Page 75

Chapter 7

Diagnostic Menu 7.1

Overview This chapter describes the diagnostic tests that the customer can perform on the Ingenico 6780. The diagnostic tests allow you to isolate failures in field-installed Ingenico 6780 units. These tests are part of the operating system and are not changed by applications. The diagnostics are menu-driven with features that allow a logical progression through the tests. Once a test is selected, a test or a series of tests will be performed on the selected entity. The result of the test will be displayed to facilitate diagnosis of the malfunctioning parts.

7.2

Testing the Display Contrast To change the display contrast, see “Changing the Display Contrast“ on page 12. To test the display contrast, follow this procedure. This test tests all pixels to see if they are working.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad

Using the stylus, tap Diagnostic Menu.

Tap Display.

The pixels are tested to determine if any are not working, or are stuck on. The unit goes through the following sequence: All pixels on – White screen displays. Every other pixel off – Light gray screen displays. All pixels off – Dark gray screen displays. Every other pixel on – Light gray screen displays.

Ingenico 6780 User’s Guide

67

Page 76

Testing the Keypad

7.3

This allows you to test each key to ensure the proper value returns.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad Keypad 0 (0x30) To exit, press “Cancel”

Using the stylus, tap Diagnostic Menu.

Tap Keypad.

Press a key to test. (Here, we pressed 0). The key value and hexadecimal value stored in the terminal’s memory returns. When finished, press [Cancel].

Testing the Beeper

7.4

This feature tests the beeper by sounding and displaying each possible beep type.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad Beeper

68

Using the stylus, tap Diagnostic Menu.

Tap Beeper.

Chapter 7 Diagnostic Menu Section 7.3 Testing the Keypad

Page 77

Beeper Length: Click Frequency: Low

7.5

The terminal displays and sounds each possible beep type.

Testing the RS232 Connection This feature tests the RS232 connection.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad Beeper RS232 RS232 COM1 COM2 RS232 Host 19200, None, 8 Test OK

Ingenico 6780 User’s Guide

Using the stylus, tap Diagnostic Menu.

Tap RS232.

Select the communications port to test.

The results of the test display. Press [Cancel] to exit.

Cancel OK

69

Page 78

Testing the RS485 Tailgate Connection

7.6

This feature tests the RS485 Tailgate connection on the HOST port.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu

Tap Tailgate.

Tailgate IBM 46xx Test 2A23 (0x68)

The results of the test display. To exit, press [Cancel].

Display Keypad Beeper RS232 Tailgate

70

Using the stylus, tap Diagnostic Menu.

Chapter 7 Diagnostic Menu Section 7.6 Testing the RS485 Tailgate Connection

Page 79

7.7

Testing the USB Port This feature tests the USB connection.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad Beeper RS232 Tailgate USB USB Diagnostic Connect USB Port OK Start PC App then Push OK Key to send USB Diagnostic MESSAGE n Send . . .

Ingenico 6780 User’s Guide

Using the stylus, tap Diagnostic Menu.

Tap USB.

1. From the HOST, start uloop.exe. 2. From the terminal, press [Enter].

The results of the test display. To exit, press [Cancel].

71

Page 80

Testing the Magnetic Stripe Reader

7.8

This feature tests the magnetic stripe reader.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad Beeper RS232 Tailgate USB Mag Stripe Reader MSR Swipe Card Now MSR 2 tracks read!

Tap Mag Stripe Reader.

Swipe a magnetic stripe card. The terminal displays how many tracks were read.

MSR TrackNumber=2x, Status=0x Length=40x

The terminal displays the results of the test for the first track read.

MSR TrackNumber=1x, Status=4x Length=54x

The terminal displays the results of the test for the next track read.

Diagnostic Menu Display Keypad Beeper RS232 Tailgate USB Mag Stripe Reader

72

Using the stylus, tap Diagnostic Menu.

You are returned to the previous menu.

Chapter 7 Diagnostic Menu Section 7.8 Testing the Magnetic Stripe Reader

Page 81

7.9

Testing the Smart Card Reader This feature tests the smart card reader.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad Beeper RS232 Tailgate USB Mag Stripe Reader Smart Card Reader

Using the stylus, tap Diagnostic Menu.

Tap Smart Card Reader.

Smart Card Reader Insert Card Now

Insert a smart card.

Smart Card Reader SynchXXX card

The terminal displays the results of the smart card test.

Smart Card Reader Please remove the card!

Ingenico 6780 User’s Guide

Remove the card.

73

Page 82

Testing the SAMs

7.10

This feature tests communication between the SAM slots and the SAM micro-controller (SMC).

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad Beeper RS232 Tailgate USB Mag Stripe Reader Smart Card Reader SAM

Using the stylus, tap Diagnostic Menu.

Tap SAM.

SAM Found SAM Slot1. Found SAM Slot2. Found SAM Slot3. Found SAM Slot4.

74

SAM Check Slot2 ATR Read data from Slot2 (Result)

ATR means answer to reset.

SAM Power off all slots Close all smc slots

SMC stands for SAM micro-controller.

Chapter 7 Diagnostic Menu Section 7.10 Testing the SAMs

Page 83

7.11

Testing the Touch Screen This feature displays a grid. When you touch anywhere on the screen, a box on the grid is darkened.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad Beeper RS232 Tailgate USB Mag Stripe Reader Smart Card Reader SAM Touch Screen

Using the stylus, tap Diagnostic Menu.

Tap Touch Screen.

This feature displays a grid. When you tap the screen, a box on the grid is darkened to let you know where you tapped. This allows you to test a portion of the screen you suspect may be having problems. To exit, tap the X in the top left corner.

Ingenico 6780 User’s Guide

75

Page 84

Testing Signature Capture

7.12

This feature displays a signature capture screen, so you can test how a signature inks and displays on the screen.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad Beeper RS232 Tailgate USB Mag Stripe Reader Smart Card Reader SAM Touch Screen Signature Capture OK

Clear

Using the stylus, tap Diagnostic Menu.

Tap ▼ until you reach Signature Capture, then tap Signature Capture.

This feature displays a signature capture screen, so you can test how a signature inks and displays on the screen. When finished, tap OK.

Please sign with pen

76

Chapter 7 Diagnostic Menu Section 7.12 Testing Signature Capture

Page 85

7.13

Testing Pen Calibration Your terminal was calibrated by the manufacturer and you will not need to recalibrate it. This feature is for use by repair facilities. If they replace the glass on the display screen, or if they run a production test application, they need to recalibrate the terminal.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad Beeper RS232 Tailgate USB Mag Stripe Reader Smart Card Reader SAM Touch Screen Signature Capture Pen Calibration

Using the stylus, tap Diagnostic Menu.

Tap ▼ until you reach Pen Calibration, then tap Pen Calibration.

Please remove hands/objects from around the display Calibration will start in 3 seconds… Calibrate Pen Please tap box

Ingenico 6780 User’s Guide

Using the stylus, tap the four-box grid. The box moves around to the next corner; tap again. Repeat until you are notified if the test was successful.

77

Page 86

Calibrate Pen

You are notified if the calibration succeeded or failed.

Calibration Succeeded!

Testing Finger Calibration

7.14

Your terminal was calibrated by the manufacturer and you will not need to recalibrate it. This feature is for use by repair facilities. If they replace the glass on the display screen, or if they run a production test application, they need to recalibrate the terminal.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu

Using the stylus, tap Diagnostic Menu.

Diagnostic Menu Display Keypad Beeper RS232 Tailgate USB Mag Stripe Reader Smart Card Reader SAM Touch Screen Signature Capture Pen Calibration Finger Calibration

Tap ▼ until you reach Finger Calibration, then tap Finger Calibration.

Please remove hands/objects from around the display, calibration will start in 3 seconds…

78

Chapter 7 Diagnostic Menu Section 7.14 Testing Finger Calibration

Page 87

Calibrate Finger Please touch box

Using your finger, touch the four-box grid. The box moves around to the next corner; touch again. Tip: For the calibration to succeed, you need to touch the buttons from the side: Touch the left buttons with your left hand and the right buttons with your right hand. Repeat until you are notified that the test was successful.

7.15

Calibrate Finger

You are notified if the finger calibration was successful.

Calibration Succeeded!

If calibration failed, try again, making sure to follow the preceding tip.

SCV Verification (Ingenico use only) This test is used by the manufacturer, authorized repair centers, and deployment centers to verify that the correct configuration has been loaded for the customer. You can find the same information by going to the System Info menu and selecting Version Numbers (for details, see “Finding Version Numbers” on page 18).

Ingenico 6780 User’s Guide

79