller with the higher Node ID number is the primary workstation. 7. Choose OK to save your changes. You return to the 3270 Terminal Emulation Configuration dialog box.
8-27
Page 288
Model 200 Controller User’s Manual
Filling the NAU Pool 1. From the 3270 Terminal Emulation Configuration dialog box, choose NAU Pool. The 3270 NAU Pool dialog box appears.
2. Add all the NAUs to the NAU pool. a. In the New NAU field, type in the NAU. b. Choose Add. The NAU is added to the Unlinked NAUs pool. 3. Remove any NAUs that you do not want to use. a. In the Unlinked NAUs pool, select the NAU to remove. b. Choose Delete. The NAU is removed from the pool. 4. Choose Close to return to the 3270 Terminal Emulation Configuration dialog box.
8-28
Page 289
Using Terminal Emulation
8
Editing a Link 1. From the 3270 Terminal Emulation Configuration dialog box in the Host Name - Linked Terminal -NAU list box, select the NAU that you want to change. 2. Choose Edit Link. The Edit NAU Address dialog box appears.
3. In the Current NAU field, enter a new NAU for the terminal. 4. Choose OK to return to the 3270 Terminal Emulation Configuration dialog box.
Saving and Activating Your Run-Time Configuration If you are done configuring the controller, save and activate your run-time configuration. When the activate is complete, a message box appears if you need to reboot the controller. To save and activate your run-time configuration 1. From the main menu sidebar buttons, choose Save and Activate. The Activate Configuration message box appears. 2. Choose Activate. The controller saves your run-time configuration to disk and it becomes your active configuration. If you are ready to start data collection, from the main menu sidebar buttons, choose Start Data Collection.
8-29
Page 290
Model 200 Controller User’s Manual
Configuring Your JANUS Devices With the Model 200 Controller and your JANUS 900 MHz RF devices or your JANUS 2.4 GHz RF devices using UDP Plus, you can run: •
VT or ANSI terminal emulation (TE) to a TCP/IP host.
•
5250 or 3270 TE to an IBM SNA host.
•
TN5250 or TN3270 TE to an IBM host that supports Telnet.
Configuring for 900 MHz RF Communications You need to configure each JANUS 900 MHz RF device for 900 MHz RF communications. Run the Interactive Configuration application (IC.EXE) on each device to set the parameters for the environment it will be used in. For help using IC.EXE, refer to your JANUS user’s manual. To configure your JANUS 900 MHz RF device 1. In the Com menu, choose RF and press
@.
2. Choose Activate. 3. In the RF Protocol field, select Enabled. 4. Choose Primary Cfg. 5. In the Device Address field, enter the address of the JANUS device. This address must match an address that is enabled on the Model 200 Controller. 6. Configure the Channel Select and the Network ID. 7. In the File menu, choose Exit. 8. Choose Yes to save your configuration.
8-30