For the Intermec 0200

Page 111

Model 200 Controller User’s Manual

Contents of the Model 200 Controller Package

T

SE

RE

ER

58 99 05 /N P ntr Co 200 0 Co ntrol

M ler

B od o e vX ot l 20 D .X is 0 X k el 20 del

Mod

Mo

U Masers’ nua l ol e r

M Use an rs ua ’ l

LL RO NT 00 CO el 2 d Mo

0200-002

1-8

Page 112

Learning About the Controller

1

Description The Model 200 Controller contains several components on the front panel and on the rear panel that you should be able to identify.

Understanding the Front Panel Power switch

Power on indicator

Floppy disk access indicator

Floppy disk drive

CONTROLLER Model 200

RESET

0200-004

Reset switch

Hard disk access indicator

Component

Description

Power switch

Turns the controller on and off.

Power on indicator

Lights when the controller power is on.

Floppy disk access indicator

Lights when data is being read from or written to the floppy disk.

Floppy disk drive

This drive is a standard 3.5-inch high-density disk drive.

Reset switch

Performs a warm boot on the controller. Same as pressing Ctrl-Alt-Del on the keyboard.

Hard disk access indicator

Lights when data is being read from or written to the hard disk.

1-9

Page 113

Model 200 Controller User’s Manual

Understanding the Rear Panel AC out

Voltage select

COM1 COM2

110V

KEYBD

MOUSE

Fan

1-10

AC in

Keyboard port

Mouse port

LPT1

LPT1

VIDEO

Video port

0200-003

Component

Description

AC out

Provides AC power for accessories.

Voltage select

Sets the voltage of your controller to 110V or 220V.

COM1, COM2

Provides connections for external Intermec controllers, a modem, or other devices that require serial ports to connect to your controller.

Fan

Prevents your controller from overheating. When situating your controller, do not place it where the fan is obstructed.

AC in

Connects to one end of the AC power cord that provides power to the controller.

Keyboard port

Connects the keyboard to your controller.

Mouse port

Connects the mouse to your controller.

LPT1

Provides connection for the CD-ROM disk drive that you use to upgrade the software.

Video port

Connects the monitor to your controller.

Page 114

Learning About the Controller

1

About the Graphical User Interface When you are ready to turn on the Model 200 Controller, push the yellow power switch. When you power on the controller for the first time, a dialog box appears that lists the network adapter cards in your controller. Choose one of the following: • If you want this dialog box to appear every time the controller boots, choose Show at Boot Time. This dialog box may be helpful when troubleshooting the controller. • If you never want this dialog box to appear, choose Hide at Boot Time. The main menu appears.

1-11

Page 115

Model 200 Controller User’s Manual

The main menu has three parts: Title bar The bar at the top of the main menu contains the name and version. If you are configuring the controller, [Save] and [Activate] may appear in the title bar. These prompts remind you that you have made changes to the configuration that have not been saved or activated. When you choose Save Configuration or Save and Activate, these prompts disappear. Toolbar buttons The buttons across the top of the main menu are grouped into two sections: Fast Setup and Advanced Setup. The Fast Setup Quick Reference Guide addresses how to use the first button, Fast Setup. This user’s manual addresses how to use the next four buttons that comprise Advanced Setup. Sidebar buttons The buttons on the right side of the main menu perform system functions on the controller such as backing up the configuration files, viewing Hot Standby files, and defining system parameters.

Using Help The Model 200 Controller includes online help that provides descriptions of the controller toolbars, dialog boxes, and options. Help also provides procedural information and limited background information. To get Help • In any open dialog box, choose the Help button. The Help window opens and displays the topic for the toolbar or dialog box you were using. If you requested help from the main menu, the Getting Started topic appears. You can resize and move your Help window to see more of a topic at one time or to see more of the configuration window. Once the Help window appears, you operate the Help system by selecting topics, by choosing commands from the Help menus, or by choosing the Help control buttons at the bottom of the Help window. Topics that you can jump to are shown in colored or underlined text. To jump to another Help topic • Double-click the topic name. Or, press Tab until the topic is highlighted, and then press Enter.

1-12

Page 116

Learning About the Controller

1

To use the Help control buttons • Choose Previous. Or, press Esc. • Choose Search to search for help on a specific word or phrase. • Choose Index to look up a topic in the index. • Choose Contents to look up a topic in the contents. To learn more about using Help • From the sidebar buttons, choose Help.

Navigating Through Dialog Boxes In the Model 200 Controller, there are various ways that you can move through dialog boxes: To Do This Action

Do This Action

Move between fields in a dialog box

Use the mouse to click a field and the cursor moves there. Use Tab to move the cursor from field to field. Press Ctrl or Alt and then the letter underlined in the field or button name.

Access the buttons in a dialog box

Use the mouse to click them. Press Ctrl or Alt and the letter underlined in the button name. If any button is highlighted, choose another button by pressing the letter underlined in the button name without pressing Ctrl or Alt.

Go to the end of a file

Press Ctrl-End.

Go to the top of a file.

Press Ctrl-Home.

Access a window that shows you which applications are running.

Press Ctrl-Esc.

1-13

Page 117

Model 200 Controller User’s Manual

Understanding the Dialog Box Buttons These are the most common buttons that appear in the dialog boxes when you are configuring the Model 200 Controller. Button

Description

OK

Choose OK to save any changes you have made in the dialog box and exit from that dialog box. Your changes are saved in RAM. To save your changes to disk, from the main menu sidebar buttons choose Save Configuration.

Cancel

Choose Cancel to not save any changes you have made in the dialog box and exit from that dialog box.

Help

Choose Help in any dialog box to obtain help on the fields in that dialog box.

Close

Choose Close to exit a dialog box.

Add

Choose Add to add a new item such as a host. Choose OK to save this change. Choose Cancel to remove the item.

Edit

Select the item you want to change and choose Edit. Edit the information in the dialog box. Choose OK to save the change. Choose Cancel to restore the original values of the item.

Delete

Select the item you want to remove and choose Delete. A message box appears confirming that you want to delete the item. Choose Delete. Note: You may not be able to delete an object if it is linked to another object.

1-14

Page 118

Learning About the Controller

1

How the Controller Works The Model 200 Controller is composed of several software components working together to perform routing functions. For more information about these components, see your DCS 300 Technical Reference Manual. Graphical user interface (GUI) The GUI is the software that runs on the controller. You use it to set up your run-time configuration by defining the data collection equipment in the system, the names of the remote applications the controller communicates with, and various transactionrelated information. If you are using screen mapping, you can build script files and define terminal templates. You can also define system parameters and monitor your data collection system. Message handler The message handler performs transaction routing on transactions that are sent between data collection devices, applications, and the controller itself. The message handler routes transactions using two input Interprocess Communication (IPC) channels: • Receive channel for data input • ACK channel for transaction acknowledgment When the message handler reads a transaction from the Receive channel, it examines the transaction header to determine which application(s) should receive it. The message handler then places the application name in the transaction header and writes the transaction into the input channel belonging to that application. Upon receiving the transaction, the application must write an ACK transaction into the ACK channel. Once the message handler receives the ACK transaction, it deletes its copy of the transaction. Device communication processes (DevComms) DevComms are the interface between Intermec data collection devices and the message handler. DevComms implement all protocols that are required to communicate with the devices. The controller starts one DevComm for each communication channel that has been configured. DevComms are designed to communicate with Intermec data collection devices using the “out-of-box” or default protocol. You configure the DevComms when you configure the controller and identify the devices.

1-15

Page 119

Model 200 Controller User’s Manual

Network communication processes (NetComms) NetComms are the communication links between remote applications and the controller. TCP/IP NetComms use TCP sockets to send and receive data from the message handler. APPC NetComms use APPC sessions to send and receive data from the message handler. NetComms provide network transparency. For example, the controller writes a transaction into an input channel for an application. A local send NetComm reads the transaction from the input channel and sends it to a remote application. The remote application processes the transaction and acknowledges the receipt of the transaction from the local send NetComm. The local send NetComm then writes an ACK transaction to the ACK channel. When a remote application sends a transaction to the controller, the transaction is actually received by the receive NetComm and then forwarded to the input channel. When the controller is started, it recognizes each remote application and then it creates the NetComms. Emulator communications (EmComms) EmComms provide an interface between the controller and applications running in a VT, ANSI, 5250, or 3270 terminal emulator. EmComms allow transaction data from a data collection device to be mapped to host applications running in a terminal emulator. Note: The terminal sessions are established and run on the controller, not on the data collection devices. For example, a transaction is built by a JR2020 and then transmitted through the BRU to the controller. The controller DevComm routes the transaction to the Receive channel where the message handler receives it and passes the transaction along to the screen mapping application (EmComm) input channel. Then, the data in the transaction is routed to the screen mapping application that uses a script file to put the data into the 5250 emulator screens on the host. The screen mapping application then sends an ACK to the message handler indicating that it received the transaction data. Terminal session manager (TSM) The controller TSM establishes sessions and routes messages between a host application and the TE software running on the JANUS devices and TRAKKER Antares terminals. When the device requests a session to start, the terminal session manager verifies that sessions are available. If a session is available, the device is connected. If no session is available, the terminal session manager returns an error to the device.

1-16

Page 120

Learning About the Controller

1

About Transactions Communications from an application through the Model 200 Controller to data collection devices and other applications involve two types of transactions: data transactions and system transactions.

Data Transactions The message handler uses the transaction ID to determine the destinations for a transaction; it is the primary routing mechanism used by the controller. When a data collection device transmits a data stream, the data stream contains the transaction ID. The DevComm locate the end of the transaction ID using the system delimiter. Then, the DevComm removes the transaction ID from the data stream, and places it in the header of the transaction. If a device cannot place a transaction ID in the data stream, you can configure one for it. All transactions are date/time stamped in the transaction header. The controller also maintains a unique message number counter for each application. All data transactions are sequential; therefore, an application can use its counter to check for transaction continuity. Each transaction has a well-defined structure consisting of a transaction header and a data field. • The transaction header contains 96 bytes. • The transaction data can consist of a maximum of 1024 bytes.

System Transactions System transactions provide various system control and system operation functions. They consist of a single mnemonic string, such as Inter. To send a system transaction to the controller, the application places the system transaction mnemonic into the destination field, DestApId, of the transaction header and sets the system transaction flag to S. Applications must acknowledge all system transactions. For example, all applications must recognize the system transaction DcmSysHalt, which informs applications that the controller has shut down. For more information on system transactions, see the DCS 300 Technical Reference Manual.

1-17