The text of a manual · part 9 of 15

Ingenico 6780 User's Guide: 6 System Parameters Menu, pages 66 to 74

Pages 66 to 74 of 119, from Ingenico 6780 User's Guide

The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Ingenico i6780

Page 66

Sys Parameters Download Method Download Port Setup Port Setup Port Port1 Port2 Port3 Port3 Interface Type Baud Rate Data Bits Stop Bits Parity DHCP Local IP Local IP Port Server IP Server IP Port IP Add Mask Gateway Primary DNS Primary DNS XXX.XXX.XXX.XXX

Tap Setup Port.

Tap Port3, Ethernet.

Tap ▼ until you reach Primary DNS, then tap Primary DNS.

Enter the address of the Primary DNS.

Updating…

6.4.19

Setting the Secondary DNS If you are using Ethernet, and DHCP is set to None, you will need to enter the secondary Domain Name Service (DNS). This is used to change Internet domain names and computer names into IP addresses and vice versa. DNS specifications require that each domain name is served by at least two DNS servers for redundancy, a primary and secondary.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

58

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Using the stylus, tap Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Chapter 6 System Parameters Menu Section 6.4 Setting Up the Port

Page 67

Supervisor Menu Change Password Application File Security Sys Parameters

Tap Sys Parameters.

Sys Parameters Download Method Download Port Setup Port

Tap Setup Port.

Setup Port Port1 Port2 Port3 Port3 Interface Type Baud Rate Data Bits Stop Bits Parity DHCP Local IP Local IP Port Server IP Server IP Port IP Add Mask Gateway Primary DNS Secondary DNS Secondary DNS XXX.XXX.XXX.XXX

Tap Port3, Ethernet.

Tap ▼ until you reach Secondary DNS, then tap Secondary DNS.

Enter the address of the secondary DNS.

Updating…

6.4.20

Setting the Domain Name If you are using Ethernet, and DHCP is set to None, you will need to set the domain name to use. Domain names are the human-readable addresses used on the Internet (e.g., www.microsoft.com). The Domain Name Service (DNS) translates these names into IP addresses which TCP/IP programs use directly.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Ingenico 6780 User’s Guide

59

Page 68

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Using the stylus, tap Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Tap Sys Parameters.

Sys Parameters Download Method Download Port Setup Port

Tap Setup Port.

Setup Port Port1 Port2 Port3 Port3 Interface Type Baud Rate Data Bits Stop Bits Parity DHCP Local IP Local IP Port Server IP Server IP Port IP Add Mask Gateway Primary DNS Secondary DNS Domain Name

60

Tap Port3, Ethernet.

Tap ▼ until you reach Domain Name, then tap Domain Name.

Chapter 6 System Parameters Menu Section 6.4 Setting Up the Port

Page 69

Domain Name

Enter the domain name. For example, to enter A, press 2 twice. To enter C, press 2 four times.

_QZ

ABC

DEF

1

2

3

GHI

JKL

MNO

4

5

6

PRS

TUV

WXY

7

8

9

CAN

CLR

*# , .

0

E N T E R

Updating…

6.4.21

Setting Up the Phone Number to Dial This option is not applicable to the Ingenico 6780, since none of the Ingenico 6780 configurations have a modem.

6.4.22

Setting Up the Modem Speed This option is not applicable to the Ingenico 6780, since none of the Ingenico 6780 configurations have a modem.

6.4.23

Changing the Position of the Host Port or Aux Port The ports are labeled Host, Aux, and E-NET, and by default, Port 1 = Host, Port 2 = Aux, Port 3 = Ethernet. However, you may configure Port 1, 2, or 3 as the Host port or Aux port through this menu option. For example, if your host uses Ethernet, you may set your host port as Port 3.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Using the stylus, tap Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Tap Sys Parameters.

Ingenico 6780 User’s Guide

61

Page 70

Sys Parameters Download Method Download Port Setup Port Setup Port Port1 Port2 Port3 Dial Host Port Aux Port Dial COM1 COM2 COM3

Tap Setup Port.

Tap Host or Aux port, and then press [Enter].

Select the port you want. By default, COM1 = Host, COM2 = Aux, COM3 = Ethernet.

Updating

Configuring the Host Port Auto Detect Feature

6.5

By default, the Host port is set to automatically detect the communications method being used on that port: RS232, RS485 IVI LAN protocol, RS485 Tailgate protocol, USB, or PoweredUSB.

Disabling or Enabling the Auto Detect Feature

6.5.1

When the auto detect feature is enabled on the host port, it will automatically detect the communications method being used on that port. By default, the Host port’s Auto Detect feature is enabled.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

62

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Using the stylus, tap Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Tap Sys Parameters.

Chapter 6 System Parameters Menu Section 6.5 Configuring the Host Port Auto Detect Feature

Page 71

Sys Parameters Download Method Download Port Setup Port Auto Detect Auto Detect AD On/Off AD Timeout AD Retry Times AD On/Off Off On

6.5.2

Tap Auto Detect.

Press [Enter] to select AD On/Off.

Select the option you want.

Setting the Auto Detect Timeout You can configure the amount of time after which the unit will cease trying to automatically detect the communications in Port 1, in units of 1/100 of a second.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Using the stylus, tap Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Tap Sys Parameters.

Sys Parameters Download Method Download Port Setup Port Auto Detect

Tap Auto Detect.

Auto Detect AD On/Off AD Timeout AD Retry Times

Ingenico 6780 User’s Guide

Tap AD Timeout.

63

Page 72

AD Timeout Old Value: XXXXXXXXX Enter New Value: _QZ

ABC

DEF

1

2

3

GHI

JKL

MNO

4

5

6

PRS

TUV

WXY

7

8

9

*# , .

0

Enter the amount of time after which the unit will cease trying to automatically detect the communications in the Port 1, in units of 1/100 of a second.

CAN

CLR

E N T E R

Setting the Auto Detect Retry Times

6.5.3

The Auto Detect Retry Times indicates how many times the terminal will attempt a communications protocol before trying the next one on the list. For example, if it is set to 3, when the terminal starts up, it will try 3 times to connect to the HOST in USB mode. If it fails, then it will try 3 times to connect to the HOST in RS485 mode. If it fails, then it will try 3 times to connect to the host in Tailgate mode. If it fails, then it will decide that COM1 is working in RS232 mode. Therefore, the less retry times, the less amount of time it will take to auto-detect the communications type.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

64

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Using the stylus, tap Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Tap Sys Parameters.

Sys Parameters Download Method Download Port Setup Port Auto Detect

Tap Auto Detect.

Chapter 6 System Parameters Menu Section 6.5 Configuring the Host Port Auto Detect Feature

Page 73

Auto Detect

Tap AD Retry Times.

AD On/Off AD Timeout AD Retry Times AD Retry Times Old Value: XXXXX Enter New Value: _QZ

ABC

DEF

1

2

3

GHI

JKL

MNO

4

5

6

PRS

TUV

WXY

7

8

9

*# , .

0

6.6

The current value displays. Enter the number of times to retry the auto-detection of the Host port, from 0 to 10.

CAN

CLR

E N T E R

Editing Parameters Although most parameters can be updated through the menu using the graphical user interface, the parameter editor allows you to edit parameters manually by entering the parameter ID number and numeric or alphanumeric value. This method is not recommended since it is easy to make a mistake. The parameter editor is typically used by developers and technicians to change settings that are not available in the menu options.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Using the stylus, tap Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Tap Sys Parameters.

Sys Parameters Download Method Download Port Setup Port Auto Detect Parameter Editor

Tap Parameter Editor.

Ingenico 6780 User’s Guide

65

Page 74

Parameter ID: _QZ

ABC

DEF

1

2

3

GHI

JKL

MNO

4

5

6

PRS

TUV

WXY

7

8

9

Enter the parameter ID (maximum three digits).

CAN

CLR

*# , .

0

E N T E R

Updating

For a listing of parameter ID numbers, descriptions, and values for the North American terminal application, ask your Ingenico representative for the latest copy of the internal document, NAR SSA Library: Security Part.

66

Chapter 6 System Parameters Menu Section 6.6 Editing Parameters