Fast Setup Quick Reference Guide

Field

Description

Value

Default

Serial port

The serial port on the controller that connects to the external Intermec controller.

COM1, COM2

COM1

RFNC address

The radio frequency network address of the RF controller card. Devices use this address to communicate with the BRUs attached to this card.

0 to 63

0

The network ID of the RF controller card. Devices use this ID during a channel search to locate the RF controller card’s RFNC address.

1 to 254

RF channel

The channel that the RF controller card will use.

0 to 6

0

Multi-Drop and RF

The number of device addresses to be enabled for the RF controller card, UDP Plus, or an external Intermec controller.

Varies

8

Point-to-Point (9161 only)

The number of device addresses to be enabled on the 9161 controller.

Varies

9161-01 is 8 9161-02 is 0

Network ID

If 0 is being used, the next available number is the default. 1 If 1 is being used, the next available value is used.

Configuring an RF Card for Your Network 1. In the Available Connections list box, select the RF card you want to configure. 2. In the RF Card Parameters box, enter the RFNC address, network ID, and RF channel. 3. In the Multi-Drop and RF field, enter the number of device addresses you want to enable on the controller. 4. Choose Configure to save your changes. The RF card appears in the Configured Connections list box. 5. Choose Close to close the dialog box and return to the main menu.

18

Page 22

Fast Setup Quick Reference Guide

Configuring a UDP Plus Network 1. In the Available Connections list box, select UDP Plus. 2. Choose Configure to save your changes. The Setup for UDP Plus Terminals dialog box appears.

To set up the UDP Plus devices using a DNS server 1. In the Number of terminals to enable field, enter the number of logical names that you want the controller to generate. 2. Check the Use DNS check box. Note: Before you can use DNS, you must use Advanced Setup to configure a DNS server in the DNS Configuration dialog box. 3. In the Base logical name field, enter the base name that the controller uses to create a unique logical name for each terminal. The controller appends a sequential 3-digit number to this name for each terminal.

19

Page 23

Fast Setup Quick Reference Guide

4. In the Domain field, enter the name of the domain that all of the terminals are in. Note: If you enable the Use DNS check box and you do not enter a domain, the server searches the domains that are listed in the DNS Configuration dialog box. 5. Choose OK. The controller generates the logical names and you return to the Fast Setup for Downline Network dialog box. 6. Choose Close to close the dialog box and return to the main menu.

To set up the UDP Plus devices using the controller to generate IP addresses 1. In the Number of terminals to enable field, enter the number of IP addresses that you want the controller to generate. 2. Clear the Use DNS check box. 3. In the Base logical name field, enter the base name that the controller uses to create a unique logical name for each terminal. The controller appends a sequential 3-digit number to this name for each terminal. 4. In the Starting IP address field, enter the starting IP address. The IP address must be a valid IP v4 address. 5. In the Subnet mask field, enter the subnet mask that the server uses to validate the IP addresses. The controller verifies that they do not cross a subnet boundary. 6. Choose OK. The controller assigns valid sequential logical names and IP addresses to the terminals starting with the starting IP address and then you return to the Fast Setup for Downline Network dialog box. 7. Choose Close to close the dialog box and return to the main menu.

20

Page 24

Fast Setup Quick Reference Guide

Configuring an Intermec Controller for Your Network 1. In the Available Connections list box, select the external Intermec controller you want to configure. 2. In the Serial port field, click the down arrow on the right side of the field. A list that contains the available serial ports appears. Choose the serial port on the Model 200 Controller that is connected to the external controller. 3. In the End Devices Enabled box, enter the number of Multi-Drop or Point-to-Point device addresses you want to enable on the controller. Protocol

Controller

End Devices Enabled

Multi-Drop and RF

9180 v1.x, 9180 v2.x

0 through 128

9154

0 through 32

9161-02

0 through 128

9161-01

0 through 16

9161-02

0 through 12

Point-to-Point

4. Choose Configure to save your changes. The controller appears in the Configured Connections list box. 5. Choose Close to return to the main menu.

Verify Your Data Collection Environment Once you configure the Fast Setup for Downline Network dialog box, you may want to verify that you have a connection between the Model 200 controller and a device. When sending a transaction to a device (destination), make sure that your device is ready to accept the transaction. If your device is not ready, the transaction is written to the Hot Standby file. If the device does not know how to interact with the Hot Standby file, subsequent transactions will also be written to the Hot Standby file. In this case, clear the Hot Standby file before sending another transaction to the device. For help, see “Clearing the Hot Standby Files” in Appendix A in the Model 200 Controller User’s Manual.

21

Page 25

Fast Setup Quick Reference Guide

Before you verify your data collection environment, make sure you activate your current configuration and start data collection. To get to the Send Transaction dialog box, from the main menu sidebar buttons choose System Maintenance. The System Maintenance dialog box appears. Select Send Transactions and then choose Start. The Send Transaction dialog box appears.

Field

Description

Value

Default

Source ID (Optional)

This field can contain the destination name that you want to use as the source of the transaction.

1 to 16 alphanumeric characters

None

Destination ID (Optional)

This field can contain the logical name of the device.

1 to 16 alphanumeric characters

None

Transaction ID (Optional)

This field can contain the transaction ID of the transaction that you want to send to all devices that accept it.

1 to 20 alphanumeric characters

None

Data or System

This field identifies the transaction as either a data or a system transaction.

D, S

D

Data (Optional)

This field contains any data that you want to send with the transaction ID.

1 to 1024 characters

None

22

Page 26

Fast Setup Quick Reference Guide

To verify your data collection environment 1. (Optional) In the Source ID field, enter a destination name that you want to use as the source of the transaction. 2. If you want to send the transaction to one device, in the Destination ID field enter the logical name of the device that you are using to verify the connection. Note: If you are using the Send Transactions feature to verify your host connection, enter the name of the host application. Or, if you want to send the transaction to all the devices that are configured to accept it, in the Transaction ID field enter the unique name of the transaction. 3. In the Data or System field, enter D or S. This field defines the transaction as either a data or a system transaction. 4. (Optional) In the Data field, enter any data you want to send with the transaction ID. 5. Choose Send to send the transaction to the device. 6. Choose Close to close the dialog box and return to the System Maintenance dialog box. 7. Choose Close to return to the main menu.

23

Page 27

Fast Setup Quick Reference Guide

Step 6 - Set Up the Host Communications Environment To set up the host communications environment, you need to configure any network adapter cards in your Model 200 Controller. The network adapter cards that your controller may contain are: • Ethernet • token ring • coaxial • twinaxial • SDLC To configure the network adapter cards 1. From the main menu, choose Fast Setup. 2. Choose Local Network Adapter. Note: Fast Setup grays out the buttons for any network adapter cards that are not installed in your controller. 3. Choose the button for the network adapter card you want to configure and follow the appropriate instructions in this section.

24

Page 28

Fast Setup Quick Reference Guide

Ethernet Adapter Card If you are using Ethernet adapter cards in the controller in a TCP/IP network, use Fast Setup to enter the parameters required for the TCP/IP protocol for each of the cards. Use the information from the Network Adapter Cards Worksheet to help you fill in the fields in this dialog box. Note: The default setting for the Ethernet adapter card is 10BaseT. Contact your local Intermec representative if you are using 10Base2 or 10Base5. Note: If your controller contains two cards (two Ethernet cards or one Ethernet and one token ring card) that communicate using TCP/IP, each card must use a different subnet. If you are not using the Ethernet adapter cards in a TCP/IP network, you do not need to configure them.

25

Page 29

Fast Setup Quick Reference Guide

Field

Description

Value

Default

Ethernet TCP/IP card

The Ethernet card that you are configuring.

Ethernet 1 Ethernet 2

Ethernet 1

Use DHCP

This check box enables this network adapter card to be administered by a DHCP server.

Check, Clear

Clear

Local host name (Optional)

A meaningful name that identifies the controller to the network.

1 to 12 alphanumeric characters

ACCNET

Local IP address

The IP address that identifies the Ethernet card. The IP address must be a valid IP v4 address.

xxx.xxx.xxx.xxx where xxx is a value between 0 and 255

None

Subnet mask

The mask that is used in the IP protocol layer to separate the subnet address from the local IP address.

xxx.xxx.xxx.xxx where xxx is a value between 0 and 255

Calculated based on IP address

To configure the Ethernet card 1. From the main menu, choose Fast Setup. 2. Choose Local Network Adapters. 3. Choose Ethernet. The Ethernet TCP/IP Adapter Configuration dialog box appears. 4. In the Ethernet TCP/IP Card field, click the down arrow on the right side of the field. A list of Ethernet cards that are installed in your controller appears. Select the card you want to configure. Note: If you have two or more 10 Mbps Ethernet cards, Ethernet 1 is the Ethernet card that is in the slot the furthest left if you are facing the controller front panel. If you have a 100 Mbps Ethernet card, it is Ethernet 1. 5. To enable DHCP, check the Use DHCP check box. Go to Step 9. Or, to disable DHCP, clear the Use DHCP check box. Go to Step 6.

26

Page 30

Fast Setup Quick Reference Guide

6. (Optional) In the Local host name field, enter a meaningful TCP/IP host name for the controller. 7. In the Local IP address field, enter the address that identifies this Ethernet card in the controller (host) to the network. This IP address must be a valid IP v4 address. 8. In the Subnet mask field, enter the mask used in the IP protocol layer to separate the subnet address from the local IP address. 9. Choose OK to save your changes and return to main menu.

Token Ring Adapter Card If you are configuring the token ring card in the controller for a TCP/IP network, you need to use Advanced Setup. For help, see Chapter 5, “Connecting to an Ethernet/Token Ring Network” in the Model 200 Controller User’s Manual. If you are not using your token ring card in a TCP/IP network, you do not need to set any parameters for a token ring adapter connection. All parameters are set to default values. If you choose Token Ring, a message box appears. Choose OK to close the message box and return to the main menu.

Coaxial Adapter Card You do not need to set any parameters for a coaxial adapter connection. All parameters are set to default values. If you choose Coaxial, a message box appears. Choose OK to close the message box and return to the main menu.

27