Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 70

Model 200 Controller System Manual, pages 11 to 20

Pages 11 to 20 of 695

The original document is the PDF (3.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 0200

Page 11

Fast Setup Quick Reference Guide

Step 1 - Complete the Worksheets Before you use Fast Setup, complete the relevant worksheets in Appendix E in the Model 200 Controller User’s Manual. You will need to obtain much of this information from your network administrator. After you have completed the worksheets, you will have all the information you need to run Fast Setup and to configure the controller successfully.

Step 2 - Set Up the Controller Connect these accessories to the Model 200 Controller: power cord, monitor, keyboard, and mouse. Use the figure below to help you locate the ports for these accessories. For help, see Chapter 2, “Setting Up the Controller,” in the Model 200 Controller User’s Manual.

Model 200 Controller Rear Panel AC out

Voltage select

COM1 COM2

110V

KEYBD

MOUSE

Fan

8

AC in

Keyboard port

Mouse port

LPT1

LPT1

VIDEO

Video port

0200-003

Page 12

Fast Setup Quick Reference Guide

Power Cord The standard power cord that comes with the controller is a 110V U.S. cord. If you need another power cord, contact your local Intermec representative. Note: Intermec recommends that you plug the power cord into a surge protector or an uninterruptable power supply. 1. Plug the power cord’s 3-pin connector into the AC in receptacle in the rear panel of the controller. 2. Plug the other end of the power cord into an AC power outlet, a surge protector, or an uninterruptable power supply. 3. Set the voltage select switch to 110V or 220V.

Monitor 1. Plug the end of the monitor cable into the video port in the rear panel of the controller. 2. Attach one end of the power cable to the monitor and the other end to an AC outlet.

Keyboard • Plug the keyboard connector into the keyboard port in the rear panel of the controller.

Mouse • Plug the mouse connector into the mouse port in the rear panel of the controller.

9

Page 13

Fast Setup Quick Reference Guide

Step 3 - Install the Controller You must physically connect the Model 200 Controller to your data collection network and to your host environment.

Connecting to Your Data Collection Network • Connect the controller to your data collection network. For help, see “Installing the Controller” in the chapter designed for your downline network in the Model 200 Controller User’s Manual.

Connecting to Your Host Environment • Connect the controller to your host environment. For help, see “Installing the Controller” in the chapter designed for your upline network in the Model 200 Controller User’s Manual. Note: If you are using 10Base2, make sure that you connect the cable to the port and connection before turning on the controller.

10

Page 14

Fast Setup Quick Reference Guide

Turning on the Controller When you turn on the controller for the first time, a dialog box appears that lists the network adapter cards, RF controller cards, and COM ports in your controller. Choose one of the following options: • If you want this dialog box to appear every time the controller boots, choose Show at Boot Time. This dialog box may be helpful when troubleshooting the controller. • If you never want this dialog box to appear, choose Hide at Boot Time. The main menu appears. Choose Fast Setup. The Fast Setup main menu appears.

11

Page 15

Fast Setup Quick Reference Guide

About the Fast Setup Main Menu This main menu appears whenever you turn on the Model 200 Controller. In the title bar, [Save] and [Activate] appear when you make changes to the configuration that you need to save and activate. The Fast Setup main menu has three parts.

Toolbar Buttons The buttons across the top of the main menu are grouped into two sections: Fast Setup and Advanced Setup. This quick reference guide (QRG) addresses how to use the first button, Fast Setup. For more information on Advanced Setup, see the Model 200 Controller User’s Manual.

Sidebar Buttons The buttons on the right side of the main menu perform system functions on the controller. This QRG explains how to use Save Configuration, Save and Activate, Start Data Collection, Stop Data Collection, Shutdown Controller, System Parameters, and some of the commands in the System Maintenance dialog box. For more information on the other buttons, see the Model 200 Controller User’s Manual.

Checklist Box The checklist box on the bottom left side of the main menu lists the three steps you complete to configure the controller in Fast Setup: 1. Local Network Adapters. This box is checked after you enter the required parameters that identify the network adapter cards in the controller to the network. 2. Downline Network. This box is checked after you configure the controller for your downline data collection network, including configuring any RF controller cards, the UDP Plus network, and any external Intermec controllers. 3. Host Connections. This box is checked after you configure the host connections for terminal emulation, peer-to-peer applications, or terminal sessions for screen mapping.

12

Page 16

Fast Setup Quick Reference Guide

Step 4 - Set the System Parameters When you set these system parameters, you are defining the operating parameters for the Model 200 Controller.

13

Page 17

Fast Setup Quick Reference Guide

Field

Description

Value

Default

Send to downline devices every...

This check box determines if the Model 200 Controller sends its time to all external Intermec controllers.

Check, Clear

Check

...minutes

This field specifies how often in minutes the controller sends the time synchronization message.

0 to 9999

60

File Transfer Time

This box specifies how long in seconds the controller waits for a response from the data collection device when it is downloading files, before it times out.

0 to 9999

180

ID delimiter

The character that the data collection devices use to separate the transaction ID from the transaction fields.

Predefined

, (comma)

Bad ID response (Optional)

The message that the controller sends to the source of the transaction if the controller does not recognize the transaction ID.

1 to 39 characters

None

Max connections (Peer-to-peer)

A tuning value that defines the maximum number of connections for each NetComm process.

1 to 256

10

Strip pad (Peer-to-peer, APPC only)

The pad character, which is used by fixed-length transactions from a host application, that you want the controller to remove before sending the transaction.

Predefined

None

Auto-start data collection when the Model 200 Controller is booted.

This check box determines if the controller starts data collection when it is booted.

Check, Clear

Clear

Terminal Emulation Setup Screens

This box allows you to customize which terminal emulation buttons appear in the main menu.

VT/ANSI, 5250, 3270

All

14

Page 18

Fast Setup Quick Reference Guide

To set the system parameters 1. From the main menu sidebar buttons, choose System Parameters. The System Parameters dialog box appears. 2. Enable or disable time synchronization. A check in the check box indicates that time synchronization is enabled. Enter how often you want the controller to send the time broadcast to all external Intermec controllers and BRUs. 3. In the File Transfer Time box, enter how long you want the controller to wait for a response from a device when it is downloading files to that device, before it times out. 4. In the ID delimiter field, click the down arrow on the right side of the field. A list of available delimiters appears. Select the delimiter that you want to use to separate the transaction ID from the rest of the transaction fields in data coming from data collection devices. 5. (Optional) In the Bad ID response field, enter the message that you want sent back to the source of the transaction if the controller does not recognize the transaction ID. 6. In the Peer-to-Peer Network Connection Parameters box, enter the maximum number of connections for each NetComm process. 7. (Peer-to-peer applications, APPC only) In the Strip pad field, click the down arrow on the right side of the field. A list of characters that a host application may use to pad fixed-length transactions appears. Select the character that the controller removes before sending on the transaction. 8. In the Auto-Start box, enable or disable the controller from automatically starting data collection when it boots. A check in the check box indicates that the controller automatically starts data collection. 9. In the Terminal Emulation Setup Screens box, choose which type of terminal emulation you want displayed in the main menu. 10. Choose OK to save your changes and return to the main menu.

15

Page 19

Fast Setup Quick Reference Guide

Step 5 - Set Up the Data Collection Environment Worksheets available • • • • •

Model 200 Controller to RF Card Worksheet Model 200 Controller to TRAKKER Antares Terminals Worksheet Model 200 Controller to 9180 and CrossBar Worksheet Model 200 Controller to 9180 Worksheet Model 200 Controller to CrossBar Worksheet

You can use Fast Setup to define the parameters for any external Intermec controllers that exist downline from the Model 200 Controller, for RF controller cards that you may have inside the controller, and for the controller to communicate with the TRAKKER® Antares™ terminals using UDP Plus. Fast Setup assumes that any downline device that you add to the network is configured with factory defaults. RF controller cards Fast Setup configures the controller to communicate with the first 9181 BRU on RF Card 1 and it enables this BRU. It also sets up this BRU to communicate with the first eight RF devices. If you have more than one RF card or more than one BRU, you will need to configure their RF parameters. For help configuring the other RF card, see Chapter 3, “Connecting to the Intermec RF Network” in the Model 200 Controller User’s Manual. For help configuring the BRU, see the 900 MHz RF Equipment User’s Manual. UDP Plus network Fast Setup configures the controller to communicate with JANUS devices and TRAKKER Antares terminals through the access points on an Ethernet or token ring network. You also need to define IP addresses for each of the terminals. Before you can verify your connection to the UDP Plus network, you must define an IP address for the Ethernet or token ring card. For help, see “Ethernet Adapter Card” and “Token Ring Adapter Card” later in this quick reference guide. External Intermec controllers Fast Setup configures a few of the parameters that let the controller communicate with the external Intermec controller. However, you may still need to configure your external controller to send and receive transactions to the devices. Refer to your controller’s user’s manual. Note: Once you define your external Intermec controllers, your RF controller cards, or UDP Plus and you choose Configure, Fast Setup does not let you edit the configuration. You need to use Advanced Setup to change any parameters.

16

Page 20

Fast Setup Quick Reference Guide

To get to the Fast Setup for Downline Network dialog box, from the main menu choose Fast Setup and then choose Downline Network.

Field

Description

Value

Default

Configured Connections

The external Intermec controllers, RF controller cards, or UDP Plus that you have already configured.

None

None

Available Connections

The UDP Plus, RF controller cards, or any external Intermec controllers that are available to be configured.

If you have an open serial port, the direct connect controllers are listed.

None

If you have an unconfigured RF card or UDP Plus, it is listed.

17