For the Intermec 0200

Page 101

Model 200 Controller User’s Manual

Other Intermec Manuals You may need additional information when working with the Model 200 Controller in an Intermec data collection network. Please visit our web site at www.intermec.com to access many of our available manuals in PDF format. Your local Intermec representative or distributor can help you order printed versions of Intermec manuals. This list contains only some of the manuals for Intermec’s more recent products that can communicate through the controller.

Manual

Intermec Part No.

DCS 300 Technical Reference Manual

067717

Data Communications Reference Manual

044737

Intermec 900 MHz Products RF System/9180 Controller User’s Manual

054292

900 MHz RF Equipment User’s Manual

066163

900 MHz RF Gateway User’s Manual

066164

JANUS 2010 Hand-Held Computer User’s Manual (4MB)

065714

JANUS 2020 Hand-Held Computer User’s Manual (4MB)

065715

JANUS 2050 Vehicle Mount Computer User’s Manual (4MB)

065716

Intermec 2.4 GHz Products xxii

0110/0111/0115 Access Point User’s Manual

065053

2100 Universal Access Point User’s Manual

067150

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual

064024

TRAKKER Antares 248X Stationary Terminal User’s Manual

066960

TRAKKER Antares Terminal Emulation User’s Guide

066694

JANUS 2020 Hand-Held Computer User’s Manual (4MB)

065715

JANUS 2050 Vehicle Mount Computer User’s Manual (4MB)

065716

JANUS 2.4 GHz Installation Utility Kit for 4MB Devices

064672

Page 102

Before You Begin

Other Intermec Manuals (continued)

Manual

Intermec Part No.

Intermec CrossBar Products 9154 Multi-Drop Line Controller System Manual

048517

9160A Installation Manual

044170

9161A Operator Guide

046070

9161B Programmer/Operator Guide

049574

9161B Installation Manual

049572 xxiii

Page 103

Model 200 Controller User’s Manual xxiv

Page 104

1 Learning About the Controller

Page 105

Model 200 Controller User’s Manual

Page 106

Learning About the Controller

1

This chapter helps you learn about the features of the Model 200 Controller and how the controller works with your LAN and Intermec’s data collection network.

Chapter Checklist Done?

‰ ‰ ‰ ‰ ‰

Task

Page

Understand the features of your Model 200 Controller.

1-4

Unpack the controller.

1-7

Identify the components on the front and rear panels.

1-9

Understand the main menu, online help, how to navigate through dialog boxes, and the most common buttons in the graphical user interface (GUI).

1-11

Understand how the controller works and how transactions are routed in your data collection network.

1-15

If you already understand and have performed these tasks, proceed to Chapter 2, “Setting Up the Controller.”

1-3

Page 107

Model 200 Controller User’s Manual

Features The Model 200 Controller is a network controller that connects Intermec’s wired and wireless products either to your local area network or directly to a host. Your controller has many important features that make it easy to integrate it into your data collection system. These features include: • An easy-to-use Fast Setup program with a graphical user interface (GUI). Fast Setup uses default values to help you get the controller quickly connected to your network. • An Advanced Setup program that uses a GUI to help you customize the controller. • Network adapter cards that support connections to hosts: Ethernet, token ring, twinaxial, coaxial, and SDLC networks. • VT/ANSI terminal emulation for JANUS® devices and TRAKKER® Antares™ terminals to TCP/IP hosts. • TN5250/TN3270 for JANUS 2.4 GHz RF devices and TRAKKER Antares terminals to TCP/IP hosts that support Telnet. • 5250/3270 terminal emulation for JANUS devices and TRAKKER Antares terminals to SNA hosts. • Peer-to-peer communications for APPC/LU6.2 and TCP/IP. • Direct TCP/IP socket interface between data collection devices and hosts. • Optional Script Builder tool that allows you to create custom screens and script files so that you can run VT, ANSI, 5250, or 3270 screen mapping. • Optional RF controller cards (up to two) that support Intermec’s 900 MHz RF network. Each card supports up to four 9181 Base Radio Units (BRUs). • Migration to or support for Intermec’s 9180 Network Controller. • Support for Intermec’s CrossBar® network through existing CrossBar controllers. • Ability to store and forward data from your data collection devices to your hosts. • Local management of external Intermec controllers and other data collection devices.

1-4

Page 108

Learning About the Controller

1

• Routing of transactions to one or multiple hosts. • Localized language support for single-byte character sets in data collection devices that are running terminal emulation. • Firmware Upgrade Utility that allows you to upgrade the firmware on your TRAKKER Antares terminals.

What’s New for Release 3.1? • Dynamic Host Configuration Protocol (DHCP) client support for the Model 200 Controller. • Domain Naming Services (DNS) client support for the Model 200 Controller. • Support for international text pass-through for peer-to-peer and direct TCP/IP applications. • Support for double-byte character sets (DBCS) and data streams. • Support for remote access to the Model 200 Controller using a third party remote console package. • Ability to print to a printer attached to a terminal serial port that is within all terminal emulation clients. • New system diagnostics tools: message log formatter, SNA subsystem management, and trace utility. • New VT/ANSI screen mapping functionality to equal IBM screen mapping functionality. See the DCS 300 Technical Reference Manual. • New screen mapping functionality. See the DCS 300 Technical Reference Manual.

1-5

Page 109

Model 200 Controller User’s Manual

Connecting the Model 200 Controller to Intermec’s Data Collection Network Host

2.4 GHz T2425

JG2050 JG2020 Access Point

RS- 485 Model 200 Controller

Ethernet RS-232 CrossBar

900 MHz

9154

9181

9445

J2050 RS-232

9189 3400 JR2020

J2010

0200-024

3400

1-6

Page 110

Learning About the Controller

1

Unpacking the Controller 1. Set the controller on a clean, stable, flat surface and remove the accessories, packing material, and the Model 200 Controller from the shipping container. 2. Save the shipping container and packing material in case you need to move or ship your controller. 3. Verify the contents of the shipping container against the list below. If any parts are missing, contact your local Intermec representative. • Model 200 Controller • AC power cord • Keyboard • Mouse • 3.5-inch disk to use for backing up your system files and run-time configuration • Model 200 Controller Manual Supplement • Model 200 Controller System Manual, which includes the Fast Setup Quick Reference Guide and the Model 200 Controller User’s Manual 4. Report any damage or defects. Intermec thoroughly tested and inspected the controller before it was shipped to you. If any items are damaged, please take the following steps to correct the problem. • Take photographs, if necessary. • Contact the transport carrier. • Return the Model 200 Controller package to Intermec.

1-7